Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹31.8 L+₹4.2 L (15.2%)Admitted-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L2 | Admitted-Finance | |
| 3 | L3₹32.0 L+₹4.4 L (15.8%)Admitted-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L3 | Admitted-Finance | |
| 4 | L4₹32.0 L+₹4.4 L (15.9%)Admitted-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L4 | Admitted-Finance | |
| 5 | L5₹32.3 L+₹4.7 L (16.9%)Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L4 | SRI SAI KRISHNA ENGINEERING WORKS L1 | Bhuvaneswari Electrical Works L3 | MONITOR ENGINEERING WORKS L6 | GS ENGINEERS L5 | jyothi constructions L2 | PNR CONSTRUCTIONS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipment, Machinery etc., as per site requirement. | ||||||||||
| 2.00 | M&L cable jointing kit for 11 KV, 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories including taking out existing un-serviceable joint kit complete all as specified and directed by Engineer-in-Charge.
Note:-
(i). The cost of Disconnecting and reconnecting the cable with existing HT network is deemed to be included in quoted unit rate against this item.
(ii). The cost of re-arranging the cable (if required) is deemed to be included in the quoted unit rate against this item. | 6 | Each | 4,000 ₹24,000 Lowest | 5,500 ₹33,000 | 6,000 ₹36,000 | 6,700 ₹40,200 | 7,500 ₹45,000 | 11,800 ₹70,800 | 5,000 ₹30,000 |
| 3.00 | All As per Item No 2.00 here in before but suitable for cable of size 240 to 300 Sqmm | 4 | Each | 4,500 ₹18,000 Lowest | 6,000 ₹24,000 | 6,000 ₹24,000 | 7,700 ₹30,800 | 9,500 ₹38,000 | 13,450 ₹53,800 | 6,000 ₹24,000 |
| 4.00 | All As per Item No 2.00 here in before but suitable for cable of size 120 to 185 sqmm for indoor termination. | 6 | Each | 4,000 ₹24,000 Lowest | 5,000 ₹30,000 | 5,500 ₹33,000 | 7,500 ₹45,000 | 7,500 ₹45,000 | 10,450 ₹62,700 | 5,000 ₹30,000 |
| 5.00 | All As per Item No 2.00 here in before but suitable for cable of size 240 to 300 sqmm for indoor termination. | 4 | Each | 4,500 ₹18,000 Lowest | 5,500 ₹22,000 | 5,500 ₹22,000 | 6,800 ₹27,200 | 9,500 ₹38,000 | 11,450 ₹45,800 | 6,000 ₹24,000 |
| 6.00 | M&L cable jointing kit for 11 KV, 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm for straight through, heat shrink type joint outdoor type with jointing material and accessories including taking out existing un-serviceable joint kit complete all as specified and directed by Emgineer-in-Charge.
Note:- The cost of necessary excavation & earth work is deemed to be included in quoted unit rate against this item | 5 | Each | 10,000 ₹50,000 | 9,500 ₹47,500 Lowest | 11,000 ₹55,000 | 11,000 ₹55,000 | 19,500 ₹97,500 | 13,850 ₹69,250 | 14,000 ₹70,000 |
| 7.00 | All As per Item No 6.00 here in before but for cable of size 120 to 185 Sqmm | 8 | Each | 9,000 ₹72,000 | 8,500 ₹68,000 Lowest | 11,000 ₹88,000 | 10,000 ₹80,000 | 16,500 ₹1,32,000 | 12,450 ₹99,600 | 12,000 ₹96,000 |
| 8.00 | Supply & laying HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 240 Sqmm, 3 core, laid in trenches / duct / on pole / on wall including taking out existing unserviceable cable complete all as specified and directed. | 50 | RM | 1,800 ₹90,000 | 1,800 ₹90,000 | 2,000 ₹1,00,000 | 2,500 ₹1,25,000 | 1,950 ₹97,500 | 1,875 ₹93,750 | 1,650 ₹82,500 Lowest |
| 9.00 | All as per Sl item No. 8.00 here in before but cross sectional area 185 Sqmm x 3 Core | 100 | RM | 1,600 ₹1,60,000 | 1,300 ₹1,30,000 Lowest | 1,900 ₹1,90,000 | 2,000 ₹2,00,000 | 1,650 ₹1,65,000 | 1,645 ₹1,64,500 | 1,500 ₹1,50,000 |
| 10.00 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed. | 82 | Cum | 200 ₹16,400 Lowest | 240 ₹19,680 | 220 ₹18,040 | 293 ₹24,026 | 270 ₹22,140 | 200 ₹16,400 Lowest | 250 ₹20,500 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Sept 2026, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
DAY TO DAY MAINTENANCE ATTENDING EMERGENCY BREAKDOWN AND CALL ON EMERGENCY REPAIRS FOR 24 HRS FOR HT/LT/AC PLANTS, DG SETS AT NSB, NP, CSP, SAMUDRIKA, SATAVAHANA, VIRBAHU AND ALLIED AREAS UNDER AGE E/M NO-I OF GE (U-I) VISAKHAPATNAM
2026_MES_783838_1
8892/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹90,000
Yes
30 Sept 2026
11 Aug 2026
21 Sept 2026
11 Aug 2026
18 Sept 2026
26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | M&L cable jointing kit for 11 KV, 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories including taking out existing un-serviceable joint kit complete all as specified and directed by Engineer-in-Charge.
Note:-
(i). The cost of Disconnecting and reconnecting the cable with existing HT network is deemed to be included in quoted unit rate against this item.
(ii). The cost of re-arranging the cable (if required) is deemed to be included in the quoted unit rate against this item. | 6 | Each | - | - |
| 3 | All As per Item No 2.00 here in before but suitable for cable of size 240 to 300 Sqmm | 4 | Each | - | - |
| 4 | All As per Item No 2.00 here in before but suitable for cable of size 120 to 185 sqmm for indoor termination. | 6 | Each | - | - |
| 5 | All As per Item No 2.00 here in before but suitable for cable of size 240 to 300 sqmm for indoor termination. | 4 | Each | - | - |
| 6 | M&L cable jointing kit for 11 KV, 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm for straight through, heat shrink type joint outdoor type with jointing material and accessories including taking out existing un-serviceable joint kit complete all as specified and directed by Emgineer-in-Charge.
Note:- The cost of necessary excavation & earth work is deemed to be included in quoted unit rate against this item | 5 | Each | - | - |
| 7 | All As per Item No 6.00 here in before but for cable of size 120 to 185 Sqmm | 8 | Each | - | - |
| 8 | Supply & laying HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 240 Sqmm, 3 core, laid in trenches / duct / on pole / on wall including taking out existing unserviceable cable complete all as specified and directed. | 50 | RM | - | - |
| 9 | All as per Sl item No. 8.00 here in before but cross sectional area 185 Sqmm x 3 Core | 100 | RM | - | - |
| 10 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed. | 82 | Cum | - | - |
| 11 | Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 52 | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8892Tender.pdf
Tender Documents • 0.77 MB
BOQ_878250.xls
BOQ • 0.63 MB
amdt1.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .