| 1 | L1₹5.0 LAccepted-AOC 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.9 L+₹92,101.44 (18.4%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.0 L+₹1.0 L (20.2%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹6.1 L+₹1.1 L (21.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹6.2 L+₹1.2 L (24.6%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
10 Feb 2021, 2:30 pmClosed
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali, Kolkata-700 014.
Electrical Installation work for existing academic building at Adyapeath Annada Polytechnic College..... E.I work.
2021_WBPWD_321849_1
WBPWD/EE/KNED/NIT-35 of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Adyapeath Annada Polytechnic College.
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,000
11 Feb 2022
1 Feb 2021
12 Feb 2021
4 Feb 2021
10 Feb 2021
4 Feb 2021
Amount
Cost for dismantiling theexisting wiring of electrical distribution system for existing academic building without damage other electrical accessories.
OUTGOING : - 1) S&F 415 V, 100 A TPN SFU --- 5 nos 1.1) S&F 100 A Fuse Link ----- 15nos 1.2) S&F ON Indication lamp -----5 nos 1.3) S&F Neutral Link ----- 5 nos 1.4) S&F 6A SP MCB----5 nos 2) S&F 415 V, 125A TPN SFU --- 2 nos 2.1) S&F 125 A Fuse Link ----- 6 nos 2.2) S&F On Indication lamp -----2 nos 2.3) S&F Neutral Link ----- 2 nos 2.4) S&F 6A SP MCB----2 nos 3) S&F 415 V, 63A TPN SFU --- 1 nos (For Lift) 3.1) S&F 63 A Fuse Link ----- 3 nos 3.2) S&F On Indication lamp -----1 nos 3.3) S&F Neutral Link ----- 1 nos 3.4) S&F 6A SP MCB----1 nos
BUSBAR ARRANGEMENT : - S&F 415V, 315A ,Copper busbar Chamber 40x06 (for Phase & neutral) -1no The complete arrangement must be wired by suitable size PVC insulated Cu wire with suitable sockets/lugs. with suitable earthing arrangement . Cable alley will be out side of incoming and outgoing main switch Each dimension 1500(H)x250mm(W)x400mm(D)...1nos Allocation- Under the stair of existing academic building. (Make- L&T/ Havells/ Standard/Schneider)
Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment . suitable for 160A incoming. INCOMING –Supplying and fixing 415 V, 125A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection - 1 No. OUTGOING-1) Supplying and fixing 240/415V, 63A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-2 Nos. 2)Supplying and fixing 240/415 V 40A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.- 2 Nos. (Make: ABB/L&T/Havells)
Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment . INCOMING –Supplying and fixing 415 V, 100A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection - 1 No. OUTGOING-1)Supplying and fixing 240/415 V 40A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.- 4 Nos. (Make: ABB/L&T/Havells)
Supplying and fixing 4 way 415V, 63 A double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING-Supplying and fixing four pole 415 V, 63A MCB Isolator on din rail of existing DBs and necessary connection......1 nos. OUTGOING- Supplying and fixing 240V, 6-32Amp SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection......12 nos (Make- Legrand/Havels/L&T/ABB/Schneider)
Supplying and fixing 4 way 415V, 40 A double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING-Supplying and fixing four pole 415 V, 40A MCB Isolator on din rail of existing DBs and necessary connection......1 nos. OUTGOING- Supplying and fixing 240V, 6-32Amp SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection......12 nos (Make- Legrand/Havels/L&T/ABB/Schneider)
Supply and laying of cable 4 core 50 sq mm after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. (From Panel to VTPNDB)(Make- Havells/ KEI/ Gloster)
Supply and laying of cable 4 core 35 sq mm after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. (From Panel to VTPNDB)& (From VTPNDB to HTPNDB)(Make- Havells/ KEI/ Gloster)
Supply and laying of cable 4 core 16 sq mm after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish (From VTPNDB to HTPNDB)(HTPNDB To SPNDB)(Make- Havells/ KEI/ Gloster)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
For 4 core 50 Sqmm
For 4 core 35 Sqmm
For 2 core 16 Sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
For 4 core 50 Sqmm
For 4 core 35 Sqmm
For 2 core 16 Sqmm
Electromech Engineers Co-Operative Society Ltd.
Messrs HI- Q - ENTERPRISE
MONDAL ELECTRIC CO.
ALPHA ELECTRICALS
MAA TARA ENTERPRISE
SHATABDI ENGINEERING AND CONSULTANCY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .