Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹20.7 L+₹3.2 L (18.5%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹21.4 L+₹3.8 L (22.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹21.7 L+₹4.2 L (23.8%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L4 | Rejected-Finance Other than lowest tender |
Tender Value
₹21.9 L
EMD Value
₹43,800
Closing Date
22 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
ADDN/ALTN TO JUNCTION BOXES AT CERTAIN LOCATIONS AT INS DRONACHARYA UNDER GE FORT KOCHI.
2021_MES_490601_1
8765/E8/GE Fort Kochi
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Fort Kochi
₹43,800
Yes
24 Jan 2022
26 Nov 2021
24 Dec 2021
27 Nov 2021
22 Dec 2021
10 Dec 2021
60 days
Amount
Supply ,install,testing and commissioning of CPRI approved LT panel board made out of 2mm thick CRCA indoor cubical type front and rear openable, degree of protection IP 54 floor mounting finished with polyurethene coating size of panel suitable for enclosing following items INCOMING : a) 400 Amps rated copper bus bar mounted on suitable SMC support - 04 Nos b) 400 Amps 4 pole 36 KA MCCB adjustable thermal magnetic release with front rotary handle - 01 No OUT GOING: c) 63 Amps 4 pole 25 KA MCCB adjustable thermal magnetic release with front rotary handle - 8 Nos d) 32 Amps 4 pole 10KA MCB - 02 Nos e) 32 Amps 2 pole 10 KA MCB - 02 Nos Digital voltmeter and ammeter with suitable CTS and indicators with control MCB and wiring with 1.5 Sqmm FRLSH copper wire - 01 set MAKE : MCCB and MCB:- L&T/LEGRAND/Schneider
Supply ,install,testing and commissioning of CPRI approved LT panel board made out of 3mm thick CRCA outdoor kiosk with front and rear hinged door with sloping canopy at the top pillar/ angle mounting degree of protection IP 65 finished with polyurethene coating size of panel suitable for enclosing following items INCOMING : a) 400 Amps rated copper bus bar mounted on suitable SMC support - 04 Nos b) 400 Amps 4 pole 36 KA MCCB adjustable thermal magnetic release with front rotary handle - 01 No OUT GOING: c) 200 Amps 4 pole 36 KA MCCB adjustable thermal magnetic release with front rotary handle - 01 Nos d) 100 Amps 4 pole 36 KA MCCB adjustable thermal magnetic release with front rotary handle - 01 Nos e) Digital voltmeter and ammeter with suitable CTS and indicators with control MCB and wiring with 1.5 Sqmm FRLSH copper wire - 01 set MAKE : MCCB/MCB:- L&T/LEGRAND
M&L for thermoplastic polycorbonate IP 65 distribution board made of high quality polycarbonate PC-Glass fiber reinforced shock proof rust free corrosion free acid and chemical resistant, fire retardant, self extinggishing having high impact against mechanical load made of halogen and silicon free recylable material confirm RoHs directive 2002/95/EC, UV resistant according to IEC 61439-1 having high grade internally embedded gasket made of polyurethene (PUR)made of accordance with IEC61439-2 for better safety enclosure shall with stand glow wire test at 960 C in accordance with IEC 60695-2-11 UL subject 94 should be flame redardant and self extinguishing in nature . fully wired as per latest electrical standards ready to use wall mounting type DB incl taking down old unserviceable MCB DBs any type and make complete all as specifed:- INCOMER: a) 100 Amps 4pole MCCB 25 KA -01 No OUT GOING: b) 32A SP MCB - 12 Nos
Supply ,install,testing and commissioning of CPRI approved LT panel board made out of 3mm thick CRCA outdoor kiosk with front and rear hinged door with sloping canopy at the top pillar/ angle mounting degree of protection IP 65 finished with polyurethene coating size of panel suitable for enclosing following items all as specified :- INCOMING : a) 200 Amps rated copper bus bar mounted on suitable SMC support - 04 Nos b) 125 Amps 4 pole 25 KA MCCB adjustable thermal magnetic release with front rotary handle - 01 No OUT GOING: c) 40 Amps 4 pole 16 KA MCCB - 02 Nos d) 40 Amps 4 pole MCB TPN - 02 Nos e) Digital voltmeter and ammeter with suitable CTS and indicators with control MCB and wiring with 1.5 Sqmm FRLSH copper wire - 01 set MAKE : MCCB and MCB:- L&T/LEGRAND/Schneider
Supply and fixing SMC junction box size of 300x200x105 mm fixed on pole including provision of MCB TPN 20 Amps fixed on rail inside box with proper hinges locking arrangements with provision of clamping accessories complete incl taking down old unsv item all as specified
Disconnecting LT cables form panel board and taking down from PCC mounting stand and breaking the existing PCC and provn of PCC stand with suitable height and width and painting the panel boards with two coats of oil paint including any welding work etc and remounting the panel board in same loacation incl connecting all cable and testing commissioning complete all as per direction of Engr- in -charge
Supply laying and testing cable XLPE insulated screened PVC bedded galvanised iron strip or wire armoured electric cables (heavy duty) 1100 volts grade with standards Al. conductor of size 35 Sq.mm 3.5 core incl taking down old unsv
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil all as specified and as directed.
M & L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
M&L sand cushioning in trenches using clean dry river sand for cable cushioning all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
M & L Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
Jack Electrolinks Private Limited
V V BHARATH ENTERPRISES
M/s.Rejoy Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .