| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC Reasonable bidder | |
| 2 | L2₹45.5 L+₹20,726.20 (0.46%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹46.9 L+₹1.6 L (3.60%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹47.8 L+₹2.5 L (5.52%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest |
Tender Value
₹48.4 L
EMD Value
₹96,800
Closing Date
17 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala cantt
ADDN / ALTN TO OFFICERS MESS AT AFS AMBALA UNDER GE (AF) AMBALA
2024_MES_651674_1
CWE/AF AMB/AMB-01/2024-25
Open Tender
Civil Works
Item Rate
180 days
AMBALA CANTT
For MES enlisted contractor Class D Category a(i) and for un-enlisted contractor refer NIT
8 documents required · 8 mandatory
₹500
GE (AF) AMBALA
₹96,800
Yes
30 Aug 2024
30 Apr 2024
19 Jun 2024
30 Apr 2024
17 Jun 2024
4 Jun 2024
30 Apr 2024 - 9 May 2024
Amount
Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed.
Excavation in trenches, not exceeding 1.5mtr wide and exceeding 1.5mtr but not exceeding 3.00 mtr in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & exceeding 1.5mtr but not exceeding 3.00 mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick each in soft/loose type of soil complete all as specified & directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
M&L for earth filling under floor, spreading & levelling in layers not exceeding 25cm thick each and well watering, ramming as required including bringing approved earth at site on contractor's own arrangement from any source outside defence land complete all as specified & directed. Note: The outside earth shall be approved by Engineer-in-charge before bringing at site.
Spreading and levelling of soil as in under floor, in layers not exceeding 25cm thick each and well ramming including watering & finishing to required shape complete all as specified & directed.
M&L laying and compaction of 300mm thick soling (or sub base) in two layers, each layer 150mm thick, with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified & directed. Note: Payment per unit shall be made for top finished surface area of 300mm thick(150mm +150mm) compacted thickness of Soling.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides of pillars, posts, struts, piers, columns & stanchions; square, circular rectangular on plan or polygonal in shape for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified & directed.
M&L brick work with flyash burnt bricks (IS-13757), old size, Designation 75, straight or curved on plan exceeding 6mtr mean radius, built in cement mortar 1:6, below/above plinth beam as per requirementcomplete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr span complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L mild steel TMT bars 10mm dia and over, Fe500/Fe500D grade confirming to IS-1786, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L mild steel TMT bars 8mm dia and over upto & inculding 10mm dia, Fe500/Fe500D grade confirming to IS-1786, cut to length cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacer & binders complete all as specified & directed.
M&L plain cement concrete(PCC) 1:4:8, type D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
M&L 100mm thick plain cement concrete(PCC) 1:4:8, type D-2 using 40mm graded mechanically crushed stone aggregate as in sub base of floor complete all as specified & directed.
M&L rendering 15mm thick in cement mortar 1:4 on stone masonry or surface other than fair face of brick masonry of wall, finished even & fair complete all as specified & directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & fair complete all as specified & directed.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling/soffits, finishing the surface even & fair complete all as specified & directed
M&L machine cut kota stone slab flooring, slab size 580mm x 580mm, 18mm to 20mm thick as in flooring, laid over & including 20 mm thick screed bed in cement mortar 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L machine cut kota stone slab flooring, 18mm to 20mm thick as in skirting/ dado/pillar, laid over & including 10 mm thick rendering/backing coat in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper of approved tint over & including one coat of alkali resistant primer and one coat minimum 1mm thick wall care putty complete all as specified & directed.
M&L preparation of newly plastered surfaces of ceiling / soffits and applying three coats of white lime wash complete all as specified & directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance , dirt resisitance exterior paint of approved shade/tint(Company depot tinted), with silicon additives @1.43 Litre/10 Sqm over & including one coat of compatible exterior primer @ 09.0 litre per 10 sqm complete all as specified & directed.
M&L water proofing treatment to roof slab complete all as specified here-in-below & as directed by Engineer-in-charge:- (i) Cleaning of dust, removal of all loose existing bituminious material manually and with heat torch gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repairing all joints and cracks with Highly elastic Bituminous cold applied putty having penetration after setting upto 8mm. (ii) Levelling of surface to give proper slope will be done as per site requirements with Bituminous Mortar & Cold Emulsion cum waterproofing Liquid of water based bituminous emulsion. (iii) Creating SSD condition on surface with water. Prime the surface with acrylic modified bitumen with potable water in the ratio of 1:1 and apply @400gm per Sqm (As per Surface Conditions). (iv) Apply first coat of acrylic modified bitumen having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm. (v) Laying Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm. Allow the first coat to dry for 10 hrs to 12 hrs. (vi) Apply second coat on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller. Allow it to dry for 10-12 hrs. (vii) Apply third coat with consumption @ 700gm per Sqm. Ensure final curing time of 36 hrs before allowing/ carrying out any further work. (viii) Conduct ponding test for minimum 7 day after applying two coats of single component , UV Resistant Elastomeric Exterior Acrylic Weather resistant water proof coating having elongation of 300% after curing of 14 days confirming to ASTM D- 6083-for UV Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membrane to give long life and prevent its deterioration from sunlight. Notes:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators only duly approved by GE in writing. (ii) For guarantee & security deposit refer Particular specifications.
S&F 12mm thick toughened glass as in doors (frameless), size 1.8 mtr x 2.4 mtr, floor mounted, stainless steel handle 300mm long-02 Nos. on each leaf, locking arrangement, including all fittings and hardwares and similar work including cutting to shape drilling holes as required complete all as specified & directed. Note: The toughned glass door shall be provided in two leafs.
S&F powder coated (minimum thickness of powder coating 50 micron) anodized aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified & directed. Note: The rates include for provision of PVC protected sheeting and its removal after fixing the frame work.
S&F anodized aluminium window and ventilator shutters side hung type without sash bars, aluminium section weighing not less than 0.55 kg/m with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber packing,anodized aluminum snap beading screws anodized aluminium fittings such as peg stays 150mm long (01 No.) hinges type B-21 100mm long (02 Nos.) suitable handle (01 No.) complete all as specified & directed. Note: Glazing shall be measured & paid separately.
M&L 8mm thick toughened glass as in window including jointing cleats, glazing clips, rubber beading, anodised aluminium snap beading etc. complete all as specified & directed.
M&L 3mm thick sheet glass ordinary quality as in ventilator and glazing with oil putty in squares not exceeding 0.5 sqm each pane complete all as specified & directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or stainless steel wire staple complete all as specified & directed.
S&F 25mm dia stainless steel curtain rods with wall thickness 1mm including stainless bracket, holding and funnel on ends complete all as specified & directed. Note: Minimum two No. bracket & two No. funnel at the end shall be provided in one opening of door/window. The Nos. may increase as per situation of door/window and as per direction of Engineer-in-charge.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 20mm dia medium grade, with fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc as in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 1.5 sqmm connected to common earth and earth dolly for one light / fan point controlled by one way switch 5/6 amp complete all as specified & directed.
Description all as per BOQ item No. 38.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the independent board.
Description all as per BOQ item No. 38.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the same board.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 25mm dia medium grade, with fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc as in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 2.5 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one way switch on the independent board complete all as specified & directed.
S&F modular switch, 5 Amp, one way, 1 module complete all as specified & directed.
S&F modular switch, 15 Amp, one way, 1 module complete all as specified & directed.
S&F modular socket outlet, 5 Amp, 2/3 pin combined, 2 module, complete all as specified & directed.
S&F modular socket outlet, 15 Amp, 5/6 pin combined, 2 module, complete all as specified & directed.
S&F ceiling rose 65mm x 50mm three terminals 230 volts complete all as specified & directed
S&F modular white cover plate with frame, 1 module complete all as specified & directed.
S&F modular white cover plate with frame, 3 module complete all as specified & directed.
S&F modular white cover plate with frame, 8 module complete all as specified & directed.
S&F modular Metal flush box 1/2 module complete all as specified & directed.
S&F modular Metal flush box 3 module complete all as specified & directed.
S&F modular Metal flush box 8 module complete all as specified & directed.
S&F recess/surface mounting LED backlit panel 2'x2' having white CRCA body with high efficient LED & glare free full window high quality PMMA diffuser of 36 watt, 5700K CCT including connecting with twin core twisted flexible copper conductor cable with suitable size rod complete with all accessories complete all as specified & directed.
S&F ceiling fans complete with blades, down rods, including modular socket type fan regulator and accessories, 230 volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) without remote, complete all as specified & directed. Note: Cost of writing MES No./SM No. on fan is included in quoted rates.
S&F exhaust fans AC single phase 230/240 volt of size 250mm sweep made of sturdy engineering plastic with louver, shutter complete including making hole /niches of suitable size along with all fixing accessories complete all as specified & diirected
S&F metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB 20 Amp concealed in wall complete all as specified & diirected
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 4 sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc. complete all as specified & directed.
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 6 sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc. complete all as specified & directed. Note for BOQ Item No. 57.00 & 58.00 :- Three runs copper cable alongwith conduit shall be measured as one unit.
S&F factory made sheet metal enclosure distribution board, 230 volt, single pole and neutral, IP 43 protection, with 200 Amps rated copper busbar and neutral link, 8 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified & directed.
S&F factory made sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings, vertical TPN load line distribution board with provision of mounting MCCB, double door IP 56 protection as per IS 8623-III, 160 Amp rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified & directed. Note: MCCB shall be measured & paid separately.
S&F MCB 40 Amp, SPN, C curve 240 volts, 10 kA finger proof terminal, bi-connect terminatin, label holder, 35 sqmm terminal capacity, insulated sliding shutter , large two position dolly to be fixed on DB complete all as specified & directed.
S&F MCB 5 to 32 Amp, SP, C curve 240 volts, 10 kA finger proof terminal, bi-connect terminatin, label holder, 35 sqmm terminal capacity, insulated sliding shutter , large two position dolly to be fixed on DB etc complete all as specified & directed.
S&F MCCB 4 pole, 100 amp current rating, thermal setting adjustable 70% - 100%, breaking capacity 16 kA at 415 volt, 50Hz complete all as specified & directed.
M&L earthing complete with galvanized steel earth plate electrode 600mm X 600mm, 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire 4.0mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe 1.5 mtr long medium grade GI 20 mm bore including protection pipe upto 7.5 mtr long GI light grade 15mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 50mm thick Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with XPM weighing not less than 4Kg/sqm including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes :- On testing if the earth resistance is not obtained, earthing will be generated at no extra cost ,till the desired earth resistance is obtained.
M&L sand cushioning to cable with a layer of fine sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed.
Supply & laying old size, common burnt clay, sub class 'B' bricks, designation 75, laid flat & dry for protection of electric cable in trenches, adjacent to each other, perpendicular to central axis of electric cable complete all as specified & directed.
Supply, laying, jointing, testing & commissioning of LT electric cable, 1100 Volts grade, heavy duty, XLPE insulated, armoured electric power cable with aluminium conductor of cross sectional area 50 sqmm, 3.5 core conforming to IS- 7098 (Part I) 1988 laid as in trenches or fixed along the wall/pole or passing through pipes/ducts etc, complete all as specified & directed.
M&L making bore below the road for crossing the GI pipe light grade 50mm bore for cable protection and fill the putty on both sides of the GI pipe after crossing the electric cable to avoid the water inside complete all as specified & directed.
M&L galvanized steel tubing 50mm light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings wherever required complete all as specified & directed.
KULWANT SINGH
S M BUILDERS
M/s B.S.Jain
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .