| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹17.2 L+₹23,313 (1.37%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹18.5 L+₹1.5 L (8.89%)Rejected-Finance | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹18.7 L+₹1.7 L (10.3%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹18.8 L+₹1.8 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
21 Oct 2019, 6:00 pmClosed
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
PROVN OF LOW SECURITY WALL ALONGWITH GATE AT CP NO VI AND PROVN OF SECURITY FENCE FOR 680 I TK TPTR PL ASC AND PROVN OF COVERED HARDSTANDING AS SITTING FACILITY FOR DRIVERS AT WARCEN UNDER AOR OF AGE BR II OF GE A CENTRAL JODHPUR (8908/E8)
2019_MES_284573_1
GE/J/A- of 2019-2020 (8908/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
1.Scanned copy of Application and DD Banker Cheque as cost of tender and copy of EMD for unenlisted contractor 2.Copy of GST Registration Number 3.Copy of enlistment letter 4. For unenlisted contractor details of documents meeting enlistment criteria
5 documents required · 5 mandatory
₹500
GE (A) Central Jodhpur
₹44,000
Yes
21 Feb 2020
23 Sept 2019
23 Oct 2019
23 Sept 2019
21 Oct 2019
5 Oct 2019
Amount
Excavation in trenches nexc 1.5 m wide & 1.5 m in depth & getting out in any type of soil , complete all as specified and as directed.
Returning filling in incl spreading well ramming & watering and well ramming in layers not exc. 25 cm , complete all as specified and as directed.
Removal of surplus excavated soil upto a distance nexc 50 m & depositing where directed at a level nexc 1.50 m above the starting point , complete all as specified and as directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregates as in foundation & mass filling, complete all as specified and as directed.
M&L for PCC 1:2:4 type B2 using 40 mm graded stone aggregates as in foundation & mass fillings , complete all as specified and as directed.
M&L for stone masonry squared ruble Jodhpur type masonry brought upto courses built in CM 1:6 , complete all as specified and as directed.
Extra over squared ruble brought upto courses Jodhpur type masonry with max depression from a st edge held against the dressed surface nexc 20 mm ., complete all as specified and as directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in footing of columns , complete all as specified and as directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in columns ( Hexagonal / Octagonal shape ) , complete all as specified and as directed.
M&L for formwork to sides of footings with rough finished surfaces , complete all as specified and as directed.
M&L for formwork to sides of columns (hexahonal/octagonal in shape) with rough finished surfaces , complete all as specified and as directed.
M&L for 10 mm dia & over TMT reinf steel bars cut to length bent to shape required incl binding with MS binding wire annealed ( not less than 0.90mm dia) , complete all as specified and as directed.
Do but 5 mm dia & over but in stirrups/rings & binders , complete all as specified and as directed.
M&L for face work masonry with 100-125 m thick white / chitter sand stone having rock face bushings not less than 15-20 mm incl chisel drafted margin 20-25 mm wide all as per local Jodhpur Pattern (KADAOU) regular coursed well bonded bedded & solidly hearted built in CM 1:4 complete all as specified . Height of Kadaou stone course shall not be less than 200mm all as directed at site.
M&L for keyed pointing to kadaou facework of Jodhpur sandstone in CM 1:3 using white cement & pigment to match the shade of the stone, complete all as specified and as directed.
Surface excavation nexc 30 cm deep & averaging 10 cm deep & getting out in soft loose soil , complete all as specified and as directed.
M&L for sand filling under floors etc complete incl watering & well ramming , complete all as specified and as directed.
S&F machine made precast cement concrete blocks (interlocking paves) Rubberised finish coloured of 60mm thick with 6mm top layers of anti abrasive material all as as per sample kept in GE Office.
M&L for framed work using MS angle iron , rectangular hollow sections. Solid Sq Bars , Flat iron ,MS Channel sections , or hollow structural tubes etc incl necessary cutting & bending to shape & welding together complete as in gates , cattle traps , overhead trusses , railings etc complete all as per the design & patterns complete all as directed at site.
M&L for welding Cast iron designer pieces like spikes , spiral patterns & moulding pieces etc with intricate designs to the steel gate frame work complete all as specified & directed .
M&L prep of new steel surfaces & applying 02 coats of syn enamel paint over a coat of red oxide primer, complete all as specified and as directed.
M&L for fixing letters fabricated from 2 mm thick stainless steel sheet with mirror optic finish complete of size 60-75 height in English/Hindi fonts complete with nuts & bolts , complete all as specified and as directed.
M&L for sand stone moulded weathered , complete all as specified and as directed.complete.
Demolition of stone masonry built in cement mortar, complete all as specified and as directed.
M&L for fixing in position of Sand Stone Chattri Jodhpur pattern octagonal shape each side of length 65 to 75 cm & height not less than1.20m ( excluding dome) incl 8 nos sand stone columns, sand stone arches , brackets & sand stone dome slab of minimum 75 cm height of approved shape & carvings incl 1 no Brass finials of ht 0.30 m complete all as per trade pattern of interlocking & fixing of parts with suitable solvent cement adhesive all as directed & as per sketch attached .
M&L for 15 mm thick cement rendering in CM 1:6 over stone masonry surfaces & finishing the surface even & smooth w/o using extra cement .
M&L for prep of new plastered surfaces & applying two coat of cement base paint all as directed .
M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregates) as in coping., complete all as specified and as directed.
M&L for keyed pointing in CM 1:3 to Squared rubble regular coursed Jodhpur type masonry , complete all as specified and as directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Excavation in post holes(or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in any type of soil, complete all as specified and as directed.
M&L, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed. .
S & F Rolled Mild Steel sections confirming to Fe 410 - S as in fencing pole or other similar work including MS flat all as directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size andy type of standards, rails, straining bolts etc. complete including provision of binding wire , complete all as specified and as directed.
Supply only chain link MS Galvanized fencing any size or type , complete all as specified and as directed.
S&F MS round bars 10mm dia & above cut to length bent to shape required including cranking bending spirally for hopping for column hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to IS.
S&F mild steel screw bolts (machine made) with hexagonal or square head and one end screwed or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut, not exc. 5 cm long of 12mm dia of shank.
M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer , complete all as specified and as directed.
M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of black bituminious paint all as specified.
M&L for PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregates as in coping and plinth protection etc, complete all as specified and as directed.
M&L, 10 mm thick rendering concrete surface in CM (1:3), complete all as specified and as directed.
100 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregates as in sub base of floor ,path , etc complete all as specified
M&L for Cement concrete 1:2;4 type B2 using 40 mm graded stone agg as in foundations, filling and mass concrete
M&L for 75 mm thick sub base in PCC 1:4:8 type D2 using 40 mm graded stone agg..
M&L for mild steel frame work in trusses purlins, posts etc complete using MS angle iron, MS Hollow Square or rectangular sections,flat irons etc complete incl necessary welding cutting to shape & hoisted & fixed in position complete all as directed & specified .
M&L for pre painted galvalume aluminium zinc GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with J or L hooks complete all as directed.
S&F of 0.50 mm thick end piece of pre painted galvalume aluminium zinc GI based sheet of any colour fixed to steel truss etc all as per sample, complete all as specified and as directed.
S&F machine made precast cement concrete curb stone blocks using Cement concrete 1:3:6 type C2 (20mm stone agg) , complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry 1:3:6 type C1 with solid blocks, exc. 10 cm in width and setting in mortar, complete built in CM 1:6 , complete all as specified and as directed.
M&L for 10 mm thick Rendering in CM 1:6 on fair faces of brick wk or concrete surfaces & finishing the surfaces even & smooth w/o using extra cement
M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregates) as in copings, kneelers, apex stones, bed plates, kerbs lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, not provided including weathering, slightly rounded or chamfered angles and throating,
M&L for machine cut Sand Stone slab 75-80 mm thick dressed true and square, in one length not less than n. exc150cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced, complete all as specified and as directed.
Supply,laying and fixing only along the poles or passing through walls etc jointing and testing LT Cross Linked Polythene Insulated galvanised steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC of cross sectional area 16 sqmm x 4 core all as directed by Engg-in-charge.
All as per Item No. 59 above but 6 sq mm 2 core all as directed by Engineer In Charge
Supply and fixing for LED Post top lanten 1x45 Watt with all required acessories and connections Make ;CG/Philips/Havells
Supply and fixing for pressure die cast housing with IP 65 protection LED Area lighting fitting 1x 90 Watt with all requid acessories and connection including necessary PCC Work requird for fixing etc complete. Make ; CG/PHILIPS/Havells
Supply install testing and commissioning of factory made LT Panel board (LT Kiosk))out door type pedestal mounting totally enclosed dust and vermin proof, double shutter front opening including PCC (1:3:6) Type C1 for padestal of suitable size made out of 2.0mm thick MS Sheet and suitable size of angle iron frame ,dust proof busbar chamber of Copper busbar cap 150 Amps 4 pole ,and suitable size of angle iron frame powder coated finish including making connection for incoming and out going cable with suitable size of cable lugs and cable glands inclusing consisting of following :- (a) MCCB 63 Amps 4 Pole 16 KA -01 Nos (As incomer) (b) )MCB SPN 20 Amps SPN 10 KA -06 Nos (For out going ) ( c ) Indicating lamps RYB Led Type - 01 Set (d) Amps meter and Volts meter Digital type with inbuilt salector switch -01 Set. (e ) Internal wiring complete with copper conductor cable not less than 4 sq mm FR .
M/L in repairs sub main wiring with 4 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable, passing through in and including PVC conduit ( MMS), ISI marked and making good the distrurbed surface of wall incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire, complete all as specified and as directed.
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for laying of cables etc. n.exc 10sq m on plan and n exc 1.5m in depth and getting out in any type of soil, complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50 metre and deposRing where directed at a level not exceeding 1.5 metre above the starting point.
Returning, filling in trenches with excavated soil, including, spreading, levelling, watering and well rammin in la ers not exceeding 25 cm thick complete.
S & L Jodhpur stone quarry faced stone slab cover 40 to 50mm thick, 25cm to 30cm wide, 60cm long, laid dry and abutting each other with gap cetween adjacent slab not exceeding 10mm over under ground cables for protection.
Sand cushioning to under ground cable using river sand and gently punning for cushioning to cable, complete all as specified and as directed.
M & L for earthling complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L pipe galvanized iron light grade complete with all fittings laid in road crossing, and on pole, buildings complete all as specified and directed ISI marked. of 40mm bore, complete all as specified and as directed.
Harsh Enterprises
Nikhat nirman
Hariom Construction Company
D DEV COMPANY
BEYLIM INFRA
ABHOG INFRASTRUCTURE PRIVATE LIMITED
Jai Doulat Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .