Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 CrAccepted-AOC | ₹20.6 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹21.3 CrRejected-Finance | ₹21.3 Cr | L2 | Rejected-Finance L1 is Heather |
| 3 | L3₹21.3 CrRejected-Finance KANNUR | KERALA | 670001 | ₹21.3 Cr | L3 | Rejected-Finance l1 is Heather |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
₹19.4 Cr
EMD Value
₹5 L
Closing Date
30 Nov 2022, 3:00 pmClosed
The Regional Manager,WAPCOS Limited
WAPCOS LIMITED 1st Floor, JP Krishna Building, Pallimukku, Pettah Trivandrum - 695024
Development of Taluk Hospital Balusseri in Kozhikkode District
2022_WAPCO_524868_1
WAP/INFRA/KERALA/22/THB/387-2
Open Tender
Civil Works - Buildings
390 days
Balusseri Kozhikkode District
As per Tender Documents
19 documents required · 19 mandatory
₹16,800
₹5 L
WAPCOS Limited,Trivandrum
1 Jun 2023
4 Nov 2022
1 Dec 2022
4 Nov 2022
30 Nov 2022
16 Nov 2022
15 Nov 2022
Amount
EARTH WORK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
od297921/2021_2022 : Extra for every additional lead up to 1 km beyond initial lead of 50 m of the excavated/ stacked material. All kind of soil
SUB STRUCTURE
od81823/2021_2022 : "Boring, providing and installation bored cast-in-situ reinforced cement concrete<br>piles<br>of garde M-30 ofspecified diameter and length below pile cap, to carry a safe working load not less<br>than<br>specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite<br>solution<br>andtemporary casing of appropriate length for setting out and removal of same and the length<br>of the pile<br>tobe embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig<br>all<br>complete,including removal of excavated earth with all its lifts and leads (length of pile for payment<br>shall<br>bemeasured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tube well boring machine<br>shall not<br>be used. Minimum cement content of 350 kg/cum 500MM<br>"
od81824/2021_2022 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of<br>specified diameter and length below pile cap including additives and admixtures, to carry a safe working load not less than specified,<br>excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and<br>temporary casing of appropriate length for setting out and removal of same and the length of the pile to<br>be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,<br>including removal of excavated earth with all its lifts and leads (length of pile for payment shall be<br>measured up to bottom of pile cap).<br>Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>600 mm dia piles
od81825/2021_2022 : Boring, providing and installation bored cast-in-situ reinforced cement concrete<br>pilesof garde M-30 ofspecified diameter and length below pile cap, to carry a safe working load not less thanspecified,excluding the cost of steel reinforcement but including the cost of boring with bentonite<br>solutionandtemporary casing of appropriate length for setting out and removal of same and the length of the<br>piletobe embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig<br>allcomplete,including removal of excavated earth with all its lifts and leads (length of pile for payment<br>shallbemeasured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tube well boring machine shall<br>notbe used. Minimum cement content of 350kg/cum -700mm
od81829/2021_2022 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>1000 mm dia piles
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.34.3 : Extra for providing richer mixes at all floor levels. Providing M-40 grade concrete instead of M-25 grade BMC/RMC.(Note : Cement content considered in M-40 is @ 360 kg/cum).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od283099/2021_2022 : Carrying out initial vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.600mm dia piles ( 2.5 times the theoretical design vertical load capacity of 97 tonne .)
od283100/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.1000mm dia piles ( 1.5 times the theoretical design vertical load capacity of 270 tonne .)
od288457/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.500mm dia piles ( 1.5 times the theoretical design vertical load capacity of 69.5tonne .)
od288580/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.600mm dia piles ( 1.5 times the theoretical design vertical load capacity of 97tonne .)
od288661/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.700mm dia piles ( 1.5 times the theoretical design vertical load capacity of 127.5 tonne .)
od288665/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.800mm dia piles ( 1.5 times the theoretical design vertical load capacity of 173 tonne .)
od288671/2021_2022 : Carrying out Routine vertical load tests as per relevant IS code including all arrangements for measuring deflections and submitting report as per specification including making pile head for testing at the required level, supporting / reaction arrangement ( including reaction piles/ soil/ rock anchors if any) for the kentledge load.900mm dia piles ( 1.5 times the theoretical design vertical load capacity of 219 tonne .)
MASONRY WORK
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
REINFORCED CEMENT CONCRETE
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:-.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.34.3 : Extra for providing richer mixes at all floor levels. Note:- .Providing M-40 grade concrete instead of M-25 grade BMC/RMC.(Note : Cement content considered in M-40 is @ 360 kg/cum).
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
FINISHING
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
od298393/2021_2022 : Providing and laying Ceramic Anti Skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
11.47.2 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
od146225/2021_2022 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.<br>Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
od146294/2021_2022 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
od81831/2021_2022 : Providing fundermax or equivalent sheets, 6mm thick with 0.25mm thick aluminium foils divided into rectangles of the maximum area of 4'x5', panel form, fixing to 50x25x1.8mm thick MS sections and 40x25x2mm MS angles, sealing the joints with 789 Dow corning sealant and finishing the sealant with approved shade and any other hardware required in position, so as to ensure a smooth seamless water proof and level surface without any bends, undulation and deformities etc. complete to specification.<br>
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
5.25 : Providing and fixing in position copper plate as per design for expansion joints.
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
9.147D.1 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
9.147D.4 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
9.118.3 : Providing and fixing to existing door frames25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with and average wall thickness of 1 mm ( ± 0.3 mm). PVC foam end cap of size 23x10 mm area provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end -cap of the size 25 mm x 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer,s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
21.2.1 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
od81837/2021_2022 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:<br>150x10 mm
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
22.14.1 : Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7 : Providing and fixing ball bearing for rolling shutters.
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).
50.12.2.2 : Providing & fixing Poly carbonate multi wall plain sheet 4 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal / vertical / curved surfaces, but excluding the cost of purlins, rafters, trusses and including cutting to size and shapes where ever required.
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand)
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
16.78.2 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
CANOPY
od81822/2021_2022 : Providing MS fabricated canopy 7.6m long & 5m wide using 150mmx75mmx1.4mm section of approximate 120x90cm grids, providing 11.52mm thick toughened and laminated glass( 5mm clear toughened glass +1.52 PVB +5mm clear tougneded glass) fixed VHB on both sides, tapes, silicon etc. including two priming coat of metal primer, insulation at site including welding joints, providing 4 nos steel rod with tensioner, supports from column, beam at 45 degrees with minimum slope for water drainage , ensure proper fixing to beam/column etc. complete as per specification.
Structural Steel Roof
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
12.4.1 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
EXTERNAL STAIRCASE
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Landscape works
od277259/2021_2022 : Taking pit of size 0.75M x0.75 M x0.75 M , fill it with earth and organic manure mixture and supply and planting trees DELONIX REGIA
CIVIL WORK FOR SUMP
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:-.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
od146324/2021_2022 : Providing circular concrete rings of 4 ft internal diameter
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
STEEL REINFORCEMENT
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
FINISHING WORKS
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
od146321/2021_2022 : Providing fillings in Soak pit
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
PLANT ROOM
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level
od146325/2021_2022 : Solid block masonry using pre cast Fly ash solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
10.10.1 : Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od146326/2021_2022 : "Supplying and fixing C.I cover with frame for manholes:<br>600 x 600 mm C.I cover ( light duty ) the weight of the cover to be no less than 23 kg"<br>
od146327/2021_2022 : Supplying and fixing C.I cover with frame for manholes: 500mm dia C.I cover (medium duty ) the weight of the cover to be no less than 58 kg
Vertical Expansion
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. .All work above plinth level upto floor V level
5.34.1 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Civil Finishing Work
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
od297801/2021_2022 : Providing and laying Ceramic Anti Skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
od146243/2021_2022 : Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge.<br>8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
od146273/2021_2022 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
od79356/2021_2022 : Providing and fixing Aluminium composite panel 4mm thick for aluminium doors with necessary screws, beedings etc complete<br>
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
9.118.3 : Providing and fixing to existing door frames25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with and average wall thickness of 1 mm ( ± 0.3 mm). PVC foam end cap of size 23x10 mm area provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end -cap of the size 25 mm x 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer,s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where everrequired) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape &size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br>Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
9.147A.5 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.74.3 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm
21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
Structural Steel Roof Work
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
WIRING
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required.
1.39 : Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor / wall, or side of the table / door etc. as required.
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
od249658/2021_2022 : Supplying and fixing extra conduit down rod of 20 em length G.l. pipe 15 mm dia,<br>heavy gauge including painting etc. as required. (Note : More than 5 em length shall<br>be rounded to the nearest 10 em and 5 em or less shall be ignored)
od249659/2021_2022 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on<br>surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular<br>socket outlet and 15/16 A modular switch, connection etc. as required.
MCB Switch Gears &amp;amp; DB's
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
od96710/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) -6 way (4 + 12), Double door
od96713/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) -8 way (4 + 12), Double door
od96730/2021_2022 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-8 way (4 + 24), Double door<br>
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
EARTHING
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
LT CABLE LAYING
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
HT CABLE LAYING
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
MV &amp; HT CABLE JOINTING &amp; END TERMINATION
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
ELECTRICAL MISC
15.2 : Supplying, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection .) having high preformance, regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
11.6.2 : Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.40 mm dia
MISC CIVIL
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
10.18 : Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.38 : Filling with available fly ash and earth ( excluding rock) in trenches or embankment in layers ( each layer should not exceed 15 cm), with intermediate layer of compacted earth ( Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer - in- charge, including compacting each layer by rolling / ramming and watering, all complete as per drawing and direction of Engineer - in-charge
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
16.71 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer - in- Charge.
16.74.2 : 75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with:Stone aggregate 20 mm nominal size
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
HT PART
od96668/2021_2022 : 400kVA TRANSFORMER<br>Supply, installation ,testing & commissioning of 400kVA 11kV/433V indoor cast resin dry type USS transformer (copper wound) having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with off-circuit tapping +5% to -5% in steps of 2.5% by tap links, include separate winding temperature indicator for each phase and core in the Transformer, emergency off switch housed seperately outside. Transformer should have cable end box on HV side suitable for 3Cx300 sq.mm XLPE 11kV cable and suitable end box on LV side for connecting XLPE insulated PVC cables with all accessories, complete as required as per State electricity board, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/1985 with latest amendment etc complete with HT HRC fuses and output connected to 11KV seal off bushings to the transformer. Losses shall confirm to latest IS tolerances and as per GRIHA standards.<br>Supply, Installation, testing and commissioning of Unitised substation with load break switch as primary protection, dry cast resin power transformer, cable end termination facility etc. as follows. HT load break switch fuse unit 630A -1 No. 26.3kA , 630A Aluminium busbar with heat shrinkable insulation and support insulator (SMC / DMC ) - 1set, Earthing switch interlocked with the main switch - 1 No, Mechanical and electrical on / off indictaion etc<br>The LBSP should have necessary provision to add HT TOD Bidirectional meter as check meter without sealing provision, including class 1 HT CT and PT as per requirements.<br>Supply, Installation, testing and commissioning<br>
od96684/2021_2022 : Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. <br>3cx300sq.mm XLPE Cable<br>
od96685/2021_2022 : Laying of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in separate existing cable tray/ on surface using factory made clamps and the spacing between clamps will not exceed 60cm.<br>Above 120 sq. mm and upto 400 sq. mm
od96708/2021_2022 : Supply, erection, testing and commisioning of dust and vermin proof, floor mounted free standing cubicle type 11kV outdoor metering panel box IP67, fully compartmentalised complete with hinged and earthed front doors interlocked with earth switch with provision for TOD metering. Unit shall comprise of 3 nos. CT's 15A/5A of 10VA burden, and class Cl:0.2S and including fixed type PT of ratio 11kV/110V, 25VA, Cl:0.2S (1 No.) and seal off bushings, space heater with thermostat including 400A Aluminium busbars with support insulators and all other accesories as required for complete installation as required and instructed by engineer in charge/consultant. Viewing glass for HT meter shall be provided with sealing provision for KSEBL.<br>
od96714/2021_2022 : Supply, installation, testing and commissioning of State Electricity board incoming 2 pole structure which consists of required length HT Pre-stressed Concrete Poles (PSC), HT stay set complete, 11kV pin type insulator, channel cross arm, 11kV disc insulator with tension set, earth pipe with clamp ,GI :4mm dia wire, 9kV / 5kA Lighting Arrestor set, 400A Air Break switch with operating handle and locking mechanism, DO fuse set, supports, jumpers, interconnecting conductors and all required accessories complete as per State Electricity board requirements. The cost of the civil foundation not to be considered and shall be measured along with the civil items. <br>
od96724/2021_2022 : BIDIRECTIONAL HT TOD NET METER<br>Supply, Installation, testing & commissioning of 3 phase 4 wire according to IS14697-1999, CBIP-325, IS 159595A, class: 0.2S, TOD meter with RS485 port, LCD with backlit display of Electricity board approved make, in existing enclosures of outdoor metering cubicle/LBSM panel including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. (Make - L&T ER300P or equivalent)<br>Supply,Installation, testing and commisioning
DIESEL GENERATOR SUPPLY &amp;amp; INSTALLATION
od96683/2021_2022 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works for support and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>150mm dia
od96693/2021_2022 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works for support and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>200mm dia <br>
od96707/2021_2022 : Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.<br>
od96715/2021_2022 : DG set commisioning including Trial run of DG set for 6 hrs. on no-load and variable load condition and to record the parameters as per prescribed format as per manufacturer standards. Cost of consumable ( fuel oil, lube oil, etc.) to be borne by Contractor.<br>
od249664/2021_2022 : Supply & providing thermal insulation for silencer with inner glass wool and providing aluminium cladding for 400 kVA DG set exhaust pipe length as per standards.
LT PANELS
od96690/2021_2022 : LIFT PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>"Incomer - 40A FP Isolator - 1 no.<br><br><br>"<br>40A, 433V,best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>32A FP 100mA FP RCBO - 1 no<br>25A DP 30mA RCBO - 1 no.<br>25A, 433V, Al SPN bus bar <br>6A SP MCB - 4 nos<br>Supply, Installation, erection, testing and commissioning
od96702/2021_2022 : PLUMBING PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>"Incomer - 63A FP Isolator - 1 no.<br><br><br>"<br>63A, 433V,best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>32A TP MCB - 4 nos<br>25A TP MCB - 2 nos<br>Supply, Installation, erection, testing and commissioning
od96716/2021_2022 : 1F Ward Block Panel<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec including necessary HRC fuse for protection of same. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Incomer -<br>250A, 36kA FP Thermal magnetic based MCCB - 1 no<br>250A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B & Class C/ Type 1 & Class 2 and fuse for protection of the same - 1 set<br>Outgoings<br>160A 25kA TP Thermal magnetic based MCCB - 1 no<br>32A 25kA TP Thermal magnetic based MCCB - 2 no<br>63A 25kA TP Thermal magnetic based MCCB - 4 no<br>Supply, Installation, erection, testing and commissioning
od96756/2021_2022 : FIRE PANEL<br>Fabrication, supply, erection, testing and commissioning of motor control panel of cubicle type, dust and vermin proof, floor/wall mounted, front operated power control make MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Panel shall be fabricated with necessary provision for Class B + Class C/ Class 1 + Class 2 Surge arrestor device.Including providing surge arrestor and necessary MCCB switch for its protection and Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with potential free contact, provision for inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec <br>Incomer:200A TPN Isolator - 1Nos. <br>200A 415V, 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement <br>OUTGOING <br>160A, TP Isolator for 50HP pump along with starter as per NBC norms w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms -1 Nos <br>40A, TP Isolator for 7.5HP pump along with starter as per NBC norms w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms -1 Nos
od96765/2021_2022 : HVAC PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec including necessary HRC fuse for protection of same. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Incomer -<br>250A 25kA FP Thermal Magnetic Based MCCB - 1 no<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>250A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Outgoings<br>32A 16kA TP Thermal Magnetic Based MCCB - 4 nos<br>63A 16kA TP Thermal Magnetic Based MCCB - 5 nos<br>80A 16kA TP Thermal Magnetic Based MCCB - 1 nos<br><br>Supply, Installation, erection, testing and commissioning <br>
od96779/2021_2022 : COMMON SERVICE PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec including necessary HRC fuse for protection of same. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Incomer 1 -<br>125A FP Isolator - 1 no.<br>Incomer 2 -<br>100A FP Isolator - 1 no.<br>RYB phase indicating LED lamps with control fuses and switches - 2 set<br>125A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Outgoings<br>63A 25kA TP Thermal Magnetic Based MCCB - 2 nos<br>40A 25kA TP Thermal Magnetic Based MCCB - 4 nos<br><br>Supply, Installation, erection, testing and commissioning <br>
od249668/2021_2022 : MAIN PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec including necessary HRC fuse for protection of same. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary potential free contacts shall be provided from the panel for intergrating with IBMS as per IO summary<br>Incomer -<br>EB Incomer - 630A, 50kA FP EDO Microprocessor based MCCB having isolation duty with 3 O/C and 1 E/F release and standby low set EF relay using CT at neutral earthing conductor.- 1 no<br>DG Incomer 1 - 630A 50 kA FP EDO Microprocessor based MCCB having isolation duty set and standby low set EF relay using CT at neutral earthing conductor.- 1 no<br>630A, ATS with AMF(ASCO) - 1 no.<br>630A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Surge Protection Device Class B & Class C/ Type 1 & Class 2 and fuse for protection of the same - 1 set<br>Reverse power relay for DG switch - 1 no<br>Outgoings<br>320A 36kA TP Thermal Magnetic Based MCCB - 1 nos<br>250A 36kA TP Thermal Magnetic Based MCCB - 2 no<br>200A 36kA TP Thermal Magnetic Based MCCB - 2 nos<br>160A 36kA TP Thermal Magnetic Based MCCB - 3 nos<br>160A 36kA FP Thermal Magnetic Based MCCB - 1 nos<br>160A FP Contactor - 1 no<br>125A 36kA TP Thermal Magnetic Based MCCB - 1 no<br>200A FP Isolator - 1 no<br>Supply, Installation, erection, testing and commissioning
CABLES &amp;amp; END TERMINATION
od96671/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx400sq.mm Al Cable
od96682/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx300sq.mm Al Cable<br>
od96686/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx240sq.mm Al Cable<br>
od96704/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx150sq.mm Al Cable<br>
od96717/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx50sq.mm Al Cable<br>
od96723/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx70sq.mm Al Cable<br>
od96736/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4x25sq.mm Al Cable<br>
od96742/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4x16sq.mm Al Cable<br>
od96746/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4x10sq.mm Al Cable<br>
od96751/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4x6sq.mm Al Cable<br>
od96757/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>12CX2.5 sqmm Cu cable<br><br>
od96767/2021_2022 : Supply and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1Cx35sq.mm Copper Flexible Cable<br>
od96772/2021_2022 : Supply and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.<br>1Cx50sq.mm Copper Flexible Cable<br>
od249809/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx2.5sq.mm Cu Control Cable
od249810/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3x10sq.mm Al Cable
od249811/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx35sq.mm Al Cable
od249812/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx185sq.mm Al Cable
END TERMINATION
od96673/2021_2022 : Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>4Cx6sq.mm Al Cable<br>
od96681/2021_2022 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>35 sq.mm<br>
od96694/2021_2022 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.<br>50 sq.mm<br>
od96718/2021_2022 : Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>2Cx2.5 sq.mm Cu Control Cable<br><br>
od96729/2021_2022 : Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured.<br>12Cx2.5 sq.mm Cu Control Cable<br>
LIGHT &amp;amp; FAN FIXTURES
od96674/2021_2022 : Supply of Recess mounted LED Downlight of wattage 12W with die cast aluminum housing and high transmitivity diffuser. CRI>80, LED Efficacy>150lm/W, Color Temperature-5700K, IP 40 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, Power factor>0.90, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with system Efficacy ≥ 100lm/W including all accesories as required for complete installation (Wipro LD06-151-XXX-57-XX or equivalent)<br>
od96680/2021_2022 : Supply of Recess mounted LED Downlight of wattage 15W with die cast aluminum housing and high transmitivity diffuser. CRI>80, LED Efficacy>150lm/W, Color Temperature-5700K, IP 40 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, Power factor>0.90, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with system efficacy ≥ 100lm/W including all accesories as required for complete installation (Wipro LD06-171-XXX-57-XX or equivalent)<br>
od96689/2021_2022 : Supply of Surface mounted LED Downlight of wattage 15W with die cast aluminum housing and high transmitivity diffuser. CRI>80, LED Efficacy>150lm/W, Color Temperature-5700K, IP 40 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, Power factor>0.90, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with system efficacy ≥ 100lm/W including all accesories as required for complete installation (Wipro LD99-211-XXX-57SMWH or equivalent)<br>
od96719/2021_2022 : Supply of eight feet linear suspended luminaire of wattage 30W. Luminaire is made up of CRCA white powder coated housing , better aesthetic finish and Highly efficient PMMA diffusers for better light transmission and pure effect. CRI>80, Efficacy>150lm/W, color temperature-5700K, IP20 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>88%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with System Efficacy ≥ 100lm/W including all accesories as required for complete installation (Wipro LM31-401-XXX-57WG1+WVX861 or equivalent)<br>
od96734/2021_2022 : Supply of Recess mounted 2x2 LED Luminaire of wattage 36W. LED with housing made of White powder coated, higher efficacy, full diffuser providing uniform light. CRI>80, LED Efficacy>120lm/W, color temperature-5700K, IP20 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with System Efficacy ≥ 100lm/W. including all accesories as required for complete installation (Wipro CRCO10R038HP57GL1 or equivalent)<br>
od96737/2021_2022 : Supply of 25W LED streetlight with housing made of die-cast aluminium with polycarbonate lens for uniform light distribution. IP66 rated complete with all accessories required for installation including 0.5m length arm for mounting the of light fixture.<br>
od96741/2021_2022 : Supply of surface/wall mounted 10W LED Bulkhead. Die cast Aluminium housing with complete assembly and PC opal diffuser for uniform illumination. IP65. including all accessories as required for complete installation (Wipro Bulkhead LW07 or equivalent)<br>
od96747/2021_2022 : Supply ,installation, testing and commissioning of LED Post Top with a system lumen output of ≥ 2300 lumens .The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI > 70. The luminaire shall meet IP65 with THD < 20% and PF > 0.9. The luminaire shall have closed diffused optics with polycarbonate diffuser board. The total power consumption should not exceed 27W (including driver). The luminaire shall be made up of aluminium die cast housing with polycarboate cover. Luminaire should be with minimum system efficacy of ≥ 85Lumen/Watt. Luminaire should withstand THD less than 10% and should have power factor > 0.90. Driver efficiency should be 85% . Luminaire should comply with all the required IEC standards and should operate in a voltage range of 220-240 volts AC. The luminaire shall be dark grey in color. The LEDs used shall be of high power LEDs. The driver shall be potted type. The luminaire shall be BIS tested and approved / registered mentioning 'R' number and test certificates of LM79 and LM80 reports shall be submitted, including all accesories as required for complete installation. (Make : Philips BGP161 LED23WW PSU or equivalent)<br>Post top<br>
od96753/2021_2022 : Supply of exhaust fan of 250mm sweep in the existing opening, as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, Ventil Air DX White or equivalent)<br>
od96758/2021_2022 : Supply of heavy duty exhaust fan of 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, TurboForce SP or equivalent)<br>
od96761/2021_2022 : FAN FIXTURES<br>Supplying 5 star rated , BEE certified 26W, ceiling fan with BLDC motor, with super enamelled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length downrod all accesories required for complete installation (Havells Efficienca Neo or equivalent)<br>
od249829/2021_2022 : Supply of Recess mounted Cleanroom LED Luminaire of wattage 42W with housing made of CRCA powder coated. Excellent heat dissipation through special design of high thermal conductivity Metal Clad PCB. CRI>80, LED Efficacy>150lm/W, color temperature-5700K, IP54 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with System Efficacy ≥ 98lm/W including all accesories as required for complete installation (Wipro LC20-551-XXX-57-XX or equivalent)
od249830/2021_2022 : Supply of surface mounted LED Batten of wattage 40W. High efficiency aluminium profile linear batten with polycarbonate diffuser for enhanced productivity. CRI>80 LED Efficacy>150lm/W, color temperature-5700K, IP20 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>88%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with System Efficacy ≥ 100lm/W. including all accesories as required for complete installation. (Wipro LL24-541-XXX-57-XX or equivalent)
od249831/2021_2022 : Supply of surface mounted LED Batten of wattage 20W High efficiency aluminium profile linear batten with polycarbonate diffuser for enhanced productivity. CRI>80, LED Efficacy>150lm/W, color temperature-5700K, IP40 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>88%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard with system efficacy ≥ 100lm/W. including all accesories as required for complete installation (Wipro LL24-251-XXX-57-XX or equivalent)
MISCELLANEOUS
od96665/2021_2022 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>20mm dia <br>
od96679/2021_2022 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>25mm dia <br>
od96692/2021_2022 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>32A 30mA FP RCBO
od96699/2021_2022 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>32A 100mA FP RCBO
od96703/2021_2022 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>40A 100mA FP RCBO<br>
od96720/2021_2022 : Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant..<br>63A 100mA FP RCBO<br>
od96725/2021_2022 : Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)<br>One light point controlled by one way switch <br>
od96733/2021_2022 : Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)<br>Loop wiring for Light point<br>
od96738/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>100A FP Isolator with enclosure<br>
od96743/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>40A FP Isolator with enclosure<br>
od96749/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>80A FP Isolator with enclosure<br>
od96755/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A DP Isolator with enclosure<br>
od96760/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A FP Isolator with enclosure
od96762/2021_2022 : Supply and fixing of FP CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP isolators confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>25A FP Isolator with enclosure<br>
od96769/2021_2022 : Supply and fixing of module CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP RCBO confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A 300mA FP RCBO<br>
od96773/2021_2022 : Supply and fixing of module CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP RCBO confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>63A 300mA FP RCBO<br>
od96774/2021_2022 : Supply and fixing of module CRCA sheet steel powder coated enclosure on surface/recess along with following Amps, 415V, FP RCBO confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>80A 300mA FP RCBO<br>
od96777/2021_2022 : Supply, Fixing, testing and commisisoning of 4 module Matt black finish pop up box with slim design for perfect integration into furniture equipped with one number 6A socket and one number CAT 6 data socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required.<br>Pop up box - 4 module<br>
od96778/2021_2022 : Supply, Fixing, testing and commisisoning of 8(2x4) module Matt black finish pop up box with slim design for perfect integration into furniture equipped with 2 number 6A socket and 1 number CAT 6 data socket & provision for fixing and including one number AV/HDMI socket supplied alongwith installation kits for table tops and all accessories as required for complete installation including making good any damages made, as instructed by engineer in charge, providing connections etc as required. <br>Pop up box - 8 module<br>
od96780/2021_2022 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 67) with DIN rail for providing RCBO protection of suitable rating , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation.. <br>20A 2P+E<br>
od96781/2021_2022 : Supply, installation, testing and commisioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation.<br>32A, 433V, FP COS<br><br>
od96782/2021_2022 : Supply and fixing of modular 25A power socket placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation.<br>25A Power Socket<br>
od96783/2021_2022 : Supply and fixing of modular 25A power switch with indication placed in and including suitable size modular base and coverplate, mounted on suitable size modular GI/open PVC box, reccessed in the case of GI, fixing providing connections, testing and commisisoning and making good any damages made during installation as instructed by engineer in charge, including all accesories, connections and interconnections as required for complete installation.<br>25A Power Switch<br>
od96784/2021_2022 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>1/2 Module<br>
od96785/2021_2022 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>3 Module<br>
od96786/2021_2022 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>4 Module<br>
od96787/2021_2022 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>6 Module<br>
od96788/2021_2022 : Supply and fixing of following modules metal mounting boxes in surface/ recess including making good the damages made during installation and all accessories required for complete installation as instructed by engineer in charge/consultant.(for bed panels)<br>8 Module<br>
od96789/2021_2022 : TPN HORIZONTAL DB<br>Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) <br>12 way DB
od96790/2021_2022 : Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. <br>32 x 12.5mm CMS <br>
od96791/2021_2022 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.<br>120 mm dia (OD-120 mm & ID-103 mm nominal)
od96792/2021_2022 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.<br>63 mm dia (OD-63 mm & ID-51 mm nominal)
od96793/2021_2022 : 75 mm thick back filling for pitching including supplying of required<br>materials and consolidation etc. complete with :<br>Stone aggregate 20 mm nominal size
od96667/2021_2022 : 60 kVA THREE PHASE TO THREE PHASE UPS<br>Supply installation, testing and commissioning of following three phase to three phase UPS indoor (IP20) in stand alone configuration,true online double conversion DSP based UPS system in stand alone configuration with inbuilt parallel kit capable of connecting UPS in parallel mode when required without additional cost, with 15 min backup battery ( battery of reputed make) with, input pf>.9, less input current consumption, with necessary battery circuit breaker., with input 415V, 50Hz three phase, output 415V, IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 94% and output power factor > 0.9 and including all accessories etc as required. The UPS system shall be with automatic & manual maintenance bypass switch facility.UPS shall have seperate battery bank, and batteries shall be connected in single string.The system shall comply to IEC /EN 62040-1 and relevant IS standard.The acoustic noise of the system should be less than 58dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. The UPS shall be with BMS card/module for integrating with IBMS using Modbus/BackNet protocol <br>60kVA UPS - 1No <br>Battery Circuit Breaker-1No <br>Battery - Required nos. of SMF batteries for providing 15 Minutes Back UP and Battery Accessories like battery rack, interconnecting cables etc.
od96678/2021_2022 : 80 kVA THREE PHASE TO THREE PHASE UPS<br>Supply installation, testing and commissioning of following three phase to three phase UPS indoor (IP20) in stand alone configuration,true online double conversion DSP based UPS system in stand alone configuration with inbuilt parallel kit capable of connecting UPS in parallel mode when required without additional cost, with 15 min backup battery ( battery of reputed make) with, input pf>.9, less input current consumption, with necessary battery circuit breaker., with input 415V, 50Hz three phase, output 415V, IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 94% and output power factor > 0.9 and including all accessories etc as required. The UPS system shall be with automatic & manual maintenance bypass switch facility.UPS shall have seperate battery bank, and batteries shall be connected in single string.The system shall comply to IEC /EN 62040-1 and relevant IS standard.The acoustic noise of the system should be less than 58dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. The UPS shall be with BMS card/module for integrating with IBMS using Modbus/BackNet protocol <br>80kVA UPS - 1No <br>Battery Circuit Breaker-1No <br>Battery - Required nos.of SMF for providing 15 Minutes Back UP and Battery Accessories like battery rack, interconnecting cables etc.
LIGHTNING &amp;amp; EARTHING PROTECTION
od96666/2021_2022 : Supply, installation and testing of 2 meter air terminal with accessories: Providing and fixing Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod 2 meter rod: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 2000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. including all accesories as required for complete installation and as instructed by engineer in charge.<br>
od96677/2021_2022 : "Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accesories as required for complete installation as instructed by engineer in charge.Price shall be inclusive of conductor holders."<br>Vertical run- Down conductor<br>
od96691/2021_2022 : "Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accesories as required for complete installation as instructed by engineer in charge.Price shall be inclusive of conductor holders."<br>Horizontal run-Parapet application<br>
od96701/2021_2022 : Supply and fixing of cross connector/T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts and all accesories as required for complete installation<br>
od96705/2021_2022 : Supply and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) and all accesories as required for complete installation<br>
od96721/2021_2022 : Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications(Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotetial bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carring lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accesories as required for complete installation as instructed by engineer in charge.<br>
od96727/2021_2022 : "Supply and laying hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including cross connectors and all accesories as required for complete installation as instructed by engineer in charge.<br><br>"<br>
od96731/2021_2022 : Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.<br>
od96739/2021_2022 : Supply and fixing of PVC trapezoidal 2.5m long ducts including the fastening clamps and all accessories as required.<br>
od96744/2021_2022 : Supply, installation and testing of maintenance free Earthing system as per IS 2309 ,IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 & UL 96 standards. Earthing System comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling bore and peg arrangement (without the need for external coupler) with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. For obtaining desired length, the number of rods shall be increased and is provided with Universal Clamp (2730 20 VA) made of SS 304 for clamping the cable/flat conductor to the rod. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS PB 12.5) is used for improving the soil conductivity. Earth enhancing mineral compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be mineral inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The material should have a resistivity less than 0.2 Ohm meter. It should be free from hazardous substances The mineral compound is required to have minimum 12.5 Kg of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 5KN, including all accesories as required for complete installation as instructed by engineer in charge. (Minimum 2 earth pits shall be provided. No of earth pits shall be increased till overall earth resistance of the system is less than 10ohms as per site conditions and soil resistivity)<br>
od96748/2021_2022 : Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 450mm x 450mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )<br>
od96750/2021_2022 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>32x3mm Cu strips tinned at the point of contact<br>
od96754/2021_2022 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>25x3mm Cu strips tinned at the point of contact<br>
od96759/2021_2022 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>32x3mm Cu strips tinned at the point of contact<br>
od96764/2021_2022 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>25x3mm Cu strips tinned at the point of contact<br>
od96768/2021_2022 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.10 SWG <br>
od96770/2021_2022 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.8 SWG <br>
od97694/2021_2022 : Supply, installation and testing of 4 meter air terminal with accessories:Providing and fixing Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod 4 meter rod: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305)<br>101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability.<br>Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked.<br> including all accesories as required for complete installation and as instructed by engineer in charge.
SAFETY EQUIPMENTS
od96672/2021_2022 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.<br>
od96676/2021_2022 : Supply & fixing of Class A Electrical rubber mat, used for up to 3.3 kV, Dielectric Strength of 33 kV , 2 Mtr x 1 Mtr size 2 mm thick, as per IS. 15652 - 2006 in front of various type MV panels. as per IS:15652 - 2006 with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required <br>
od96688/2021_2022 : Supply and providing First Aid Box.<br>
od96697/2021_2022 : Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.<br>
od96711/2021_2022 : Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.<br>
od96722/2021_2022 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc.<br>
od96726/2021_2022 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer.<br>
od96735/2021_2022 : Supply of 1 pair 11 KV rubber hand gloves of approved make.<br>
od96740/2021_2022 : Supply & fixing of Class A Electrical rubber mat, used for high voltage 11kV , 2 Mtr x 1 Mtr size 3 mm thick, as per IS. 15652 - 2006. with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required <br>
Hot DipGalvanized Iron Cable Tray
od96669/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>450 mm width X 62.5 mm depth X 2.0 mm thickness
od96675/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. <br>600 mm width X 62.5 mm depth X 2.0 mm thickness
od96687/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. <br>300 mm width X 62.5 mm depth X 1.6 mm thickness
od96698/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. <br>200 mm width X 50 mm depth X 1.6 mm thickness
od96706/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. <br>150 mm width X 50 mm depth X 1.6 mm thickness
od96712/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. <br>100 mm width X 50 mm depth X 1.6 mm thickness
ENERGY MANAGEMENT AND ALLIED WORKS
od249836/2021_2022 : Providing termination for RS485 cable<br>
od249837/2021_2022 : RS485 CABLE<br>Supply, laying, tieying/clamping, testing and commisioning of Shielded data cable, copper with low impedance, 0.5mm capable to transmit the data of energy meter's serial port RS485 including all accessories as required<br>
od249839/2021_2022 : Supply installation, testing and commisioning of Ethernet Switch 5 way-Gigabit Switch including all assecories as required<br>
od249840/2021_2022 : Supply installation, testing and commisioning of 1 /port RS485 Serial to Modbus TCP/IP Communication Gateway including all assecories as required<br>
od249841/2021_2022 : Supply instllation, testing and commisioning of PC server system with following minimum specification, the processor shall be minimum Intel i5, 8 core CPU (3 GHz or better), 64 bit, 8 GB RAM, DVD ROM, 1TB HDD ( Approx. 2 year data saving), USB PORT (2 Nos.), NIC (2 Nos. – 4 ports), 2GB graphics card, 24” inch full LED monitor, USB Keyboard, USB Mouse three button & scrolling and all other accesories required which is required for the proper functioning of the system alongwith workstation furniture for installing the sytem complete as required. The software installed in the system shall be as below but not limited to the same - MS Office 2010, Windows 10, 64 bit, best class Anti-Virus software with 2 year liscence, Printer system alongwith its software and all accessories also to be considered. Adobe Reader and all other basic softwares as required for proper functioning of the system and all other accesories as required for PC server system.<br>
od249842/2021_2022 : Installation charges for EMS installations, integration charges and all charges for complete installation of componets, installation of switches, controllers, software etc, calibration, installation, integration and commisioning as per satisfaction of client and integrating with IBMS & GRIHA Platform as required<br>
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
od249855/2021_2022 : SOLAR METER<br>Supply, Installation, Testing and Commissioning of 3 phase Bidirectional meter of accuracy class 1 with necessary CT and accessories including making all connections as required. The meter and CT and all accessories to be provided in enclosure as per requirement to be provided in electrical room<br>
od249858/2021_2022 : SINGLE PHASE DIRECT METER<br>Supply, installation, testing and commisioning of Modular Single-Phase Meter DIN Rail Mounted, Direct Input up to 40A, Cl 1.0 Accuracy, with Electro Mechanical 7 Digit Display able to measure Active Energy up to 999999.9 kWh and with Pulse Output for integrating with Energy Management System including all accesories as required to be installed in DBs as required..The meter shall be with RS485 port for communication with EMS sooftware<br>
SANITARY FIXTURES AND CP FITTINGS
od149022/2021_2022 : Providing & Fixing of colour vitreous china counter top wash basin- installed on granite/ marble with CI / MS brackets, 32mm dia CP waste coupling with plug and chain, PVC / CPcold watersupply connecting pipe, one nos of 15mm dia CP angle stop cock for cold watersupply liness with wall flange etc as per IS specification make and approved by the consultant. The works shall include cutting in walls and making good the walls & floors.
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
17.7.11 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI - 304 (18/8) Wash basin 530 x 345 mm with single 15mm C.P. brass pillar tap
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm
17.69.1 : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.
od149036/2021_2022 : Providing & fixing, testing and commissioning of approved make & coloured urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications.
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
od149045/2021_2022 : Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet, Plastic Cistern , Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge.<br>
18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.
17.73.1 : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
od149052/2021_2022 : Fixing of superior quality Rob hook with brackets and flange with concealed brass screws etc as per IS specification make and approved by the client / consultant, including cutting & making good the walls.
od149056/2021_2022 : Providing and fixing of automatic sensing high jet speed hand dryer both hot and hot air of approved quality conforming to IS standards.
od247950/2021_2022 : Supply, instalation,testing and commissioning of approved make of vertical / horizontal type Electric water heater suitable for pressure rating up to 4 Kg / Sqcm with heating element with thermostat, pressure relief valve, non - return valve with CP copper connecting pipes with wall flanges etc., complete with all inlets, outlets, valves and all other accessories etc., complete.
WATER SUPPLY (INTERNAL AND EXTERNAL ):CPVC PIPES AND FITTNGS
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
18.9.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore
od149046/2021_2022 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 40 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>65mm dia <br>
od149048/2021_2022 : Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump.<br>25 mm dia <br>
od149050/2021_2022 : Supply,Installation, testing and commission, of wall mounted/ table top 10 litre water purifier with grade ABS water tank having input water source filtering capabilty of TDS upto 2000ppm.The unit includes RO membarne,filters etc. <br>
od242312/2021_2022 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc.including MS hooks for fixing pipes and making good the walls and floors.<br>40 mm nominal outer dia pipes-40mm dia pipe sch 40
od242313/2021_2022 : Providing and fixing UPVC pipes SCH 40 water supply pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge .Exposed on wall-32mm dia pipe sch 40
od242314/2021_2022 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, MS hooks/clamping acessories for fixing pipes and making good the walls and floors. External work 25 mm nominal outer dia pipes
od242315/2021_2022 : <br>Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes with threading machine, jointing using holdtile and cotton thread or shallock and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors.<br> 20 mm nominal outer dia pipes
od149053/2021_2022 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc., including making bores in walls, foundations and RCC slabs, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, MS hooks/clamping acessories for fixing pipes and making good the walls and floors.<br>50 mm dia sch 40<br>
od149054/2021_2022 : Supply and fixing of UPVC pipes and fittings / specials like tees, elbows, bends, unions, offsets, Hex nipples collars, cutting, threading the pipes and pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. including MS hooks/clambing accessories for fixing pipes and making good the walls and floors.65 mm dia sch 40(sewage pumping line)
od247939/2021_2022 : Supply,Installation, testing and commissioning of smart water meter confirming RS 485/RS232 port with publicity/industrial standards to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required. 40mm dia size
od247940/2021_2022 : Supply,Installation, testing and commissioning of data concentrator panel for water meter reading.RS 485/RS232 port with publicity/industrial standards which has to be compactible with BMS integration. The rate shall include software integrating with BMS system with specific communication protocol.
od247941/2021_2022 : Supply,Installation, testing and commissioning of smart water meter having an RS 485/RS232 port with publicity/industrial standards confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with necessary fittings such as threaded pieces, unions, check nuts complete as required with all fittings and accessories which is compactible with BMS system -50mm dia size
PVC SOIL,WASTE,VENT PIPES AND FITTINGS ( INTERNAL &amp;amp; EXTERNAL)
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.8.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
18.58.2.1 : Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating
19.4.1.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.30.2.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
19.30.3.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
od149040/2021_2022 : "Providing and fixing soil, waste and vent pipes: 110 mm dia, cowel<br>"<br>
od149043/2021_2022 : "Providing and fixing soil, waste and vent pipes: 75 mm dia, cowel<br>"<br>
od149044/2021_2022 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>110 mm dia <br>
od149047/2021_2022 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>75 mm dia <br>
PVC RAIN WATER PIPES AND FITTINGS
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
PUMPS
od149020/2021_2022 : Providing & fixing, testing and commissioning of SS centrifugal Waste water Transfer Pump(grinder pump), for pumping waste water/ Kitchen waste/ sewage waste from collection pit to Sewage treatment plant, with including solenoid valves, level switches, control wires,startor switch etc. (1Working pump+standby) with suitable HP Capacity:200lpm@25mtr head<br>
od149032/2021_2022 : Providing of 4 pair 1.5 sq mm cable as control cable of liquid water level controller through a ISI Heavy duty 20mm conduit<br>
Electrical Works for Plumbing
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
ELECTRICAL DRIVEN MAIN PUMP
od149060/2021_2022 : "Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads<br>Flow - 2280 @ 60 m<br>Pump Casing : C.I, Impeller- Bronze<br>Motor – Suitable HP/ 1500 RPM/ 3 Ph <br> b) Common bed plate for mounting Pump and Motor fabricated of Motor fabricated of suitable M.S.Channel as per manufacturer*s recommendations.
od149068/2021_2022 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.<br>M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads. a) Electrical Driven Jockey Pump :<br>Flow - 180 lpm @ 65 m<br>Motor – Suitable HP/2900 RPM/ 3 Ph
od149070/2021_2022 : Supplying, installation, testing and commissioning of diesel engine driven main fire pumpsuitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)2280 lpm at 60 m Head<br>Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads
od149081/2021_2022 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 70 sq mm on wall, floor <br>
od149086/2021_2022 : Supply of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3Cx 10 sq mm on wall, floor<br>
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
9.1.12 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
od149124/2021_2022 : Providing and fixing CI `Y' strainer suitable for operating pressure of 16 Kg / sqcm with SS 304 perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.150 mm dia<br>
od149125/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required-150mm dia
od149128/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required-100mm dia
od149130/2021_2022 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required-80mm dia
od149132/2021_2022 : Supplying, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia
od149133/2021_2022 : Supplying, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.100 mm dia<br>
od149134/2021_2022 : Supplying installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia
od149137/2021_2022 : Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required
od149139/2021_2022 : Supply,Installation,Testing and Commissioning of Pressure switch bellow type of approved make.<br>
od149140/2021_2022 : Supply, Installation,Testing and Commissioning of Pressure gauge with 0 to 200PSI,25 mm dia.<br>
od149141/2021_2022 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings.-25 mm dia<br>
od149142/2021_2022 : Supplying, fixing, testing and commissioning of following NON - RETURN VALVE of C I body vulcanized NBR seal flanged end & PN16 pressure rating as specified -25 mm dia<br>
HYDRANT SYSTEM
od149061/2021_2022 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required for internal
od149066/2021_2022 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required for internal. for external
od149073/2021_2022 : Supply & Installation of GM short branch pipe conforming to IS: 903 of I S I mark with 63 mm dia instantaneous coupling on one end and nozzle spray or fog type.<br>
od149077/2021_2022 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses,and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside.<br>
od149082/2021_2022 : Supply, installation, testing and commissioning of 63mm dia 15 M long non percolating flexible and light weight synthetic fire fighting delivery hose with textile reinforcement, resistant to chemicals, acids, alkalis, abrasions, heat and ozone having 36Kg/cm 2 burst pressure including gunmetal make and instantaneous type coupling approved by fire authority, machine would with copper wire complete in all respects.<br>
od149090/2021_2022 : Supply,Installation, Testing and Commissioning of swing type Hose reel drum made of 16 gauge MS sheet to keep 19 mm dia 30 Mtrs long PVC lined rubber braded hose pipe with chrome plated nozzle on one end and all other necessary fixing materials.<br>
od149092/2021_2022 : Supply, installation, testing and commissioning of Fire Brigade Inlet connection with 3 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type in a 16 swg Ms cabinet size 1000 x 300 x 400 .<br>
od149102/2021_2022 : Supply,Installation,Testing and Commissioning of Air Release Valve GM 20mm dia type of approved make.<br>
od149103/2021_2022 : "Hydrant valve Chamber: Brick masonry chambers in cement mortar 1:5 (1 cement: 5 Coarse sand) on cement concrete foundations 150mm thick 1:4:8 mix (1 cement: 4 fine sand: 8 graded stone aggregate 40mm nominal size) 15mm thick cement plaster inside and outside finished with a floating coat of neat cement inside with cast iron surface box approved by local fire brigade including excavation, back filling complete. Valve chambers shall be of following sizes:<br>For depths up to 1mtr. 450mm X 450mm<br>For depths up to 1mtr. & beyond 1000mm X 1000mm"<br>
HYDRANT PIPE
od149093/2021_2022 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata100 mm dia<br>
od149104/2021_2022 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.150 mm dia<br>
od149108/2021_2022 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata 80 mm dia<br>
od149112/2021_2022 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.100 mm dia<br>
od149116/2021_2022 : Under ground piping : Supply,installation Testing and Commissioning of GI C class pipe of following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials. The rate is inclusive of excavation & wrapping with approved wrapping tape of 4mm thickness.80 mm dia<br>
od149120/2021_2022 : ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials) : Jindal/Tata150 mm dia<br>
FIRE SPRINKLER SYSTEM
od149065/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 100 mm dia"<br>
od149069/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 80 mm dia "<br>
od149085/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 65 mm dia"<br>
od149088/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 50 mm dia "<br>
od149094/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 40 mm dia"<br>
od149099/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 32 mm dia"<br>
od149106/2021_2022 : "ABOVE GROUND :SUPPLY, INSTALLATION, TESTING & COMMISSIONING of GI heavy duty grade 'C' class pipe (IS:1239 Part-I) including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. (Make Of Materials : Jindal/Tata<br> 25 mm dia"<br>
od149114/2021_2022 : "Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius.K 115 for basements& K 80 for other areas. Pendant type sprinkler<br>"<br>
od149118/2021_2022 : "Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius.K 115 for basements& K 80 for other areas. Sidewall sprinkler type"<br>
od149119/2021_2022 : "Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius.K 115 for basements& K 80 for other areas.Upright sprinkler type"<br>
od149122/2021_2022 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 10, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.above 150 mm dia limit switches 100 mm dia<br>
od149126/2021_2022 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 10, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.above 150 mm dia limit switches 80 mm dia<br>
od149127/2021_2022 : Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 10, OS & Y type confirming to IS 5312 with CI wheel and necessary fittings.50 mm dia ( for sprinkler drain)
od149129/2021_2022 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 100 mm dia<br>
od149131/2021_2022 : Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable. 80mm dia<br>
od149135/2021_2022 : Supply, Installation,Testing and Commissioning of Sprinkler Flexible Drrop type of approved make. 1000 mm <br>
od149136/2021_2022 : Supply, Installation,Testing and Commissioning of Sprinkler Flexible Drrop type of approved make. 1200 mm <br>
od149138/2021_2022 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings. 25 mm dia<br>
FIRE ALARMS (ADDRESSABLE) SYSTEM
od149058/2021_2022 : Supply, Installation, Testing & Commissioning of Analogue Addressable Fire Alarm Panel with 2 loop including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module and fire device loop.Each Loop capable of connecting 99 detectors and 99 modules 99 devices. The panel shall have 2x12v/12 Ah SMF Battery (or more), Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit, complete in all respects. operation of speakers. The Panel shall have :Loop connected devices include detectors, call-points, loop isolators, Hooter.
od149075/2021_2022 : Supply,Installation,Testing and Commissioning of Intelligent Addressable Heat Detector with base, base box etc.The detector shall be suitable for both rate of rise and fixed temperature.<br>
od149076/2021_2022 : Supply,Installation,Testing and Commissioning of Sounder cum Strobe Lights with 110 cd. The strobes shall be synchronized for better evacuation as per specification complete as required. Control Modules to activate Hooter/strobes should be taken into consideration.<br>
od149084/2021_2022 : Supply, Installation,Testing and Commissioning of analog addressable type Manual pull station at indicated locations with necessary termination as per acceptable specifications and full ready for operation.<br>
od149089/2021_2022 : Supply,Installation,Testing and Commissioning of Short Circuit Isolator Module for isolating the affected segment of the circuit, allowing the remaining devices to continue operation.<br>
od149095/2021_2022 : Supply, installation, testing and commissioning of Analogue Addressable type Optical Smoke Detector (photoelectric type) complete with all accessories like base. base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. (below false ceilng)<br>
od149101/2021_2022 : Supply,Installation,Testing & Commissioning of Analogue Addressable Response indicator including all accessories compatible with all the fire detectors required for complete installation.<br>
od149105/2021_2022 : Supply, installation, testing and commissioning of Analogue Addressable type Optical Smoke Detector (photoelectric type) complete with all accessories like base. base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. (above false ceiling)<br>
od149110/2021_2022 : Supply, Installation,Testing and Commissioning of addressable control relay module for hooters at different locations complete with all fixing accessories. <br>
od149111/2021_2022 : Supply of Intelligent Addressable control relay modules for AHU & stairs pressurization Fan, Access control integration etc. complete as required as per specifications<br>
od149117/2021_2022 : Supply,Installation,Testing and Commissioning of Intelligent Addressable monitor modules for Sprinkler Flow Switch, Fire doors, magnetic contacts & WLD monitoring complete as required as per specifications , Make: morley<br>
od149121/2021_2022 : Supply, laying, testing and commisioning and making terminations for 2 Core x 1.5 Sq.mm cable, Armoured Screened FRLS Twin Twisted PVC Insulated copper cable along with all accessories required for complete installation, making terminations etc where required <br>
Two Way Talk Back &amp; Public Address system
od149079/2021_2022 : Supply , installation , testing and commisioning of Public Address speaker with talk back facility 12 Watts with LMT and call switch , made out of powder coated CRCA sheet , wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting. <br>
od149091/2021_2022 : Supply,Installation,Testing and Commissioning of 4 core x 1 sq.mm copper wires PVC sheathed with ISI mark.<br>
od149096/2021_2022 : Supply and laying of 25MM Dia PVC conduit pipes with ISI mark and with all the accessories.<br>
Fire rated doors
od149063/2021_2022 : Providing and fixing of Sheet metal duct door for the fire duct size 1500 X900mm ,fabricated from 16SWG GI CR Sheet & 18SWG shutter, sheets fully powder coated as per standard colour requirements of the Client with door handle, hinges and locking arrangements.<br>
Signages
od149059/2021_2022 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Floor indentification signages (ie,GROUNDFLOOR,FIRSTFLOOR,…etc.) at each stair enclosure on every floor,indicating the floor number in words,lettering size shall be7.5cm with contrasting colour from background.<br>
od149064/2021_2022 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Signage with printed IN CASE OF FIRE DO NOT USE LIFT,USE THE STAIRS,of 1.25 cm height letters in red with white background. The board shall be fixed at the height of 2 mts. from finished floor near lifts.<br>
od149071/2021_2022 : Providing and installation in position self glowing Signage with printed FIRE EXTINGUISHER /FIREHYDRANT /FIREFIGHTING EQUIPMENTST OREDINSIDE, of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts.<br>
od149078/2021_2022 : Providing and installation in position self glowing "FIREEXIT" / "EXIT" signboard swith directional arrow markings of made of luminescent safety ,rigid sheet in green colour,photoluminescent type Samples has to be approved by the Architect before procuring the same.<br>
od149080/2021_2022 : Supply and installation in position self glowing Signage with printed IN CASE OF FIRE BREAK GLASS, of 1.25cm height letters in red with white background.The size of the board shall be 10x15 cm and shall be fixed at the height of 2 mts. from finished floor near the Manual Call Points.<br>
od149087/2021_2022 : Supply and installation of in position the signages "FIREORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinylepainted foamboard of 3'x4'. Samples has to approved by the Architect before procuring the same.A) ALERT THE SECURITY BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY, AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE FIRE EXTINGUISHER OR WATER FROM NEAREST HOSE REEL. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION ,LAY FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. F) TRY TO COVER YOUR FACE WITH A WET TOWEL TO AVOID BREATHING SMOKE OR OTHER TOXIC FUMES. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANYONE OF THE FOLLOWING PHONE NUMBERS:101 /………………….( Local fire station number) C) REFER EVACUATION PLAN.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF CASUALTIES, CALL AMBULANCE (Local numbers:) PHONE : -----------------------<br>
od149097/2021_2022 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building.<br>
od149100/2021_2022 : Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional.<br>
FIRE EXTINGUISHERS
od149074/2021_2022 : Supply and fixing of ABC Powder based Fire Extinguisher of capacity 2 kg filled with Mono Ammonium Phosphate with nitrogen as per IS 15683with control dis mechanism, Supplied with standard accessories.<br>
od149083/2021_2022 : Supply and fixing of 9Kg Mechanical foam Type Fire Extinguisher storred pressure, Design, construction and testing as per IS 15683 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.<br>
od149098/2021_2022 : Supply and fixing of 2kg class K (wet chemical) Type Fire Extinguisher storred pressure , Design, construction and testing as per IS 15683 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.
od149107/2021_2022 : Supply and fixing of 2Kg CO2 (Portable) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories
od149109/2021_2022 : Supply and Fixing of 4.5Kg, CO2 Gas Type Fire Extinguisher, Trolley Mounted, Used Unused Mechanism, Squeeze Grip, Gross Weight 19.20 Kg, Empty Weight 4.725 Kg, Can Height 870MM, Diameter 140MM, Discharge time minimum 13 Seconds, Controllable discharge mechanism, Range minimum 2 Meters, Applicable on Class B,C & electrically started Fire, EN RATING- B Rating 55B Can Construction : Hot Spinning Process, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, Mild Steel,External Coating of Can : Spray Painting, CE & PESO Approved, BSI and PED Certified,
od149113/2021_2022 : Supply and fixing of ABC Powder based Fire Extinguisher of capacity 4 kg filled with Mono Ammonium Phosphate with nitrogen as per IS 15683with control dis mechanism, Supplied with standard accessories.
od149115/2021_2022 : Supply and fixing of 2 Kg Fire Extinguisher Clean Agent HFC 236 FA, Stored Pressure Type, Pressure Gauge, Ozone Depletion Potential Zero, Gross Weight 3.7 Kg, Empty Weight 1.7 Kg,, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2 Meters IS 15683
od149123/2021_2022 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 4 nos of fire buckes, or , duly painted over a coat of primer.<br>
Oxygen Supply System
od149312/2021_2022 : Supply, Installation, Testing and commissioning of fullyautomatic Oxygen Control Panel with minimum flow rate of 925 LPM<br>
od149327/2021_2022 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 10 cylinders with all accessories etc
od149337/2021_2022 : Supply, Installation, Testing and commissioning of Emergency Cylinder Manifold 2 bank x 2 cylinders with emergency Oxygen high flow regulator with gauges and safety valves with all accessories etc.
Nitrous Oxide Supply System
od149325/2021_2022 : Supply, Installation, Testing and commissioning of Semi automatic N2O Control Panel with minimum flow rate of 95 LPM
od149334/2021_2022 : Supply, Installation, Testing and commissioning of N2O Manifold - 2 banks x 4 cylinders with all accessories etc.
od149338/2021_2022 : Supply, Installation, Testing and commissioning of Emergency N2O Cylinder Manifold -1 bank x 2cylinders with emergency N2O high flow regulator with gauges and safety valves with all accessories etc.
Carbon dioxide Supply System
od149313/2021_2022 : Supply, Installation, Testing and commissioning of Semi automatic CO2 Control Panel with minimum flow rate of 40LPM
od149330/2021_2022 : Supply, Installation, Testing and commissioning of CO2 Manifold - 2 banks x 1 cylinders with all accessories etc.
Compressed Air Plant
od149316/2021_2022 : Supply, Installation, Testing and commissioning of Duplex Mediacl grade compressed Air System must have 2 nos Screw/Scroll oil free medical grade air cooled compressor in compact super sound absorbing tower design complete with all required cooling, control and monitoring facilities for operations in system with 2 compressors, a control panel, 1 air receivers 1500 L., 2 Dryer and filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station, electrical control panel etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to the European Pharmacopoeia as per the tech spec.. Each compressor should have minimum FAD of 1417 LPM (50CFM).
Vacuum Plant
od149319/2021_2022 : Supply, Installation, Testing and commissioning of Medical grade Duplex Vacuum System must have 2 rotary vane type vacuum pumps directly driven by motor, a control panel, 1 vacuum receivers 2000 Ltr., secretion Trap and bacteria filter, electrical control panel etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99. each vacuum pump should have FAA 2045 LPM at 450mmHg,
WAGD SYSTEM
od149322/2021_2022 : Supply, Installation, Testing and commissioning of pendant operated WAGD SYSTEM (meeting ISO 7396-2/HTM02-01)
Area control unit (Area alarm + Area valves)
od149323/2021_2022 : Area Control Unit for 1 Gases (O2) and 1 Vac (DN 20)
od149326/2021_2022 : Area Control Unit for 2 Gases (O2, Air) and 1 Vac (DN 20)
od149346/2021_2022 : Area Control Unit for 4 Gases (O2, Air4, Air 7,N2O) and 1 Vac
od149350/2021_2022 : Area Control Unit for 5 Gases (O2, Air4, Air 7,N2O, CO2) and 1 Vac
Isolation valves
od149314/2021_2022 : Ball Valve, DN 15 - 15x1
od149333/2021_2022 : Ball Valve, DN 20 - 22x1
od149340/2021_2022 : Ball Valve, DN 25 - 28x1,5<br>
od149347/2021_2022 : Ball Valve, DN 32 - 35x1,5<br>
od149351/2021_2022 : Ball Valve, DN 40 - 42x1,5
od149353/2021_2022 : Ball Valve, DN 42 - 54x1,5<br>
od149355/2021_2022 : Ball Valve, DN 50 - 76x1,5<br>
Terminal units Wall mounted - BS standard
od149321/2021_2022 : Terminal Unit O2
od149331/2021_2022 : Terminal Unit N2O
od149341/2021_2022 : Terminal Unit Air 400
od149344/2021_2022 : Terminal Unit Air 700
od149348/2021_2022 : Terminal Unit Vac
od149352/2021_2022 : Terminal Unit CO2
od149357/2021_2022 : Probes<br>
Bed head panels
od149324/2021_2022 : Horizontal Bed Head Panels of 3 feet long with provision for 3 nos electrical (power & data) & min 3 nos Gas outlets - as per technical specification for Post operative beds
od149329/2021_2022 : Horizontal Bed Head Panels of 4 feet long with provision for 3 nos electrical (power & data) & min 5 nos Gas outlets - as per technical specification for ICU beds
od149342/2021_2022 : Continous Bed head panel with provision for fixing Medical gas outlets, power sockets, nurse cal points etc. as per the design requrement.
Pendants
od149315/2021_2022 : Anaesthesia Pendant - Single Arm
od149328/2021_2022 : Surgeon's Pendant - Single Arm
Medical Equipments
od149320/2021_2022 : Supply, installation, testing and commissioning of Oxygen Flow meter with humidifier bottle. Matching probe / adaptor shall be provided at one end suitable for Oxygen Gas Outlets and other end for flow meter.
od149335/2021_2022 : Supply, installation, testing and commissioning of Ward Suction Unit with 1200 ml suction jar as per specifications. Matching proble / adaptor shall be provided at one end suitable for vacuum gas outlets and other end for Vacuum Hose.
od149343/2021_2022 : Supply, installation, testing and commissioning of Theatre Suction Unit with 3200 ml jars as per specifications. Matching probe / adaptor shall be provided at one end suitable for Vacuum Gas outlets and other end for Vacuum Hose including trolley.
Master plant alarm
od149318/2021_2022 : Master plant alarm<br>
Copper Piping As per EN13348 standards.
Biogas Plant
od149311/2021_2022 : Supply, installation, testing and commissioning of 10 cum biogas plant with a waste treatment capacity of 50kg/day. The rate shall be inclusice of all safety devices and accessories required for complete installation as required.<br>
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level
5.34.1 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
od146331/2021_2022 : Providing sand filling for soak pit
od146332/2021_2022 : Supply, Installation, Testing & Commissioning of Coarse Screen for sewage MoC: SS 304, Angle of Inclination – 45 deg, Frame in 1” Square Pipe and Bars made of 10 mm Square Pipe with 12 mm Spacing with suitable facility to remove trapped materials.<br>
od146333/2021_2022 : Supply, Installation, Testing &Commissioning of Twin Lobe Blower with Motor Continuous Duty, Operating Discharge of 60 m3/hr or above, with differential Pressure of 4 m WC, With three phase Motors with Power: 3.0 HP, pulley fixed on a frame with Inlet / Outlet Silencers and Header Piping as required in MSEP, in a configuration of 1 Working & 1 Standby, also with Outlet Pressure monitoring, Pressure Relief Valves, Check Valves, Hand Valves & all required accessories etc. Complete. <br>
od146334/2021_2022 : Supply, Installation, Testing & Commissioning of Aeration Grid with Fine Bubble Diffusers in MBBR tank. Disc or Tube Type Coarse Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 8 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required in Equalization tank, Chemical precipitation tank etc. <br>
od146335/2021_2022 : Supply, Installation, Testing & Commissioning of Aeration Grid with Coarse Bubble Diffusers Disc or Tube Type Coarse Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 8 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required in Equalization tank, Chemical precipitation tank etc. <br>
od146336/2021_2022 : Supply, Installation, Testing & Commissioning of Raw sewage transfer pump Submersible Sewage Transfer Pumps(cutter pump), Continuous Duty, Minimum Discharge of 50 LPM, or above, with 10 m Head, three phase with Power: 1.0 HP,in a configuration of 1 Working & 1 Standby, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete<br>
od146337/2021_2022 : Supply, Installation, Testing & Commissioning of Fine Screen for sullage MoC: SS 304, Bucket Type Screen, Frame in 1” Square Pipe and Perforated Sheet with 6 mm Spacing with suitable facility to remove trapped materials.<br>
od146338/2021_2022 : Supply, Installation, Testing & Commissioning of plumbing interconnections considering a plant room with in 5 m nearby STP Airline Header: GI/MS, Air line after header UPVC-ASTM, Pressurized Water & Wastewater lines - UPVC-ASTM, Overflow Conduits / Gravity Lines – PVC 10 kg/cm2, Ball Valves - UPVC, Gate & Globe Valves – Brass,Slotted Chanel & Rod – GI <br>
od146339/2021_2022 : Supply, Installation, Testing & Commissioning of Electrical Cables considering a plant room with in 5 m nearby STP. Cables of approved make 4Core 10 mm2, Aluminium Armored Cable, 2.5 mm2- Flexible Cu Cable, 1.5 mm2-Cu CableFlexible <br>
od146340/2021_2022 : Supply, Installation, Testing & Commissioning of Electrical control panel: suitable for both automatic & Manual operation STP Panel board fabricated out of 14/16 SWG CRCA sheet, powder coated, compartmentised, free standing, floor mounted, dust and vermin proof with reinforcement wherever necessary fully meeting all the requirement specified in the technical specifications and drawings. Galvanized hardwares with zinc passivation shall be used. TPN switch gear shall be supplied with equally rated neutral link. All indication lamps should be LED type, all MCCBs should be with rotary handle.The panel shall be fabricated as per IS standards and KSEI specifications by a CPRI approved vendor. All Switch gear- MCB, OLR, Single Phase Preventer, H/L Protection, Volt meter, Push Button, Indication Lamp ,TOD energy meter, flow meter etc of approved Make for Level based On-off Control Valves provided with float switch etc.<br>
od146341/2021_2022 : Supply, Installation, Testing & Commissioning of Activated Carbon Filter Working Pressure : 2.5 - 3.0 Bar, MoC: FRP Composite, Flow Rate: 4 m3/hr, Media Type: Activated Carbon with IV – 900, Silex and Pebbles, Diameter - 24", Height - 72", Process Connection - T&B, Valve type: Multiport Valve -1.5", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete<br>
od146342/2021_2022 : Supply, Installation, Testing & Commissioning of Pressure Sand Filter Working Pressure : 2.5 - 3.0 Bar, MoC: FRP Composite, Flow Rate: 4 m3/hr, Media Type: Sand & Pebbles, Diameter - 24", Height - 72", Process Connection - T&B, Valve type: Multiport Valve -1.5", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete<br>
od146343/2021_2022 : Supply, Installation, Testing & Commissioning of Filter Feed Pumps MoC: Cast Iron, Duty: Continuous, Packing: Mechanical Seal, with a Flow Rate of min 50 LPM or above at a Head >25 m In a configuration of 1 Working & 1 Standby, Power- 1.5 HP, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete<br>
od146344/2021_2022 : Supply, Installation, Testing & Commissioning of Sludge Transfer Pump Non Clog Self Priming Type with back pull out design, MoC: CI, Packing - Non asbestos PTFE gland, Capacity 3 m3/Hr, Head - 12 m, Power- 1.0 HP, in a configuration of 1 Working with No Standby<br>
od146345/2021_2022 : Supply, Installation, Testing & Commissioning of Electronic metering pumps Diaphragm Type Electronic Dosing Pump, MoC: PP, Foot Valve, Suction/Discharge LDPE Tubing, Strokes: Manually Regulated, Pressure: 0.0-3.5 kg/cm2, PE Storage Tank - 50 L and all accessories complete.<br>
od146346/2021_2022 : Supply, Providing in Position, Testing & Commissioning of Anaerobic Bio media in up flow anaerobic tank Minimum Specific (0.3m and 0.4mm thick PVC corrugated media) Surface Area of 150 m2/m3, MoC: PVC, Type –Corrugated Sheets <br>
od146347/2021_2022 : Supply, Providing in Position, Testing & Commissioning of Aerobic Bio media for MBBR Tank Minimum Specific Surface Area of 600 m2/m3, Voidage - 95%, MoC: Virgin PE (Preferably Imported), Type - Cylindrical,Size: 25mm X 12mm <br>
od146348/2021_2022 : Design prepration Preparation of Installation and as built drawings for the Project, SOPs, Operating Manuals and Detailed Engineering <br>
od146349/2021_2022 : Supply, Providing in Position, Testing & Commissioning of tube settler media in secondary settling tank. Minimum Specific (1mm thick PVC of unequal hexagonal shape)<br>
od283783/2021_2022 : Supply, Installation and Commissioning of FILTER PRESS including all fittings & accessories of P.P. Ceramic Design (Open Delivery), Plate size - 24”x24”, No. of plates - 15 nos, No. of chambers - 14 nos, Cake holding capacity - 149.8 litres of water equivalent, Filtration area - 8.54 Sq. m, Operating Pressure - Up to 8 Bar, Plate shifting - Manual, Type - Recessed, Material - Polypropylene, Virgin, Thickness - 73 ± 5 mm, Cake thickness - 40 ± 3 mm, Feeding - Center Inlet, Discharge - Single side open (Tap Outlets), Surface - Piped buttons, Filter cloth - P.P Filter cloth (2 Micron), Structure - Mild steel, Plate closing - Hydraulic Manual Jack Cap.25 Ton, Holding capacity - 200 to 250 Kg / Sq.cm, Stroke - 150mm, Power pack - -NIL-, Motor for S. S. Screw - 11/2” HP S.S 316 Screw pump coupled with 2 HP motors with base & belt driven 500 RPM bearing housing CI body nitrile rubber, Inlet Line - complete S.S. with 2” P.P. Flange End Connection.
od146350/2021_2022 : "Supply, Installation, Testing & Commissioning of Ultra-Filtration Plant Incl. Skid, Dosing Pumps, Solenoid Valve based Operation and PLC based Control, Capacity - 3 m3/hr, with Low Pressure Membrane,UF module-3500ltr/hr Flux Rate for Design – 50 LMH, Pressure Vessel rating 10 Bar, with Feed Pumps SS-3500Litres/hr @2Kg/cm2,<br>SS 304 body & impeller (1 Working+ 1 Standby), Backwash Pumps- 10000Litres/hr @ 2Kg/cm2<br>SS Pumps(1 Working), CIP Pump in SS 304 Construction (1 Working), 20” Jumbo Cartridge Filters in the Inlet and in CIP Inlet Lines, Dosing Arrangements, Chemical Tank-250ltrs, Check Valves, Hand Valves, Pressure Guages,Pressure switches-high and low,Flow meter-3500ltr/hr , Rotameters for Flow Monitoring etc Complete. "<br>
od146351/2021_2022 : Supplying and fixing C.I cover with frame for manholes: 500mm dia C.I cover (<br>medium duty ) the<br>weight of the cover to be no less than 58 kg
STP Pump Room
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work above plinth level upto floor V level
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
10.10.1 : Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Operation Theater
od149304/2021_2022 : Supply and installation of Imported Vinyl Floor: Seamless antistatic conductive ESD vinyl flooring system, 2mm thick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting, but excluding base PCC/ VDF and 3mm self levelling.<br>
od149305/2021_2022 : Supply, Installation, Testing and Commissioning of Single arm moveable pendant with 900mm long arm in heavy duty aluminium extrusion profile having weight carrying capacity of more than 150Kg, Console 1100mm long in aluminium extrusion, Eight modular electrical switched sockets 6/16 ampere, Three equipment shelf duly powder coated in aluminium frame, one drawer and indian gas outlets.<br>
od149307/2021_2022 : Supply, Installation, Testing and Commissioning of 2 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish having front acess panel with Elbow Operating<br>
od149308/2021_2022 : Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel (6 services) ,mounted flush in the theatre wall alongwith Distribution Board comprising of the following : -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) - Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel (6 services) ,mounted flush in the theatre wall alongwith Distribution Board comprising of the following : -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) - Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Control<br>
od149309/2021_2022 : "Providing, Fixing, Supply & installation of Pre Fabricated Modular Operation Theatre with 0.8 mm 304 grade Stainless Steel sandwhich has been injected under high pressure, with a minium density of 40kg/m3. & Antifungal paint ,wall glaze or equivalent to a minimum dry film thickness of 300 microns having overlap floor covering ,ceiling system and door frames by 25mm to provide a continous sealed surface ( for wall & ceiling )<br>"<br>
od149310/2021_2022 : UV Light<br>
od290028/2021_2022 : Supply, Installation, and Commissioning of Manually Operated Hermetically Sealing Sliding door, having<br>high pressure laminate on both sides that could withstand high abrasion, vision panels (300x300mm) , for<br>smooth sliding .The door moves on nylon wheels within an single piece aluminium extruded track. Size is<br>(1500 x 2100 )
CCTV SYSTEM
od76274/2021_2022 : Supply, Installation,testing and commissioning of 2.8 mm fixed lens, 2MP , IR Dome camera 1.0 lux, 120 db WDR POE and vandal proof with all connectors and necessary accessories for mounting in True/false ceiling<br>
od76277/2021_2022 : Supply, Installation,testing and commissioning of Varifocal Dome Camera with 2 MP 0lx, built-in IR LED,120DB WDR , 2.8-12 mm POE,Vandal proof with all connectors and necessary accessories for mounting on true/false ceiling <br>
od76282/2021_2022 : Supply, Installation,testing and commissioning of Outdoor type Varifocal Bullet Camera with 2 MP 0lx, built-in IR LED,DWDR , 2.8-12 mm POE ,IP 67 ,Vandal proof with all connectors and necessary mounting accessories for external areas. <br>
od76289/2021_2022 : Supply, installation, testing and commissioning of 32 Channel Network Video Recorder Supports 32 channels 1080p resolution video recording at real time, NVR ONVIF , Recording resolution of Max 5 MP, Minimum of 200Mbps of recording, should support dual video output,H265+, H.265,H.264, MJPEG Compression.video playback / relay at real time. <br>
od76291/2021_2022 : Supply, installation, testing and commissioning of HDD for cameras recording at 1080p @ 12fps for 30 days 24 hours - 6 TB<br>
od76294/2021_2022 : Supply, installation, testing and commissioning of workstation with Intel I7 or above, 8 GB ram and 2 TB HDD. Same system will be used for Access control<br>
od76299/2021_2022 : Supply, Installation, Testing and Commissioning of LED Monitor 40" with all required accessories<br>
od76303/2021_2022 : Supply, Installation,testing and commissioning of Indoor Varifocal Bullet Camera with 2 MP , built-in IR LED, 2.8-12 mm POE , IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling<br>
PA SYSTEM
od76272/2021_2022 : Supply & Installation of 15W Horn Speaker for PA system<br>
od76275/2021_2022 : Supply & Installation of Wall mount 6/9/12W Speaker for PA system<br>
od76281/2021_2022 : Supply & Installation of ceiling mount 6W Speaker for PA system.
od76290/2021_2022 : Supplying, installing, testing and commissioning Audio booster Amplifier 240<br>Watts RMS, complete with Speaker wires and RGB connectors for Integrated<br>Music & PA system.
od76295/2021_2022 : Supply & Installation of Master Controler for managing and controlling upto 6 zone should be able to integrated with FAS.<br>
od76298/2021_2022 : Supply & Installation of 6 zone call station with mic<br>
od76307/2021_2022 : Wiring of Speaker system using 2core of 1.5sqmm PVC insulated copper FRLS<br>unarmoured cable.
od76310/2021_2022 : Supply, installation, testing & commissioning of Audio player with DVD/USB/FM connectivity option for playing music<br>
Passive
od76273/2021_2022 : Supply, laying, testing & commissioning of Cat 6 cable.
od76279/2021_2022 : 24 Port Cat6 Patch Panel with all accaessories loaded with copper uplink 1G<br>
od76283/2021_2022 : Supply, fixing, testing, and commissioning of Cable Manager.
od76287/2021_2022 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter as required for complete installation.<br>
od76292/2021_2022 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter as required for complete installation.<br>
od76296/2021_2022 : Supply, fixing, testing and commissioning of CAT6 Information Outlets for Data with faceplate, Keystone Jack etc. as required for complete installation.<br>
od76300/2021_2022 : Supply, fixing, testing and commissioning of Keystone jack for data outlets (for Camera points) as required installation.<br>
od76304/2021_2022 : 19", 9U 500 MM wide x 550 MM Depth Wall Mount Networking Rack with Front<br>Glass Door, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No,<br>Horizontal PDU 6X5Amps - 1 No, Cooling Fan - 2 Nos, Hardware Screws and all<br>other required accessories
od76306/2021_2022 : 19", 22U 600 M M Wide X 800 M M Depth Floor M ount Networking Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, M ounting Hardware Screwsand all other required accessories<br>
od76309/2021_2022 : 19", 42U 800 MM Wide X 800 MM Depth Floor Mount Network Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, M ounting Hardware Screwsand all other required accessories<br>
Switches
od76271/2021_2022 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T Network switch with 24 port PoE 1G copper uplink and all related termination accessories as per vendor specific System requirement. 24 Port PoE Switch <br>
od76280/2021_2022 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T<br>network Switch with 1G copper uplink 24x 1G ports and all related termination<br>accessories as per vendor specific System requirement. 24 Port Switch.
od76284/2021_2022 : Supply, Installation, Testing & Commissioning of 8 port 10/100/1000 Base-T Manegable L3 Core Switch with 10G fibre uplink 8x 1G copper ports and all related termination accessories as per vendor specific System requirement. 8 Port Switch <br>
EPBAX
od76276/2021_2022 : Supply, installation, testing and commissioning of single line master console phone with 5 navigation keys with necessary connection as required for complete installation.<br>
od76285/2021_2022 : Supply, installation, testing and commissioning of Digital phone with necessary connection as required for complete installation as directed by the engineer in charge.<br>
od76288/2021_2022 : Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge.<br>
od76297/2021_2022 : Supply and fixing 20 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br>
od76301/2021_2022 : Supply and fixing 10 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br>
od76302/2021_2022 : Supply and laying 20 pair telephone cable<br>
od76305/2021_2022 : Supply and laying 10 pair telephone cable<br>
od76308/2021_2022 : Supply and installation of modular type telephone socket outlet mounted in seperate PVC box including supply of modular PVC mounting box, telephone socket covering with modular coverplate giving connection etc as required. <br>
od76311/2021_2022 : "Supply, Installation, Testing and Commissioning of ""PBX with 54 Analog extensions expandable up to 75 ports,3 Digital Extensions and maximum of 10 concurrent calls Network Interface: 1×10/100M LAN port, 4 CO Trunk, Failover Function (optional), Web Interface, Call Dashboard, DISA, IVR, Call Hunt etc. <br>Remote Inspection, with auto-emergency call<br>Built-In Auto Answer<br>(Standby mode) during night mode<br>PRI compatibility, Voice Mail Integration<br>Paging Announcement<br>Programmable Function Keys"""<br>
od76312/2021_2022 : Supply and fixing 100 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box<br>
od76313/2021_2022 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.<br>
MISSCELLANEOUS
od76270/2021_2022 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br>150 mm width X 50 mm depth X 1.6 mm thickness<br>
od76278/2021_2022 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br>100 mm width X 50 mm depth X 1.6 mm thickness<br>
od76286/2021_2022 : Supplying and installing following size of perforated GI cable trays with perforation<br>not more than 17.5%, joined with connectors, suspended from the ceiling with GI<br>suspenders including bolts & nuts, required bends, tees, reducers etc as<br>required.<br>50 mm width X 50 mm depth X 1.6 mm thickness.
od76293/2021_2022 : Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. (OBO Betterman make or equivalent)<br>
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Incinerator
od149303/2021_2022 : Supply, erection, installation and commissioning of diesel run incinerator with 50-100kg capacity and 100 feet chimney supported with MS angle tower as per PCB norms with lightning arrester and aviation lamp. The incinerator shall be of primary and secondary chamber model with SS Scruber, recirculating tanks, pumps and all related accessories. The rate shall be inclusive of lightning arrester with copper flats, aviation lamps with connections and ceramic plugs but excluding earthing.
Compound wall
15.9.1 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortor
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
od146356/2021_2022 : Random rubble masonry using departmental rubble with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:<br>Cement mortar 1:6 (1 cement : 6 coarse sand)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
od146358/2021_2022 : Solid block masonry using pre cast Fly ash solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Basement floor exhaust pipe
od146355/2021_2022 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
FLOOR HVAC
od149143/2021_2022 : 1.H Central remote controller
od149146/2021_2022 : 1.G 18 HP Out door unit<br>
od149148/2021_2022 : 1.F 20 HP Out door unit<br>
od149151/2021_2022 : 1.D 8.0 TR High static Ductable.
od149154/2021_2022 : 1.B 2.0 TR One way cassette unit<br>
od149156/2021_2022 : 1. SPLIT UNITS DX TYPE<br><br>Supply, installation, testing and commissioning of inverter type VRF Units complete with indoor & outdoor as per specification, each complete with filter, inverter scroll Compressors, condensers, evaporator, fan and Motor with Hi-Low speed control along with R-407C / 410a refrigerant charge, decorative panel, cordless remote, etc ..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. The unit shall be designed to take care of minimum vertical Head 5 meter and total length of 40 meters. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br><br>1.A 1.5 TR One way cassette unit
od149158/2021_2022 : 2.H 34.9 mm Dia<br>
od149159/2021_2022 : 2.G 28.6 mm Dia<br>
od149161/2021_2022 : 2.F 22.2 mm Dia<br>
od149163/2021_2022 : 2.E 19.1 mm Dia<br>
od149164/2021_2022 : 2.D 15.9 mm Dia<br>
od149165/2021_2022 : 2.C 12.7 mm Dia<br>
od149166/2021_2022 : 2.B 9.5 mm Dia<br>
od149167/2021_2022 : Supply,Installation and commissioning of copper refrigerant piping, complete with 19 mm thick closed cell Class O Nitrile Rubber Insulation , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works. Refrigerant piping to be measured based on the distance between the indoor and outdoor units irrespective of number of circuits. The piping will be measured as one length for suction and liquid line. Insulation will be measured along with the piping and not be claimed as extra. Copper tubes, shall be with thickness conforming to L type to ATM standards.The tubes shall be bright annealed copper upto and including 15 mm size.<br><br>2.A 6.4 mm Dia<br>
od149169/2021_2022 : 2.I Supply,Installation and commissioning of copper ruff nut joint with insulation , all necessary support and accessories<br>
od149171/2021_2022 : 3. DRAIN PIPE<br>Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation.<br><br><br>3.1 20 MM Dia
od149172/2021_2022 : 3.2 25 mm Dia
od149175/2021_2022 : 4. VENTILATION AND SHEET METAL WORK<br><br> Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. The Kitchen, laundry,, sataircase pressurisation fans shall be axial/mixed flow, motor out of air stream(as applicable) as specified and as indicated in the equipment schedules and drawings for the following:<br><br><br><br>4.A 450 CFM,190 PASCAL<br>
od149176/2021_2022 : 4.B 700 CFM,130 PASCAL<br>
od149179/2021_2022 : 750 CFM,130 PASCAL
od149180/2021_2022 : 4.C 800 CFM,130 PASCAL
od149182/2021_2022 : 4.D 200 CFM<br>
od149185/2021_2022 : 4.E 150 CFM<br>
od149186/2021_2022 : 4.F 160 CFM<br>
od149187/2021_2022 : 4.G Wall mounted propeller fan 250 CFM Plastic body<br>
od149188/2021_2022 : 4.I Wall mounted propeller fan 100 CFM Plastic body<br>
od149189/2021_2022 : 4.H Wall mounted propeller fan 150 CFM Plastic body<br>
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
od149190/2021_2022 : Supplying and fixing of Closed cell nitrile (Class “O”) insulation for under deck applying suitable adhesive for Nitrile rubber. The joints shall be sealed properly complete as per specifications and as required.<br><br><br><br>5.D 25 MM Thick.<br>
od149191/2021_2022 : Supplying and fixing of Open cell acoustic (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed properly complete as per specifications and as required.<br><br><br><br>5.C 10 MM Thick.<br>
od149192/2021_2022 : Supplying and fixing of closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.<br><br><br><br><br>5.B 13 MM Thick.<br>
od149193/2021_2022 : 6. TERMINAL UNITS<br><br>Supply, Installation, testing, commissioning and balancing of GSS powder coated fresh air/exhaust air louver with 4 side flanges, Bird net screen, damper arrangement and all necessary support and accessories , color should be approved by architect as per drawing. <br>
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
od149194/2021_2022 : 8.A Supply, installation, testing and commissioning of communication cabling in conduit between indoor unit to outdoor unit with necessary supports and accessories.<br>
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od149195/2021_2022 : 8.B Supply, installation, testing and commissioning of electrical cabling between indoor unit to isolator and out door unit to isolator with necessary supports and accessories.<br>
od149196/2021_2022 : Supply Installation ,testing and commissioning of dx system hi-wall unit,stabilizer, out door unit, gas charging, electrical and communication cabling,refrigerant piping with suitable insulation(up to 10 mtr) ,support with all necessary accessories,1.0TR
od248401/2021_2022 : Supply,installation, testing and commissioning of Back net Module with necessary supports and accessories.
OT HVAC
od149144/2021_2022 : 1. AIR HANDLING UNIT<br>Supply, Installation ,Testing & commissioning of floor mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, centrifugal plug fan, cleanable fabric filters of efficicency MERV 7, fine filters of efficicency MERV 14 and strip heaters , condensate drain pan (extended), coil piping connections, condensate drain connections, return air plenum with dampers, fresh air damper,flexible duct connectors, The duties of equipments listed below .All units shall be suitable for 415+/-10% volts and required lengths of wiring as per site requirement to be included. The electrical power wiring from the Isolator to the units shall be included.Units shall be installed as shown in the drawing, capacities as under:-<br><br><br>1.A 7 TR, 4370 CFM ,310 pascal<br>
od149145/2021_2022 : 1.B 6 TR, 4000 CFM, 290 pascal<br>
od149147/2021_2022 : 1.C 7 TR, 4390 CFM, 290 pascal<br>
od149149/2021_2022 : 1.D 6 TR, 3810 CFM,310 pascal<br>
od149150/2021_2022 : 2. OUT DOOR UNIT<br>Supply, Installation ,Testing & commissioning of Condensing unit with R-410A . It should include, temperature controller, and sensors along with the control box, its transformer, relays, necessary power and control wiring between the thermostat, controller, and the communication cabling between the out door and temp.controller .All the fittings associated with the unit like - but not limited to -filter, drier etc. to be considered and can not charge seperately. The capacities for the same is listed under<br><br>2.A 8.5TR<br>
od149152/2021_2022 : 3.0 DUCTED TYPE SPLIT A/C<br><br><br>3.A Supply, Installation testing and commissioning of Ducted type split/package air cooled Air-conditioners each complete with inverter type scroll compressor, air cooled condenser and evaporator with copper tubes, GSS casing, filters, cooling coils, fan motors, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Bidder to elaborate the features of Micro- processor panel. GI painted frame works for outdoor units & making good of civil work's. Bidder shall be quoted with spring type vibration isolators for indoor units for arresting the vibration transferring to the floors.The quote should be inclusive of control cabling from machine out door unit to indoor unit and from from DB to indoor unit power cabling along with earthing. This shall facilitate all functions such as ON OFF thermostat to compressor control, fan interlocks, HP/LP & AFT controls etc. And MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works. <br><br>5.5 TR DUCTABLE UNIT<br>
od149153/2021_2022 : 4. REFRIGERANT PIPING<br><br>4.A Supply,Installation and commissioning of copper refrigerant piping, complete with 13mm thick closed cell Class O Nitrile Rubber Insulation , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Refrigerant piping to be measured based on the distance between the indoor and outdoor units irrespective of number of circuits. The piping will be measured as one length for suction and liquid line. Insulation will be measured along with the piping and not be claimed as extra. Copper tubes, shall be with thickness conforming to L type to ATM standards.The tubes shall be bright annealed copper upto and including 15 mm size.<br>
od149155/2021_2022 : 5.0 DRAIN PIPING:<br>Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>
od149157/2021_2022 : 6.0 SHEET METAL WORKS:<br><br><br>Supply, installation, balancing and commissioning of fabricated at site Aluminium sheet rectangular ducting complete with rubber gaskets, elbows, splitter dampers, vanes, hangers, supports , sealent etc. as per approved drawings and specifications of following sheet thickness complete as required.<br><br><br>6.A 22 Gauge. <br>
od149160/2021_2022 : 6.B 20 Gauge (0.8MM)<br>
od149162/2021_2022 : 7.0 AIR TERMINALS<br><br><br>7.A Supply, installation, testing and commissioning of AL volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.<br>
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od149168/2021_2022 : 8.0 INSULATION<br>Supplying and fixing of closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.<br><br><br>8.A 13 MM Thick.<br>
od149170/2021_2022 : Supplying and fixing of Open cell acoustic (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed properly complete as per specifications and as required.<br><br><br>8.B 10 MM Thick.<br>
od149173/2021_2022 : Supplying and fixing of closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required External Roof and in Risers.<br><br><br>8.C 25 MM Thick.<br>
od149174/2021_2022 : 9.0 CONTROL WIRING<br><br>Supply, installation and commissioning of humidistats and control wiring between the strip heaters and humidistats with necessary accessories like relays, transformers, sensors etc.<br>
od149177/2021_2022 : Supply, installation, testing and commissioning of communication cabling in conduit between indoor unit to outdoor unit with necessary supports and accessories.<br>
od149178/2021_2022 : Supply, installation, testing and commissioning of electrical cabling between indoor unit toisolator and out door unit to isolator with necessary supports and accessories.<br>
od149181/2021_2022 : Inline Centrifugal Extract Fans shall be with direct driven centrifugal fan, Cabinet section, suitable for floor mounting whether proof body . The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. The Kitchen, laundry,, staircase pressurization fans shall be axial/mixed flow, motor out of air stream(as applicable) as specified and as indicated in the equipment schedules and drawings for the following:<br><br><br><br>1130 cfm,190 Pascal<br>
od149183/2021_2022 : 11. LAMINAR FLOW PANELS WITH HEPA FILTERS<br><br>Unidirectional Laminar flow plenum for the OT's with HEPA filters .plenum construction with 1 mm thick aluminium sheet,perforated diffuser:1 mm thick stainless stel(ss 304),19mm thick class"O" nitrile insulation with aluminium foil lamination on exterior side, 4 nos of duct connecting colar based on user requirement (maximum height 150mm/225mm),provision of upstream ports for testing and measurement,provision for OT light, SS 'L' angle brackets for ceiling suspension of the plenum. all in line with the OT standards.<br><br><br>11.A 2440 x 1830 x 450mm .<br>
Elevator
od75970/2021_2022 : Supply, installation, testing and commissioning of 20 persons passenger/bed lift; with machine room; serving 5 stops having well size of 2.20 X 3 M; one front opening with automatic power doors; complete with all standard features like direction and position indicators in car and all floors, full height infrared door curtain, pit ladder and safety curtain, inverter based emergency light and alarm, Open and Close door button in car, Fan switch in car, handrail on the rear side, mirror in the rear side, emergency rescue device, load weighing sensor, fireman drive with 2 ph operation, dedicated intercom, lift announcement system, 1 hour fire rating.<br>
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
South Indian Constructions Private Limited
Bidder Name
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
HEATHER CONSTRUCTIONS
South Indian Constructions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid