Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Reasonable bidder |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
11 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala cantt 133001
PROVISION OF BRIEFING ROOM IN TECH AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2021_MES_472331_3
CWE/AF AMB/AMB-26/2021-22
Open Tender
Civil Works
Lump-sum
180 days
AMBALA CANTT
For MES enlisted contractor Class E Category a i and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹500
GE (AF) AMBALA
₹49,800
Yes
1 Apr 2024
12 Jul 2023
13 Aug 2023
12 Jul 2023
11 Aug 2023
28 Jul 2023
12 Jul 2023 - 22 Jul 2023
Amount
Schedule 'A' Section-I to Section-VIII (BOQ Item No 2.00 to 9.00 here-in-after) (PREPRICED BY MES). These schedules are prepriced by MES and Prepriced rates indicated under column-6. Bidders to quote there rates under Column-7 only .
Schedule 'A' Section-I (Building works)
Schedule 'A' Section-II (Internal Water supply works)
Schedule 'A' Section-III (Internal Electrification works)
Schedule 'A' Section-IV (External Electrification works)
Schedule 'A' Section-V (Path/Hardstanding works)
Schedule 'A' Section-VI (Sewage Disposal works)
Schedule 'A' Section-VII (Area Drainage works)
Schedule 'A' Section-VIII (Air Conditioning & Refrigeration works)
Schedule 'A' Section-IX (Miscellenous item of works) (Item No 10.01 to 10.14 here-in-after) (to be priced by bidders). Bidders to quote there rates under Column-7 only .
M&L 60mm thick prepolished, rubber moulded, double glossy, coloured designer interlocking tiles made of M-35 design mix cement concrete of approved design & shape with crushing strength not less than 400 Kg per sqcm over & including a sand cushioning layer of 25mm thick(consolidated thickness) complete all as specified and directed.
S&F modular metal flush box 8 module complete all as specified and directed by Engineer-in-charge.
S&F sheet metal enclosure for vertical TPN loadline distribution board with provision of mounting MCCB 100 Amp as incomer, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
S&F MCB, SPN, 5 to 40 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
S&F LED light fittings 60watts, input 110 volts to 280 volts, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 65 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 with and including GI pipe bracket 40 mm dia light grade of length 1.5 meter bend to shape and suitable size of clamps nuts bolts , washer , fastner duly painted complete all as specified and directed
S&F industrial socket 32 amp, 5 pin (3P+N+E), 415 volt, 4 pole including 32 Amp MCB TPN, including sheet metal enclosure with fixing in wall complete all as specified and directed.
S&F MCCB 125 amps, four pole 415 volt, 25kA, fixed thermal and magnetic setting complete all as specified and directed.
S&F MCCB 63 amps, four pole 415 volt, 25kA, fixed thermal and magnetic setting complete all as specified and directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and directed.
Supply and laying old size, sub class 'B' bricks, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary T&P for passing of LT/HT cables through 50mm bore GI pipe complete all as specified and directed.
Supply & installation of copper wound voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type desiged for input variation between 170volts to 250volts with output voltage stablized at 230 volts with variation of + 5% and capacity of 5KVA complete all as specified and directed.
Construction of Soakage well 1.2mtr dia & 3.0mtr deep complete all as specified & shown on drawings bearing No. CEJZ/STD-301/90, sheet 1/4 to 4/4.
Construction of Septic tank, 10 users, single compartment complete all as specified & shown on drawings bearing No. CEJZ/STD-263/90, sheet 1/9 to 9/9.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .