Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹71.7 LAccepted-AOC A 332 SECTOR B ROHINI DELHI | DELHI | NORTH DELHI | DELHI | 110085 | 1 | Accepted-AOC lowest bid amt | |
| 2 | Rejected-Technical | - | Rejected-Technical BIDDER DO NOT QUALIFIED IN PQR | |
| 3 | Not Admitted-Fee/PreQual/Technical 232 RAJENDRA NAGAR STREET 7 KAULAGARH ROAD DEHRADUN | - | Not Admitted-Fee/PreQual/Technical Others-vailidity is invailid for e-tender no. 15/EDC(U)/2021-22 | |
| 4 | Not Admitted-Fee/PreQual/Technical 16 A KHADRI MOHALLA SAHARANPUR CHOWK DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Not Admitted-Fee/PreQual/Technical Others-DD FOR TENDER FEES IS NOT MADE IN PROPER ADRESS AGAINST E-TENDER NO.15/EDC(U)/2021-22 |
Tender Value
₹76 L
EMD Value
₹1.5 L
Closing Date
27 Dec 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, EDC (URBAN), DEHRADUN
Office of the Superintending Engineer, EDC (URBAN), DEHRADUN
Construction of New 11 KV feeder emenating from 33/11 S/s Hathibarkala to improve the power supply of the area of Jakhan, Doon Valley, Bhagirathipuram and its adjacent area.
2021_UPCL4_40105_2
TENDER NO 15/EDC(U)/2021-22
Open Tender
Electrical Works
Item Wise
60 days
As Per tender specification
as per tender specification
6 documents required · 6 mandatory
₹5,900
SUPERINTENDING ENGINEER, EDC(URBAN) DEHRADUN
₹1.5 L
Yes
7 Dec 2023
18 Dec 2021
27 Dec 2021
19 Dec 2021
27 Dec 2021
19 Dec 2021
180 days
MATERIAL
11 KV VCB (11 KV VCB outgoing feeder 350/500 MVA 400/200/5 A 110 Volt AC (SCADA OPERATED) (ABB Make complatible with existing system).
Cable jointing kit outdoor type suitable for 3 x400 sq mm XLPE cable
Cable jointing kit indoor type suitable for 3 x400 sq mm XLPE cable
11 KV Cable end termination jointing kit for size 3 x 400 sq mm.
GI Pipe 6'' ISI Mark.
Danger Board and Number plate Complete by providing clamps of MS Flat 50X6 mm and Nuts & Bolts.
Holding clamp for fixing of GI Pipe, Cable, angle and Channels with Nuts & Bolts.
Labour and Erection Charge
Cartage of Steel tubular Pole SP-55 from Araghar Store to Site.
Cartage of Steel tubular Pole SP-23 from Araghar Store to Site.
Cartage of 11 KV 3x400 Sq mm XLPE Cable from Araghar Store to Site.
Cartage of Stock Materials from Araghar Store to Site including Loding and Unloading at both end from (0-20 Km).
Cartage of 11 KV VCB panel From Araghar store to site including loading and unloading.
Laying of 11KV Cable in 1.5Mtr depth with suitable trenchless technology including laying in trench with providing & fixing of HDPE Pipe PE 80 PN 6 & having dia 160 mm conferming to IS 4984/1995 & having thickness 9.1 to 10.3 mm.
Erection ST pole SP-55 double pole structure including excavation of earth pit and fixing all accessories & Grouting of pole 0.45x0.45x1.8 cm [total = 0.365 Cm] with 1:4:8 cc and muffing 0.45x0.45x0.45 cm with 1:3:6 cc respectively. (ST pole SP-55 to be supplied should be as per UPCL Specification).
Erection ST pole SP-23 Single pole structure including excavation of earth pit and fixing all accessories & Grouting of pole 0.45x0.45x1.8 cm [total = 0.365 Cm] with 1:4:8 cc and muffing 0.45x0.45x0.45 cm with 1:3:6 cc respectively. (ST pole SP-55 to be supplied should be as per UPCL Specification).
Erection of stay set 16 x 1800 mm including 7/10SWG stay wire, stay clamps and binding nozzling of stay complete work after excavation of earth & grouting of stay in 1:4:8 cc with dimension 0.6x0.6x0.3 mtr. and filling of rest pit with mud & boulders.
Erection of Earth Rod MS 20x2500 mm by driving it vertically inside the ground for full length at least 0.6 mtr. Below the ground level and jointing it with G.I. strip with nut & bolt or welding , one for LA & DP and painting of earthing strip with green colour. (Earthing Rod and G.I Earthing strip
Fabrication and fixing of MS angle of size 65x65x6 mm after cutting in required size.
Fabrication and fixing of MS channel of size 100x50x6 mm after cutting in required size.
Mounting of 11 KV TPMO/GO switch on Double Pole Structure.
Mounting of 11 KV lightning Arrester on double pole with complete accessories.
Filling and Fixing of Cable jointing kit outdoor type suitable for 3x400 sq. mm. XLPE cable.
Filling and Fixing of Cable jointing kit indoor type suitable for 3x400 sq. mm. XLPE cable.
Filling and Fixing of Cable jointing kit suitable for 3x400 sq. mm. XLPE cable (Striaght Through).
Making of 11KV Cable connection on Pole with fixing of channel and angle.
Fixing of GI Pipe 6" with cable and clamp.
Installation of 11 KV VCB (11 KV VCB outgoing feeder 350/500 MVA 400/200/5 A 110 Volt AC including earthing.
Painting of double pole structure SP-55 (with all accessories) after rubbing, cleaning with sand paper. Two coat of red oxide &1.5 mtr. Top red enemal paint and other portion by one coat aluminum paint.
Painting of Single pole structure SP-23 (with all accessories) after rubbing, cleaning with sand paper. Two coat of red oxide &1.5 mtr. Top red enemal paint and other portion by one coat aluminum paint.
Installation of Danger board and Number Plate.
Civil work [Dismentalling and refixing of tiles on pathway on Rajpur road].
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .