Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC 30 2 RAJKUMAR MUKHERJEE ROAD KOL 700035 | KOLKATA | KOLKATA | WEST BENGAL | 700035 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹3.4 L+₹4,203 (1.24%)Rejected-AOC BAGDAH NORTH 24 PARGANAS | L2 | Rejected-AOC NOT L1 BIDDER | |
| 3 | L3₹4.3 L+₹91,223 (26.9%)Rejected-AOC | L3 | Rejected-AOC NOT L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹6,583
Closing Date
12 Nov 2024, 2:00 pmClosed
Assistant Engineer
Office of the Assistant Engineer Ranaghat Electrical Sub-Division, P.W.D P.O.-Ranaghat, Dist- Nadia
Supply and Laying 50 Sqmm LT Cable With allied E.I Work at Ranaghat Fire Station, Ranaghat, Nadia
2024_WBPWD_766473_1
WBPWD/AE/e-NIT- 03/RH of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Ranaghat Fire Station
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,583
3 Dec 2024
30 Oct 2024
14 Nov 2024
30 Oct 2024
12 Nov 2024
6 Nov 2024
Amount
SUB-HEAD 1-- SUPPLY & LAYING OF CABLES Supply of 1.1 kV Gr. 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cable [Make Gloster/Polycab/ Havells] of following sizes ---- 50 sq. mm [NS] [ From Proposed New Panel to New Barrack Building Panel ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS. [1(a)/F-2 ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. [3 (b)/F-2 ]
Laying of following sizes 4 core Armoured/Aluminum conductor cable on wall/surface including S & F MS clamps with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 50 Sq. mm [ F 1 / 2 (b)]
Laying of following sizes 4 core Armoured/Aluminum conductor cable as below after cutting floor/pavement/wall and making holes incl. embedding the cables at an average depth as below and nending good the damages to original finish incl. removing the rubbish 50 sq. mm at an average depth of 75 mm in floor/pavement/wall etc. [ F 3 / 5 (i)]
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland as per GS 4 Core 50 sq. mm [ 7 C / F 4 ]
Finishing of the XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket ( DOWELS ) make , tapes , anticorrosive paste & jointing materials as per GS. 4 Core 50 sq. mm [ 7 C / F 4 ]
Supplying & fixing medium gauge GI pipe (ISI - Medium) protection with necessary fittings and jointing materials as required . 80 mm dia [F 6 / 11 (F) ]
Widrawing 3.5 /4 Core 16 Sq.mm LT cable from existing trench and laying the same in under ground trench 460mm wide x 760mm average depth with brick protection on the top of the cable with 8 (Eight) nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil,leveling up and restoring surface duly rammed . asper GS . [NS] (For existing 3.5 /4 Core 50 Sq.mm LT cable sq.mm Lt Cable near Main Panel)
SUB-HEAD 2 -- Fitiing & Fixtures Supply of Led street light (230 V 35Watt to 45 Watt 5500 K ,IP 66 ,THD <10% ,Built in 2.54 SPD )LED Light Fittings. ( Make - Philips , / Wipro / Havells /Cromptons /panasonic /Bajaj )
.Supply of 240V, 70 / 72 W LED Street light make Philips Cat no. BRP502 LED126 CW R3C PSU S1 / Wipro LR26-112-XXX-65-XX / Equivalent model of Havells ( For existig Steel Tubular Pole )
Supplying & drawing of 1.1 KV. Gr. 3 core 1.5 sq. mm PVC insulated Cu. wire (Make - Finolex/Havells/Polycab) through 20 mm dia 3mm thick(uniformly) soft drawn polythene pipe from Pole Loop Box to LED fittings (NS)
Cutting Channel of 40 mm x 40 mm size on masonry wall by Electric operated cutting machine incl. supplying & fixing 19 mm dia 3 mm thick heavy gauge polythene pipe by means of anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackles. [6(b)/ E-3]
Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [9/F-5] 3 x 22 / 0.3 (1.5 sq. mm) /2.5 Sq.mm
Fixing only outdoor / Street Light type fluorescent light fittings or LED light fittings complete with all other accessories to be fixed / projected from the wall of the building incl. making holes / providing 2 nos. MS clamping arrangement made with 40 mm x 6 mm MS flat & fixing 9 mm x 10 -150 mm nut bolts in wall after making hole in wall and mending good damages to finish also S & F 40 mm dia GI Pipe ISI make medium / required size dia GI pipe 1.50 mtr. average length having suitable bend / as per instruction of EIC incl. S & F necessary length of 3 x 1.5 sq.mm copper wire and making necessary connections as required and shoul;d be earthed properly and painting . (19 /C 3)
S & F of 2 mm thick, stainless steel sheet fabricated, water proof type looping cable box (200 mm x 150 mm x 100 mm deep) comprising of one 240 V, 16 A kit-kat fuse unit, 4 nos. 16 A stud type connectors, lined with rubber gasketed hinged top cover with mechanical locking arrangement etc., earthing terminal with lug on pole above the muffing with S&F 2 nos. flat iron clamp set made with 30 mm x 4 mm thick flat iron bar with nut-bolt etc. suitable for fixing above mentioned loop box on the pole including painting with anticorrosive paint. NS
Sub Head 3 :-Earthing Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI Medium GI pipe as to GS (2 a / G1 ).
S&F earth bus bar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as to GS ( 4 a / G - 2)
Supplying and fixing 415 V, 32 A per way double door HTPN MCB DB (Make - Siemens/ Legrand/Havells) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ---- [14 / D- 10 ] 4 Way
Supplying and fixing 240 V, double-door SPN MCB Distribution Board ( (Make - Siemens/ Legrand/Havells ) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. ---- [13 / D- 10 ] 2+10 Way
Supplying and fixing of following rating 240/415 V 2/4 MCB type pole Isolator ( (Make - Siemens/ Legrand/Havells) on din rail of existing DBs and necessary connection. 6 / D-5. 415 V ,63 A FP
Supplying and fixing 240 V, 6/10/16/20/25/32 A SP MCB of Breaking capacity 10 kA & C characteristics ( (Make - Siemens/ Legrand/Havells) on din rail of HTPN and SPN DBs and necessary connection. 7 / D-6.
Sub Head 4 :SITC of AC Supply of 1.5 Tr. Split type Air - Conditioner Machine having following features - Cooling Capacity - 5300 Watts, Compressor - Rotary, EER -3.57 W/W, Star Rating - 3, Power Requirements 220/240 V 50 Hz, Remote Control - Yes, Main Unit Condenser Coil - Copper, Outdoor Unit Condenser Coil - Copper, Refrigerent - R410A / R32, Modes - Cool Mode - Yes, Sleep Mode - Yes, Timer - Yes, On-Timer: Yes, Off-Timer: Yes. (Make:Make: O-General, Model No. - ASGA18BMWA-B / Mistubishi Heavy Endustries / Mistubishi Electric
Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages.(NS)
Supply & laying of following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non adhesive tape. (NS) 6.35 mm (1/4") dia
15.88 mm (5/8") dia
Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated Copper wire for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel) (NS)
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated Copper wire for connecting the ODU TO IDU. (Make - Havells / Finolex / RR Kabel) (NS)
Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction.(NS)
MALLICK ENTERPRISE (BID ID -5744189)
GEM ENGINEERS CO-OP SOCIETY LTD (BID ID -5744587)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .