Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance KALIKA GUNJ COLONY SIRSIA GIRIDIH JHARKHAND | GIRIDIH | JHARKHAND | 815301 | Admitted-Finance |
| 2 | Admitted-Finance 614 HARIOM TOWER COMMERCIAL COMPLEX CIRCULAR ROAD LALPUR RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
| 5 | Rejected-Technical B 104 MANISHA TOWER PLOT 7B SECTOR 23 DWARKA NEW DELHI 110 077 | Rejected-Technical NON RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹97.0 L
Closing Date
13 Jun 2023, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya Dhurwa, Ranchi-834004.
Construction of New Class Room Block and Multipurpose Hall cum Examination Centre, Research and Development Centre and other works in B.I.T. Sindri, Dhanbad
2023_JSBCC_71194_1
JSBCCL/44/2023-24
Open Tender
Civil Works - Buildings
730 days
Dhanbad
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹97.0 L
JSBCCL
6 Jul 2023
17 May 2023
15 Jun 2023
17 May 2023
13 Jun 2023
17 May 2023
24 May 2023
Amount
Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, leveiling,ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Extra for earthwork in hard soil as per specification and direction of E/I (Vide classification of soil item_B).
Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) : 6 graded stone aggregate 20 mm nominal size.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand ) : 8 graded stone aggregate 40 mm nominal size )
Providiing & Laying damp Proof coarse 50mm thick with cement concrete 1:2:4(1 Cement : 2 coarse sand (zone-Ill) : 4 graded stone agrregarte 20mm nominal size
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Roof slab
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works upto plinth level
All work above plinth level upto floor V level
Extra for providing richer mixes at all floor level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
lintels, beams, plinth beams. girders. bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases
Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Edges of slabs and breaks in floors and walls. Under 20 cm wide
Suspended floors, roofs, landings, balconies and access platform. With 12mm waterproof ply
Lintel beam, plinth beam With 12mm waterproof ply
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. includIng cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (Plan area to be measured).
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm,28mm,32mm dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.(TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12mm,16mm,20mm,25mm dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing average 150 mm thick dry rammed koha beaten to 112 mm. (Compacted with water ) made of well burnt or jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blending the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
Providing designation 100 A brick work with fly ash lime brick (FLAG)confirming to IS 12894-1990 (9"x4.5"x3") in C.M. ( 1 : 6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, rakingout joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/1.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood prese?rvative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l.
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality 1.0 mm thick.
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete : 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with ineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing of fire rated heavy duty door closer tested in accordance with BS:476 Part 22 for fire rating) and BS EN 1154 with minimum one year warranty.
Providing and fixing fire rated mortice lock with lever handle tested in accordance with European Standard EN12209 / DIN18251 and 80mm Long cylinder to EN1303 of approved brand and manufacturer having min. 1 year manufacturers warranty.
Providing and fixing 300 mm long stainless steel grade 304 D type back to back pull handle of approved make with necessary bolts with alen key arrangement etc complete.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per drawing and direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing In position and applying a priming coat of approved steel primer all complete,
Supplying, fitting and fixing M.S. grill made of 20x6ermm M.S. flat / square bar as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I.
Supply, fabrication and Installation and fixing of SPACE FRAME structure The modular MS Frame shall be consisting of tube 72 mm and 72mm /3 mm CHS and 85 mm /3mm CHS and painted with Duco spray coat over priming coat
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and laying 25mm thick. Kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime mortar (1:1:1) (lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royality all complete as per building specification and direction of E/I. (iv) 600 x 600 mm size
Providing and laying 25mm. thick kotah stone tiles in risers of steps, skirting and pillars of approves size, texture and colour laid over 12mm. thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing te granolilthic finish with approved quality of carborandum stone including cost of curing, taxes and royality all complete as per building specification and direction of E/I. (iv) 600 x 600 mm size
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Double charge vitrified tile polished finish of size
Size of Tile 600 x 600 mm
Size of Tile 800 x 800 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels
Granite of any colour and shade
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-Charge Granite work.
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
hequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge
Cast-in-Situ Cement Concrete M20 Kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Cast-in-Situ Cement Concrete M20 Kerb
Making bajri path including preparation of subgrade, supplying and laying brick aggregate of 50 mm nominal size 7.5 cm deep with blinding material consisting of 12 mm moorum and 12 mm red bajri consolidated with road roller.
Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring 'T' with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).
Roof Joint of 100 mm gap
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :
v) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
vi) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
vii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area.
viii) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Water proofing for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-
(a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.
The Watqrproofing Brand:*Sil<a Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Equivalent
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of incharge
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
Providing of two coats of plastic emulsion paint of approved shade and make over a coatof cement primer over a new surface including preparation of plasterd surface by rubbing smooth with pumice stone or fine sand paper apply putty wherever required and scafold do
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
Providing & fixing Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
Providing and laying light weight/foamed cement concrete having density between 800 Kg/cum to 1200 Kg/cum, compressive strenght between 4 - 6 Mpa of Nuvoco (XLITE) make or equivalent
Providing and fixing of Glass Fiber Reinforced Concrete (GFRC) Column in approved size, pattern, Design, thickness and color. The Column should be made From 53 grade white Portland cement/ 43 grade OPC or PPC gray cement manufactured by J.K. Cement or equivalent having minimum compressive Strength of 40N/mSQM, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by Sant Gobain, Owens corning or equivalent, super plasticizers and polymers manufactured by BASF, Sika, MYK Schomburg or equivalent. The material casting should take place in Synthetic Rubber / FRP Mould manufactured by Reckli or equivalent. The Fixing of Column should be Dry Fixing i.e. to be done with Stainless Steel (SS-304)/ MS Frames, dash fasteners, Self-screw and pins. GFRC Column (35-40 mm thick) as per design with GFRC capitals. Note :- MS frame Structure for GFRC column to be provided as per design
Providing and fixing in position about 50mm thick border and 35mm thick design Jali at all levels made from Glass fibre reinforced concrete (GRC) using white cement, Quartz Sand, AR Fibres, Water Plasticizers & pigments in approved shape, size and length as per the design and drawings and as per specifications, mix design and test results given below. The typical Screen should be of sizes as per the drawings. Fixing of GRC Jali shall be with help of S.S. Screws Fixtures, M.S Angle Cleats, Fissure Plug, and Dowel Pin proper alignment as per drawings (Shop drawings to be Submitted by the contractor before the work start). As per approved paint, shade & Finishing with GRC powder & filling the joints with Epoxy sealant neatly between GRC screen and primary structures. The Screen should be in absolute straight plumb line and length and joins between channels should be neatly filed to make seamless uniform surface across the entire elevation of the building without any visibility to joints. Any framework to be paid extra as per item.(GRC Screen)
Supply, Installation & testing, Commissioning and Handover Machine Room Less Lift with a speed 1.5 m/s Serving All Floor as per Drawings. Complete SS Finish and as per CPWD Specs. 16 Passenger Lift.
Providing Flexstone Brick tiles , Made In India, for cladding along the walls, made with recycled raw materials and cement used as a binder, with Density more than 1800kg/m3, high compressive strength around 50 Mpa and abrasion resistant, exterior grade applied with polymer based adhesive with good adhesion strength and fast curing. Product to be green and sustainable, LEED certified, weather & algae fungus resistant, breathable, insulated, no VOC, fire rated and have high melting point and almost no discoloration. Stone weighing approx 4 to 5 Kgs/sqft to be applied with the polymer modified adhesive applied as a uniform scratch coat first and individual pieces over it. The protective transparent water based breathable PU sealer coat to be done overall with the help of a brush in the final stage for a maintenance free cladding altogether. Products to be maintenance free and the company to provide 12 years of warranty against manufacturing defect. Fixing and cutting of the stones to be done as per the drawings, specifications and instructions of the Architect or Engineer incharge.
Supply & Installation of 22mm thick multicell and multi-layered flux standing seam UV protected polycarbonate panel system along with standard fixing accessories as per direction of the engineer in charge. Panel shall be of min 22mm thickness in multicell truss bridge structure for more flexibility and better load bearing capacity. The entire panel shall be coextruded UV protected and block 99% UV rays. Panels shall have minimum six - seven layers. Panels with more layers will be preferred to control deflection due to snow load. Panels shall be a combination of translucent and opaque louvers integrated in clear body for angular day lighting and best diffused daylight in single long length to avoid any transverse joint in approved colours as per required lux level and design requirements. Panels shall be with all standard fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam and shall be fixed on Purlin (will be paid separately) with double tooth locking mechanism with SS HD Trapezoidal Fastener and big snap on connectors with a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. The Panels width shall be of 1000-1200mm (min) and panels with more width will be preferred to minimize panel junctions. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.7 W/m2K as per EN ISO 10077-2:2018. Flux panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: White louvers with clear body or as Approved Approved Make: Flux/ DPI Daylighting /Rodec/DANPAL0N or approved equivalent.
Providing and fixing SILENZO+ dB Wood Perforated panels of width 190mm, thickness of 12mm and length of 1180mm , made of a medium density fibre board substrate with laminated/Melamine facing as per the approved shade / species and finish and a melamine balancing layer over the reverse side. .The board shall have a special perforated pattern of 6 mm diameter of hole thru out the area with a toung and groove to fix on the wall without screw. Installed with rockwoll of 50mm thick a perimeter of 0.5mm thick have a unequal flange of 26 mm and 18 mm to be fixed on floor and soffit with the help of water level marking, than a GI section of (Hat channel) shall be placed at c/c 600 to make a grid. than specially extruded aluminum sections of 18 mm x25 mm shall be fixed to hat channel perpendicular using Metal screws spacing at 600mm c/c. Place the dB Wood clip to install the first set of wooden panels by inserting the clips for border and insert the panel into projecting flange of clip. Continue installing rows of panels by inserting the tongue into the groove of earlier inserted panel and progressively installing clips for inside into the next keel till the actual height is achieved. Use clips for the border to finish off the installation. Edges should be finished using wooden moulding of matching colour. A slab of rockwool 48 kg density and 50mm thick shall be placed under the groowood olmac panel.The system shall give NRC of 0.77 with as per ASTM C 423, The color and design shall be approved by architech & Engineer In-charge.
Design, Fabricate, deliver (to job site) and install mechanical toggle based aluminium glazed system. The system to be pressure equalised, ventilated and drained. The mullion and transom should be made of Aluminium Alloy 6063 T6 with a face width of 50mm. The mullion should not deflect more than L/175 or 19mm (L/240 + 6.35mm: To be used if mullion span is larger than 4.11m) whichever is the least, based on the wind load as specified under IS Code 875 Part 3. The transom should not deflect more than 3mm due to dead load and 15mm due to wind load as specified under IS 875 Part 3. The transom should overlap the mullion with an EPDM separator. The screws for transom should not affect the transom gaskets. The system should have a continuous base transom with suitable continuous EPDM base gasket. The system should accommodate glass and infills as per architectural intent. The glass / infill should be mechanically restrained to the mullion and transom using fixing cleats at not more than 400mm c/c. All gaskets to be EPDM except those which come in contact with structural silicone. All gaskets in contact with structural silicone should be made of Silicone as well. Glass to Glass joint to be 20mm and sealed with non-bleeding sealant or silicone gasket. The system should have already been tested/accredited by an international independent testing laboratory. The system should comply with an Air infiltration requirement of ±600 Pa when tested in accordance with ASTM E283, Static water penetration of 720 Pa in accordance with ASTM E331. The system should be capable of passing a repeat air infiltration of ±600 Pa and static water of 720 Pa after design load of ±1.8 kPa. The system should also comply with a proof load of ±2.7kPa. All exposed profiles should be powder coated to a minimum of 60 microns. All anchor fasteners to be made of SS 304 grade. All shims to be capable of transferring the load evenly and made of a suitable material (GI, Teflon etc) capable of lasting the life span of the system. All miscellaneous items such as peripheral sealants, backer rods, flashing, fasteners, brackets etc to be included in the rate. Spandrel Areas: The system should be capable of accommodating glass / infills. The spandrel adapter should be fixed using cleats at not more than 400mm c/c. The spandrel cavity to be ventilated and drained. The spandrel cavity must be sealed all around in front of the backpan. Backpan made up of 1mm Galvanised sheet + 50mm insulation of density 48 kg/m3 + 2mm Galvanised sheet (room side). Provide for supply and install of suitable smoke stop at every floor consisting of 2mm Glavanised sheet, 60 kg/m3 high density fire-rated insulation, 120mm deep between the backpan and the floor slab face. Where the mullion joint allow for live load deflection, backpan must also accommodate the same. All miscellaneous items such as peripheral sealants, backer rods, flashing, fasteners, brackets etc to be included in the rate.
Design, Fabricate, deliver (to job site) and install fixed window from specified brands. The system should be pressure equalized, ventilated and drained. The outer frame should be made of Aluminium Alloy 6063 T6 with a depth of 40mm. The vertical member should not deflect more than L/175 or 19mm whichever is the least for a wind load of 2.00 KPa. The horizontal member should not deflect more than 3mm due to dead load and 15mm due to wind load of 2.00 KPa. The system should accommodate upto 24mm DGU (6mm Toughened glass + 12mm Air Space + 6mm Heat strengthened glass) in vision areas (refer glazing specification mentioned as a separate BOQ item). All gaskets to be EPDM. The system should have already been tested/accredited by an international independent testing laboratory. The system should comply with an Air infiltration requirement of ±600 Pa when tested in accordance with EN 1026, Static water penetration of 600 Pa in accordance with EN 1027. The system should be capable of passing a repeat air infiltration of ±600 Pa, Static water of 600 Pa after design load of ±2.00 KPa. The system should also comply with a proof load of ±3.00 KPa. All exposed profiles should be powder coated to a minimum of 60 microns. All anchor fasteners to be made of SS 304 grade. All shims to be capable of transferring the load evenly and made of a suitable material (GI, Teflon etc) capable of lasting the life span of the system. All miscellaneous items such as peripheral sealants, backer rods, flashing, fasteners, brackets etc to be included in the rate. Glass cost will be separate.Schueco, Kawneer, Panoramah
Design, Fabricate, deliver (to job site) and install casement window from specified brands. The system to be pressure equalised, ventilated and drained. The outer frame and vent frame should be made of Aluminium Alloy 6063 T6 with a depth of 40mm. The vertical member should not deflect more than L/175 or 19mm whichever is the least for a wind load of 2.00 KPa. The horizontal member should not deflect more than 3mm due to dead load and 15mm due to wind load of 2.00 KPa. The system should accommodate 24mm DGU (6mm Toughened glass + 12mm Air Space + 6mm Heat strengthened glass) in vision areas (refer glazing specification mentioned as a separate BOQ item). All gaskets to be EPDM. Locking point and mechanism should be as per System provider's document. The system should have already been tested/accredited by an international independent testing laboratory. The system should comply with an Air infiltration requirement of ±600 Pa when tested in accordance with EN 1026, Static water penetration of 600 Pa in accordance with EN 1027. The system should be capable of passing a repeat air infiltration of ±600 Pa, Static water of 600 Pa after design load of 2.00 KPa. The system should also comply with a proof load of 3.00KPa. All exposed profiles should be powder coated to a minimum of 60 microns. All anchor fasteners to be made of SS 304 grade. All shims to be capable of transferring the load evenly and made of a suitable material (GI, Teflon etc) capable of lasting the life span of the system. All miscellaneous items such as peripheral sealants, backer rods, flashing, fasteners, brackets etc to be included in the rate. Glass cost will be separate.Schueco, Kawneer, Panoramah
Providing and Fixing backdrop panneling of size as per drawing , made in hard wood frame(mirandi wood) 50mm x 50mm thick & c/c 600mm maximun both ways joint rigidly horizontally & vertically with nails, screws etc. fixed to wall/ceiling & columns with wooden plugs. 11 mm thick MDF Board is to be fixed on top of frame with 10x8 mm deep grooves on both sides of the center panel. 11mm MDF Board is to finished with laminate on both side of approved design and all groves to be finished with lacquer polish matching with laminate shade. Center panel is of 19mm MDF jali of aprooved design and of size: The visible part through MDF Jali is to be finished with lacqured glass of approved design. All work is to be carried out as per drawing and instructions of engineer in charge. ( MDF Board/ MDF Jali & Laminate Make Green ply/Century /Merino or Equivalent ), (Adhesive make Pidilite or equivalent)
Providing and fixing Vision -24mm thick DGU ( 6+12A+6) of either SKN 765 or DS Blue 40 or Solar Plus Blue 27, all complete as per drawing and direction of Engineer-in-charge . Saint Gobain / Guardian /AIS /Sisecam
Providing & Fixing Terracota Jali all complete as per drawing and direction of Engineer-in-charge .
SAND ( 10KM )
CHIPS ( 22 KM )
METAL ( 22KM )
BRICKS ( 8KM )
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.
Excavation in soil using Hydraulic excavator CK 90 and Tipper with disposal upto 1000 meters. Excavation for road work in soil with hydraulic exacavator of0.9 cum bukett capacity including cutting and loading in tipper, trimming botttum and side slopes, in accordance with requirement of lines, grades and cross section, and transporting to the embankment loacatoin within all lifts and lead upto 1000m)
Scarifying existing bituminous surface to a defth of 50 mm by mechanical means (Scarifying the existing bitumious road surface to a defth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres.)
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.Rate per cum for grading-II Material-Plant Mix Method
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density
Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor @0.20 kg/sqm on the prepared bituminous surface cleaned with mechanical broom. As per MOSRT&H specification 502 (5th revision ) & as per direction of E/I.
Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7to achieve the desired compaction.
Dense Graded Bituminous Macadam Grading-I with Modified Graded Bulk Bitumen,Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects with Modified Graded Bulk Bitumen.
Providing and fixing of Retro-reflectorised cautionary, mandatory and informatorysign as per IRC:67 made of high intensity grade sheeting vide clause 801.3 ,fixed over aluminium sheeting ,1.5 mm thick supported on a mild steel iron angle post 75mmx75mm x6mm firmly fixed to the ground by means of properly designed foundation with M15 gradecement concrete 45cmx45cmx60cm ,60 cm below ground levelas per approved drawing
(i)90cm Equilateral triangle
(ii)60cmx60cm Square
(iii)80cmx60cm rectangular
(iv) 60cm.x45.0cm rectangular
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8- 1980, fixing in position including painting and printing etc)
Deep Boring
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 5 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
PLUMBING WORK
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 40mm Dia
Providing and fixing PTMT Bottle Trap for Wash basin. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing & Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same material with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and Fixing in position Hindware make or equivalent CP Grab Bar with wall flanges 600 mm to wooden cleats with C.P. brass screws complete in all respects.
Providing, Fixing, testing and commissioning of C.P. brass wall/counter mounted Single Lever sink mixer with C.P. wall flange, overhead swinging spout/goose neck complete as required and making good Including necessary wall cutting / chasing and making good, as required of make parryware diamond range or equivalent as per direction of Engineer in Charge. HINDWARE make - ELEMENT (Cat No. F360027) / Equivalent
Supply and fixing HINDWARE make or equivalent Health Faucet with 8 mm dia, flexible tube with wall hook and Angle stop cock with wall flange . Etc all as directed by Engineer In-Charge.HINDWARE make Health Fauce - 1.25 Mtr. long (Cat No. F160013)/ Equivalent
Providing and Fixing in position best HINDWARE make Vitreous Chinaware partition slab for urinals, size 690X165X325mm, all as specified and directed. (Cat. No. 61001 of HINDWARE make) / Equivalent
Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. ( Make - Parry Ware Product Code- C500339) Capacity 25 litres.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
INTERNAL DRAINAGE (SOIL, WASTE,VENT & RAIN WATER DISPOSAL PIPES FITTINGS):
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.
90 mm (OD) SWR Pipe
110 mm (OD) SWR Pipe
Providing, Fixing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around UPVC waste pipes under floor, including shuttering and necessary reinforcement etc. complete as required for: -
90 mm dia
100 mm dia
Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors 110 mm (OD) x 110 mm (OD)
Providing, Fixing, testing and commissioning of UPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work. 110 mm OD
Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection)
Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD
Providing, Fixing, testing and commissioning of UPVC inlet fittings with maximum 3 inlets 40, 50 & 63 mm OD size UPVC sockets, fixed to CI/UPVC traps including solvent weld joint/rubber ring joint complete with all civil work.
Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia with 25 mm waste hole
Providing and fixing straight/offset type flexible single body push fit type WC Pan Connector with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet).
Providing and fixing in position stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.00 mm thick top grating (Jali) with ring to be fixed inside C.I. or uPVC ‘P’ traps with cement concrete.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion and with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.
Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm thick in bed and all around UPVC pipes under floor, including shuttering and centering for: -
160 mm dia
110 mm dia
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
DOMESTIC / FLUSHING/ HOT WATER SUPPLY :
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal OD
20 mm nominal OD
25 mm nominal OD
32 mm nominal OD
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - (Exposed on wall Terrace)
15 mm nominal OD
20 mm nominal OD
25 mm nominal OD
32 mm nominal OD
40 mm nominal OD
50 mm nominal OD
65 mm nominal OD
80mm nominal OD
Thermal Insulation on CPVC Pipe Embedded in Wall
Providing & fixing thermal insulation on hot water pipes a flexible electomeric foam of closed cells structure having thermal conductivity of 0.038 W/M.K at 40o C, water vapour permeability fire propagation including all accessories e.g. adhesive and ape on joint complete as per specification. All joints shall be sealed with adhesive & cotton tape.
15.9 mm (OD) [6mm thick insulation]
22.2 mm (OD) [6mm thick insulation]
28.6 mm (OD) [6mm thick insulation]
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
Providing and fixing forged brass auto air vent valve PN10 (10.00 Kg/cm2) rating including all fitting with ball valve & accessories. 15 mm dia
Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).
50 mm dia
65 mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm dia
20 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm dia Horizontal
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 80 mm dia
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100 mm dia.
150 mm dia.
200 mm dia.
250 mm dia.
Providing and laying 150 mm thick cement concrete 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.
100 mm dia S.W. pipe
150 mm dia S.W. pipe
200 mm dia. S.W. pipe
250 mm dia. S.W. pipe
Constructing water tight brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement :4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size). Foundation concrete 150 mm thick 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside and outside plastering 12 mm thick with cement plaster 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels and benching in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design,complete with SFRC cover Heavy duty of adequate size as per standard design and approved drawings . (Price shall include the, cost of excavation, back filling, disposal of surplus earth, dewatering & water proofing of manholes as directed at site & other associated civil works).
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
150 x 100mm size 'P' type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing water tight brick masonry grease trap with first class bricks in cement mortar 1:6 (1 cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size, foundation concrete 150 mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement & M.S. foot rests including fixing in 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size), two brick masonry baffle walls each of 500 mm depth deep each of 115 mm thickness, 2 Nos C.I. double seal medium duty covers each of 450 x 450 mm size including excavation, backfilling & disposal of surplus earth with a lead upto 50m complete as per standard design.
(Note: Cost shall include dewatering & water proofing of Grease trap as directed at site).
Grease Trap (Size 1200 x 900 x 1000 mm overall depth).
Providing & laying S & S cast spun pipes conforming to IS : 1536 class 'LA' including all fittings conforming to IS : 1538 e.g. bends, tees, reducers, blank flanges, tyton joints as per IS : 3114, effective proper connection (For External Sewer Line + Bypass line from Equalization tank to municipal sewer) complete i/c excavation/back filling, bed concrete, sand bed, painting two or more coats with synthetic enamel paint over a coat of primer. 100 mm dia
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
250 mm dia
300 mm dia
450 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
250 mm dia.
300 mm dia.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Constructing brick masonry road gully chamber 50 x 45 x 60 cm unit brick of class designated 75 in cement mortar 1:4 (1 cement :4 coarse sand) including 500 x 450 mm precast RCC horizontal grating with frame complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside rought cement planter 15 mm thick with CM 1:3 (1 cement:3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.
0.91 m deep with S.F.R.C. cover and frame (heavy duty HD-20 grade designation) 560mm dia at top conforming to IS 12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) including excavation in all kinds of soil refilling centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately).
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
PUDDLE FLANGE FOR WATER TANKS
Providing and fixing M.S fabricated epoxy coated(two layers) galvinised coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size upto 150 mm dia & 7.1 mm thick mm plate for pipe dia above 150 mm dia including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground/ overhead tanks.)
25 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing and placing on terrace storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
Providing and fixing G.I. Vent Pipe class 'B' (medium duty) for R.C.C water storage tanks comprising of 600 mm long vertical pipe, return bend with mosquito grating & cast brass perforated coupling including all associated civil work.
80 mm dia
100 mm dia
Providing and fixing of mosquito overflow grating /Jali of the following diameters including all fitings & accessories :- 100 mm dia
Water Supply, Drainage Pumps & Water Treatment Equipments
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Filter Feed Pump (Dom. Water) at Water Supply Pump Room
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 2.0 LPS
Head 25 M.
HP 2.0 HP Approxi.
Raw Water Transfer Pump to STP at Pump Room
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 1.0 LPS
Head 25 M.
HP 1.0 HP Approxi.
Irrigation Pump at STP Pump Room
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 4.0 LPS
Head 40 M.
HP 5.0 HP Approxi.
Providing, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 100 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects,
including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Domestic Water Supply at Water Supply Pump Room
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 2.5 LPS
Head 30 M.
HP 2 HP Approxi.
Hyd. System for Flushing Water Supply at STP Pump Rm
Set of Two Pumps ( 1 Working+ 1 Standby)
Capacity 1.5 LPS
Head 30 M.
HP 2 HP Approxi.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge.
(Pumps shall be installed in a set of two pumps One working and One standby)
Pump Room Drainage Pumps
(Pumps to be suitable to handle solids upto 30 mm size)
Capacity - 4.0 LPS (Each)
Head - 15 M
H.P. - 1.5 HP Approx.
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
Dual Media Filter For Domestic Water Supply
Capacity- 7200 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Activated Carbon Filter For Domestic Water Supply
Capacity- 7200 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects. Chlorination of Domestic Water
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top or bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
Electric Panel For Water Supply Pumps at Water Supply Pump Room
INCOMING
1 No. 150 amps TPN MCCB with the following accessories:
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.
Three phase indicating lights.
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 200 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.
OUTGOING UNITS
Four 25 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
01 Nos. TPN MCCB of 63 A with 25 KA service breaking capacity for domestic water hydropneumatic pumps. (Only connection to inbuilt panel of Domestic water hydropneumatic system)
4 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 5 HP pump .
4 Nos.cyclic relay for automatic duty changeover of pumps.
4 No. single phase preventors.
Space for 3 Nos. Level Controllers.
Switchgear shall be suitable for the HPS of various motors.
2 Nos. 32 Amp. TPN MCB Spare.
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.
Motor control centre as described above
For Drainage Sump Pump
One incoming main MCCB unit of 63 amps rating.
Copper bus bar is separate chamber fully taped of 100 amps capacity.
Two MCB units of 25 amps
Two fully automatic DOL starters with push buttons and on/off indicating lights.
Two manual/auto/off switches.
Two single phasing presenters.
Two ampere meters one for each motor.
Three neon phase indicating lights on the incoming mains.
Space for one liquid level controllers.
All internal wiring colour coded from incoming mains to various switchgear, starters, meters, indicating lamps and bus bar with a changeover facility to run each pump alternatively with an alarm bell in case of both pump’s running at one time. Switchegear offered must be compatible with the HP of the motors offered.
Motor control centre as described above
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required.
For Water Supply Pump:
To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
For Sump Pumps:
To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 25 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 25 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required.
50 mm dia
65 mm dia
80 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm.
50 mm dia
65 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.
Power cable Copper 3 core 10 sq.mm
Power cable Copper 3 core 6 sq.mm
Power cable Copper 3 core 4 sq.mm
Control cable copper 2 core 1.5 sq.mm
Providing and fixing CI Y type suction strainer with gunmetal or brass internal parts installed outside water tanks. 100 mm dia.
Sewage Treatment Plant
Designing, Supply, installation, Testing and commissioning of complete mechanical and electrical Items with stand by pumps as mentioned in the List of Mechanical equipment’s of the STP-200 KLD based on MBBR technology. (Excluding civil works)
List of Electro-Mechanical Equipments
Bar Screen-2nos
Level Switch-1Set
Sewage lifting pump-2nos
Plant Room Sump Pump-2nos
Air Blower-2nos
Air dispersion system
Fine bubble diffuser-1Lot
corse bubble diffuser-1Lot
Air piping-1Lot
Sludge recirculation pump-2nos
Filter press (Manual)-1 Nos
Screw pump-2nos
MBBR media-1Lot
Tube settler media-1Lot
Filter feed pump-2nos
Multigrade Filter-1 Nos
Activated carbon filter-1 Nos
Pressure guage-1Lot
Dosing pump-1 Nos
Piping & Fitting-1Lot
Electrical control panel-1 Nos
Electro Magnetic Flow Meter-1 Nos
Cable & Cable tray-1 Nos
Ulta violet (UV) System -1 Nos
MBBR 1 & 2 Tank (MSFRP)-2nos
Tube Settler Tank (MSFRP)-1 Nos
Filter Feed Tank (MSFRP)-1 Nos
Treated Water Storage Tank (MSFRP)-1 Nos
Screen cum Oil & grease chamber-1 Nos
Oil & Grease chamber-1 Nos
Collection Tank-1 Nos
Plant Room-1 Nos
Foundation for equipment-1 Nos
COMPLETE JOB 200KLD STP
Fire Fighting work
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
450 lpm at 35 m Head
PIPES & ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.2 way-100 mm dia M.S. Pipe. (FOR FHC )
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m )
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. 100 mm
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas) Capacity 4.5 Kg.
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) Capacity 6.0 Kg.
HVAC WORK
AIR CONDITIONING EQUIPMENTS HIGH SIDE
Supplying, installing, testing and commissioning of Air Cooled Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expension kit to connect with DX AHU, and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonary Pedastal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulfur and other chemical contaminants present in the air. The coating should be done in the presence of OEM represantative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
Supply, Installation, testing and commissioning of self diagnostic type Corded remote controllers for operation of indoor units.
8.5 TR (3400 CFM) Ductable Split Unit
11.0 TR (4400 CFM) Ductable Split Unit
17.0 TR (6800 CFM) Ductable Split Unit
AIR COOLED DX TYPE SPLIT AC UNITS
Supply , installation, testing & Commissioning of ceiling suspended DX type split AC units with air cooled condenser complete with 5 Star Inverter type scroll/rotary compressor ,condenser ,wiring & accessories . Indoor units shall be ceiling suspended/wall mounted type complete with evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , corded remote controls. The unit shall be suitable for working at 240 ± 10% ,50 Hz,1 phase AC supply .The unit shall be designed to take care of minimum vertical head 5mt & horizontal length of 30 mt & necessary oil separator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make, shade by Architect) with necessary vibration isolation arrangement as per site condition etc. (without condensate drain pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid separately ).
The coil in the outdoor units shall be provided with anti corrosive treatment. Necessary corrosive treatment of copper coil of the ODU with Blygold PoluAl (Aluminum hydroxide, 25-microns thickness) to protect from corrosion, sulfur and other chemical contaminants present in the air. Coating should be done in presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
The Outdoor unit Compressor must be provided with 5 Year Warranty Period.
Silver Ion Filter, Dust Filter
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.
Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts
Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning.
Incoming power supply shall be provided near each indoor units
2.0 TR (650 CFM)
Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.
TRANSMISSION & CONTROL WIRING
Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units.
2C x 1.5 Sq mm (Shielded-Unarmored)
REFRIGERANT PIPING
Supply, fixing, testing and commissioning of interconnecting soft/hard drawn copper refrigerant pipe work of following outer diameter duly insulated with fire rated class'O' closed cell elastomeric nitrile rubber type tubular insulation (19mm/13mm thick) between indoor & outdoor units & protected with 28 G aluminium sheet cladding as per specifications. All piping should be laid on Galvanized/Powder Coated tray supported by Galvanized M S Hangers & Clamps and all external piping shall run in covered cable trays. The rate includes all the items required to complete the piping work and nothing extra should be payable except the cable tray.
Vaccumiazation & Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU.
Civil Work such as wall hole making , wall chiseling ,refilling of chiseling part with mortar etc. as per site condition.
6.4 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
9.5 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
12.7 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
15.9 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
28.6 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
DRAIN PIPING
Providing and fixing of cPVC drain water piping complete with fittings, flexible connection to IDU, necessary support as per specification and insulated with 6 mm thick fire rated class'O' closed cell elastomeric nitrile rubber insulation.
25 mm dia
32 mm dia
40 mm dia
SMOKE EXTRACTION/EXHAUST FAN
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung exhaust air tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, of class 'H' insulation etc. including all accessories complete as required and as per specifications. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows:
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.
Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard.
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS system of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
9000 CFM (15300 CMH) at 25 mm static pressure
12000 CFM (20400 CMH) at 30 mm static pressure -
AXIAL FLOW FANS (SUPPLY/PRESSURISATION FAN)
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung Supply/ Pressurisation tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, of class 'F' insulation etc. including all accessories complete as required and as per specifications. . Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows:
Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.
Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard.
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
Supply Fan
9000 CFM (15300 CMH) at 25 mm static pressure
12000 CFM (20400 CMH) at 30 mm static pressure -
INLINE FAN (Ceiling suspended)
Supply, installation, testing, commissioning of Inline fan with vibration isolators, speed regulator, GI gravity louvers, Bird Screen and required cable as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power Supply including fire retardant non-porous double layer flexible connection of the following capacity.
The louvers & bird screen shall be made of heavy gauge metallic construction.
600 CFM (1020 CMH) at 12 mm static pressure
800 CFM (1360 CMH) at 12 mm static pressure
1000 CFM (1700 CMH) at 15 mm static pressure
AIR DISTRIBUTION WORKS (DUCTING,INSULATION,DAMPER, GRILLE & DIFFUSER)
FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply, installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts complete with flanges, neoprene rubber gasket, elbows, Splitter Damper, vanes, hangers & support etc. as required as per IS/DW144/SAMACNA standard & confirming to specification. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
Note : Splitter Shall be a part of ducting.
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
SITE FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.
Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge)
FIRE RATED FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply. Installation, testing and commissioning of Fire rated sheet metal ducts shall be fabricated from Lock Forming Quality grade prime galvanized steel sheet with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Supporting distance shall not exceed 1.2 Mtr with 6mm thick fire retardant gasket suitable for 250 deg C 2 hr shall be used in duct joints along with fire sealants. Suitable access doors shall be provided at every 3m. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labor for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
All fire rated duct, smoke exhaust ducts shall be quoted with flame bar BWII or equivalent to achieve the required fire rating, also all the related accessories gaskets shall be suitable for the required fire rating.
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
1.25 MM (18 Gauge) Plenum & Exhaust Duct
Duct Insulation
Supplying , installation, testing & commissioning of external thermal insulation on ducts with Closed Cell Elastomeric Nitrile Rubber Insulation of density not less than 50±5 Kg/m³ & thermal Conductive not exceeding 0.032 W/mK at an average Temperature of 0°C and . The Material Shall be rated as Class 1 as per BS476 Part7 for surface spread of flame test and Class O as per BS476 part6 for fire propagation test. The Material shall have Fire Approval from CBRI - Roorkee & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993). Adhesive used for setting the insulation shall be non - flammable, Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12mm metallic Packing strip at every random meter & conforming to standard and Specification.
Duct Acoustic Lining
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 160 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Acoustic lining in ducts/plenum up to 5.0 Running meter from Fan Outlet as per specification and drawings.
20 mm For Duct
25 mm For Plenum
VOLUME CONTROL DAMPER
Supply,. Installation, testing and commissioning of 18 Gauge G.I construction Frame with 22/24 Gauge GI Aero foil blades Volume control Duct/Wall Dampers with linkages, levers & fittings for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.
MOTRIZED VOLUME CONTROL DAMPER
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room.
Motorized (ON-OFF Type) duct mounted GI volume control damper
Motorized (ON-OFF Type) duct mounted GI volume control Actuator
BACK DRAFT DAMPERS
Supply, Installation, testing and commissioning of 18 Gauge G.I construction Back draft Dampers for Controlling the recirculation of air with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum.
PRESSURE RELIEF DAMPERS
Supply,. Installation, testing and commissioning of 18 Gauge aluminum alloy extrusions with welded/cleated frames Pressure Relief Dampers for Controlling the Excess pressure up to 60pa with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum with suitable thickness.
AIR TERMINAL (SUPPLY/RETURN/EXHAUST)
Supply, installation, testing and commissioning of 50 micron Powder coated Aluminum extruded Air Terminal (Diffuser/Grille) as per specification & and drawings including fixing frames of GI in False ceiling/wall.
Supply. Installation, testing and commissioning of powder coated extruded aluminium section grills with aluminium dampers for supply air terminal and grilles without damper for return air for air-conditioning as per specification.
Grilles with Dampers
Grilles without Dampers
Diffusers
Supply. Installation, testing and commissioning of powder coated extruded aluminium square diffusers with antismudge ring and removable core.
Supply air with dampers
Return air without damper
Flexible Duct
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
Slot Diffusers
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
Linear Grille
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.
Exhaust/Fresh Air Louvers
Supply, Installation, Testing and Commissioning of Fresh Air/Exhaust air Louvers minimum 80 mm deep comprising of inclined blade and extended-out lowest blade for disposal of rain water including the wire mesh, filter (washable type filter section Class-G3 having efficiency >80% down to 20 micron fitted in aluminium frame) . The louver shall be of extruded Aluminum construction, and powder coated to the approved finish and color.
Under Deck Insulation of Exposed Roof
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50mm
ISOLATOR FOR OUTDOOR UNIT
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .
63A 4P MCCB(25 KA)
100A 4P MCCB(25 KA)
EARTHING STRIP/WIRES
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrode including connection/terminating with GI nut,bolt,spring,washer etc. as required.) jointing shall be done by overlapping &with 2sets of brass nuts bolt spring washer spaced at 50mm) 25mm x5mm
ELECTRICAL WORK
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
(Approved Make : Finolex/ Polycab /Nitcab / KEI / Havells)
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(Approved Make : Finolex/ Polycab /Nitcab / KEI / Havells)
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (approved make : AKG / BEC / Ppecision / Polycab)
20mm dia
25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (approved make : Legrand (Myrius) / Clipsal (C Vivace / Zencelo) / ABB (Classic Lumina ) / Wipro- North west (Stylus) / Anchor roma / MK (Wraparound Plus)
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Telephone Socket Outlet
TV anteena Socket Outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
4/5 Module (78mm x140mm x 50mm)
6 Module (78mmX205mmx50mm)
8/9 Module (78mmX230mmx60mm)
12 Module (135mmX205mmx60mm)
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.
Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required.
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (approved make : B.E.C. / AKG / Ppecision / RMCON)
20mm dia
25mm dia
Supply & drawing following sizes of FR PVC insulated copper conductor single core cables in existing surface/recessed steel / PVC conduit including dismantling as required. 2 x 1.5 sq.mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Approved make : Hager / Legrand / L & T / Schneider / Polycab)
8 Way Double Door
12 Way Double Door
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way (4+18), Double Door Horizontal Type
8 Way (4+24), Double Door Horizontal Type
Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required.
8 Way (4+18), Double Door Vertical Type
12 Way (4+24), Double Door Vertical Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6 / 32 Amp Single Pole
40 Amp DP
50/63 Amp DP
6/32 Amp TPN
40 Amp TPN
50/63 Amp TPN
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Providing and fixing H.T. danger Notice plate of 250mm x 200 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. (Approved make: Erico / Cape Electric / JMV / OBO )
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. (Approved make :Erico / Cape Electric / JMV / OBO )
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required(2*rate)
Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Horizental Run)
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. (for Vertical Run)
Providing and fixing testing Jointing made of 20mmx 3mm thick G.I Strip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required
Providing and Laying G.I tape 32mm x 6mm from earth electrode directoly in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
INSPECTION CHAMBER:
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with cable tie)
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Approved make : Siemens / Comet / Grippwel / Peeco / Dowells )
2 x 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (50mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
4 X 10 sq. mm (25mm) including 4x6 sq.mm
4 X 16 sq. mm (28mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Approved make : Pilco / BEC / MEM )
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required (Approved make : Pilco / Profab / BEC / MEM )
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. (Approved make : Pilco / Profab / BEC / MEM )
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (Approved make : Pilco / Profab / BEC / MEM )
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required (Approved make : Application control / SPC Electrotech / AR engineering / Amit Engineering)
125 A 15kA SC for 1 sec (including 100A & 63 A )
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required. (Approved make : ABB / Schneider / Legrand / L & T) 100 A, 25 KA,TPMCCB
MAIN L.T. PANEL
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required.
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
(Each Incomming / outgoing MCCB shall have microprocessor release and variable current setting from front, adjustable overcurrent, short circuit & earth fault protection, front extended lockable handle, pad lockable in off position, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables and as per specification.)
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
Note - Complete panel have BMS compactible. Manufacturer shall provide all types of ports, Potential free contact, Aux contactor as required for integration with BMS.
INCOMERS from 1 Nos. 630 KVA TRANSFORMER
1 nos. 1000 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history with intruppted current value during fault & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.
The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.
1 nos. 32 amp TP MCCB (25 KA) for OLTC (for each transformer incomer)
Protection releases / relays, Metering & Accessories for each Transformer incomers
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 1000/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 1000/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 no. CT's of ratio 800/5A, Class 5P20 for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Power factor meter.
Frequency meter.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from 2Nos. 250 KVA DG sets
1 nos. 630 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker, with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release (3 phase) with timer.
IDMT earth fault relay.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Reverse power relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 600/5A , Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 600/5A , Class 5P20 accuracy 20 VA each burden for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (250 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers.
BUSCOUPLER
1 nos 630 AMP. Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with inbuilt U/V release 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.
Protection releases / relays, Metering & Accessories for Bus Coupler (s)
Trip circuit supervision relay
TNC switch.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
BUS BARS
1000 AMP,TPN busbars of aluminium alloy as per SLD.
PLC for load management / automation
Design, manufacturing, testing at works, supply of PLC Based, Autoload Transfer, Autoload Balancing Panel For 2 nos. 250 KVA DG. sets complete as required to acheive the desired functions.
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.
PLC shall have with VIEW PANEL
In addition to required hardware and software following components shall also be provided.
Based on the load requirement only required no. of DG sets shall be operated.
Monitoring of DG set safeties (mechanical as well as electrical).
PLC Hardware as required
Auxiliary relays/contactor/metering/protection etc as required
230 V AC, UPS of suitable rating
Annunciators as required
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.
OUTGOINGS:
02 Nos. 400 Amp TP Moulded Case Circuit Breaker (25 KA)
02 Nos. 250 Amp TP Moulded Case Circuit Breaker (25 KA)
03 Nos. 200 Amp TP Moulded Case Circuit Breaker (25 KA)
03 No. 160 Amp TP Moulded Case Circuit Breaker (25 KA)
10 Nos. 100 Amp TP Moulded Case Circuit Breaker (25 KA)
02 No. 63 Amp TP Moulded Case Circuit Breaker (25 KA)
CAPACITOR BANK PANEL (180 KVAR - 1 SET) (PART OF MAIN L.T. PANEL)
INCOMING
1 No. 0 to 400 Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection SP MCB's (one set for each incoming breaker).
1 Sets breaker 'ON' & 'OFF' indicating lamp with protection MCB's (one set for each incoming breaker).
9 Step Automatic Power Factor Correction relay (APFC relay).
BUSBARS
500 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
1 No. Toggle switch for changing automatic to manual operation of capacitor units.
1 No. Power factor meter.
Main L.T. Panel cum capacitor panel Described as Above.
DISTRIBUTION PANEL
L+P PANEL ( GROUND & FIRST FLOOR ACADEMIC BLOCK)
INCOMING
1 No. 200 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 25 Amp FP MCB (10 KA)
6 Nos. 40 Amp FP MCB (10 KA)
5 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
L+P PANEL (GROUND, FIRST & SECOND FLOOR, R &D BLOCK)
INCOMING
1 No. 100 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
5 Nos. 25 Amp FP MCB (10 KA)
5 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
L+P PANEL ( SECOND FLOOR, ACADEMIC BLOCK )
INCOMING
1 No. 250 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 25 Amp FP MCB (10 KA)
6 Nos. 40 Amp FP MCB (10 KA)
10 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
UPS PANEL-1 ( ACADEMIC BLOCK)
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP copper busbar with coloured heat shrinkable sleeve.
OUTGOING
16 Nos. 63Amp DP MCB (10 KA).
Panel described as above
UPS PANEL-1 ( R & D )
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP copper busbar with coloured heat shrinkable sleeve.
OUTGOING
14 Nos. 63Amp DP MCB (10 KA).
Panel described as above
LIFT PANEL-1 ( TERRACE FLOOR )
INCOMING
2 No. 160 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 160 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
5 Nos. 63Amp FP RCCB (300 mA).
3 Nos. 40Amp DP MCB (10 KA).
Panel described as above
L+P PANEL ( STUDENT ACTIVITY BLOCK )
INCOMING
1 No. 160 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
8 Nos. 63 Amp DP MCB (10 KA) with KWH Meter
2 Nos. 40 Amp DP MCB (10 KA)
4 Nos. 25 Amp FP MCB (10 KA)
4 Nos. 40 Amp FP MCB (10 KA)
4 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No63 Amp FP Moulded Case Circuit Breaker (35 KA) with 63 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 40 Amp DP MCB (10 KA)
Panel described as above
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).
(Approved Make : Finolex / Polycab / Skytone / RR Kable / Havells )
3.5 core, 300 sq.mm.
3.5 core, 240 sq.mm.
3.5 core, 185 sq.mm.
3.5 core, 150 sq.mm.
3.5 core, 120 sq.mm.
3.5 core, 95 sq.mm.
3.5 core, 70 sq.mm.
3.5 core, 50 sq.mm.
3.5 core, 35 sq.mm.
4 core, 16 sq.mm.
4 core, 10 sq.mm.
4 core, 6 sq.mm.
2 core, 16 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 50 sq.mm PVC Insulated cu wire including termination etc.
1C x 16 sq.mm PVC Insulated cu wire including termination etc.
Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. (Approved make : Pilco / Profab / BEC / MEM )
100 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. (Approved make : Pilco / Profab / BEC / MEM )
150 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM
Ten Loop Panel.
Two Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.(Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.(Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of addressable manual call point complete as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing) (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying, installation, testing & commissioning of fault isolator complete with base as required. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supply, installation, testing and commissioning of addressable monitor module complete as per specification. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Approved Make :Universal(Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR )
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)
Supplying, installation, testing & commissioning of digital audio amplifier 480 Watt, supply complete as required. (Approved Make Honeywell / Bosch / Asquare / Toa)
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
Speaker cable Single pair, 2-core, 1.5 sqmm (Approved Make : Finolex / Polycab / Skytone / RR Kable / Havells )
SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANS
SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)
12W LED Round Down Light (Recess / Surface )
15 / 16 W LED Round Down Light (Recess )
18 /20 W LED Round Down Light (Surface)
18 /20 W LED Round Down Light (Recess)
2' x 2' LED Panel Light (Recess)
Bulk Head fitting with 9/10Watt LED.
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.
10/12 W LED Tube Light
20/22 W LED Tube Light
30 W COB based round LED Light with multiple beam angles (36 Degree)
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. (Approved Make :- Usha /Crompton / Havells / Bajaj) .
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required.(Approved Make :- Usha/Crompton / Havells / Bajaj) .
1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
UPS SYSTEM
Supply, fitting, fixing, testing and installation of 20 KVA, ON Line UPS three phase input and three phase out put power system of in put voltage range 360V/380/V/400V/485V AC , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor 0,8/3.1, Harmonic distrortion -< 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required. (Approved Make- APC / SOCOMEC / NUMERIC / ETON )
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transforme.
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
Suitable size of copper cable between UPS and battery bank shall be provided
UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
SITC of MS Battery Rack suitable for 15 to 20 UPS Battery Installation.
SITC of 60 nos. 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 20000 for 20 KVA UPS (65AH x 26 Nos. x 12V = 20280 VAH)
Total cost of 1 Set 20 KVA UPS, Batteries & Accessories (A+B+C)
Supply, fitting, fixing, testing and installation of 5 KVA, ON Line UPS Single phase input and Single phase out put power system of in put voltage range 110 V AC +/-5% 300V AC +/- 5% frequency range, 40Hz - 60Hz, Power factor ≥ 0,90@ full Load, and output voltage range 200V/208/220/230/240V AC voltage regulation ± 1% frequency range 50 Hz ± 0.25 Hz or 60 Hz ± . 30 Hz Harmonic distrortion -< 2% THD (Linear Load): 4% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required. (Approved Make- APC / SOCOMEC / NUMERIC / ETON )
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transforme.
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
Suitable size of copper cable between UPS and battery bank shall be provided
SITC of MS Battery Rack suitable for 15 to 20 UPS Battery Installation.
SITC of 60 nos. 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 5460 for 5 KVA UPS (65AH x 7 Nos. x 12V = 5460 VAH)
Total cost of 1 Set 5 KVA UPS, Batteries & Accessories (A+B+C)
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS
(Approved Make :- Alcatel / Extreeme / Cisco / Aruba) .
Supply, Installation, Testing & Commissioning of Cat 6, 24 Port Patch Panel
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 3 feet for rack and user end termination - 1Mtr
Supply, Installation, Testing and Comissioning of Cat 6 patch cord 7 feet for rack and user end termination - 2Mtr
Supply, Installation, Testing, Commissioning of Cat 6, Information Outlet (I/O) including G.I. Box and modular cover plate.
Supply, Installation, Testing and Comissioning of 24U floor mounted Rack with accessories.
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE.
Supply, Installation, Testing & Commissioning of EPABX SYSTEM Configuration as Below:- Analog Trunk Line 6 Nos. Digital Line 2 Nos Analog Extensions 100 Nos.
Supply, Installation, Testing & Commissioning of Digital Phone for Operator Console
Supply, Installation, Testing & Commissioning of Type Analog Phone with speaker phone, .
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable.
IP CCTV SYSTEM
Supplying, installation, testing & commissioning of 1080p HD Indoor IP Dome camera with1/3-inch CMOS, Sensor pixels 1920 x 1080, Sensitivity-0.04 lx (color) , Dynamic range 75 dB Wide Dynamic Range (WDR), True day/night, Automatic Electronic Shutter, Video compression H.264 ; M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio detection, Privacy Mask, Lens 3.6 mm lens, 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE Certified. (Approved Make: Honeywell / Tyco / Uniview / Bosch).
Supplying, installation, testing & commissioning of 5MP 30 fps HD indoor / outdoor IR IP bullet camera with 1/3‑inch CMOS, Sensor pixels 2612 (H) x 1980(V), Sensitivity-0.24 lx (color) 0.04 lx (mono) ,IR range 30 mtrs, Dynamic range 70 db, True day/night, Automatic Electronic Shutter, Video compression H.264 MP ; M-JPEG, White balance, BLC, Analog video output, Lens (zoom / focus) 3.6 mm lens, Two-way, full duplex Audio, Audio compression AAC, G.711, L16 , ONVIF Profile S, CE Certified. (Approved Make: Honeywell / Tyco / Uniview / Bosch).
Supply installation and commission of pann tilt zoom camera with 360 deg pan and 90 deg tilt with 36 X Zoom having maximum resolution of Max. 1920 × 1080 @30fps,true day night camera with 130 m IR range , optional, fine picture at Ultra-low light,supports compression format H.265, H.265+, H.264+, H.264, 3D Digital Noise Reduction support. (Approved Make: Honeywell / Tyco / Uniview / Bosch).
SITC of IP network recoder with following feature Processor - Dual-core embedded processor . Two-way Talk - 1 channel Input, 1 channel Output, RCA,Video Output - 1 HDMI, 1 VGA , IP Camera Input - 8/16/32 Channel IP , Compression - H.264+/H.264/MJPEG,Video Resolution - 2560 × 1920, 2048 × 1536, 1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768 , Hard Disk - 4 SATA Ports, up to 8TB ,Motion Detection - MD Zones: 396 (22 × 18),Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Camera Blank, Video Loss), Alarm, Stop, Backup Mode - USB Device /Network , Interface Ports - 1 HDMI, 1 VGA, 2 USB(1 USB 2.0 , 1 USB 3.0 ), 1 RS485, 1 RS232, 1 RJ45. (Approved Make: Honeywell / Tyco / Uniview / Bosch).
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required. (Approved Make : D- Link, CISCO / NETGEAR )
Supply, installation, testing and commissioning of of 6 TB HDD all accessories complete as required.(Approved Make- WD / Samsung)
Supply installation and commissioning of 48 inch LED monitor for disply of camera. (Approved Make : Samsung / sony )
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM IN PANELS
Supply, fixing, testing and commissioning of Automatic Linear pneumatic Tube Detection based Novec 1230 System for Electrical Panels (consisting of the following components.
Approved Makes - Firemech / Nohmi / Ceasefire / Tyco / Firetrex)
6 KG Novec 1230, DLP Assembly with automatic valve mounted on approved cylinder, push in connector for tube, Novec 1230 gas, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Linear pneumatic heat Detection Tube with all necessary fittings & supports
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 325 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
DG SET & SUBSTATION WORK
DIESEL GENERATING SET
Supply, Installation testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Approved Makes - Cummins / Sterling / MTU Caterpillar / Kirlosker
Diesel Engine -
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required.
Approved Makes - Stamford / Leroy Somer / Greaves / Marathon
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)
150 mm dia (wall thickness - 4.85 mm)
Supply & fixing of SS Bellow of following diameter 150 mm dia
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
11 KV HT VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE)
Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device.
Approved Makes - ABB / Siemens / Schneider / Tricolite / Ambit / ADLEC /
Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C x 300 sq.mm. XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item).
a) 1 No, 630 Amp, VCB.
d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
e) 1 No - set of dual core dual ratio 3 CTs 100/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
g) 1 No. hooter with hooter acceptance and reset push button.
h) 1 No - Red, Yellow & Blue for phase indication.
i) 1 No - Amber for Trip indication.
j) 1 No - Red `ON' Green `OFF'indication.
k) 1 No - Spring charge indication.
l) 1 No - Auto trip indication.
m) 1 No. hooter with hooter acceptance and reset push button.
n) 1 No. master trip relay. ( Electromechanical Type )
o) 1 No.Trip ckt supervision relay. (Electromechanical Type )
a) Outgoing - 2 No, 630 Amp, VCB.
c) 2 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
d) 2 No - set of dual core dual ratio 3 CTs 100/5 A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
e) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
f) 2 No. hooter with hooter acceptance and reset push button.
g) 2 No - Red, Yellow & Blue for phase indication.
h) 2 No - Amber for Trip indication.
i) 2 No - Red `ON' Green `OFF'indication.
j) 2 No - Spring charge indication.
k) 2 No - Auto trip indication.
l) 2 No. hooter with hooter acceptance and reset push button.
m) 2 No. master trip relay. ( Electromechanical Type )
n) 2 No.Trip ckt supervision relay. (Electromechanical Type )
o) 2 No.auxiliary relay for transformer fault.
p) Power pack.
H.T. Panel described as above
TRANSFORMER
Design, manufacture, supply, installation, testing and commissioning of out door type copper wound transformer continuously rated for 3Ph 50 Hz at full load rating the transformer should have oil immersed winding having vector group DY-11, HT side connected in star with neutral brought out connected to provide separate earthing. The transformer shall have power terminal arrangement bushing / cable end box on HT side and cable end box on LT side. 630 KVA, 11 KV /0.415 KV, 3 phase, 4.5 % impedance, 50 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the Transformer. The transformer should have following standard as per amended IS specification and the load * no load losses shall be limited to the values given below or as per IS 2026 and latest IS-1180 or Norms issued by SEB which ever are Lower.
Approved Makes - Crompton / ABB / Schneider / Voltamp / Sudhir Intra / Esennar
Oil Conservator with filling hole with cap and plain oil level gauge.
Silica gel dehydrating breather charged with silica gel.
Oil drain Valve
Oil Filter Valve
Lifting eyes / Hooks
Two earthing Terminals
Diagram and rating plate
Air Vent
Explosion Vent
100 mm dia thermo meter with thermometer pocket
Four bi directional plain roller
Buchholz relay
Resistance Temp detector
Marshalling box
Automatic Voltage Regulator ( AVR)
Remote Tap Changing controller ( RTCC)
Transformer 11000/415 volts with on load Tap changer -15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 185 Sqmm, 11KV XLPE
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 185 Sqmm, 11 KV XLPE
Laying of one number additional PILCA / PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sqmm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.
Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.
4 core, 2.5 sq.mm.
10 core, 2.5 sq.mm.
12 core, 2.5 sq.mm.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd
EXTERNAL LIGHTING
S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)
60W LED Street Light
S.I.T.C of Following rating LED Post Top lamp made in die cast aluminium housing with decorative clear / opel acrylic diffuser on existing pipe including connection with 1.5sq.mm coppwr conductor etc all complete as required. (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)
20/25W LED Post top lamp clear
S.I.T.C of Following rating approved make LED Bollard Fitting with cylindrical shape and inverted cone shape head of height 600 to 850 mm power input -8/9 watt with die cast aluminium housing opel with PC diffuser, IP-65/54 protection, conferming to IS : 10322 part 5 etc all complete as requird. (Excluding Plinth Charge.) (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm). (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.)
1m Single Arm Suitable for 70MM Top
Supplying & installation of 7 mtr. Height galvanized Mild Steel decorative lights post with LED 60 watt.light. Top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (with Arm). (Approved Make:- Philips/Crompton/ Wipro/ India Bulls.) Post Top Light WITH POST
HORTICULTURE WORK
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of IS designation 20 mm
Screened through sieve of IS designation 16 mm
Screened through sieve of IS designation 4.75 mm
Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment)
PREPARATION WORKS
Fine dressing of the ground
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m diameter and 1.2 m deep
Holes 90 cm diameter and 90 cm deep
Holes 60 cm diameter and 60 cm deep
Holes 45 cm diameter and 45 cm deep
TREES
EVERGREEN TREE
Azadirachta Indica,Neem
Alstonia scholaris,Devil tree
Ficus benjamina,weeping fig
FLOWERING TREE
Bauhinia purpurea,Kachnar
Callistemon lanceolatus,Bottle brush
Delonix regia,Gulmohar
Cassia fistula,Golden shower
Plumeria alba,white champa
Plumeria rubra,pink champa
foxtail palm
BAMBOO
Buddha belly bamboo
SHRUBS
Clerodendrum inerme,Volkameria inermis
Ficus panda
Ficus benjamina Starlight,Ficus Starlight
Gardenia jasminoides
Golden duranta
Hamelia patens
Hibiscus rosa-sinensis,udhul
Raphis excelsa,lady palm
Tecoma gaudichaudi,Yellow bells
TMC dwarf,Chandani
GROUND COVERS
Alternanthera red
Chlorophytum comosum
Jatropha
Sprenger's asparagus,Foxtail fern
Syngonium podophyllum,Syngonium butterfly
Tradescantia pallida
GRASS
Cynodon dactylon,doob grass
FURNITURE WORK
Providing and Placing Cabin Table. Table Dimensions as mentioned above. Main Table and Side Table made of 36 mm thick Pre Laminated Particle Board with matching 2 mm thick edge Banding. Modesty panels are in 18mm thk Postlaminated finish. The Table tops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Table supports are combination of Metal poles and Gable ends. Access Flap with Cable tray and switch mounting plate is provided on side table for wire management. Back storage unit is Hinged Door unit Back Unit is made of Prelaminated particle Board 18mm thick with Matching PVC lipping.
Main Table :- W1950xD750xH750mm
Main Table :- 1350xD750xH750mm
Return :- 1050xD450xH750mm
Back Storage :- W2700xD450xH750mm
FA 302 SPECIFICATIONS: Back Height - High Back w/Headrest Back Finish - Mesh with Lumbar Support Back Mesh Color - Black Seat Finish - Fabric/ Mesh Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - Fixed arms Base Type - Black nylon base Main Chair
FA 304 Back Height -High Back w/Headrest Back Finish - Mesh with Lumbar Support With Coat Hanger Stand Back Mesh Color - Black Seat Finish - Fabric/ Mesh Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - Fixed Arm Base Type - Black Nylon base Main Chair
FA 308 Back Height - High Back with headrest Back Finish - Mesh with adjustable lumbar support Back Frame - Black Color Seat Finish - Fabric Seat Height Adjustment - Pneumatic Mechanism - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - Fixed arm Armpads Type - Polyurethane Base Type - Nylone Base Visitor Chair
Straight workstation of size 1200x600mm, having prelaminated top supported with "Jazz-45" partition 1200mm with one no. magnetic tackable and one no. marker tile per person. Lower tile of partition is lamiated and upper is fabric. System has twin raceway one at skirting level and 2nd is above/below worktop level. Partition Thickness is 45mm . All metal Parts are Powder Coated. Workstation :- W1200xD600xH1200mm
Corner workstation of size 1500x1500mm, having prelaminated top supported with "Jazz-45" partition 1200mm with one no. magnetic tackable and one no. marker tile per person. Lower tile of partition is lamiated and upper is fabric. System has twin raceway one at skirting level and 2nd is above/below worktop level. Partition Thickness is 45mm . All metal Parts are Powder Coated. L - Shape Worstation :- W1500x1500xD600xH1200mm
Three drawer pedestal with levelers made up from 18mm thick prelaminated of 400mm (W) x 450mm (D) x 621mm (H) with central locking arrangement. The unit and 2 no. box and 1flile drawer fitted with roller slides. Pedestal :- W400xD450xH621mm
FA 602 SPECIFICATIONS: Back Height - Medium Back Back Finish - Mesh with Lumbar Support Back Mesh Color - Black Seat Finish - Fabric/ Mesh Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - Fixed arms Base Type -Black nylon base WARRANTY: 1Years from the date of invoice Workstation Chair
FA 508 Back Height - Medium Back Back Finish - Mesh Back Frame - Black Color Seat Finish - Fabric/ Mesh Seat Height Adjustment - Pneumatic Mechanism -Swivel Tilt Mechanism Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - Fixed Arm With Seat Back Base Type - Nylone Base Warranty : 1 years from the date of invoice Reception Chair
Providing & Supplying student desk. Student desk having dimesion as mentioned above. Table top is made up from 25mm thick prelaminated particle board with 2mm thick pvc egde lipping. Table top supported on 60mm x 30mm pipe section CRCA powder coated legs.
Table :- W600xD600xH750mm (For 1 Person)
Table :- W1350xD600xH750mm (For 2 Person)
Cabin table having main table of size 1200x600mm made from 25mm thick prelaminated top with 2mm PVC lipping all across the boarder, supported on gable end with laminated modesty panel in front. Main Table :- W1200xD600xH750mm
Providing & Supplying student desk. Student desk having dimesion as mentioned above. Table top is made up from 25mm thick prelaminated particle board with 2mm thick pvc egde lipping. Table top supported on 60mm x 30mm pipe section CRCA powder coated legs. Table :- W1350xD600xH750mm (For 2 Person)
Providing & Fixing of sofa. The inside frame is made of seasoned wood and has antitermite treatment. The seat and back are made of foam and is finished in leatherite upholestry. The structure is supported on Polished Solid Wood Legs. Leatherite colour and type as per directions of Engineer in Charge. The above furniture should be as per specification and sample approved by client.
1 Seater Sofa
2 Seater Sofa
3 Seater Sofa
Corner Table having dimension 500mm L x 500mm W x 400mm H with completely made of 25mm thick prelaminated particle board . Verticals also made of 25mm Particle board. All edges are sealed with 2 mm thick PVC Lipping. 25mm thick particle board Top with edges sealed with PVC lipping. 25mm thick particle board Gable ends with edges sealed with PVC lipping. 18mm thick particle board Modesty panel with edges sealed with PVC lipping. 0-20mm adjustable levelers. Corner Table :- W500xD500xH400mm
Providing & Fixing Make Conferece Table of Size 7650mm L x 1200mm D . The Worktop shall be made of 25mm Prelamparticle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MSof 1.5mm thickness in powder coated finish of 50 microns thickness . The above furniture should be as per specification and sample approved by client. Conferece Table :- W7650xD1200xH750mm
Providing and supplying Reception Desk having Dimension 1650mm L x 600mm x 1185mm Height . It has 25mm thick Worktop and Gable Ends made of pre Laminated Particle Board sealed with PVC Edge Banding. Front and Modesty Panel are 18mm thick Pre Laminated ParticleBoard Sealed with PVC EdgeBanding.. The Counter Top is 25 mm Thick Postformed ParticleBoard. Unit has One Pull out drawer with Lock and Handle. Reception Table :- W1650xD600xH 1185mm
Providing & Supplying Café Table of size 1800mm (W) x 900mm (D) x 750mm (H). Table Top made up from 25mm thick prelaminated particle board with 2mm thick pvc edge banding. Table top supported on CRCA powder coated metal legs. Café Table :- W1800xD900xH750mm
Providing & Fixing of Cafe table of Size 1200 mm dia. The Worktop shall be made of 25mm Prelamparticle Board with 2mm thick PVC lipping. Understructure is SS base of Dia 580mm.The above furniture should be as per specification and sample approved by client. Round Café Table :- W1200mm Dia.
VISION CAFE Back & Base Finish - Plastic Colour Options : Blue/red/green/Yellow/Black Café Chair
Providing & Supplying Café Table of size 1800mm (W) x 900mm (D) x 750mm (H). Table Top made up from 25mm thick prelaminated particle board with 2mm thick pvc edge banding. Table top supported on CRCA powder coated metal legs. Table :- W1800xD900xH750mm
VISION CAFE Back & Base Finish - Plastic Colour Options : Blue/red/green/Yellow/Black Chair
Centre table in position with sizes 900 mm L x 500mm D x 400mm H with completely made of 25mm thick prelaminated particle. The Table have one pull out drawer and another shelf at lower level. 25mm thick particle board Top with edges sealed with PVC lipping. 25mm thick particle board Gable ends with edges sealed with PVC lipping. 18mm thick particle board Modesty panel with edges sealed with PVC lipping. 0-20mm adjustable levelers. 1 Drawer. Centre Table :- W900xD500xH400mm
Supply & Installation of DUSTBIN 100 Litres litres HDPE waste containers or rigid liners.Utility-Public (Mobile containers confirming IS: 12402).Material -HDPE.Bin Capacity (Volume) (Ltrs)-100 Litres.Wall -Non- Perforated.Lid -Swing type.Weight of Dustbin (Complete unit) (Grams)-12500.Gripping Provision-Both Frontal &Ventral.Dust Bin stand -With.No. of Compartments in the Bin-Twin Bin.All complete work as per E/I.
Supply and Installation of Cast Iron Powder Coating Garden Bench, Capacity 3 Seater (GARDEN BENCH 3 SEATER KB).Seating Capacity -3 Seater.Finsh-Powder Coating .Weight Bearing Capacity-110 kilogram.Side Frame Material-Cast Iron.Seat Material & Back Rest Material -Mild Steel Pipe 14 Gauge.Total Height -915 millimeter.Seat Height -401 millimeter.Width-450 millimeter.Total Area Required-1550 millimeter.All complete work as per E/I.
SIGNAGE
Providing & Fixing Stainless Steel Letter fixed on MS Frame (15' x 3')
Providing & Fixing MS Frame Support for External Signage
Providing & Fixing Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade.
Providing & Fixing Backlit Acrylic Box Lit with Korean Led (4ft X 1.5ft)
Providing & Fixing Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back
Providing & Fixing Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back (4 inch 18inch by)
Providing & Fixing One Way Vision - About BIT Sindri
Providing & Fixing Froasted / One Way Vision film (make 3M or equivalent)
Providing & Fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required (4 x 4)
Providing & Fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required (4 x 2)
Providing & Fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required(4ft x 4ft)
Providing & Fixing MS Frame with Guarder supported from Wall
Providing and fixing of Photoluminescent, 1mm rigid PVC based sheet containing lumingen 3, as base chemical, with high intensity luminous glow capacity. each sign which is required to be mounted on wall surface shall be MOUNTED ON 3MM ROUTER CUT Aluminium composite panel with 25mm boarder all around over the size of photoluminescent sign, ACP shall have rounded corners and fixed on wall surface as per drawing.
PHOTOLUMINESCENT, FIRE HOSE & Stairs
PHOTOLUMINESCENT, FIRE ALARM CALL POINT
PHOTOLUMINESCENT, PULL AND PUSH
Providing and fixing of edge lit ,emergency exit sign with 2 hrs power back up, concealed in false ceiling as per approval of Architect/EIC.
Supply Installation, Testing & Comissioning) AUDIO AND VIDEO SYSTEM
Laser Projection, Celing Mount
Motorized Screen
HDMI Transmitter & Receiver Kit with splitter & switcher as requiired & cables
55" Display for repeat parallell view, with mounting kit
HDMI Transmitter & Receiver Kit with splitter & switcher as requiired & cables
Interactive Smart Board Camera with Sensors
White Board 6'X4'
Short Throw Projector with wall mount Kit
Power Amplifier 1000 Wt
200W Amplifier
100W Amplifier
30W Column Speaker with base
20W Column Speaker
Speaker Cable Mount & other accessories
Speaker Cable Mount & other accessories
Teacher Mic
Microphone Set with laper & handheld for teachers
Add 18% GST
Add 1% Labour cess 1%
RAJBIR CONSTRUCTION PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html