| 1 | L1₹4.0 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹4.2 L+₹3,691 (0.89%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹5.5 L+₹1.4 L (32.6%)Rejected-Finance 589 BC BAZAR AMBALA CANTT AMBALA | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹5.6 L+₹1.5 L (36.2%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
8 Feb 2025, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR / MAINT / REPLACEMENT OF INTERNAL WIRING, FITTINGS AND FIXTURE AND CERTAIN MISC E AND M ITEMS IN ZONE-B AND OTHER AREAS OF DEFENCE LAB JODHPUR
2025_MES_693431_1
8636/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹10,000
Yes
18 Mar 2025
16 Jan 2025
10 Feb 2025
16 Jan 2025
8 Feb 2025
25 Jan 2025
17 Jan 2025 - 24 Jan 2025
Amount
Taking down old unsv copper/aluminium point wiring (light, fan, socket or power etc) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking schedule of credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Material and labour for point wiring in replacment of unsv complete with 1.5 sq mm single core multi stranded copper conductor PVC FRLS insulated unsheathed 1100 Volt grade cable in and incl PVC FRLS new casing capping (new ISI Mark) or in existing concealed conduit with accessories including new pressed steel terminal boxes (sunk in wall) with 3.00 mm thick plastic laminated sheet top cover or PVC FRLS board including PVC FRLS top cover or Modular sunken box with modular plate and cover with 1.50 sq mm insulated unsheathed PVC FRLS multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour all as specified and directed for :-
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
(c) One socket out let 5 Amps 5 Pin on same board with other switch
(d) One socket out let 5 Amps 5 pin on independent board
(e) One call bell point controlled by one bell push .
(f) One light point controlled by two switch two way
All as per item No 2 here in before but with single core multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed for:-.
(a) One socket outlet 15 Amp power point on Independent board.
Material and labour for replacement of unsv Elect bell AC 230 Volts single phase musical type
Material and labour for replacement of unsv bell push flush type 5 Amps .
Supply and fixing in replacement of switch piano flush type 5 Amps single pole one way
Supply and fixing in replacement of switch piano flush type 5 Amps single pole two way.
Supply and fixing in replacement of socket out let 2 in 1 multi pin 5 Amps flush type universal.
Supply and fixing in replacement of switch piano15/16 Amps one way 240 volts
Supply and fixing in replacement of socket outlet in replacement of 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts SP
Supply and fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.
Supply and fixing in replacement of Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal Complete.
S&F in replacement of modular bell push 6 Amps single module
Supply and fixing in replacement of modular switch 6 Amps single module one way.
Supply and fixing in replacement of modular switch 6 Amps single module two way.
Supply and fixing in replacement of modular socket 6 Amps 5 pin double module.
S&F in replacement of modular switch 16 Amps single module
Supply and fixing in replacement of modular socket 6&16 Amps 5 pin double module.
Supply and fixing in replacement of moduler Fan step regulator, two module
Supply and fixing in replacement of on off push switch 25A two module
Supply and fixing in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps.
Supply and fixing in replacement of Lamp Holder, PVC FRLS/polycarbonate type with back plate suitable for batten fittings.
Taking down old light fittings and Supply and fixing in replacement of LED Tube light 20 Watt High-quality materials and design Extruded channel in thermally conductive materials High translucent serrated milky white diffuser is used to get glare free and smooth light distribution
S&F in replacement of LED 15 watt Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S&F in replacement of LED 36/40 watt (2X2 feet) Environmental friendly, ultra modern, energy saving, surface or ceiling, recessed mounted decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S&F in replacement of LED 36/40 watt (1X4 feet) Environmental friendly, ultra modern, energy saving, surface or ceiling, recessed mounted, decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S&F in replacement of LED 12/15 watt Environmental friendly, ultra modern, energy saving, surface (round / square type) or ceiling, recessed mounted, decorative LED luminaire comprising of high brightness LEDs, IP54 protection complete all sepcified and directed.
S&F in replacement of LED Decorative wall light fixture made up of Polycarbonate, suitable for LED Bulb 09/12W(B-22 base) complete all sepcified and directed.
Taking down old submain wiring and Supply and fixing in replacement wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6.0 Sqmm and one run of 6.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade as earth (colour of wire : Phase-Red, Neutral-Black, Earth-Green) lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down old submain wiring and Supply and fixing in replacement wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4.0 Sqmm and one run of 4.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade as earth (colour of wire : Phase-Red, Neutral-Black, Earth-Green) lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down old submain wiring and Supply and fixing in replacement wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10.0 Sqmm and one run of 10.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade as earth (colour of wire : Phase-Red, Neutral-Black, Earth-Green) lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down old submain wiring and Supply and fixing in replacement sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10 Sqmm and one run of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: four runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down old submain wiring and Supply and fixing in replacement sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6.0 Sqmm and one run of 6.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: four runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Taking down old submain wiring and Supply and fixing in replacement wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2.5 Sqmm and one run of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade as earth (colour of wire : Phase-Red, Neutral-Black, Earth-Green) lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed/open in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
Supply, fixing, connecting & testing sheet metal enclosures double door, TPN, 4 way 415 V ,DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 250 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
S&F MCB 240 volts SPN 40-63 amp 10KA breaking, capacity, ISI marked, including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
S&F MCB 240 volts SPN 32 amp 10KA breaking, capacity, ISI marked,including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
S&F MCB 240 volts SP 6- 32 amp 10 KA breaking capacity ISI marked, including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
S&F MCB TPN 415 volts 63 amp 4 pole 16 KA breaking capacity, ISI marked including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
Taking out old and Supply and fixing in replacement of 15 amp plug top 3 pin for power equipment etc complete all as specified and directed by EIC.
Taking out old earthing and M&L for replacement of old unsv Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground, connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts, bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X 30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.
SHRI BHIKSHU ART AND CONSTRUCTION CO (BID ID -3235243)
VARDHMAN SALES CORPORATION (BID ID -3234913)
M/S Balkishan Panwar Construction (BID ID -3234854)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .