| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.3 L+₹49,841 (1.57%)Rejected-AOC | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹32.7 L+₹90,727.50 (2.85%)Rejected-AOC | L3 | Rejected-AOC Being L3 |
| Sl No | Description | Qty | Unit | SAI RAM CONSTRUCTIONS L1 | S J REDDY L2 | Sri Sai Krishna Construction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete or surkhi filling of any description and in any position not otherwise specifically provided for Roof treatment and in sunken treatment etc complete all as specified and as directed. | 65 | Cum | 200 ₹13,000 Lowest | 720 ₹46,800 | 800 ₹52,000 |
| 2.00 | M&L Cement concrete type B-1 1:2:4 (20mm graded aggregate) in roof padding concerte of average 50 mm thick with liquid water proofing compound as per manufacturers instructions etc complete all as specified and as directed. Note: WPC will be measured & paid separately under relevant Item | 1,050 | Sqm | 300 ₹3,15,000 | 306 ₹3,21,300 | 250 ₹2,62,500 Lowest |
| 3.00 | M & L Cement concrete type B-0 1:2:4 (12.5mm grades aggregate) in haunching concrete etc complete all as specified and as directed | 2 | Cum | 4,000 ₹8,000 Lowest | 7,200 ₹14,400 | 6,900 ₹13,800 |
| 4.00 | M&L for Rendering 10mm thick in cm 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surface is still green including finished even and fair etc complete all as directed. Note: WPC will be measured & paid separately under relevant Item | 1,050 | Sqm | 200 ₹2,10,000 | 270 ₹2,83,500 | 180 ₹1,89,000 Lowest |
| 5.00 | (i) Removing existing water proofing treatment of any description, any type on roofs, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge.
(ii) While doing the treatment on existing roof, concrete should be thoroughly inspected for any significant distress, if any shall be repaired. rehabilitated and treated. Pipes over roof shall be realigned where ever required.(measured separately)
(iii) Cleaning the surface of roof & up to 300 mm of parapets and crumple joint including junction of roof and parapet, providing and laying fixing TPO (Thermoplastic Polyolefin) waterproofing membrane STP LIMITED SHALI TPO (Minimum 1.2 mm thick) applied by using SHALI BOND TPO Adhesive @ 500 grms per sqmt, for fully bond Membrane to surface , as per manufacturer’s instructions.Over a min 200 GSM Geo textile or Asian Paints TPO or equivalent product of M/s MC Bauchemic / CIPY/ SIKA/ Pidilite or Dr Fixit TPO membrane, applied as per manufacturer's instructions.
(iv) The work shall be carried out complete as per
application and manufacturer's specifications authorised methodology. Execution to be done with trained/ skilled applicator of manufacturer as per the technical guidelines laid by manufacturer, Company guarantees to be given by contractor after completion of water proofing work before payment. | 970 | Sqm | 1,500 ₹14,55,000 | 1,440 ₹13,96,800 Lowest | 1,650 ₹16,00,500 |
| 6.00 | (i) Removing existing water proofing treatment of any description, any type on roofs, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge.
(ii) While doing the treatment on existing roof, concrete should be thoroughly inspected for any significant distress, if any shall be repaired. rehabilitated and treated. Pipes over roof shall be realigned where ever required(measured separately).
(iii) Cleaning the surface of roof & up to parapets and crumple joint including junction of roof ,apply TPO Membrane upto parapet, providing and laying / fixing TPO (Thermoplastic Polyolefin) waterproofing membrane STP LIMITED Shali TPO HG FB (Minimum 1.5 mm thick) , applied by using SHALI BOND TPO Adhesive @ 500 grms per sqmt, for fully bond Membrane to surface , as per manufacturer’s instructions.
(iv) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per the technical guidelines laid by manufacturer, Company guarantees to be given by contractor after completion of water proofing work before payment. | 230 | Sqm | 1,500 ₹3,45,000 Lowest | 1,530 ₹3,51,900 | 1,800 ₹4,14,000 |
| 7.00 | Providing and carry out expansion joint treatment after proper surface preparation to remove loose mortars, dust, foreign particles from joints, fixing of tightly packed closed cell polyethylene based back up rod or filler board to ensure no gaps or voids exists, mask face edge of the joint using masking tape for neat finish, application of polyurethane or polysulphide sealant (width to depth : 2:1 ratio) and allow it cure for 2 days. Mixing of Two part Epoxy Adhesive using slow speed drill till get homogeneous mix, apply it to prepared joint 1-2mm thick with notched trowel or putty blade, tooled to a smooth finish and finally fixing of Flexible expansion joint (FPO Tape) membrane Dr. Fixit Seal Tape/ Hydro gap shield available in 1mm thickness and 150 mm wide exhibiting superior mechanical properties like, Elongation >500%, Tensile Strength >12N/mm2, Tear Strength >200N above joint followed by another layer of epoxy adhesives as complete as per manufacturer’s specification. Epoxy adhesive shall be applied on outer edges of tape. For joint over end laps, the overlaps surfaces must be clean, wiped and lapped with 100 mm overlap. After application the system should be allowed to cure for 7 days. | 20 | Rm | 500 ₹10,000 Lowest | 900 ₹18,000 | 3,800 ₹76,000 |
| 8.00 | Removal of debris (Aggregates) obtained from demolition including loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed. | 105 | Per Load | 500 ₹52,500 | 270 ₹28,350 | 200 ₹21,000 Lowest |
| 9.00 | M&L for Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding , any type , any location/height( roof, parapet walls near pipes etc) and spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions after removing roots from wall slabs for preventing the regrowing and making good the disturbed portion using PCC 1:2:4 type B-0 with 12.5mm graded aggregate and plaster in CM 1:3 (Size of the disturbed portion 150X150X150mm) etc complete all as specified and as directed. | 15 | Each | 500 ₹7,500 | 225 ₹3,375 | 100 ₹1,500 Lowest |
| 10.00 | Cutting out V groove on cracks of walls and cleaning out, wetting, grouting with crack filler (Dr Fixit or equivalent) mixing with cement slurry, making good the surface by using CM 1:3 or PCC 1:2:4 type B-0 as required at site, as per manufactures instuctions, of any description and in any position, with necessary scaffoldings, as approved by Engr in charge | 40 | RM | 100 ₹4,000 | 207 ₹8,280 | 80 ₹3,200 Lowest |
Tender Value
₹44.4 L
EMD Value
₹88,738
Closing Date
16 Jul 2025, 6:00 pmClosed
GE (AFA) HYDERABAD
GE (AFA) Hyderabad, Dundigal, Hyderabad
SPECIAL REPAIRS TO BLDG NO.345B (NAVKIRAN CINEMA HALL) AT AFA HYDERABAD
2025_MES_715330_1
8578/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) HYDERABAD
₹88,738
Yes
5 Jan 2026
18 Jun 2025
18 Jul 2025
18 Jun 2025
16 Jul 2025
2 Jul 2025
18 Jun 2025 - 1 Jul 2025
Amount
Demolition of cement concrete or surkhi filling of any description and in any position not otherwise specifically provided for Roof treatment and in sunken treatment etc complete all as specified and as directed.
M&L Cement concrete type B-1 1:2:4 (20mm graded aggregate) in roof padding concerte of average 50 mm thick with liquid water proofing compound as per manufacturers instructions etc complete all as specified and as directed. Note: WPC will be measured & paid separately under relevant Item
M & L Cement concrete type B-0 1:2:4 (12.5mm grades aggregate) in haunching concrete etc complete all as specified and as directed
M&L for Rendering 10mm thick in cm 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surface is still green including finished even and fair etc complete all as directed. Note: WPC will be measured & paid separately under relevant Item
(i) Removing existing water proofing treatment of any description, any type on roofs, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge. (ii) While doing the treatment on existing roof, concrete should be thoroughly inspected for any significant distress, if any shall be repaired. rehabilitated and treated. Pipes over roof shall be realigned where ever required.(measured separately) (iii) Cleaning the surface of roof & up to 300 mm of parapets and crumple joint including junction of roof and parapet, providing and laying fixing TPO (Thermoplastic Polyolefin) waterproofing membrane STP LIMITED SHALI TPO (Minimum 1.2 mm thick) applied by using SHALI BOND TPO Adhesive @ 500 grms per sqmt, for fully bond Membrane to surface , as per manufacturer’s instructions.Over a min 200 GSM Geo textile or Asian Paints TPO or equivalent product of M/s MC Bauchemic / CIPY/ SIKA/ Pidilite or Dr Fixit TPO membrane, applied as per manufacturer's instructions. (iv) The work shall be carried out complete as per application and manufacturer's specifications authorised methodology. Execution to be done with trained/ skilled applicator of manufacturer as per the technical guidelines laid by manufacturer, Company guarantees to be given by contractor after completion of water proofing work before payment.
(i) Removing existing water proofing treatment of any description, any type on roofs, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge. (ii) While doing the treatment on existing roof, concrete should be thoroughly inspected for any significant distress, if any shall be repaired. rehabilitated and treated. Pipes over roof shall be realigned where ever required(measured separately). (iii) Cleaning the surface of roof & up to parapets and crumple joint including junction of roof ,apply TPO Membrane upto parapet, providing and laying / fixing TPO (Thermoplastic Polyolefin) waterproofing membrane STP LIMITED Shali TPO HG FB (Minimum 1.5 mm thick) , applied by using SHALI BOND TPO Adhesive @ 500 grms per sqmt, for fully bond Membrane to surface , as per manufacturer’s instructions. (iv) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per the technical guidelines laid by manufacturer, Company guarantees to be given by contractor after completion of water proofing work before payment.
Providing and carry out expansion joint treatment after proper surface preparation to remove loose mortars, dust, foreign particles from joints, fixing of tightly packed closed cell polyethylene based back up rod or filler board to ensure no gaps or voids exists, mask face edge of the joint using masking tape for neat finish, application of polyurethane or polysulphide sealant (width to depth : 2:1 ratio) and allow it cure for 2 days. Mixing of Two part Epoxy Adhesive using slow speed drill till get homogeneous mix, apply it to prepared joint 1-2mm thick with notched trowel or putty blade, tooled to a smooth finish and finally fixing of Flexible expansion joint (FPO Tape) membrane Dr. Fixit Seal Tape/ Hydro gap shield available in 1mm thickness and 150 mm wide exhibiting superior mechanical properties like, Elongation >500%, Tensile Strength >12N/mm2, Tear Strength >200N above joint followed by another layer of epoxy adhesives as complete as per manufacturer’s specification. Epoxy adhesive shall be applied on outer edges of tape. For joint over end laps, the overlaps surfaces must be clean, wiped and lapped with 100 mm overlap. After application the system should be allowed to cure for 7 days.
Removal of debris (Aggregates) obtained from demolition including loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed.
M&L for Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding , any type , any location/height( roof, parapet walls near pipes etc) and spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions after removing roots from wall slabs for preventing the regrowing and making good the disturbed portion using PCC 1:2:4 type B-0 with 12.5mm graded aggregate and plaster in CM 1:3 (Size of the disturbed portion 150X150X150mm) etc complete all as specified and as directed.
Cutting out V groove on cracks of walls and cleaning out, wetting, grouting with crack filler (Dr Fixit or equivalent) mixing with cement slurry, making good the surface by using CM 1:3 or PCC 1:2:4 type B-0 as required at site, as per manufactures instuctions, of any description and in any position, with necessary scaffoldings, as approved by Engr in charge
Demolition of Brickwork or stone / boulder / PCC block masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone-work and precast concrete articles etc complete all as specified and as directed.
Taking down cement plaster in wall/ceiling surfaces on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry of type C1 1:3:6 (using 20mm graded stone aggregate) with solid blocks exc 10cm in width and setting in cement mortar 1:4 etc complete all as specified and as directed.
M&L for half brickwork with sub class 'B' old size bricks, straight or curved on plan, to any radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on concrete surfaces as ceiling finished even and smooth (without using extra cement) complete all as specified and directed by Engr -in- charge.
M&L for plastering in external wall surfaces of 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) with water proofing compound complete all as specified and directed by Engr -in- charge.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats white wash etc. complete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of external walls and applying two coats cement base paint over a coat of cement primer complete all as specified and directed by the Engineer-in-Charge.
M & L for preparing old plastered or unplastered surfaces on walls/ceiling including cornices and applying one coat of cement based paint all as specified and directed by Engineer-in-Charge.
Supply only Liquid water proofing compound.
Taking up or down GI tubing of 15mm bore and connections etc complete all as specified and as directed.
Taking up or down GI/PPR tubing of 20mm bore and connections etc complete all as specified and as directed.
Taking up or down GI/PPR tubing of 25mm bore and connections etc complete all as specified and as directed.
S & F GI tubes of 15mm dia medium grade with all fittings and fixed complete to walls & ceiling or laid in floors etc complete all as specified and as directed.
S & F GI tubes of 20mm dia medium grade with all fittings and fixed complete to walls & ceiling or laid in floors etc complete all as specified and as directed.
S & F GI tubes of 25mm dia medium grade with all fittings and fixed complete to walls & ceiling or laid in floors etc complete all as specified and as directed.
S&F in repairs of Gun metal globe or gate valves/ Non returning Valve of 20mm dia with iron wheel head screwed both ends for iron pipe etc complete all as specified and directed by Engr -in- charge.
S&F in repairs of Ball valve 20mm dia high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum wt. 210gms) etc complete all as specified and directed by Engr -in- charge.
S & F in repairs of Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – I including dismantling of OHT of capacity 1000 ltrs complete all as specified and directed by Engr -in- charge.
Disconnecting existing tanks setting aside and hoisting of PVC water tank of capacity exc 500 & n exc 1000 ltrs including cleaning and removing all scale & dirt, etc from tanks, required reconnecting with necessary GI fittings as per site requirements and re- fixing in same position and also writing date of cleaning and due date of cleaning using enamel paint etc complete all as specified and as directed.
Demolition of cement concrete in ground floors (including tiles/floor finishes) and paving n exc 15 cm thickness (Below or above GL)
Dismantling floor, heath or wall tiling including cement sand mortar bedding and removing rubbish of the premises complete all as specified and directed by Engr -in- charge.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in Plinth protection etc even and smooth Without using extra cement as in floors all as specified and as directed.
S&F of Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc including Screed bed or bedding in layer of mortar 15 mm thick for laying floor finishes in cement plaster 1:4, complete all as specified and directed by Engr -in- charge. complete all as specified and as directed.
M&L for glazed ceramic tiles coloured of size 350 x 250 x 7 mm / 450 X 350 X 7 mm thick as on walls over jointing in neet slurry and pointing in coloured cement to match the inside of tiles including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engr -in- charge.
Dismantling of stone slabs and tiles of any description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar .
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 20 mm thick screed bed or bedding layer in cement mortar (1:6), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L for pre-cast reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), set in cement mortar 1:4 as in kitchen flat form and shelves in kitchen slabs, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, with plain faces etc complete all as specified and directed by Engr -in- charge.
M&L for MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia complete all as specified and as directed.
S&F in repairs of Vitreous China wash down water closet pan (Pedestal pattern), white including connection to drain and to flushing pipe, and plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and as directed.
S&F in repairs of Vitreous china wash basin, oval type white flat back, of any size excluding taps, waste, chain and plug and porcelain stopper but including brackets etc complete all as specified and directed by Engr -in- charge.
Supply only of Waste coupling of 32 mm chromium plated for glazed ware basins with long screwed shanks and fly-nuts etc complete all as specified and directed by Engr -in- charge.
S&F in repairs of Pillar taps Fancy type15 mm dia, cast copper alloy, Long nose , chromium plated fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and capston head, screwed for iron pipe of 15 mm bore etc complete all as specified and as directed.
S&F in repairs of Angle cock of 15 mm dia cast copper alloy with capstan head fancy type chromium plated etc complete all as specified and directed by Engr -in- charge.
S&F in repairs of PVC valveless, syphonic action type, flushing cistern, low level, 10 ltr capacity, white, with inlet, ball valve, float and handle including brackets and long flush band etc complete all as specified and directed by Engr -in- charge.
S&F in repairs of PVC connection 15mm size with brass CP nuts of length 600 mm complete all as specified and directed by Engr -in- charge.
S&F in repairs of brass chromium plated towel rack 600mm long "D" type fixed with suitable steel screw etc complete all as specified and directed by Engr -in- charge.
S&F in repairs Soap dish, stainless steel and fixed to wall complete all as specified and directed by Engr -in- charge.
S&F in repairs toilet paper holder ABS body chromium plated box type complete all as specified and directed by Engr -in- charge.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed by Engr -in- charge.
S&F in repairs of CP Bib taps two way in one 15 mm cast copper alloy fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engr -in- charge.(Make ; Jaguar or equivalent)
S&F in repairs of ABS body CP health faucet complete set including holder stand and one metre PVC pipe, 15 mm cast copper alloy screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engr -in- charge. Make : CERA Cat Part No 8030101.
S&F in repairs of stainless steel grating 100 mm dia without hole complete all as specified and directed by Engr -in- charge.
S&F in repairs of stainless steel grating 100 mm dia with hole complete all as specified and directed by Engr -in- charge.
S & F in repairs Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, all as Specified and Directed By Engr-In-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed by Engr -in- charge.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed by Engr -in- charge.
S&F PVC (SWR) bends any radius suitable for 110mm bore pipe complete all as specified and directed by Engr -in- charge.
S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed by Engr -in- charge.
S&F PVC (SWR) bends any radius suitable for 75mm bore pipe complete all as specified and directed by Engr -in- charge.
S&F in repairs of cast iron Nahani trap 75 mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) etc complete all as specified and directed by Engr -in- charge.
Taking down Chowkhats or frames with shutters (wihout taking off shutters) from the frame exc 1.5 sq. m but n exc 4 sq. m complete all as specified and as directed
Taking down Chowkhats or frames with shutters (wihout taking off shutters) from the frame n.exc 1.5 sq. m complete all as specified and as directed
S&F factory made solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement etc complete.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed.
S&F 150 mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F of butt hinges, medium weight, cold rolled mild steel of 100 mm long.
Cutting holes in brick work built in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3 depth of cutting exc half brick but n. exc one brick all as specified
M & L for MS flat for hold fast. Conforming to Fe-290 Gde E-165
S&F aluminium anodised various section powder coated as required for window/ ventilators etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement for shutter, sealant etc all as specified and as directed by Engr- in- charge. Note:-Aluminium window/ ventilators to be fixed with cadmium plated screw not less then 300 mm C to C & ceiling the joints between frames & granite stone with polysulphide sealant as per the manufactures instruction".
S&F Powder coated (Thickness not less than 50micron) Aluminium anodised Grill, aperture n exc 75 mm ,size 6mm x 4mm thick, including 1 mm thick channel fixed with steel screws complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified.
Dismantling ceiling boards ( fibre, pulp, insulation ,etc.), any thickness, including cover fillets
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. ®
M&L for false ceiling made out of 595x595x15 mm thick high density acoustic glass wool ceiling board / tiles. The visible surface is a matt black batch printed glass tissue cloth, also back of the tile is overed with glass tissue and the edges are natural complete all as specified and directed by Engr -in- charge.
S & F 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)
Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed.
Taking down Exhaust Fan dismantling blades and removing fan and refixing fan after completion of re-wiring and connecting up by cleaning / oiling etc including provision of 3core flexible round cable from ceiling rose or connector to fan all as directed.
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not less than 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :- (a) One light point controlled by one switch
(b) One Exhaust fan point controlled by one switch
Same as item above but with 2.5 Sqmm multistranded copper conductor wirewith 2.5 Sqmm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as directed for 15 A socket
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 16 Amp flush type universal complete all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S&F Switch Piano type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F LED light fitting 1x20 W 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L for Sub Main wiring with two runs of 1.5 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed. Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one unit.
S&F flush type light fittings of size 600x600mm suitable for 36W LED complete with inbuilt driver surface mounted/recessed type slim box type luminaries with CRCA housing white powder coated finish suitable to operate with 230 V AC, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm after removing old U/S rusted fittings complete all as specified and as directed.
S&F flush surface/recessed type light fittings round down lighter as per site requirement suitable for 18 W LED complete with inbuilt driver surface mounted slim box type luminaries with CRCA housing white powder coated and finish suitable to operate with 240 V AC, PF>0.9, 1800 lumen complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size after remove old U/S rusted fittings complete all as specified and as directed. .
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp after remove old U/S rusted fittings complete all as specified and as directed.
S J REDDY (BID ID -3352496)
Sri Sai Krishna Construction (BID ID -3352804)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .