| 1 | L1₹40.1 LAccepted-AOC NIVAS S J NIVAS 26 1798A CHALANCHERY ROAD MAMMAJIMUKU THEVARA KOCHI 682 013 | KOCHI | ERNAKULAM | KERALA | 682013 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹42.3 L+₹2.1 L (5.18%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest tenderer | |
| 3 | L3₹43.1 L+₹2.9 L (7.29%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L3 | Rejected-Finance Rejected being other than lowest tenderer | |
| 4 | L4₹47.0 L+₹6.8 L (17.0%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest tenderer | |
| 5 | L5₹47.6 L+₹7.5 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest tenderer |
Tender Value
₹49.0 L
Closing Date
30 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri SK Choudhary IDSE EE GE NW Kochi
GE (NW) Kochi Katari Bagh Naval Base Post Pin 682004
ADDN ALTN OF 02 ROOMS OF ASW SCHOOL FOR RED FORCE AND CERTAIN SANCTION WORKS IN THE AREA OF AGE BR II NW KOCHI AGE EM NW UNDER GE NW KOCHI
2021_MES_470837_1
GE (NW) Kochi / 8491 / E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Ge NW Kochi Kataribagh Naval Base Post Pin 682004
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW Kochi
Exempted
31 Oct 2021
28 Aug 2021
1 Oct 2021
29 Aug 2021
30 Sept 2021
17 Sept 2021
60 days
Amount
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in PVC concealed conduit rigid non metallic ( ISI marked ) fixed concealed on wall /roof except beam, column and RCC roof including chases cutting, modular white cover plate,flush metal box etc incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire compleate all as specified and directed Engr-in-charge for the following:- (a) One light point controlled by one switch
(b) One 5 pin 5 Amps Socket point controlled by one switch on same boardcompleate all as specified and directed Engr-in-charge.
(c) One 5 pin 5 Amps socket point controlled by one switch on independent board compleate all as specified and directed Engr-in-charge.
All as per item No 1 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board compleate all as specified and directed Engr-in-charge.
S & F modular switch 1 way 6 Amps,1 module compleate all as specified and directed Engr-in-charge
All as per item No 1 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure compleate all as specified and directed Engr-in-charge.
S&F fan regulator electronic step type, modular type, 120 W, 2 module compleate all as specified and directed Engr-in-charge.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB compleate all as specified and directed Engr-in-charge.
S&F Sheet metal enclosure TPN for DB's when MCCB's to be used 4 way with 200 amps bus bar double door IP 43 glazed door compleate all as specified and directed Engr-in-charge. Make L & T cat No DBTPE004GD /Havells/Legrand
S&F MCB 'B' Curve 63 Amp 4 pole, 415 Volts, Make L&T Cat Part No. BB40630B compleate all as specified and directed Engr-in-charge.
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts,Make Schneider Cat Part No. A9N1P06B to A9N1P32B compleate all as specified and directed Engr-in-charge.
S & F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body compleate all as specified and directed Engr-in-charge
S & F socket modular 6 Amps and 2/3 pin combined 2 module compleate all as specified and directed Engr-in-charge.
S & F Modular socket 6 A/16 A - 2/3 pin combined 2 module compleate all as specified and directed Engr-in-charge.
S & F switch 15 A One way SP modualr type compleate all as specified and directed Engr-in-charge.
S&F Tubelight fitting 1 x 20 w ,with T 8 LED tube with aluminium Extrusion heat sink for optimum performance with high luminous efficiency and batten pre wired suitable for use with LED tube with concealed accessories compleate all as specified and directed Engr-in-charge. Make:REGALBATTENT8UPTO1X22WSSBSWH & LED rod CRYSTAL1213T8DSTL20WLED865SGLASS/CG/WIPRO
S&F SPN sheet metal enclosure for DB 8 ways Double door compleate all as specified and directed Engr-in-charge.
S&F MCB 'B' Curve 40 Amp SPN ,240 Volts Make L&T Cat Part No. BB20400B compleate all as specified and directed Engr-in-charge.
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts,Make Schneider Cat Part No. A9N1P06B to A9N1P32B compleate all as specified and directed Engr-in-charge.
Supply & fix Wall mounted fans AC single phase 230/ 240 V of size 300 mm sweep complete all as specified Make Havells D'zire HS /CG/Usha .Note:- Old exhaust fans will be deposited in MES store yard compleate all as specified and directed Engr-in-charge.
M/L submain wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4 Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connceting with suitable size thimble compleate all as specified and directed Engr-in-charge. Note: two run of 4 sqmm size PVE cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
All as per Item No 21 here-in-before but 2 single core 10 sqmm compleate all as specified and directed Engr-in-charge.
Supply and fix LED flat panel with high brightness with glare free recessed 2 feet by 2 feet 36 Watt 4000k fitting including all connection compleate all as specified and directed Engr-in-charge. Make Philips Cat Part No. RC380BLED36S-6500G4L60W60PSUOD/ Havell/ Crompton.
S&F fan regulator electronic step type, modular type, 120 W, 2 module compleate all as specified and directed Engr-in-charge.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB compleate all as specified and directed Engr-in-charge.
S&F Sheet metal enclosure TPN for DB's when MCCB's to be used 4 way with 200 amps bus bar double door IP 43 glazed door compleate all as specified and directed Engr-in-charge. Make L & T cat No DBTPE004GD /Havells/Legrand
S&F MCB 'B' Curve 63 Amp 4 pole, 415 Volts, Make L&T Cat Part No. BB40630B compleate all as specified and directed Engr-in-charge.
S & F in repair 20 watt LED tube double side with batten ,universal type , 230V,50 Hz,wall surface ,roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.cat part no -,CRYSTAL1213T8DSTL20WLED865SGLASS(Tube) and REGALBATTENT8UPTO1X22WSSBSWH (Batten) of Havells or crompton,surya .
S & F in repair Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
S & F in repair MCB, DP, 32 Amps, 240 Volt, b curve, having breaking capacity 10 KA, complete all as specified.
Supply & fix ceiling fans complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete with 4 feet rod for extension all as specified.Make CG Cat Part Energion HS BLDC/Havells/Usha Note :-Old exhaust fans will be deposited in MES store yard
M/L submain wiring with 4 single core 16 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and two run of 10 Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connceting with suitable size thimble compleate all as specified and directed Engr-in-charge. Note: four run of 16 sqmm size PVE cable , two run of 10 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
M&L for earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.point 3 connected to earthing test point all as specified or indicated including testing on completion compleate all as specified and directed Engr-in-charge.
M&L for Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws compleate all as specified and directed Engr-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc compleate all as specified and directed Engr-in-charge.
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in stove enamelled Steel conduit fixed on wall /roof incl 1.6 mm thick MS sheet pressed terminal box (recessed) with 3 mm thick PVC laminated sheet top cover incl 1.5 Sqmm unsheathed FRLSH multistranded single core PVC insulated copper conductor earth continuity wire for one light/fan point controlled by one switch compleate all as specified and directed Engr-in-charge. Note - All acessories used in point wiring used flame redardant material like Steel conduit ,joints ,surface box Etc .
Ditto as Item No 36 here-in-before but for 5 Amp Point on independent board compleate all as specified and directed Engr-in-charge.
M&L for point wiring with 2.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in stove enamelled steel conduit fixed on wall/ roof incl 2.5 Sqmm unsheathed FRLSH multistranded single core PVC insulated copper conductor and earth continuity wire for one power point. Note :- All accessories used in point wiring shall be flame redardant material like Steel conduit, joints, surface box etc compleate all as specified and directed Engr-in-charge.
M&L point wiring with 1.5 Sqmm(FRLSH) insulated unsheathed multistranded single core copper conductor cable in non rigid PVC surface conduit/ PVC casing caping with all accessories incl MS sheet pressed terminal box (recessed) with alminated sheet cover for housing switches, sockets etc. or PVC moulded switch boards for accommodating switches/sockets etc. incl 1.5 Sqmm PVC insulated copper conductor earth continuity wire for the following compleate all as specified and directed Engr-in-charge. (a) One light point controlled by one switch
(b) One fan point controlled by one switch and regulator compleate all as specified and directed Engr-in-charge.
(c) One 5 Amp point on same board compleate all as specified and directed Engr-in-charge.
(d) One 5 Amp point on independent board compleate all as specified and directed Engr-in-charge.
M&L point wiring with 2.5 Sqmm(FRLSH) insulated unsheathed multistranded single core copper conductor cable in non rigid PVC surface conduit/ PVC casing caping with all accessories incl MS sheet pressed terminal box (recessed) with alminated sheet cover for housing switches, sockets etc. or PVC moulded switch boards for accommodating switches/sockets etc. incl 2.5 Sqmm PVC insulated copper conductor earth continuity wire for 15 Amps power point compleate all as specified and directed Engr-in-charge.
Supply and fix Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection compleate all as specified and directed Engr-in-charge. Make : Havells Cat Part No. REGALBATTENT8 UPTO 1X22W SSBSWH for Regal Batten & CRYSTAL 1213T8DSTL20W LED 865 GLASS for tube rod or philips/ Crompton
S&F building security light 1x36W with necessary bracket, clamps etc compleate all as specified and directed Engr-in-charge.Make Luker Cat Part No. LST36 or Philips/Crompton.
S&F Flame proof rotary switch with cable termination box in LM 6 single pole ON -OFF compleate all as specified and directed Engr-in-charge.make Sudhir Cat part no : -RI/OA/1010-2A
S&F switch socket and plug combined 2P + earth 16 Amps compleate all as specified and directed Engr-in-charge. Make : Sudhir Cat Part No. SS/OA/1010-1
S&F switch socket and plug combined 2P + earth 25 Amps compleate all as specified and directed Engr-in-charge. Make : Sudhir Cat Part No. SS/OA/1010-3
S&F Flame Proof exhaust fans AC single phase 230/240 V of size 305 mm sweep with louver compleate all as specified and directed Engr-in-charge. make Sudhir cat part no. EF/140
S&F CIMFR certified LED flame proof down lighter well glass in die cast aluminium housing with heat resistant toughened glass, IP-65 protection. Make : Crompton Cat Part No. FWL1315-40-CDL
S&F sheet metal enclosure TPN for DB's when MCB's to be used 8 way with 200 Amps bus bar double door including taking down old MCB DB with MCB's compleate all as specified and directed Engr-in-charge.
S&F MCCB 4 pole 100 Amp 415 V 36 KA adjustable type compleate all as specified and directed Engr-in-charge.
S&F MCB 'B' curve 32 Amp SPN, 240 Volts Make L&T Cat Part No. BB20630B compleate all as specified and directed Engr-in-charge.
Earhing complete with galvanized steel earth plate electrode 600X600X6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 M below ground level, connected to galvanized earth lead wire 4 mm , by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI medium grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc.50m and necessary testing complete all as shown on electrical plate no.3 of MES SSR Part I compleate all as specified and directed Engr-in-charge.
Taking down existing flame proof light of any type and size and removing to store yard for safe custody/ selling as scrap compleate all as specified and directed Engr-in-charge.
Supply, installation, testing and commissioning of split air conditioning unit 2.0 TR capacity (Inverter type) complete with cordless remote control, minimum 3 star labelled, manufacturer 5 year warranty on indoor and outdoor PCB, 10 year warranty on compressor, friendly refrigerant gas, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with all accessories varied speed including fixing the out door unit with suitable site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant with nitrile rubber insulation and control cable from indoor to outdoor upto a distance of 3.0 Mtrs as provided by OEM, Power cabling (Max 3.0 Mtrs from Isolator/ Enclosure) to unit, first charging of refrigerant gas including codeless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points compleate all as specified and directed Engr-in-charge. Make: Hitachi/Llyod/Daikin/carrier
Supply and fix capacity Voltage stabilizer, copper wounded suitable for 2TR inverter type split AC, automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, fixed on wall with necessary arrangements compleate all as specified and directed Engr-in-charge.
supply and fix double door sheet metals enclousures suitable for, 4 way vertical TPN DB with 63A MCCB as incomer 415 volts compleate all as specified and directed Engr-in-charge.
S&F 3 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA compleate all as specified and directed Engr-in-charge.
S&F single pole enclosure with a 2 pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt compleate all as specified and directed Engr-in-charge.
Supply and lay XLPE insulated heavy duty electric cables with aluminium conductor 1100volts grade cross sectional area 4 core 25sqmm clamped on walls/floors compleate all as specified and directed Engr-in-charge.
S&F MCB SP 6 to 32 Amp C curve, 240 Volt, 10 KA compleate all as specified and directed Engr-in-charge.
S/F 20mm OD CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors compleate all as specified and directed Engr-in-charge.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class "o" nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer. Note: 1) This item shall be measured for the quantity used at site for item No. 4 & 5 for beyond the length provided by OEM, along with unit. 2) One run of both 5/8" & 1/4" pipes alongwith insulation shall be measured as one length compleate all as specified and directed Engr-in-charge.
S & F in repair 4 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5Sqmm compleate all as specified and directed Engr-in-charge.
M & L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling compleate all as specified and directed Engr-in-charge.
S&F hangers 6 mm dia GI (upto 1200 mm length)adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.50 mm dia, 40 mm long compleate all as specified and directed Engr-in-charge.
S & F aluminium snap grid false ceiling frame work of angle 25x25x2 mm. Main TEE 38x25x1.5 mm and cross TEE 25x25x1.4 mm and size of grid 605x605 mm compleate all as specified and directed Engr-in-charge.
M&L for complete removal of existing paint and preparation of old surfaces (Ceiling) applying two coat of oil bound distemper compleate all as specified and directed Engr-in-charge.
Dismantling of floor or wall tiling including backing but not bedding and removal of derbis from the premises compleate all as specified and directed Engr-in-charge.
M&L for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 10mm thick screed bed of CM 1:4 compleate all as specified and directed Engr-in-charge.
S&F toughned glass door 12mm thick exc. 1sqm of each pane including all fittings like handle locks,pivots, floor spring etc compleate all as specified and directed Engr-in-charge.
S&F toughned plain glass 12mm thick 0.50sqm of each pane including all fittings like handle locks,pivots, floor spring compleate all as specified and directed Engr-in-charge.
S&F powder coated anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including jointing cleats for fixing etc compleate all as specified and directed Engr-in-charge.
S&F for Anodised powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc compleate all as specified and directed Engr-in-charge.
Taking down door/ windows chowkats exc 1.5 Sqm and n. exc. 4 Sqm each (without taking off shutters from the frame) compleate all as specified and directed Engr-in-charge.
M&L 10mm thick plaster in CM (1:6) on internal brick walls or concrete surfaces finished even and smooth without using extra cement compleate all as specified and directed Engr-in-charge.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brickwork or concrete surfaces compleate all as specified and directed Engr-in-charge.
Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles compleate all as specified and directed Engr-in-charge.
M&L for Precast cement concrete block masonry with solid blocks exc 10cm in width of type c1 1:3:6 using 16mm graded aggregate (as per IS 383 )and setting in C.M 1:6 compleate all as specified and directed Engr-in-charge.
M&L for preparation new plastered internal surfaces and applying two coats of Interior Emulsion (Asian Rayale interior enulsion) over a coat of primer and 3mm thick wall care putty compleate all as specified and directed Engr-in-charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
S&F Sheet glass ordinary quality exc 5.5 mm thick fixed with rubber beadings to aluminium frame work n exc 0.50 sqm in each pane compleate all as specified and directed Engr-in-charge.
M&L for preparation new plastered External surfaces for preparation of surface and applying two coats of weather proof (antifungal, Asian Ultima Protek) paint over a coat of suitable primer over 3mm thick wall care putty of three layer, complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
Demolition of cement concrete (reinforced) in chajjas, beams,roofs tec. and similar suspended work compleate all as specified and directed Engr-in-charge.
S & F Powder coated anodised aluminium 10mm dia hexagonal channel for grill fixed to aluminium frame with aluminium bidding complete all as specifed.Make : JINDAL or equivalent section from HINDALCO/INDALCO/MS AJIT IND PVT LTD
M&L for providing and fixing 9 mm thick PVC laminated Gypsum board false ceiling to metal frame work with screws as per manufacturer's instructions and compleate all as specified and directed Engr-in-charge. Note :- Metal frame work will be measured and paid separately.
M&L for providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over IInd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets or metal frame work and GI wire mesh paid separately) compleate all as specified and directed Engr-in-charge.
S&F GI frame work of grid size 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl GI wire mesh ccompleate all as specified and directed Engr-in-charge.
M&L for dark shade double charged vitrified ceramic tiles 10 mm thick(square/rectangular) polished, area of each tile exceeding 0.36 sqm, and not exceeding .42 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and laying in any design all as specified and as directed by Engr In Charge
All as per item No 89 here-in-befor but as in skirting compleate all as specified and directed Engr-in-charge.
M&L for 10 mm thick cement screed in cement mortar 1:3 on for fixing of wall tiles compleate all as specified and directed Engr-in-charge.
M&L for 10 mm thick screed bed or bedding layer of mortar in cement mortar 1:4 for laying floor finishes compleate all as specified and directed Engr-in-charge.
M&L for preparation and complete removal of existing treatment and applying two coats of Interior Emulsion (Asian Rayale interior enulsion) over a coat of primer and 3mm thick wall care putty compleate all as specified and directed Engr-in-charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
Demolition of cement concrete (un-reinforced) is ground floors and pavings n exc 15 cm thickness (below or above ground level) compleate all as specified and directed Engr-in-charge.
M&L for 18/19 mm thick pre-laminated particle board , interior grade, prelaminated both side docorative choice lamination , fixed with screws to aluminium frame work compleate all as specified and directed Engr-in-charge.
S&F Sheet glass ordinary quality 5.5 mm thick fixed with rubber beadings to aluminium frame work exc 0.50 sqm in each pane compleate all as specified and directed Engr-in-charge.
S&F hydraulic door closer designation No:03 universal type suitable for door shutters of 851 to 1000 mm in width aluminium extruded section body compleate all as specified and directed Engr-in-charge.
M&L 25 mm thick cement concrete type BO 1:2:4 using 12.5 mm graded stone aggregate as in below tiling compleate all as specified and directed Engr-in-charge.
SREENARAYANA ENTERPRISES
K.V.GEORGE AND COMPANY
M/s ANTONY THOMAS AND CO
THOMSONS CONSTRUCTIONS
Oriental Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .