Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹45.2 L
EMD Value
₹90,380
Closing Date
6 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GEAF/AMB-T-53/2025-26
2025_MES_734411_1
GE AF/AMB-T-53/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹90,380
Yes
9 Oct 2025
9 Oct 2025
8 Nov 2025
9 Oct 2025
6 Nov 2025
23 Oct 2025
10 Oct 2025 - 16 Oct 2025
Cleaning of manhole of any description & size and exceeding 1.5 M in depth including lifting up and removing sludge & accumulated solid/semi solid sludge and any other foreign material with mechanically & washing down with water for smooth functioning of sewage line all as directed, sludge obtained from cleaning shall be removed outside MD land complete all as specified and as directed.
All as per BOQ srl item No.275.00 here-in-above but depth exceeding 1.50M but not exceeding 3.00M, complete all as specified and as directed.
Taking down carefully any type of battens or conduit point wiring with or without conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing surface complete all as specified and directed.
S&F in repair switch piano, flush type, 05 / 06 Amps, single pole, one way, 240 volts complete all as specified & directed
Taking down light fitting any description complete all as specified and directed .
S&F in repair LED light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed
All as per BOQ srl item No. 85.00 here-in-above but capacity 150 Ltr, complete all as specified and directed
Detection of refrigerent leakage from water cooler cooling cap 40 litre, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified and directed
M & L for rewinding of desert cooler motor of same gauge of copper insulated winding including material complete all as specifed and directed
M&L for fixing in replacement of plywood 6mm thick commercial grade in window of desert cooler, including painting of ply after coat of primer complete all as specified and directed.
S&F in repair following spare parts for desert cooler complete all as specified and directed
Capacitor 4.0 mfd
Condensor fan blade, complete all as specified and directed
Condensor fan motor, complete all as specified and directed
M&L for preparation of surfaces of desert Cooler by scrapping old paint with sand paper, cleaning inner & outer surfaces of body and spray painting the inner surfaces and grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium paint, over one coat of zinc chrome primer complete all as specified and as directed
S&F in repair following (BOQ item No. 92.00 to 96.00) spare part for water cooler complete all as specified and directed
M&L for replacement of legs of same size of water cooler cap 80/150 litre complete all as specified and directed.
M & L for two coat of spary painting complete outside of water cooler of cap 40/80 or 60/120ltr with harmartone paint over a coat of red oxide including scraping the old painted surface , denting and minor patch works complete all as specified and directed.
Fan motor with blade and clamp 106 watt or nearest cap single phase, complete all as specified and directed
Attending complaint for Comprehensive maintainance and servicing of desert cooler of fan motor, water pump cleaning of PVC pipe testing including replacement of wood wool pad (set of three) etc for smooth functioning all as specified & directed.
M & L for rewinding of condensor fan motor of split type AC of capacity 1.5 / 2.0 TR with same gauge of copper insulated winding wire including insulating material complete all as specified and directed.
Tullu pump /Water pump, complete all as specified and directed
Attending complaint for Comprehensive maintainance and servicing of split type air conditoner of capacity 1.5/2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at site all as specified and directed. Note :- (i) Defective parts will be measured and paid separately .
(ii) Job includes servicing , rectification of defects as one job (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only.
S & F in repair replacement new sealed Rotary compressor of capacity 19000 BTU/Hour ( Nearest capacity ) , single phase 230 v , 50 Hz split type conditioner / window type air conditioner complete all as specified and directed. Note - Gas charging will be measured and paid separetly .
Run capacitor 45/36 MFD
M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of slpit type AC / window AC capacity 1.5 TR complete at site all as specified and directed. Note:- (i) Leak detection with Nitrogen is deemed to be included in quoted rate. (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates.
Cordless remote with battery
Condensor motor with Blade
Condenser fan blades for spilt type AC units of capacity 1.5T/2T
Indoor swing motor of capacity 1.5T/2T
Wiring kit for split type AC units 1.5/2TR
Indoor Blower wheel
Suction and discharge valve set for type split AC 1.5/2T
Refrigerant Gas R-22
Refrigerant Gas R-134A
Refrigerant Gas R-32
Refrigerant Gas R-410
M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of slpit type AC / window AC capacity 2 TR complete at site all as specified and directed. Note:- (i) Leak detection with Nitrogen is deemed to be included in the quoted rate (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates.
S & F in repair replacement hermatically sealed Rotary compressor of capacity 25000 BTU/Hour ( for 2 Ton AC) single phase 230 V , 50 Hz split type air conditioner all as specified and directed. Note - Gas charging will be measured and paid separately .
S&F metal clad switch socket outlet with single pole and neutral enclosure with two pin and earth plug socket with 01No. single pole MCB 20Amps 10kA complete all as specified and as directed
Supply, installing of condenser coils of split AC capacity 1.5 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately complete all as specified and directed
Supply, installing of condenser coils of split AC capacity 2 TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately complete all as specified and directed
PCB card
S&F in repair spare part for split type AC complete for any make / Model of capaity 1.5 / 2 TR complete all as specified and directed
M & L for taking down unserviceable burnt Indoor blower fan motor of split AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning complete all as specified and directed
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil for Erection of pole/laying cables etc., and getting out complete including forming bottom surfaces to required levels/slopes etc complete all as specified and as directed
Material and labour for copper earthing strip 20mm x3mm laid in trenches / fixed on wall for inter connecting /extension in earthing including excavation and earth work complete all as specified and directed
Supply, installing and testing in repair outdoor unit comprising of copper Condensor coil , motor with blade ,compressor rotary type of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply, installing and testing in repair Indoor unit of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit deposited to MES AC section yard complete all as specified and as directed. Note: charging of refrigerant shall be measured & paid separately
Supply and laying well burnt fire Bricks of size 230x115x75 mm, locally available best quality (sub class "B" bricks) laid in trenches with 230mm side perpendicular to U/G cable for cable protection complete all as specified and directed.
Taking down of split type air conditioner from existing location and installation after repair in same / other location including gas charging , testing , commisioning and comprising of following. (i)Replacement of refrigerant tubing with insulating sleeve upto 6RM with brass flair nut. (ii) Drain pipe upto 6RM (iii) Air conditioner bracket-1 set (iv) interconnecting cable from indoor unit to outdoor unit
M&L for GI earthing strip 32x6mm laid in trenches / fixed on wall with saddles for inter connecting /extension in earthing including excavation and earth work complete all as specified and directed
Returning, filling-in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
M&L for earthing with copper earth plate electrode 600 x 600 x3.15 mm thick buried directly in ground earth pit not less than 3.75 m below normal GL with the top edge of the plate not less then 2.50 m below the normal GL connected to copper strip 20x3mm protected by 50mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded stone aggregate, coping with (1:3:6) type CI using 20mm graded stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt, magnesium sulphate in layer 150mm thick in all side of plate and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing accessories and dispose off from site deppsited to MES store yard complete all as specified and directed. NOTE: (i) Main earthing lead and protection GI pipe from earth electrode to test point up to 7.5 m is to be provided and the cost for the same shall deemed to be included in the above quoted rate. earthing lead beyond 7.5 m shall be measured and paid for separately under respective item of Sch Part III Section I. (ii) if desired resistance is not found then entire earthing shall be re-done by Contractor at no extra cost to Govt.
Supply Installation Testing and Commissioning in replacement a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x50x6mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriter laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter - an international standard for Earth Enhancement Compound by NABL accredit Lab. Note : (i) The rate for interconnection of tripod earth with Copper strip of size 20x3 mm and poly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. The Earth result should be less than 1 ohm and the result will be checkedin presence of user rep & MES Rep. if desired earthing is not found then entire earthing shall be re-done by Contractor at no extra cost to Govt.
Removing excavated material(soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment purpose only
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 10 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 16 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 4.0 core X 25Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 50Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 120 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
M&L for boring/auguring suitable hole & insertion of 80 mm dia GI pipe including supply and inserting pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed. Notes:- Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted
M & L for PCC,1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation, base of pole and in embedding blocks for stays complete all as specified and directed.
M&L for PCC,1:3:6 type C2 (using 40mm graded mechanically crushed stone aggregate)as in coping/collar of electric poles including use of necessary form work and concrete finished even and smooth without using extra cement complete all as specified and directed.
S&F as in repair MCCBs 415V,25 KA, 4 Pole 100 Amp with Adjustable thermal magnetic release as complete all as specified and directed
M&L for crimping type heavy duty copper lugs/ferrule suitable for cable cross sectional area 16/25 Sqmm complete all as specified and directed.M&L for crimping type heavy duty copper lugs/ferrule
潬杮眠瑩污湩畳慬楴湯洠瑡牥慩…潭潴楷摮湩牰癯摩摥眠瑩桴牥慭睳瑩档獥映牯瀠潲整瑣潩条楡獮⁴硥散獳癩整灭牥瑡牵楲敳挠浯汰瑥污獡猠数楣楦摥愠摮愠楤敲瑣摥郞潐慴汢慷整档浥捩污愠慮祬楳整瑳湩景眠瑡牥琠敢挠湯畤瑣摥戠⁹慬潢慲潴楲獥愠瑵潨楳摥戠⁹䅎䱂偐䉃☠䌠䍐⹂吠敨琠獥⁴楷汬愠慮祬敳瀠ⱈ潣潬牵摏畯Ⱳ吠獡整畔扲摩瑩ⱹ琠瑯污䠠牡湤獥ⱳ吠瑯污䄠歬污湩瑩ⱹ䤠潲Ɱ挠汨牯摩ⱥ删獥摩慵牆敥䌠汨牯湩ⱥ䘠畬潲摩ⱥ吠瑯污䐠獩潳癬摥匠汯摩畓灬慨整楎牴瑡ⱥ吠瑯污䌠汯晩牯Ɑ䔠挮汯瑥湩汣摵湩潣汬捥楴杮漠慷整牦浯琠敨猠畯捲湩愠猠慰楣楬敳汧獡潢瑴敬甠敳潦桴獩瀠牵潰敳湡潣汬捥楴杮琠敨爠灥牯獴映潲桴慌Ɫ挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整††ʬȈ䴀䰦映牯愠瑴湥楤杮漠慷整畳灰祬挠浯汰楡瑮潦湡⁹敬歡条 汢捯慫敧椠䥇瀠灩楬敮景猠穩〲浭⼠㈠洵⽭〴浭⼠〵浭戠牯慴楫杮甠⁰敳癲捩慥汢 湵敳癲捩慥汢䥇眠瑡牥瀠灩楬敮污楦瑴湩獧是硩畴敲牦浯琠敲据湩汣摵湩畳灰祬愠摮氠祡湩䥇琠扵湩〲浭⼠㈠洵⽭〵浭戠牯灵琠‱瑭敬杮桴⠠慭⥸椠据畬楤杮渠捥獥獳牡⁹畣瑴湩Ⱨ琠牨慥楤杮猠極慴汢潦〲浭⼠㈠洵⽭〵浭†湩汣摵湩敮散獳牡⁹硥慣慶楴湯愠摮攠牡桴眠牯灵琠‱畃潴爠灥楡桴敬歡条 汣慥楲杮琠敨戠潬正条湩琠敨瀠灩楬敮愠摮琠獥楴杮漠潣灭敬楴湯挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整上呏⁅›硅慣慶楴湯洠牯桴湡ㄠ䌠浵愠摮䜠⁉楦瑴湩獧猠慨汬戠敭獡牵摥愠摮瀠楡敳慰慲整祬甠摮牥爠汥癥湥⁴瑩浥漠桴獩猠档摥汵づਂ㜀܂츀āS&F LED flood light 250 watt 230 V AC Lumen effeciency=≥ 115 Im/W, colour Temp 5500 - 6500 Kwith inbuilt secondary Lens outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp, thermal management in multiple optics complete with IP 65/66 protection with suitable size bracket and clamps,nut ,bolts washer etc including taking down existing unserviceable lights any type complete all as specified and as directed.Ǎ匁☀䘀 䰀䔀䐀 昀氀漀漀搀 氀椀最栀琀 ㌀ 眀愀琀琀 ㈀㌀ 嘀 䄀䌀 䰀甀洀攀渀 攀昀昀攀挀椀攀渀挀礀㴀攀•㔀 䤀洀⼀圀Ⰰ 挀漀氀漀甀爀 吀攀洀瀀 㔀㔀 ⴀ㘀㔀 䬀 眀椀琀栀 椀渀戀甀椀氀琀 猀攀挀漀渀搀愀爀礀 䰀攀渀猀 漀甀琀搀漀漀爀 琀礀瀀攀 眀椀琀栀 栀椀最栀 瀀爀攀猀猀甀爀攀 搀椀攀 挀愀猀琀 愀氀甀洀椀渀甀洀 栀漀甀猀椀渀最 愀渀搀 栀攀愀琀 爀攀猀椀猀琀愀渀琀 挀漀洀瀀氀攀琀攀 眀椀琀栀 搀爀椀瘀攀爀Ⰰ 氀愀洀瀀Ⰰ 琀栀攀爀洀愀氀 洀愀渀愀最攀洀攀渀琀 椀渀 洀甀氀琀椀瀀氀攀 漀瀀琀椀挀猀 挀漀洀瀀氀攀琀攀 眀椀琀栀 䤀倀 㘀㔀⼀㘀㘀 瀀爀漀琀攀挀琀椀漀渀 眀椀琀栀 猀甀椀琀愀戀氀攀 猀椀稀攀 戀爀愀挀欀攀琀 愀渀搀 挀氀愀洀瀀猀Ⰰ渀甀琀 Ⰰ戀漀氀琀猀 眀愀猀栀攀爀 攀琀挀 椀渀挀氀甀搀椀渀最 琀愀欀椀渀最 搀漀眀渀 攀砀椀猀琀椀渀最 甀渀猀攀爀瘀椀挀攀愀戀氀攀 氀椀最栀琀猀 愀渀礀 琀礀瀀攀 挀漀洀瀀氀攀琀攀 愀氀氀 愀猀 猀瀀攀挀椀昀椀攀搀 愀渀搀 愀猀 搀椀爀攀挀琀攀搀⸀餀♍⁌潦牂捩睫牯楷桴†畳汣獡⁂牢捩獫瑳慲杩瑨漠畣癲摥漠汰湡攠捸敥楤杮㘠敭湡爠摡畩ⱳ戠極瑬椠䵃⠠㨱⤶挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整敄潭楬楴湯†景挠浥湥⁴潣据敲整⠠湵爭楥普牯散⥤椠牧畯摮映潬牯愠摮瀠癡湩潮⁴硥散摥湩㔱浣戠汥睯漠扡癯牧畯摮氠癥汥愠挠浯汰瑥污獡猠数楣楦摥愠摮搠獩潰楳杮漠晦爠扵楢桳漠瑵楳敤䴠⁄慬摮挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整礠♍⁌潦〱‰浭琠楨正瀠慬湩挠浥湥⁴潣据敲整ㄠ㨠㈠㨠㐠琠灹㉂⠠獵湩〲洠牧摡摥†敭档湡捩污祬挠畲桳摥猠潴敮愠杧敲慧整 獡椠慨摲猠慴摮湩†慬摩椠慰敮獬椠据畬楤杮渠捥獥慳祲映牯潷歲映湩獩敨戠⁹灳歩潲汬湩猠牵慦散景挠湯牣瑥湡潆浲湩潣獮牴捵楴湯樠楯瑮〳洠敤灥愠摮ㄠ‰浭眠摩楦汬摥眠瑩敳污湩潣灭畯摮朠慲敤✠⁁†潣灭敬整愠汬愠灳捥晩敩湡獡搠物捥整ᅤ♍⁌潦桃煥敵敲散敭瑮挠湯牣瑥挠汯畯敲潣浭牥楣污吠汩獥㌠䌰⁍⁸〳䵃砠㈠‰潴㈠洲桴捩景眠瑩牧祥挠浥湥⁴湡瀠杩敭瑮†敳⁴樠楯瑮摥愠摮瀠楯瑮摥椠敮瑡挠浥湥⁴汳牵祲椠汦潯獲愠摮挠瑵愠摮瀠汯獩敨慬摩愠摮漠敶㔱浭匠牣敥湩䌠⁍㨱‶污獡猠数楣楦摥愠摮愠楤敲瑣摥渮♍⁌潦慓摮映汩楬杮甠摮牥映潬牯椠据畬楤杮眠瑡牥湩湡潣獮汯摩瑡潩潣灭敬整愠汬愠灳捥晩敩獡搠物捥整ú䐀浥汯瑩潩景挠浥湥⁴潣据敲整⠠湵爭楥普牯散⥤椠湡⁹敤捳楲瑰潩…湩愠祮瀠獯瑩潩潮⁴瑯敨睲獩灳捥晩捩污祬瀠潲楶敤潦獡椠潣楰杮敢据楨杮敢汢捯敫扲瑥湡楤灳獯湩景畲扢獩畯獴摩䑍氠湡潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥♍⁌潦牐癯摩湩Ⱨ挠浥湥⁴潣据敲整椠㨱㨲‴祴数䈠‱用楳杮㈠洰牧摡摥洠捥慨楮慣汬⁹牣獵敨瑳湯条牧来瑡⥥爠潯敫扲Ⱐ䤠瑮牥潬正湩楔敬倯癡牥䈠潬正†牯†洠摵†猠潴獰潲湵敤†牯挠慨晭牥摥漠摥敧挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整썤♍⁌潦牐捥獡⁴䍒⁃㨱㨲‴祴数䈠‱用楳杮㈠洰牧摡摥洠捥慨楮慣汬⁹牣獵敨瑳湯条牧来瑡⥥愠湩挠癯牥猠慬景搠慲湩畣癬牥⁴湡桴楬敫猠瑥椠䵃ㄠ㐺挠浯汰瑥污獡猠数楣楦摥愠摮愠楤敲瑣摥ꌮ䴠䰦映牯䄠灰祬湩睴潣瑡景挠浥湥⁴慢敳瀠楡瑮漠敶愠歬污湩牰浩牥漠敮⁷慷汬猠牵慦散椠据畬楤杮瀠敲慰慲楴湯漠畳晲捡ⱥ挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整煤硅慣慶楴湯椠潳瑦猠楯潦潰瑳栠汯獥⠠牯猠浩汩牡栠汯獥 慥档渠瑯攠捸敥楤杮†⸰‵畣Ɑ朠瑥楴杮漠瑵敲畴湲湩Ⱨ映汩楬杮椠湡慲浭湩慥瑲牯戠潲敫畲扢敬洠硩摥眠瑩慥瑲牡畯摮湩氠祡牥潮⁴硥散摥湩㔲浣慷整楲杮湡敲潭楶杮猠牵汰獵猠楯潴愠搠獩慴据潮⁴硥散摥湩〵湡慭楫杮朠潯畳晲捡ⱥ眠牯湩愠祮琠灹景猠楯ⱬ挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整ᙤ敄潭楬楴湯愠摮戠敲歡湩灵ㄠ〵洠楤牤楡楰数ⱳ椠据畬楤杮戠摥挠湯牣瑥潦慓瑬朠慬敺慷敲偕䍖䍁牯删楥普牯散散敭瑮挠湯牣瑥楰数ⱳ猠瑥椠散敭瑮洠牯慴湩汣攠捸癡瑡潩景攠牡桴眠牯湡敲潭楶杮琠敨爠扵楢桳漠瑵楳敤䴠⁄慬摮挠浯汰瑥污獡猠数楣楦摥愠摮愠楤敲瑣摥ਮi匀䘦倠䍖⠠坓⥒戠湥獤愠祮爠摡畩ㄱ‰浭戠牯潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅楧敮牥椭档牡敧ƟȈ ♍⁌潦㔱浭琠楨正爠湥敤楲杮漠牢捩牯挠湯牣瑥畳晲捡景洠湡潨敬ⱳ搠慲湩愠摮猠灥楴慴歮猯慯慫敧眠汥椠散敭瑮洠牯慴㨱‴湡楦楮桳湩桴畳晲捡楷桴甠楳杮眠瑡牥瀠潲景湩潣灭畯摮†癥湥愠摮猠潭瑯楷桴畯⁴獵湩硥牴散敭瑮愠汬愠灳捥晩敩湡獡搠物捥整††††††††††††††††††††††††††††††††††††††††上瑯㩥圠瑡牥瀠潲景湩潣灭畯摮猠慨汬戠敭獡牵摥愠摮瀠楡敳数慲整祬Ŝ ŢV匀灵汰⁹湯祬眠瑡牥瀠潲景湩潣灭畯摮†楬畱摩挠浯汰瑥污獡猠数楣楦摥愠摮愠楤敲瑣摥键ࠁ♍⁌潦牰灥牡瑡潩景漠摬漠牰癥潩獵祬琠敲瑡摥猠牵慦散景删䍃⼠匠潴敮⼠䌠湯牣瑥 牢捩慷汬⽳䄠扳獥潴敃敭瑮匠敨瑥漠汰獡整敲畳晲捡獥愠摮愠灰祬湩湯潣瑡漠攠瑸牥潩捡祲楬浥汵楳湯瀠楡瑮椠慣潭晵慬楧杮瀠瑡整湲漠湡⁹桳灡湡愠祮猠穩潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅楧敮牥椭档牡敧ਠ潎整›慓灭敬漠慣潭晵慬敧瀠瑡整湲琠敢愠灰潲敶獡瀠牥琠敨甠敳敲畱物浥湥⁴戠⁹䕇†㰠ਁ䈀܁♍⁌潦敄楳瑬湩湡汣慥楮杮漠汢捯敫潣敶敲湡畣癬牥⁴瑥祢爠浥癯污漠畭Ɽ猠楯ⱬ愠杧敲慧整愠摮漠桴牥猠浩汩牡眠獡整洠瑡牥慩潦浳潯桴映潬楷杮是湵瑣潩楮杮†景猠潴浲眠瑡牥愠摮搠獩潰楳杮漠晦爠扵楢桳漠瑵楳敤䴠⁄慬摮挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整į䴀…⁌潦敤慷整楲杮漠潳歡眠汥潣灭敬整祬漠楳敺渠瑯攠捸敥楤杮㌠瑭楤湡潮整攠捸敥楤杮㘠洠牴搠灥桴戠⁹敭湡景瀠浵楰杮漠瑵漠慷整潴洠癯扡敬洠捥慨楮慣牴湡灳牯⁴楬敫琠湡敫愨瑴捡敨潴琠慲瑣牯琯畲正 湡楤灳獯湩景桴慷整畯⁴楳敤漠敤敦据慬摮挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整ͷ䌀敬湡湩景琠敨甠摮牥朠潲湵敳敷楬敮甠瑰㔱洰楤景愠祮琠灹污湩眠牯楫杮爯湵楮杮挠湯楤楴湯湩潶癬湩敲潭慶景戠潬正条景愠祮欠湩楬敮祢洠慥獮漠敭档湡捩污爠摯楤杮眠瑩楶牢瑡潩獮搯楲汬湩潣据灥⁴牴汯敬⁹潭湵整潭潴楲敺敳敷汣慥楮杮洠捡楨敮椠据畬楤杮搠獥畬楤杮敤捳污湩湡敤档歯湩桷牥敥敶敲楱敲Ɽ映畬桳湩桴湥楴敲猠牴瑥档眠瑩潣扭湩摥栠杩牰獥畳敲眠瑡牥樠瑥楴杮挠浵猠捵楴湯⠠慶畣⥭琠灹慭档湩畳瑩扡祬洠畯瑮摥漠䍈⁖慨楶杮映捡汩瑩敩景栠摹慲汵捩愠灰楬慣楴湯桴潲杵瑨栠杩瑨瀠敲獳牵桴牥潭瀠慬瑳捩映扩牬戠獡摥眠瑡牥樠瑥楴杮栠獯湡桴潲杵潣楮慣⽬潲湵桳灡潮空敬瀠灩獥慭楫杮琠敨猠牴瑥档挠敬湡愠摮映畯据楴慮湡敲潭慶⽬敤潰楳楴湯漠汳摵敧椠据畬楳
e of solids if any & sludge water to a distance not exceeding 500 mtrs beyond the periphery of defence land and covering the entire sludge and solids with local sand/earth all as directed. M&L for preparation of old or previously treated surfaces of RCC / Stone / Concrete / brick walls/ Asbestos Cement Sheet or plastered surfaces and applying two coat of exterior acrylic emulsion paint in camouflaging pattern including 2mm thick putty of any shape and any size complete all as specified and directed by Engineer-in-charge, Note: Sample of camouflage pattern to be approved as per the user requirement by GE U [8Supply, Installatin, testing & commisiong of loop driven addressable sounder/Hooter with strobe in built as in repair. The addressable soundre/Hooter with strobe shall form part of loop devices such that, no addtional seprate wiring is required. The sounder/ Hooter shall have audible range of 93 DB when heared at distance of 1.00mtr. the shounder/Hooter shall be suitable for wall/ ceiling mounting and shall operate on =24 volts DC complete all as specified and directed by Engr-In-Charge. Make: EST or compatible with existing in other i.e siemens/Agni protection.äSupply, Installation, testing & commisioning of Main fire Alarm panel PPSM card (power supply Unit) as in repair complete all as specified and directed. Make: EST or compatible with existing in other i.e siemens/Agni protection.ÏSupply, installation, testing & commisioning surge protector as in repair complete all as specifeid and directed by Engr-in-Charge. Make: EST or compatible with existing in other i.e siemens/Agni protection.«Supply, Installation, testing & commisioning of External power supply unit for hooter operating 5Amp as in repair complete all as specified and directed by Engr-in-Charge.±Providing M&L for SDU Backup creation and Re-programming including All devices cleaning and complete data base creation complete all as specified and directed by engr-in-charge.LOTJM&L for rewinding of following fans with same gauge of super enameled copper wire complete,varnishing ,baking , connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screws etc testing,complete all as specified and directed. NOTE: (a) Spare parts like bearing,capacitor,bushes if required will be measured and paid separately. (b) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts (c) Cost of removing fans from site to AGE E/M store and AGE E/M store ro site shall be deemed to be included in the quoted rate.Á Æ©Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ complete all as specified and directed Note- (a) Detection and rectification of leakage of inner tank of geyser by brazing/welding/soldring. (b) Painting of geyser included in quoted rate. (c)wornout parts shall be measured as separately.â èDetection of refrigerent leakage from water cooler cooling cap 150 litre, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified and directedíS & F in repair replecement new sealed compressor for water cooling cap 40 litre (or nearest cap) single phase 230 volt, 50 HZ water complete complee all as specified and directed. Note : gas charging will be measured & paid separatelyµ ½ÏM&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI wire 4
S & F in replacement of star delta starter suitable for 30 to 40 HP submersible pump with proper electrical connection including additional wiring etc complete all as specified and directed.
d by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded stone aggregate, coping with (1:3:6) type CI using 20mm graded stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing accessories and dispose off from site deppsited to MES store yard complete all as specified and directed. NOTE: (i) Main earthing lead and protection GI pipe from earth electrode to test point up to 7.5 m is to be provided and the cost for the same shall deemed to be included in the above quoted rate. earthing lead beyond 7.5 m shall be measured and paid for separately under respective item. (ii) if desired earthing resistance is not found then entire earthing shall be re-done by Contractor at no extra cost to goverment, 6M&L for crimping type heavy duty copper lugs/ferrule suitable for cable cross sectional area 50/70 Sqmm complete all as specified and directed.dTaking UP/down the existing cables any description from trenches /poles/ walls etc complete all as specified and directed. Note :- Earth work shall be measured and paid separately.+ 3S&F in replacement of Contactor 3 pole 415 volts 200 Amps ML -12 (control voltage 230/415 as per existing model.) all as specified and directed.ÃCleaning of SWT capacity of 50000 Gln water thoroughly by removing mud grits etc complete all specified and directed. Notes : rates quoted shall deemed included for followng :- (i) Cleaning inner surfaces of tanks complete with scraping wth steel wire bruses, pressure wash, removing mud, sludge collected inside the tank manualy, removal of mud to a distance not exceeding 50mtrs. (ii) Washing with clean water and bieaching powder or with high strength calcium chloride mxture thoroughly internally removing left out sludge if any to a distance not exceeding 50 mtrs including writing capacity of SWT, cleaning date, due dated for cleaning with black synthetic enamel paint with existing pattern.~ ÃCleaning of OHT capacity of 75000 Gln water thoroughly by removing mud grits etc complete all specified and directed. Notes : rates quoted shall deemed included for followng :- (i) Cleaning inner surtaces of tanks complete with scraping wth steel wire bruses, pressure wash, removing mud, sludge collected inside the tank manualy, removal of mud to a distance not exceeding 50mtrs. (ii) Washing with clean water and bieaching powder or with high strength calcium chloride mxture thoroughly internally removing left out sludge if any to a distance not exceeding 50 mtrs including writing capacity of OHT, cleaning date, due dated for cleaning with black synthetic enamel paint with existing pattern.~ µM&L for rough cast plaster incl 15 mm thick CM 1:3 on brickwork or concrete surface complete all as specified in SSR Part-I clause 14.22 complete all as specified and directed. Note: Rough cast finish to be as described below: After applying the under coat of cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg( which is generally of size between 6 to 12 mm depending on the texture required) mixed with course sand and cement in the ratio 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered. uSupply, Installation, testing & commisioning of intelligent addressable multisensor type (co
S&F as in repair MCCBs 415V,25 KA, 4 Pole 125 Amp with Adjustable thermal magnetic release complete all as specified and directed
S&F as in repair MCCBs 415V,25 KA, 4 Pole 200 Amp with Adjustable thermal magnetic release complete all as specified and directed
S&F in repairs power capacitor for APFC panel, power quality,heavy duty 25kVAR, 440V, 50Hz, double dielectric capacitor, with rated current 32.8A, required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed.
S&F in replacement aviation obstruction light with all connected accessories to be fixed on GI Pipe 40/50mm bore light grade as per site requirement of existing make and model to be fixed on OHR or any other place complete all as specified and directed
Comprehensive maintenance & servicing /cleaning of Automatic power factor panel,replacement of worn out part detection of faulty component /wiring & testing complete all as specified and directed . Note: Spare parts shall be measured and paid separately as supply only
M&L for painting of PCC/steel poles 9/11 m long alongwith road/ peri meter upto 1.5 m height from pedestal, with two coats of synthetic enamel paint in 30 cm height 5 block of each airforce pattern incl painting of pole, coping with black paint and writing pole Numbers with white paint on black circular base incl. marking of HT/LT with Painting of pole cross arms bracket with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed by EIC .
M&L for painting of LT panels of any size and capacity, with two coats of synthetic enamel paint with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed by EIC .
Supply only following spare parts of DG set of kirloskar/Cummins DG set complete all as specified and directed.
V belt
Taking down old unservicable any type street lights and refixing after repair of street light /security lights including cleaning of perplex cover where ever required and tightening of loose connection on the pole, Complete all as specified and directed.
Battery Terminal
Battery 90AH, maintenance free Genplus 12volts complete all as specified and directed.
M & L for FRP looping box with hinged cover weather proof with locking arrangement and appropriate size of aluminium bus bar of capacity 100 amps for single phase 230 V, 50 Hz electric supply mounted on PVC insulaters and fixed to pole by means of MS clamps, nuts boltss and washers including cables connection including one MCB SP 6 amps including taking down existing looping box complete all as specified and directed.
Removing/taking out non clog type submersible sewage pumping set capacity 3 to 5 HP from sewage well after dewatering of sewage water and Rewinding of motor 3 to5HP of Non clog type submersible pumping set with suitable size of copper winding wire incl all insulation material & motor winding with pump dismantling the same for assessing & carrying out the repair/service as involved in subsequent items making good in running condition by repair/replacement of all unserviceable spare parts etc re-assembling, lowering the same into the well and making necessary connections, testing complete all as specified and directed.
S&F 1100 volts grade heavy duty two single core cables PVC insulated stranded aluminium conductor of size 6 sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire dispose from site complete all as specified and directed.
Taking up/down steel tubing GI pipel
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 15mm bore medium grade ISI marked with all fittings complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 20 mm bore medium grade ISI marked with all fittings complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches / fixing on wall / roof steel water tubing galvanised 25 mm bore medium grade ISI marked with all fittings complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches / fixing on wall steel water tubing galvanised 40 mm bore medium grade ISI marked with all fittings complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches / fixing on wall steel water tubing galvanised 50 mm bore medium grade ISI marked with all fittings complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing Gun metal Gate valve 50 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 40 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 25 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 20 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing and testing Gun metal Gate valve 15 mm dia screwed body ends and cast iron hand wheel conforming to IS :778 –1984 and ISI marked complete all as specified and directed.
Supply, fixing, testing and commissioning Double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS : including rubber gasket, nuts, bolts and washers complete all as specified and directed.
ines/connection from trenches/wall /roof incl connected fittings/accessories and cleaning for refixing or removal to store for 20mm bore complete all as specified and directed.
Taking up/down steel tubing GI pipelines/connection from trenches/wall / roof incl connected fittings/accessories and cleaning for refixing or removal to store for 15mm bore complete all as specified and directed.
Opening of submersible motor for rewinding with PVC coated copper winding wire as per existing gauge insulation material,after stripping of existing worn out winding, M&L for sealing kit, O- ring, Gasket, water drain plug, sand guard, cable packing ring, cable gland ring, upper/lower bearing, adopter piece, motor key, upper lower flange, neck ring, suction case, Hex bolt, Circlip washer, Motor coupling, thurst plate,motor bush etc complete, reassembling with pump set of the capacity upto 35 HP complete all as specified and as directed
M&L for Cleaning, Desludging/ dewatering of valve pit chamber, Bailing
Taking up/down steel tubing GI pipelines/connection from trenches /wall incl connected fittings/accessories and cleaning for refixing or removal to store for 40mm or 50mm bore complete all as specified and directed.
M&L for run lead joints of spigot and socket pipes and fittings for DI/CI pipe 100 mm bore size of pipe including provision of bolts, washers and white lead or mineral oil complete all as specified. Note;- Earth work will be measured and paid separately.
M & L for lifting of column pipe, flanged 100mm bore with submersible cable from bore hole of tube well, pump set of any capacity and lowering after repair in borewell complete all as specified and directed by Engr-in-Charge. Note: (i) Lifting & lowering of pump set upto 120 mtrs deep will be deemed to be included in unit rate. (ii) Lifting & lowering of pump set to be completed out within 24 hrs from intimation. (iv) Rubber gasket, nuts & bolts for replacement deemed to be included in unit rate.
M&L for taking down high pressure SV/ MV/ MH /FTL/LED street light fitting and Flood Light fittings of any wattage / any height of pole/ walls/ watch tower any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified. Note: - LED Drivers, Surge protection and cable shall be measured separately under relevant items of schedule
S&F in replacement 5 KV SPD for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures up to rated power of 120W /90W /70W for fixing in repairs complete all as specified and directed.
S&F in replacement Drivers for LED street lights 45W/ 70W / 90W / 120W, 230 Volts, 50 HZ complete all as specified and directed.
out the leakage water and fill the gland packing & rubber packing in sluice valve etc complete all as specified and directed by Engineer-in-Charge.
M&L for taking out burnt winding of electric motor fitted with rotating search light from any position, rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning and reinstating in original position complete all as specified and as directed. Note: Quoted rate shall be deemed to be inclusive of any minor spares / parts replaced for successful functionality of the motor.
M&L for brick work with sub class'B' bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4. complete all as specified and directed
M&L for 75mm thick PCC type D-2, (1:4:8) using 40mm graded mechanically crushed stone aggregate as in sub base complete all as specified and directed.
S&F post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge
Demolition of Brickwork or stone boulder masonry/PCC block masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework & precast concrete articles and disposing off rubbish outside MD land complete all as specified and directed.
M&L for 80mm thick machine pressed rubber moulded precast concrete M-40 interlocking coloured paver block any shape and size conforming to IS-15658-2006 with grey cement and pigment including taking down of old paver block complete all as specified as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped end etc complete all as specified and directed
M&L for PCC in 1:2:4 type B1 (using 20mm graded mechanically crushed stone aggregate) as in coping, benching and similar work incl form work complete all as specified and directed
Add or deduct for each 25 mm girth or part thereof over or under 30 cm ditto complete all as specified and directed
Demolition of RCC of any description & in any position (reinforcement cut as required to facilitate demolition) and disposing off rubbish outside MD land complete all as specified and directed.
M&L for PCC in surface channels and drains type C-1 (1:3:6) using 20 mm graded mechanically crushed stone aggregate complete all as specified and directed
M&L for Mild steel TMT bars of 10 mm dia as in reinforcement, cut to length, bent to shape required, including cranking, bending, spirally looping for columns, hooking ends & binding with and including mild steel annealed wire of not less than 0.9 mm dia or securing with clips complete all as specified and directed
M&L for 15mm thick rendering on brick or concrete surface in cement mortar 1:4 and finishing the surface with even and smooth without using extra cement complete all as specified and as directed.
Taking down cement plastering of any thickness on brick, concrete or stone walls, partitions, ceilings etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground (Posts embedded in concrete) complete all as specified and directed
Dismantling wrought iron of mild steel work of any description not otherwise provided for complete all as specified and as directed by the Engr-in-Charge.
Supply and fabricating framed steel work and fixing as in doors or gates of angle or other section with gusset plates, rails, braces, etc., Fe-290 (Gde E-165) complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (incl of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drill
ing, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by the Engineer-in-Charge
M&L Plain Cement Concrete (1:3:6) type C-2, using 40 mm graded mechanically crushed stone aggregate as in foundation filling of posts and struts., etc., complete all as specified and as directed.
M&L for Preparation of new steel surfaces exceeding 10 cm in width or girth, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed..
M&L for Plain cement concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes, after they are laid and tested, with plain cement concrete 1:4:8 type D2 (using 40 mm graded mechanically crushed stone aggregate) all as specified and directed.
M&L for Plain cement concrete bed to 200 mm bore drain pipe including packing under and haunching against the sides of pipes, after they are laid and tested, with plain cement concrete 1:4:8 type D2 (using 40 mm graded mehcanically crushed stone aggregate) all as specified and directed.
M&L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid under trenches jointed in CM (1:1) complete all as specified and as directed.
M&L for 200mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid under trenches jointed in CM (1:1) complete all as specified and as directed.
Cutting into existing manholes for connecting new drains ,making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required for 150mm bore pipe, complete all as specified and as directed..
Cutting into existing manholes for connecting new drains ,making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required for 200mm bore pipe, complete all as specified and as directed..
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_822348.xls
BOQ • 0.55 MB
53TenderPages.pdf
Tender Documents • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .