Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | ₹1.5 Cr | 1 | Accepted-AOC AGREEMENT EXECUTED |
| 2 | 2₹1.8 Cr+₹27.3 L (18.4%)Rejected-Finance CHANGANACHERRY GENERAL ELECTRICAL WORK | ERNAKULAM | KERALA | 682001 | ₹1.8 Cr+₹27.3 L (18.4%) | 2 | Rejected-Finance REJECTED |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECTED |
| 4 | Rejected-Technical | - | - | Rejected-Technical REJECTED |
Tender Value
₹1.6 Cr
EMD Value
₹50,000
Closing Date
6 Mar 2023, 5:00 pmClosed
SUPERINTENDING ENGINEER
Kochi Municipal Corporation Park Avenue Ernakulam , Kochi 682011
FCE2/2252/22 RAY Projects G 11 Providing Electrical Installations-General Electrical Work
2023_LSGD_553431_2
Kochi municipal Corporation FCE2/2252/22_RAY
Open Tender
Electrical Works
Item Rate
365 days
Ernakulam
Please refer Tender documents.
8 documents required · 8 mandatory
₹6,508
Yes
₹50,000
Yes
11 Jul 2023
25 Feb 2023
8 Mar 2023
25 Feb 2023
6 Mar 2023
25 Feb 2023
Amount
Providing EI
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.2:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Short point
OD90734/2022-2023:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Two light controlled by 6A switch - Short point
OD90735/2022-2023:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Three light controlled by 6A switch - Short point
OD90504/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). 4light controlled by 6A switch-
OD90509/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). 5 light controlled by 6A switch-
90.2.1.5:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
OD90517/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control ceiling fan point with 2 nos 6 A 2 way switch , 3 plate ceiling rose & with socket size stepped electronic regulator.
OD90492/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). 6 light controlled by 6A switch-
OD90494/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). 7 light controlled by 6A switch-
OD90496/2022-2023: Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).8 light controlled by 6A switch-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
OD93530/2022-2023:Supply and Labour charges for carrying out telephone wiring complete through all floors with multi pair telephone cable as below through 20mm PVC conduits(The leads should be ferrule marked for identification). 4 pair telephone wire
OD90217/2022-2023:Supply and laying armoured Jelly filled telephone cables through PVC pipes/clamping to cable trays directly with necessary saddles.(The leads should be ferrule marked for identification). 10 pair armoured
OD90218/2022-2023: Supply and laying armoured Jelly filled telephone cables through existing PVC pipes/clamping to cable trays directly with necessary saddles.(The leads should be ferrule marked for identification). 50 pair armoured
OD90221/2022-2023:Supply , Fixing and connecting following modular type telephone jack in suitable MS box, concealed, for connecting telephone. Single jack shuttered
OD90234/2022-2023:Supply and Providing telephone junction box with hinged doors fabricated out of No. 16 SWG CR sheet steel with two coat of corrosion resistant primer and painted with finish quality synthetic enamel paint. Junction box should have enough space for providing the following connectors and termination. 1 x 10 pair
OD90235/2022-2023:Supply and Providing telephone junction box with hinged doors fabricated out of No. 16 SWG CR sheet steel with two coat of corrosion resistant primer and painted with finish quality synthetic enamel paint. Junction box should have enough space for providing the following connectors and termination. 5 x 10 pair
OD90249/2022-2023: Supply and Providing telephone junction box with hinged doors fabricated out of No. 16 SWG CR sheet steel with two coat of corrosion resistant primer and painted with finish quality synthetic enamel paint. Junction box should have enough space for providing the following connectors and termination. 10 x 10 pair
OD90246/2022-2023:Supply and Providing 10 pair telephone connectors (Make : KRONE) on above stands with necessary supports and providing terminations with ferrule identification of terminals
OD90250/2022-2023:TV Outlets Supply and carrying out TV wiring complete through all floors with foam filled TV cable as detailed below through existing 20mm PVC conduits(The leads should be marked for identification) RG-6
OD90251/2022-2023:Supply , Fixing and connecting modular type TV co-axial socket in suitable M.S. box, for connecting TV as below Single
OD90029/2022-2023:Panel Boards Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. MSB Incomer:- 1000A, FP, 415V,50kA(Ics),MP based ACB set at 85% with 3 Over Current and inbuilt earth fault release and low set earth fault protection using neutral CT-1No Meters & relays. (a) RYB indication lamp with 2A HRC fuse - 1 Set. (b) Low set earth fault protection relay with suitable CT- 1 Nos. (C) Restricted Earth fault Relay type CAG 14 with 10%-40% setting range with suitable CT - 1 No. (d)winding temperature relay with primary trip-1No Outgoing 400A FP MCCB 36kA-2Nos. 200A TP MP BASED MCCB 36kA (Ics) with 3 phase CT operated Electronic energy meter and provision for padlock -1 No. All MCCB's are with, Rotary operated handle and all necessary accessories. Busbar:1 Set TPN copper bus bars suitably rated for 1000A.
OD90030/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63 mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. SB 1 Incomer: 400A TPN ISOLATOR Outgoing:- 100A TP MCCB 36kA-10Nos. Busbar:1 Set TPN Copper bus bars suitably rated for 400 A
OD90031/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. Incomer:1 Incomer: 315A TPN Isolator Meters & relays. RYB indication lamp with 2A HRC fuse- 1 Set. Digital Meter for Voltage and Current and suitable CT-1set Outgoing:- 160A FP MCCB 25 kA (Ics)-1 No. 63A FP MCCB 25 kA (Ics) -4Nos. Busbar:1 Set TPN copper bus bars suitably rated for 400A
OD90032/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. CSB Incomer: 160A ATS with generator controller for start/stop -1 No. Meters & Relays: RYB indication lamp with 2A SP MCB - 1 Sets. Outgoing: 125A TPN ISO -1Nos. 63A TP MCCB,25kA -6Nos. Busbar:1 Set TPN copper bus bars suitably rated for 320A
OD90043/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. METERING PANELS Incomer: KSEB SIDE 100A TPN ISO-1 No Outgoing:- 1 No.32A SPN SF HRC with 20 A HRC , Provision for fixing 1No. 1 phase energy meter, 1no. 32A Bakelite Fuse Unit with 20 A HRC ,1 no 2 way neutral link -12Nos Busbar:1 Set TPN copper bus bars suitably rated for 100A Complete with all inter connections, powder coating, control wiring etc., as per IS, CEA Regulations and General conditions/ Technical Specifications.(Provision for sealing meter chambers and Busbar on KSEB side)
OD90045/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. METERING PANELS Incomer: KSEB SIDE 100A TPN ISO-1 No Outgoing:- 1 No.32A SPN SF with 20A HRC fuse , provision for fixing 1No. 1phase energy meter, 1no. 32A Bakelite Fuse Unit with20A HRC , 1no 32A 2way N/L -7Nos Busbar:1 Set TPN copper bus bars suitably rated for 100A Complete with all inter connections, powder coating, control wiring etc., as per IS, CEA Regulations and General conditions/ Technical Specifications.(Provision for sealing meter chambers and Busbar on KSEB side)
OD90046/2022-2023:Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. METERING PANELS Incomer: KSEB SIDE 100A TPN ISO-1 No Outgoing:- 1 No.32A SPN SF with 20A HRC fuse ,Provision for 1No. 1phase energy meter, 1no. 32A Bakelite Fuse Unit with 20A HRC , 1 no 32A 2way N/L ,-9Nos Busbar:1 Set TPN copper bus bars suitably rated for 100A Complete with all inter connections, powder coating, control wiring etc., as per IS, CEA Regulations and General conditions/ Technical Specifications.(Provision for sealing meter chambers and Busbar on KSEB side)
OD90047/2022-2023:PUMP PANEL Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. Incomer: 100A TPN Isolator-1 No. Meters & relays. (a)Multifunction digital meter with displays for voltage and current with necessary CT’s-1 No. (b) RYB indication lamp with 2A SP MCB - 1 No. Outgoing:- 3Nos - 25A TP MCB (D CURVE)with Star delta starters for 5.0HP motors and on/off indication lamps with25A 3 pole two way rotary cam operated switch with center OFF 1Nos -16A TP MCB(D CURVE) with DOL starters for 3HP motors and on/off indication lamps 25A 3 pole two way rotary cam operated switch with center OFF 1Nos -16A TP MCB(D CURVE) with DOL starters for 2HP motors and on/off indication lamps 25A 3 pole two way rotary cam operated switch with center OFF 1No - 25A TP MCB(D CURVE) with Star Delta starters for 5HP motors and on/off indication lamps 32A TP MCB (D CURVE) 10kA- 2No 25A TP MCB (D CURVE) 10kA- 5Nos Busbar:1 Set TPN copper bus bars suitably rated for100A.
OD90048/2022-2023: CSSB Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. Incomer: 63A TPN Isolator Meters & relays. (a)Multifunction digital meter with displays for voltage and current with necessary CT’s-1 No. (b) RYB indication lamp with 2A SP MCB - 1 No. Outgoing:- 32A 4P MCB -5Nos. 25A 4P MCB -1Nos. 16A 4P MCB -2Nos. 32A DP MCB -1Nos. Busbar:1 Set TPN Cu bus bars suitably rated for 63A
OD90049/2022-2023: LIFT PANEL Design, Fabrication, Supply, Erection,Testing and Commissioning of cubicle type dust and vermin proof free standing, floor mounting panel boards as per general specifications and drawings consisting of the following complete fabricated from 1.63mm CRCA sheet with powder coating etc.as per IS 8623 Regulations and General conditions/ Technical Specifications. Incomer: 63A FP Isolator Outgoing:- 32A 4P RCBO 300mA -1No. 25A 4pole RCBO 30mA-1No with 4nos of 6A SP MCB Busbar:1 Set TPN Cu bus bars suitably rated for 40A
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
90.11.1.13:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.37:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
90.12.7.38:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
OD90059/2022-2023:Supply & Laying of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid underground in the exiting trench at minimum depth not less than 750mm and shall be provided with sand cushioning and brick protection. The rate shall exclude cost of excavation and back filling. The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing. 3x1.5 Sq.mm Copper
OD90061/2022-2023:Supply & Laying of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid underground in the exiting trench at minimum depth not less than 750mm and shall be provided with sand cushioning and brick protection. The rate shall exclude cost of excavation and back filling. The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing. 3x2.5 Sq.mm Copper
OD90063/2022-2023:Supply & Laying of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid underground in the exiting trench at minimum depth not less than 750mm and shall be provided with sand cushioning and brick protection. The rate shall exclude cost of excavation and back filling. The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing. 10x1.5 Sq.mm Copper
OD90854/2022-2023:Supply & providing cable end terminations for the following cables using single compression brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size, etc. complete. 2 C x 6 Sq.mm
OD90650/2022-2023:Supply & providing cable end terminations for the following cables using single compression brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size, etc. complete. 3 Cx 4 Sq.mm
OD90651/2022-2023:Supply & providing cable end terminations for the following cables using single compression brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size, etc. complete. 3 C x 6 Sq.mm
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.31:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
OD90180/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4sq. mm
OD90194/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3x2.5 sq mmXLPE Cu
OD90195/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3x1.5 q. mm Cu
OD90196/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2x2.5 Sq. mm XLPE Cu
OD90198/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2x1.5 Sq. mm XLPE Cu
OD90199/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of 113PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 10x1.5 Sq. mm XLPE Cu
OD90201/2022-2023:Earthing Supply & providing continuous earthing conductors and earth pits as per the technical specifications and IS 3043/87. Supply & Labour charges for Providing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, Electrodes etc., excavation in all classes of soil, terminal filling with filling salt, sand and charcoal, construction of earth chamber and covering with heavy duty Cast Iron Cover hinged to Cast Iron Frame, including excavation of earth pit as per the technical specifications and IS 3043
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
6.14:Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
OD90210/2022-2023: Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 50x6 mm GI flat
OD90256/2022-2023:LIGHTNING PROTECTION SYSTEM Supply and Erection of Lightning Protection system horizontal air terminations and vertical down conductors with all accessories like conductor holder, test terminals, wall holders complete as per IEC / IS 62305 8mm dia Aluminium conductor Horizontal laying on top of the building
OD90257/2022-2023: LIGHTNING PROTECTION SYSTEM Supply and Erection of Lightning Protection system horizontal air terminations and vertical down conductors with all accessories like conductor holder, test terminals, wall holders complete as per IEC / IS 62305 8mm dia Aluminium conductor Vertical down including test links
OD90258/2022-2023:Providing and fixing of Cross Connector/T Connector: to route vertical down conductor /mesh formation made of stainless steel SS 304 grade with necessary screws etc as required. Installed with 4 hexagonal bolts with M8 hexagonal nuts according to (IS/IEC 62305)
OD90259/2022-2023:Supply and Providing expansion piece with connector: For equalizing temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with L or T Connector: using stainless steel SS 304 grade . Quick installation using hexagonal bolt. Conforms to the requirements according to (IS/IEC 62305)
OD90260/2022-2023:"Vertical air terminal with accessories: Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod Meets the requirement of VDE0185/305(IS/IEC 62305)
OD90261/2022-2023:ROD EARTH STATION. Supply,Providing and laying Rod Earthing using 20mm dia 3 mtr long copper coated steel electrode with all required accessories and adding earth conductivity enhancing mineral compound, construction of earth chamber and covering with heavy duty Cast Iron Cover hinged to Cast Iron Frame, including excavation of earth pit as per the technical specifications and IS.
OD90307/2022-2023:"Supply,Providing and laying copper bonded steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding "
OD90359/2022-2023:LIGHT FIXTURES, FANS etc. Supply , fixing, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary brackets, down rods and 3-core flexible wires etc. Ceiling light fixture LED 9 W
OD90363/2022-2023:Supply testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary brackets, down rods and 3-core flexible wires etc. Mirror Light Fixture 8 W LED
OD90365/2022-2023:supply, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary brackets, down rods and 3-core flexible wires etc. Wall light fixture 9W LED with ornamental bracket ,shade etc
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD364104/2022-2023:Supply, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary brackets, down rods and 3-core flexible wires etc. Wall light fixture 9W LED with ornamental bracket ,shade etc LED Bulkhead fitting with 9W LED
OD90370/2022-2023: Supply, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures with all necessary brackets, and 3-core flexible wires Post top light with 3m pole and cable box ,9w LED ,Errection of pole etc complete
OD90376/2022-2023:Supply, fixing, testing and commissioning of following light fixtures with all necessary brackets, down rods and 3-core flexible wires etc. Installation of gate top light with 35 W LED With all accessories
OD90377/2022-2023:Labour charges for fixing, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary brackets, down rods and 3-core flexible wires etc. Installation of bollard lights with pole and 9W LED
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD90382/2022-2023: Supply , fixing, testing and commissioning on Exhaust fan of the following size ,wiring ,giving connection as required 305mm sweep with metal leaf double ball bearing
OD364534/2022-2023:Supply and fixing call bell ding dong/bird/musical and giving connection
OD90384/2022-2023:MISCELLANEOUS Supply &Fixing of LT danger notice boards.
OD90386/2022-2023:Supply & Fixing of shock treatment chart in glass with frame
OD90388/2022-2023:Supply and Laying of 11kV grade Synthetic Insulated mat conforming to IS:15652:2006
OD90389/2022-2023:Supply& Laying of 440V grade Synthetic Insulated mat conforming to IS:15652:2006
OD90391/2022-2023:Supply and fixing DCP type fire extinguisher 5 Kg.
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.5:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.1.7:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
OD90463/2022-2023: Supply &Installation of 6mm thick MS checkered plate and filling fire proof partition between floors in the electrical ducts.
OD90469/2022-2023:Supply and fixing Weather proof box (IP 66/67) with loop in loop out terminal with provision for earthing &din rail of min. size 104mm x 104mm x 70mm. Including IP rated cable glands
OD90470/2022-2023:Supply and fixing Weather proof box (IP 66/67) with loop in loop out terminal with provision for earthing &din rail of min. size 98mm x 98mm x 61mm. Including IP rated cable glands
ELCON ELECTRICALS
Biju E.M
KURIALA CHACKO
Bidder Name
Biju E.M
Kittu Electricals private limited
ELCON ELECTRICALS
KURIALA CHACKO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .