| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹68.5 L+₹33,106.12 (0.49%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹71.2 L+₹3.0 L (4.39%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical L6 | |
| 5 | Rejected-Technical | - | Rejected-Technical L8 |
Tender Value
₹83.9 L
EMD Value
₹50,000
Closing Date
11 Jul 2023, 2:00 pmClosed
The Executive Engineer
Office of the Executive Engineer, PWD Buildings Division Ernakulam
The work includes only structure of building except masonry works lintels sunshade joineries plastering flooring finishing works electrification etc Structure has been analysed and designed for two storey with wind effect
2023_PWD_585136_1
PWD/BLDG/TR/24630/2022_23_1
Open Tender
Civil Works - Buildings
Item Rate
270 days
Karingamthuruth, N.Paravurr
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹50,000
Yes
30 Oct 2023
1 Jul 2023
13 Jul 2023
1 Jul 2023
11 Jul 2023
1 Jul 2023
1 Jul 2023 - 11 Jul 2023
Amount
ESTIMATE
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD226861/2022-2023:Soil stabilization by driving10 cm dia solid pipe at 60 cm c/c 80 cm using JCB/hydraulic excavator and filling the hole with graded stone aggregate of 20 mm and 12.5 mm again compacting the aggregate with solid pipe to get the soil well compacted as per the direction of Engineer-in -charge.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
OD214878/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Cement content obtained as per mix design shall be used by the contractor at site to obtain the requirerd strength. Note:-Minimum Cement content considered in this item is @ 330 kg/ cum. Excess cement used as per the design mix is not payable separately as per order No. CE/BL/GL/6541/2015 dated 30/08/2017 of CE buildings PWD .All work upto plinth level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
OD214879/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Cement content obtained as per mix design shall be used by the contractor at site to obtain the required strength. Note:-Minimum Cement content considered in this item is @ 330 kg/ cum. Excess cement used as per design mix not payable separately as per Circular No. CE/BL/GL/6541/2015 dated 30/8/2017 of CE buildings PWD . All work above plinth level upto floor V level
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
OD214884/2022-2023:Supplying and fixing inauguration stone.
JOSEPH K X
K A Nissar
K.S.SAJEEV KUMAR
BENNYTHOMAS
ANWAR P M
HITRUST CONSTRUCTIONS
aseebashraf
JITHIN RADHAKRISHNAN
VSOINS CONSULTANTS PRIVATE LIMITED
Bidder Name
BENNYTHOMAS
K A Nissar
PYNADATH VARGHESE STEPHEN
K.S.SAJEEV KUMAR
aseebashraf
JITHIN RADHAKRISHNAN
HITRUST CONSTRUCTIONS
JOSEPH K X
ANWAR P M
VSOINS CONSULTANTS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .