Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAdmitted-Finance | ₹3.3 L | L1 | Admitted-Finance |
| 2 | L2₹3.7 L+₹43,312.56 (13.2%)Admitted-Finance | ₹3.7 L+₹43,312.56 (13.2%) | L2 | Admitted-Finance |
| 3 | L3₹3.7 L+₹44,174.96 (13.5%)Admitted-Finance | ₹3.7 L+₹44,174.96 (13.5%) | L3 | Admitted-Finance |
| 4 | L4₹4.2 L+₹94,548.16 (28.8%)Admitted-Finance | ₹4.2 L+₹94,548.16 (28.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHIVANDER NAG L2 | BALJINDER SINGH L3 | AJAY SINGH L1 | sanjeev kumar kalia L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Cleaning of all type of concrete /masonary surface by throughly brooming with wire brush & surface grinder to remove the plaster peeling, algae ,dust,dirt and all foreingn material consolidated on surface complete in all respect | 114.96 | P/sqm | 160 ₹18,393.6 | 80 ₹9,196.8 | 119 ₹13,680.24 | 60 ₹6,897.6 Lowest |
| 2.00 | Water proofing treatment on water tank on specified or marked area where heavy leakages are noticed such as bottom of tank and horizontal joints of RCC pannels of walls including cost of cutting holes in the concrete with chieseling hammering and fixing nozzles for injection grouting of water proof compound of reputed and approved brand such as Perma-Grout or equivalent make at one foot interval to block voids or cappilaries to arrest complete leakages of RCC water retaining structures as per direction and satisfaction engineer-in-charge. | 1,330 | Nozzles | 170 ₹2,26,100 | 190 ₹2,52,700 | 120 ₹1,59,600 Lowest | 170 ₹2,26,100 |
| 3.00 | Providing and laying water proofing treatment on inner wall surface of RCC water storage tank by applying cement slurry mixed with polymer water-proofing compound of approved brand such as Perma Hypercrete or equivalent make in ration 1:1 or as recommended by the company including cost of providing fibre mesh in first layer (over lap of joint of fabric mesh shall not be less then 10cm., final layer of well stirred slurry of cement polymeric water proofing compound such as Perma Hypercrete or equivalent make applied with brush in perpendicular direction complete with cost of cement and sand as per direction and satisfaction engineer-in-charge | 114.96 | P/sqm | 480 ₹55,180.8 | 250 ₹28,740 Lowest | 460 ₹52,881.6 | 315 ₹36,212.4 |
| 4.00 | Supply and erction of PVC Jointless flat 3 core cable as 10mm sq per BIS 694-1990 (Latest with upto date ammendments ) suitable for the pump set offered from OCB to motor, motor to starter including all other electric equipments such as thimbles, flexible nut & bolt, cable glands etc.laid in pipes or trenches under floor. The type and make will be subjected approval of HPSEBL authoroties in case of non aacceptance by HPSEBL authorities it shall have to be replaced by the tendrer free of cost. | 60 | P/rmt | 500 ₹30,000 | 800 ₹48,000 | 450 ₹27,000 Lowest | 1,400 ₹84,000 |
| 5.00 | Providing and fixing of Kirloskar/ Kilburn/ IVC/Fouress/ Gled/BHEL/ Leader/Kartar make Cast Steel Double flanged Non return Valve various dia of class-ASA 150 as per relavant IS standards withstand nominal seat pressure 20.00 KG/Cm sqr. Conforming to IS BS :1868/API -600(latest with up to date ammendments if any ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge having following nominal diameters: 65mm | 1 | Each | 15,000 ₹15,000 | 7,500 ₹7,500 Lowest | 39,000 ₹39,000 | 13,500 ₹13,500 |
| 6.00 | Providing & fixing Cast Iron double flanged sluice valve various dia of Kirloskar /KSB/ Kilburn / BHEL/ Leader make of following dia and class PN- 1.6 capable of with standing nominal seat pressure of 16.00kg/Cm2. (as per IS -780-1984 latest with up to date ammendments if any) complete in all respect as per diection and and satisfaction of engineer in charge .65mm | 3 | Each | 6,000 ₹18,000 Lowest | 6,000 ₹18,000 Lowest | 6,800 ₹20,400 | 14,000 ₹42,000 |
| 6.01 | 50mm dia | 1 | Each | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest | 5,800 ₹5,800 | 11,000 ₹11,000 |
| 7.00 | Making connection of G.I. pipe i.e. cutting welding confirming to ISI specifications i.e. commissioning complete in all respects of following dia from MST (Earth work in trenches shall be measured and paid for seprately all leads and lifts and as per satisfaction of engineer in charge. | 2 | Each | 1,800 ₹3,600 | 1,500 ₹3,000 | 4,800 ₹9,600 | 1,400 ₹2,800 Lowest |
Tender Value
₹5.5 L
EMD Value
₹10,974
Closing Date
4 Apr 2026, 11:00 amClosed
Executive Engineer
Executive Engineer Jal Shakti Division Fatehpur
Restoration of rain damages for LWSS Kuthan in tehsil fatehpur distt kangra H.P
2026_HPIPH_132030_1
NIT NO. 10773-10810 dated 19.03.2026
Open Tender
Civil Works
Item Rate
Tehsil Fatehpur
As per notice inviting Tender
8 documents required · 8 mandatory
₹350
EE Fatehpur
₹10,974
9 Apr 2026
19 Mar 2026
4 Apr 2026
19 Mar 2026
4 Apr 2026
19 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Cleaning of all type of concrete /masonary surface by throughly brooming with wire brush & surface grinder to remove the plaster peeling, algae ,dust,dirt and all foreingn material consolidated on surface complete in all respect | - | P/sqm | - | - |
| - | Water proofing treatment on water tank on specified or marked area where heavy leakages are noticed such as bottom of tank and horizontal joints of RCC pannels of walls including cost of cutting holes in the concrete with chieseling hammering and fixing nozzles for injection grouting of water proof compound of reputed and approved brand such as Perma-Grout or equivalent make at one foot interval to block voids or cappilaries to arrest complete leakages of RCC water retaining structures as per direction and satisfaction engineer-in-charge. | - | Nozzles | - | - |
| - | Providing and laying water proofing treatment on inner wall surface of RCC water storage tank by applying cement slurry mixed with polymer water-proofing compound of approved brand such as Perma Hypercrete or equivalent make in ration 1:1 or as recommended by the company including cost of providing fibre mesh in first layer (over lap of joint of fabric mesh shall not be less then 10cm., final layer of well stirred slurry of cement polymeric water proofing compound such as Perma Hypercrete or equivalent make applied with brush in perpendicular direction complete with cost of cement and sand as per direction and satisfaction engineer-in-charge | - | P/sqm | - | - |
| - | Supply and erction of PVC Jointless flat 3 core cable as 10mm sq per BIS 694-1990 (Latest with upto date ammendments ) suitable for the pump set offered from OCB to motor, motor to starter including all other electric equipments such as thimbles, flexible nut & bolt, cable glands etc.laid in pipes or trenches under floor. The type and make will be subjected approval of HPSEBL authoroties in case of non aacceptance by HPSEBL authorities it shall have to be replaced by the tendrer free of cost. | - | P/rmt | - | - |
| - | Providing and fixing of Kirloskar/ Kilburn/ IVC/Fouress/ Gled/BHEL/ Leader/Kartar make Cast Steel Double flanged Non return Valve various dia of class-ASA 150 as per relavant IS standards withstand nominal seat pressure 20.00 KG/Cm sqr. Conforming to IS BS :1868/API -600(latest with up to date ammendments if any ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge having following nominal diameters: 65mm | - | Each | - | - |
| - | Providing & fixing Cast Iron double flanged sluice valve various dia of Kirloskar /KSB/ Kilburn / BHEL/ Leader make of following dia and class PN- 1.6 capable of with standing nominal seat pressure of 16.00kg/Cm2. (as per IS -780-1984 latest with up to date ammendments if any) complete in all respect as per diection and and satisfaction of engineer in charge .65mm | - | Each | - | - |
| - | 50mm dia | - | Each | - | - |
| - | Making connection of G.I. pipe i.e. cutting welding confirming to ISI specifications i.e. commissioning complete in all respects of following dia from MST (Earth work in trenches shall be measured and paid for seprately all leads and lifts and as per satisfaction of engineer in charge. | - | Each | - | - |
stage.html
html • 0.03 MB
techsummary_195248.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.37 MB
form6.pdf
Tender Documents • 0.14 MB
form8.pdf
Tender Documents • 1.41 MB
tc.pdf
Tender Documents • 0.40 MB
BOQ_195248.xls
BOQ • 0.28 MB
core_000118.pdf
PDF • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .