After Completion of DLP period under PMGSY Damages causeway, slab culvert, walls and P.C. Work of Sangore-Dasoli-Danu motor road (One time maintenance)
2023_pwd_60401_1
1064/3A Dated 20-06-2023
Open Tender
Civil Works - Roads
Item Rate
270 days
Berinag
As per bid documents
3 documents required · 3 mandatory
₹4,720
Executive Engineer, TD PWD Berinag
₹1.1 L
Yes
14 Jul 2023
3 Jul 2023
14 Jul 2023
3 Jul 2023
14 Jul 2023
3 Jul 2023
Amount
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Plain/Reinforced cement concrete in Sub Structure complete as per drawing and technical specifications.PCC Grade M25 Using concrete Mixer.
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Excavation in foundation for retaining & brest walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge
Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC 1:3:6
Stone masonry in cement mortar for substructure complete as per drawing &technical specification Clauses 702, 704, 1202 and 1204 RR 1:5
Providing concrete for plain/ reinforced concrete inSubstructure complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 R.C.C M 25
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6)
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications PCC 15 (1:2:4)
Random rubble stone masonary laid in dry by locally available approved stone in retaining walls ,breast walls etc including supply of all material, labour, T&P etc required for proper completion of the work as per detailed P.W.D specifications and as directed by Engineer in Charge and as per prescribed drawings .
Hand packed stone filling in the back of retaining walls by locally available approved stone including supply of all material ,labour T&P etc.
Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914
WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compactingto the required density grading 2 as per Technical Specification Clause 405
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compactingto the required density grading 2 as per Technical Specification Clause 405
Tack coat using VG-10 grade bitumen Over dry and hungry bituminous surfaces @0.40 kg/sqm
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Bitumen (VG-10)
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510
Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting ,1.5mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x450 mm x600 mm below ground level as per drawing and technical specification clause 801 (A) 60 cm x 60 cm
60 cm circular for speed limit and showing type of road
Surface Drains in Soil Construction of unlined surface drains of average cross-sectional area 0.40sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307
Providing and Laying of Mechanically Woven Double Twisted Hexagonal shapedGabions (Zinc plus PVC coated), of size 3mX1mX1m with two diaphragms at 1minterval, having mesh opening 100mmx120 mm, mesh wire diameter 2.7mm/3.7mm,edge/selvedge wire diameter 3.4/4.4 mm and lacing wire diameter 2.2/3.2 mm. (Thework includes filling boulders in the gabions).
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4)
stage.html
html • 0.02 MB
finance_73353.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .