Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹14.4 L+₹2.7 L (23.3%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹15.6 L+₹4.0 L (33.9%)Rejected-Finance | L3 | Rejected-Finance other than lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
23 Nov 2020, 6:00 pmClosed
GE SAMBA
GE SAMBA
REPAIR REPLACEMENT IMPROVEMENT OF VOLTAGE STABILIZER LT PANELS AND JUNCTION BOX AT MIL STN SAMBA
2020_MES_378040_2
GE/SMB/T-40/2020-21
Open Tender
Civil Works - Others
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹30,000
Yes
18 Jan 2021
3 Nov 2020
25 Nov 2020
3 Nov 2020
23 Nov 2020
7 Nov 2020
3 Nov 2020 - 4 Nov 2020
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out any type of soil complete all as specifed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 120 Sqmm, 3.5 core including making electrical connection complete all as specified. (Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 95 Sqmm, 3.5 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 70 Sqmm, 3.5 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 50 Sqmm, 3.5 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 35 Sqmm, 3.5 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 4 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
Laying only or passing through pipe in replacement underground cable PVC sheathed, XLPE insulated steel strip armoured LT 1100 volts grade with aluminium conductor of size 16 Sqmm, 2 core including making electrical connection complete all as specified.(Note: XLPE cbale will be issued under Sch 'B')
M&L in replacement of aluminium thimble 120 Sqmm as per specified
M&L in replacement of aluminium thimble 95 Sqmm as per specified
M&L in replacement of aluminium thimble 70 Sqmm as per specified
M&L in replacement of aluminium thimble 50 Sqmm as per specified
M&L in replacement of aluminium thimble 35 Sqmm as per specified
M&L in replacement of aluminium thimble 25 Sqmm as per specified
M&L for cutting of bitumen road/PCC road/hard standing for laying of GI pipe and passing of cable including making good to disturbed surface with PCC 1:4:8 and matching with existing surface complete all as specified.
Supplying and laying GI tubing light grade of size 80 mm bore for cable protection complete all as specified.
Supplying and laying GI tubing light grade of size 50 mm bore for cable protection complete all as specified.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 200 KVA to 250 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 100 KVA to 160 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 50 KVA to 75 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Transportation of voltage stabilizer of any make, capacity from 200 KVA to 250 KVA to civil workshop and returning back after necessary repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Transportation of voltage stabilizer of any make, capacity from 100 KVA to 160 KVA to civil workshop and returning back after necessary repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Transportation of voltage stabilizer of any make, capacity from 50 KVA to 75 KVA to civil workshop and returning back after necessary repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 200 KVA to 250 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 100 KVA to 160 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 50 KVA to 75 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
M&L for re-winding of stabilizer coils of any type/make with superior quality super enamelled copper winding wire of suitable gauge and number of turns alongwith allied materials such as cork sheet, fibre glass insulation/paper isulation cotton, empire tape and woodeen blocks, bolts, nuts and washers, soldering and other packing materials complete all as directed by Engr-in-Charge.
M&L for heat treatment at the workshop furnance of complete core before and after re-assembly of coil into limps after rewinding for stabilizer of any make/capacity complete all as directed by Engr-in-Charge.
Repairing the voltage stabilizer of any make, capacity from 200 to 250 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.Make : As per OEM
33(b) Circuit control/trigger transformer.Make : As per OEM
33(c ) Main terminal block.Make : As per OEM
33(d) Dimmer. Make : As per OEM
33(e) Choke coils.Make : As per OEM
33(f) Carbon brush.Make : As per OEM
33(g) Spacer for Dimmer coils.
33(k) Resistance capacitance net work.Make : As per OEM
33(l) Input switch to stop over running of dimmer start motor.Make : As per OEM
33(m) Servo motor with 20 Kg.cm torque.Make : As per OEM
33(n) Driving gear.Make : As per OEM
33(o) Bearing for dimmer coils.Make : As per OEM
33(p) Terminal connections brass rod with bush.Make : As per OEM
33(q) Protection alarm circuit. Make : As per OEM
Repairing the voltage stabilizer of any make, capacity from 160 to 100 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.Make : As per OEM
47(b) Circuit control/trigger transformer.Make : As per OEM
47(c ) Main terminal block.Make : As per OEM
47(d) Dimmer. Make : As per OEM
47(e) Choke coils.Make : As per OEM
47(f) Carbon brush.Make : As per OEM
47(g) Spacer for Dimmer coils.Make : As per OEM
47(h) Dimmer coils terminals.Make : As per OEM
47(l) Input switch to stop over running of dimmer start motor.Make : As per OEM
47(m) Servo motor with 10 Kg.cm torque.Make : As per OEM
47(n) Driving gear.Make : As per OEM
47(o) Bearing for dimmer coils.Make : As per OEM
47(p) Terminal connections brass rod with bush.Make : As per OEM
47(q) Protection alarm circuit. Make : As per OEM
Repairing the voltage stabilizer of any make, capacity from 75 to 50 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.Make : As per OEM
61(b) Circuit control/trigger transformer.Make : As per OEM
61(c ) Main terminal block. Make : As per OEM
61(d) Dimmer. Make : As per OEM
61(e) Choke coils.Make : As per OEM
61(f) Carbon brush.Make : As per OEM
61(g) Spacer for Dimmer coils.Make : As per OEM
61(h) Dimmer coils terminals.Make : As per OEM
61(l) Input switch to stop over running of dimmer start motor.Make : As per OEM
61(m) Servo motor with 10 Kg.cm torque.Make : As per OEM
61(n) Driving gear.Make : As per OEM
61(o) Bearing for dimmer coils.Make : As per OEM
61(p) Terminal connections brass rod with bush.Make : As per OEM
61(q) Protection alarm circuit. Make : As per OEM
Supply & toping up of new transformer oil (in sealed barrel) having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified. Make: Savita/Castrol/Power True/Truoil.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 200 Amps in sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 100 Amps, sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 63 Amps, sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T /HPL/Havells.
S&F in replacement of switch fuse disconector switch, 4 pole, 415 volts, 50 Hz, 320 Amps suitable for Cylindrical / DIN fuse-link in sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of switch fuse disconector switch, 4 pole, 415 volts, 50 Hz, 200 Amps in sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of switch fuse disconector switch, 4 pole, 415 volts, 50 Hz, 100 Amps in sheet steel enclosure complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
Supply, installation, testing & commisioning in replacement of factory made LT feeder pillar box indoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 300 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 2 mm CRCA sheet duly powder coated and 40x40x6 mm angle iron frame work duly powder coated finish, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long , 15 cm grouted in PCC of ratio 1:3:6 . Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. The scope of the work also includes supply and fixing the following:- INCOMING:- (a) ON LOAD change over switch, 4 pole, 200 Amps, open execution type - 01 No. Make: Legrand/L&t/Schneider. (b) MCCB 200 Amps,thermal adjustable and magentic setting having rupturing capacity 35 KA (Ics= 100% Icu) , 4 pole, 415 volts, 50 Hz, along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. Make: Legrand/L&t/Schneider. (c ) Voltmeter digital type 0-500 Volts, flush type -01 No (d) Ammeter digital type 0-300 Amps, flush type and 3 Nos CTs as per load requirement - 01 No (e) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 100 Amps,thermal adjustable and magentic setting having rupturing capacity 25 KA (Ics= 100% Icu) , 3 pole, 415 Volts, 50 Hz AC, along with Extended Ratory handle ,Spreader terminals and phase barrier - 02 Nos. Make: Legrand/L&t/Schneider. (b) MCCB 63 Amps, thermal adjustable and magentic setting having rupturing capacity 16 KA (Ics= 100% Icu), 3 pole, 415 Volts, 50 Hz AC, along with Extended Ratory handle ,Spreader terminals and phase barrier - 04 Nos. Make: Legrand/L&t/Schneider.
Supply, installation, testing & commisioning in replacement of factory made LT feeder pillar box indoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 300 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 2 mm CRCA sheet duly powder coated and 40x40x6 mm angle iron frame work duly powder coated finish, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long, 15 cm grouted in PCC of ratio 1:3:6 and 30 cm clear space from ground level. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. The scope of the work also includes supply and fixing the following:- INCOMING:- (a) MCCB 200 Amps,,thermal adjustable and magentic setting having rupturing capacity 35 KA (Ics= 100% Icu), 4 pole, 415 Volts, 50 Hz, along with Extended Ratory handle ,Spreader terminals and phase barrier- 01 No. Make: Legrand/L&T/Schneider. (b ) Voltmeter digital type 0-500 Volts, flush type - 01 No (c) Ammeter digital type 0-200 Amps, flush type as per load - 01 No. (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 160 Amps,thermal adjustable and magentic setting having rupturing capacity 25 KA (Ics= 100% Icu), 3 pole, 415 Volts, 50 Hz AC,along with Extended Ratory handle ,Spreader terminals and phase barrier - 01 Nos. Make: Legrand/L&T/Schneider. (b) MCCB 63 Amps, thermal adjustable and magentic setting having rupturing capacity 16 KA (Ics= 100% Icu), 3 pole, 415 Volts, 50 Hz AC, along with Extended Ratory handle ,Spreader terminals and phase barrier- 02Nos. Make: Legrand/L&T/Schneider.
Supply, installation, testing & commisioning in replacement of factory made LT feeder pillar box outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 300 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3.15 mm CRCA sheet duly powder coated and 40x40x6 mm angle iron frame work duly powder coated finish, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm, 15 cm grouted in PCC of ratio 1:3:6 and 30 cm clear space fron ground level. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. The scope of the work also includes supply and fixing the following:- INCOMING:- (a) MCCB 250 Amps,thermal adjustable and magentic setting having rupturing capacity 35 KA (Ics=100% Icu), 4 pole, 415 Volts, 50 Hz, along with Extended Ratory handle ,Spreader terminals and phase barrier - 01 No. Make: Legrand/L&T/Schneider. (b ) Voltmeter digital type 0-500 Volts, flush type - 01 No (c) Ammeter digital type 0-200 Amps, flush type with 3 Nos CTs as per load requirement - 01 No. (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 160 Amps, thermal adjustable and magentic setting having rupturing capacity 25 KA (Ics=100% Icu), 3 pole, 415 Volts, 50 Hz AC, along with Extended Ratory handle ,Spreader terminals and phase barrier - 01 Nos. Make: Legrand/L&T/Schneider. (b) MCCB 100 Amps, thermal adjustable and magentic setting having rupturing capacity 16 KA (Ics=100% Icu), 3 pole, 415 Volts, 50 Hz AC,along with Extended Ratory handle ,Spreader terminals and phase barrier - 01Nos. Make: Legrand/L&T/Schneider. (c) MCCB 63 Amps,thermal adjustable and magentic setting having rupturing capacity 35 KA (Ics=100% Icu), 3 pole, 415 Volts, 50 Hz AC, along with Extended Ratory handle ,Spreader terminals and phase barrier- 03Nos. Make: Legrand/L&T/Schneider.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI earth lead wire of size 4.0 mm dia and 15 mm dia bore light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009 complete all as specified and directed
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified.
Supply and fixing in replacement of LT busbar chamber box of minimum size 90 cm (Height) x 70 cm (Width) x 45 cm (Depth), outdoor type, double door type, front/rear opening type suitable for 415 volts, 3 phase, 4 wire (100% neutral), 50 Hz supply system all as specified and directed. Box made out of 3.15 mm CRCA sheet factory made wheather proof, dust proof and vermin proof duly powder coated with 04 Nos hindalco make aluminum busbar 300 Amps, 50 cm each (each busbar having 04 Nos of nuts, bolts, washers) horizentally placed on insulators suitable for & including MCCB 4 Pole 160 A,thermal adjustable and magentic setting having rupturing capacity 25 KA (Ics=100% Icu), 415 volts AC along with Extended Ratory handle ,Spreader terminals and phase barrier hinged and lockable door arrangement complete with interconnections with aluminium solid strips, busbar chamber mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:3:6 and 30 cm clear space from ground level including fixed on angle iron frame complete all as specified and directed by Engineer-in-Charge. The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. (Note: Panel shall be a front/rear opening with cable entry from the bottom). Make of MCCB: Make: Legrand/L&t/Schneider.
Supply and fixing in replacement of LT busbar chamber box of minimum size 30 cm (Height) x 30 cm (Width) x 15 cm (Depth), outdoor type, Single door type, front opening type suitable for 415 volts, 3 phase, 4 wire (100% neutral), 50 Hz supply system all as specified and directed. Box made out of 3 mm (outer) CRCA sheet factory made wheather proof, dust proof and vermin proof duly powder coated with 04 Nos hindalco make aluminum busbar 200 Amps, 50 cm each (each busbar having 04 Nos of nuts, bolts, washers) horizentally placed on insulators suitable for hinged and lockable door arrangement complete with interconnections with aluminium solid strips, busbar chamber wall mounted type including fixed by anchor bolt & nuts complete all as specified and directed by Engineer-in-Charge. (Note: Busbar shall be a front opening with cable entry from the bottom/upper).
Labour only for dismantling LT panel from one site and refix as desired loction within the radius of 2KM of MES complex including all civil work and electric work of LT panel all as specified and directed.
De-assembling submersible motor, three phase, 2900 RPM, 415 Volts, 50 Hz, capacities 10 HP to 22.50 HP for repair and re-assembling the same after necessary repair/ replacement of old defective/ damaged spare parts, complete all as specified and directed Note: New spare parts and repair for old serviceable spare parts will be measured and paid separately under respective items.
Rewinding of burnt/ damaged submersible motor with PVC insulated water proof, annealed solid copper conductor wire of 99.99 % purity of existing specifications and best quality, ISI marked or as per IE specifications, complete all as specified and directed.
De-assembling and removal from foundation the burnt/ non-working induction motors of any make, capacities 15 HP to 125 HP, three phase, 415 Volts, 50Hz send to contractor's workshop for repair and re-assembling, installation, commissioning and testing the same motor on full load after necessary repair/ replacement of old defective/ damaged spare parts, winding from the stator, cleaning the slots including one coat of spray painting matching to existing colour complete all as specified and directed. Note: New spare parts and repair for old serviceable spare parts will be measured and paid separately under respective items.
Rewinding of burnt/ damaged 3 Phase induction motor 1450 RPM, 50 Hz with super enamelled, copper wire of 99.99 % purity, best quality, of existing size specifications and size, incl varnishing, baking & replacement of insulating material ISI marked or as per IE specifications, complete all as specified and directed.
G.M. ENGINEERING SERVICES
M/S GUPTA TRADING CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .