Assistant Engineer (E) EMSD-II, South East, PWD, G
Assistant Engineer (E) EMSD-II, South East, PWD, Giri Nagar Kalkaji, New delhi
RMO various E M services in various Delhi Govt Offices under AE (E) EMSD II South East Giri Nagar Kalkaji New Delhi SH SITC of water automation system at Labour Court Complex Giri Nagar
2026_PWD_289593_1
140/EE(E)/AE(E)-II/EMD South East/PWD/2025-26
Open Tender
Electrical Works
Percentage
30 days
At Site
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹11,906
Yes
13 Apr 2026
6 Apr 2026
13 Apr 2026
6 Apr 2026
13 Apr 2026
6 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation, testing & Commissioning of PUMP House Automation Electrical Panel, wall mounted indoor cubical Panel duly powder coated having suitable size for switchgear and accessories. The panel has to be fabricated from 1.6 mm thick CRCA sheet duly compartmentalized suitable for 415 volt 50Hz A.C supply of suitable size with control wiring in channel, MCB, Relay card channel, Terminal Block, Panel Control Wiring & Panel Stand i/c supplying and fixing of following accessories in panel complete as regd. 1.1) Cooling fan 4" - 1 Nos. 1.2) SPMCB 6-32 Amp. - 2 Nos. 1.3) 32 Amp TPN - 1 Nos. 1.4) Relay card 8 Channel - 3 Nos. 1.5) Push Button Flush Head - 12 Nos. 1.6) Contact Blocks - 30 Nos. 1.7) Push Button & Selector Actuators © 22.5 mm - 3 Nos. 1.8) SMPS 12 VDC 6 Amp. - 2 Nos. 1.9) SMPS 24 VDC 4.5 Amp. - 1 Nos. 1.10) Indicator Gen Next LED 8531 22.5 mm - 15 Nos. 1.11) Panel Light. - 1 Nos. 1.12) "Modular AC Box With 20A SP MCB, Plastic Enclosure 8 Unbreakable Heavy Duty With ISI Plug Top - 1 No. 1.13) MMU (Master Microprocessor Unit) With Smart Graphical Display Size 7" Inbuilt Software Application with wireless connectivity for all wireless device communication & cloud communication with wireless connectivity, Current transformer to be installed in pump house with following accessories listed below: Micro Processor Unit shall have control, protection & live data | |||||
| 1.01 | devices up to 6 Pumps 10 Sensor Micro Processor Fast Fourier transformation to eliminate harmonics &, Surges True RMS measurements & simultaneous sampling of Volts, Amps 2 layer protection & each 1/0 controller protected with a single form factor for multiple technologies high performance & accuracy with real time clock wireless connectivity compatible,data backup, various functions high Speed mode with instant switches from one input to the other & can be controlled in slot for memory with conncoted to external devices like android/os/windows platform & Pe through software key - CGPS plug - in software. Software key should comprised of UDP/ FTP/HTTP open standard Internal Expansion Wireless CPUR: with an core ARM7 32- bit foating point (72 MIZ max) microprocessor, with integrated IDE & GPRS connection with Uptime - Minimum 95%, Download Speed up to -4 Mbps Transter unlimited of all measured parameters/ quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. - 1 No. | 1 | Job | - | - |
| 2 | Supplying installation testing & commissioning of Ultrasonic Sensor status of water tank output analog approx. liquid Quantity in tank, made of ABS housing, detection range not less than 2 meters, output analog approx, liquid quantity in Tank, etc. complete as required | 8 | Job | - | - |
| 3 | Supplying, installation, testing & commissioning of microprocessor, suitable with control & wireless connectivity device transmitter and receiver (To be installed nearby sensor & line pressure transmitters for wireless data Range upto 1000 meters i/c sending data from upward to downward) for sending status of water tank to Master Microprocessor unit of on real time basis, for sending/receiving data from SCADA. Made of ABS Housing, Control :- Relay Based output & Display at 50 Level Water in tank indicator with suitable control panel operated at SPMCB 6 AMP. 230V single phase 50 Hz AC supply etc. complete as required. | 3 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
BOQ_384608.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .