Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC DOOR NO 42 2237 KRISHNA BEHIND ERNAKULAM MEDICAL CENTRE CENTURY CLUB ROAD VENNALA KOCHI 682028 | KOCHI | ERNAKULAM | KERALA | 682028 | ₹38.5 L Quoted ₹40.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹44.3 LRejected-AOC 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹44.3 L | L2 | Rejected-AOC L2 |
| 3 | L3₹44.5 LRejected-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹44.5 L | L3 | Rejected-AOC L3 |
| 4 | L4₹51.4 LRejected-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | ₹51.4 L | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | T.I.John and Sons L2 | AAG INDIA PVT LTD L1 | K.V.GEORGE AND COMPANY L4 | ELAN ENGINEERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of addressable fire alarm system (Make : Honywell ) installed at Sanjivani Hosptal including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device with air blower, replacement of defective spares / components, comprising of following all as specified and directed:
(a) Microprocessor based control Panel 6 Loop - 01 No.
(b) Multi Sensor - 703 Nos.
(c) Fire alarm hooters - 50 Nos.
(d) Manual call points - 51 Nos.
(e) Repeater Panels - 6 Nos.
(f) Heat detecter - 18 Nos.
(g) 12 AH Battery - 02 Nos.
(h) Response Indicator - 120 Nos.
(i) Electronic siren - 01 No
(j) Isolator modules - 40 Nos
Note for item Nos 1 to 34
(a) Contractor shall employed experienced trained and certified Engineer in Fire Alarm system for supervising and execution of work during the contract period and all certificates should be submitted before the commencement of work.
(b) Contractor Shall Maintain all the Documents and Produce to the concerned Engineer in charge as and when required /preparation of RAR
(c) Contractor shall give the Demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the Same
(d) Spares required for replacement shall be measured and paid seperately as 'Supply only' under respective items.
(e) Contractor shall arrange all T&P ladders, scuffoldings if need up to any height of building for the cleaning and fault rectifying of sensors, any type fire detectors modules and equipments. The unit rate quoted is deemed to be included for the Same
(f) Testing of functionality of Fire Alarm System in quarterly or as and when directed by Engr- in-Charge by random check of devices by artificial smoke and other testing measures in any type of building shall be inclded in the quoted rate.
(g) Any faults should be attend and and rectified within 24 Hours after recieving comlaints, otherwise penalty of Rs 500/- per day will be penalised for each complaint (h) Make of the materials replacing against supply only in the schedule should be as per the existing make at site. | 4 | Each Job | 3,500 ₹14,000 | 4,320 ₹17,280 | 5,000 ₹20,000 | 4,000 ₹16,000 |
| 2.00 | All as per item No 1 here-in-before, ( Make : GST) but comprising of following installed at NIETT. .
(a) Microprocessor based control Panel 2 Loop - 01 No.
(b) Mulit Sensor detector - 150 Nos.
(c) Fire alarm hooters - 12 Nos.
(d) Manual call Points - 12 Nos.
(e) Isolator module - 60 Nos.
(f) Response Indicator - 40 Nos.
(g) Heat detector - 05 Nos.
(h) Repeater Panel - 01 No
(i) 7 AH Battery - 02 Nos.
(j) Sprinkler bulb -150 Nos | 4 | Each Job | 2,000 ₹8,000 | 2,160 ₹8,640 | 3,500 ₹14,000 | 2,000 ₹8,000 |
| 3.00 | All as per item No 1 here-in-before, (Make- Edward & Seimens) but comprising of following installed at ND school. .
(a) Microprocessor based control Panel 1 Loop - 02 Nos.
(b) Repeater Panel - 02 Nos.
(c) Multi sensor detectors - 140 Nos.
(d) Fire alarm hooter / Sounder cum Beacon - 19 Nos.
(e) Manual call points -13 Nos.
(f) Heat detecters - 6 Nos.
(g) 7 AH Battery - 02 Nos.
(h) Isolator - 04 Nos (i) 24AH 12V Smf Lead acid battery - 02 Nos | 4 | Each Job | 2,500 ₹10,000 | 2,160 ₹8,640 | 3,500 ₹14,000 | 2,000 ₹8,000 |
| 4.00 | All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at Sagarika. .
(a) Adreesable control Panel 1 Loop - 01 No.
(b) Mulit Sensor detector - 140 Nos
(c) Fire alarm hooters - 01 Nos
(d) Manual call Points - 10 Nos
(e) Isolator module - 05 Nos
(f) Beam flame detector - 06 Nos -
(g) Repeater Panel - 01 Nos
(h) 7 AH Battery - 02 Nos
(i) LED Exit Signage - 05 Nos | 4 | Each Job | 2,500 ₹10,000 | 2,160 ₹8,640 | 3,000 ₹12,000 | 2,000 ₹8,000 |
| 5.00 | All as per item No 1 here-in-before, ( Make : Honeywell Firelite) but comprising of following installed at Parikshit Bldg .
(a) Microprocessor based control Panel 2 Loop - 01 No.
(b) Fire alarm hooters - 09 Nos
(c) Manual call Points - 18 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
| 6.00 | All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Vishal Bldg .
(a) Microprocessor based control Panel 1 Loop - 01 No.
(b) Fire alarm hooters - 24 Nos
(c) Manual call Points - 24 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
| 7.00 | All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Viduit Bldg .
(a) Microprocessor based control Panel 1 Loop - 01 No.
(b) Fire alarm hooters - 08 Nos
(c) Manual call Points - 08 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
| 8.00 | All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Sahadev Bldg .
(a) Microprocessor based control Panel 2 Loop - 01 No.
(b) Fire alarm hooters - 10 Nos
(c) Manual call Points - 10 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
| 9.00 | All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Bhishma Bldg .
(a) Microprocessor based control Panel 1 Loop - 01 No.
(b) Fire alarm hooters - 08 Nos
(c) Manual call Points - 16 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
| 10.00 | All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Vikramadithya Bldg .
(a) Microprocessor based control Panel 1 Loop - 01 No.
(b) Fire alarm hooters - 24 Nos
(c) Manual call Points - 24 Nos
(d) 7 AH Battery - 02 Nos | 4 | Each Job | 1,000 ₹4,000 | 1,440 ₹5,760 | 1,700 ₹6,800 | 1,300 ₹5,200 |
Tender Value
Refer Docs
EMD Value
₹99,900
Closing Date
11 Aug 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR /MAINT OF FIRE FIGHTING FIRE ALARM AND DETECTION SPRINKLE, GAS SUPPRESSION SYSTEMS AT INHS SANJIVANI AND NAVAL BASE KOCHI
2025_MES_719673_1
8538/E8
Open Tender
Electrical and Maintenance Works
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹99,900
Yes
11 Feb 2026
10 Jul 2025
13 Aug 2025
10 Jul 2025
11 Aug 2025
27 Jul 2025
10 Jul 2025 - 11 Jul 2025
Amount
All as per item No 1 here-in-before, ( Make : GST) but comprising of following installed at NIETT. . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Mulit Sensor detector - 150 Nos. (c) Fire alarm hooters - 12 Nos. (d) Manual call Points - 12 Nos. (e) Isolator module - 60 Nos. (f) Response Indicator - 40 Nos. (g) Heat detector - 05 Nos. (h) Repeater Panel - 01 No (i) 7 AH Battery - 02 Nos. (j) Sprinkler bulb -150 Nos
All as per item No 1 here-in-before, (Make- Edward & Seimens) but comprising of following installed at ND school. . (a) Microprocessor based control Panel 1 Loop - 02 Nos. (b) Repeater Panel - 02 Nos. (c) Multi sensor detectors - 140 Nos. (d) Fire alarm hooter / Sounder cum Beacon - 19 Nos. (e) Manual call points -13 Nos. (f) Heat detecters - 6 Nos. (g) 7 AH Battery - 02 Nos. (h) Isolator - 04 Nos (i) 24AH 12V Smf Lead acid battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at Sagarika. . (a) Adreesable control Panel 1 Loop - 01 No. (b) Mulit Sensor detector - 140 Nos (c) Fire alarm hooters - 01 Nos (d) Manual call Points - 10 Nos (e) Isolator module - 05 Nos (f) Beam flame detector - 06 Nos - (g) Repeater Panel - 01 Nos (h) 7 AH Battery - 02 Nos (i) LED Exit Signage - 05 Nos
All as per item No 1 here-in-before, ( Make : Honeywell Firelite) but comprising of following installed at Parikshit Bldg . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Fire alarm hooters - 09 Nos (c) Manual call Points - 18 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Vishal Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 24 Nos (c) Manual call Points - 24 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Viduit Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 08 Nos (c) Manual call Points - 08 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Sahadev Bldg . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Fire alarm hooters - 10 Nos (c) Manual call Points - 10 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Bhishma Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 08 Nos (c) Manual call Points - 16 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Vikramadithya Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 24 Nos (c) Manual call Points - 24 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Edward EST ) but comprising of following installed at MOC Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Detectors - 51 Nos (b) Fire alarm hooters - 02Nos (c) Manual call Points - 10 Nos (d) isolator module - 02 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at NIAT P-172 Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repaeter panel - 01 No (c) Detectors - 67 Nos (d) Fire alarm hooters - 6 Nos (e) Manual call Points - 4 Nos (f) Relay module - 6 Nos (g) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at Vinash Bldg . (a) Microprocessor based control Panel 4 Loop - 01 No. (b) Repaeter panel - 01 No (c) Detectors - 248 Nos (d) Fire alarm hooters - 36 Nos (e) Manual call Points - 36 Nos (f) 7 AH Battery - 02 Nos (d)
All as per item No 1 here-in-before, ( Make : Ravel ) but comprising of following installed at Rajput Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel -01 No (c) Fire alarm hooters - 06 Nos (d) Manual call Points - 12 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Siemens ) but comprising of following installed at Vipul Bldg . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater Panel -01 No (c) Fire alarm hooters - 12 Nos (d) Manual call Points - 12 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Yudhishtiral Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel -01 No (c) Fire alarm hooters - 10 Nos (d) Manual call Points - 20 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Ekchakra Bldg . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater Panel -01 No (c) Fire alarm hooters - 08 Nos (d) Manual call Points - 16 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Ekalavya Bldg . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater Panel -01 No (c) Fire alarm hooters - 10 Nos (d) Manual call Points - 20 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Bharat Bldg . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 9 Nos (c) Manual call Points - 18 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Balram Bldg . (a) Microprocessor based control Panel 4 Loop - 01 No. (b) Fire alarm hooters - 9 Nos (c) Manual call Points - 13 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell ) but comprising of following installed at Vijeta Bldg . (a) Microprocessor based control Panel 4 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 16Nos (d) Manual call Points - 16 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Siemens ) but comprising of following installed at NOIC Bldg . (a) Microprocessor based control Panel 5 Loop - 01 No. (b) Multi Detector - 140 Nos (c) Repeater Panel - 01 No (d) Fire alarm hooters - 09 Nos (e) Manual call Points - 26 Nos (f) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Siemens ) but comprising of following installed at Boat Repair Bay COY Complex . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Multi sensor Detector - 32Nos (c) Heat detector -12 Nos (d) Repeater Panel - 01 No (e) Fire alarm hooters - 12 Nos (f) Manual call Points - 12 Nos (g) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Siemens ) but comprising of following installed at Meghnath 1 . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 28Nos (d) Manual call Points - 14 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Siemens ) but comprising of following installed at Meghnath 2 . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 14 Nos (d) Manual call Points - 14 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Ravel ) but comprising of following installed at Meghnath 3 . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 14 Nos (d) Manual call Points - 14 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at Meghnath 4 . (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 10 Nos (d) Manual call Points - 10 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Ravel ) but comprising of following installed at Meghnath 5 . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 14 Nos (d) Manual call Points - 14 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at Signal School P-22 . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No (c) Fire alarm hooters - 14 Nos (d) Manual call Points - 14 Nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at NAI KOCHI . (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 8 Nos (c) Manual call Points - 8 Nos (d) Smoke & Heat sensor detector - 82 nos (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Honeywell) but comprising of following installed at P8I NIAT (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Fire alarm hooters - 7 Nos (c) Manual call Points - 7 Nos (d) Smoke & Heat sensor detector - 81 nos (e) Repeater panel - 01 No (f) 7 AH Battery - 02 Nos (g) 4 Zone gas releasing panel - 01 No (h) Photo electric type smoke detector - 03 Nos (j) Heat Detector - 03 Nos Comprehensive maintenance for GAS SUPPRESSION SYSTEM:- (i) Includes checking of Gas Suppression System during site visit, once in every three months. (ii) General checking and simulation of suppresion system using spar cylinders. (iii)Checking of discharge lines, working of electromagnetic devices / solenoid valves, directional valves, nozzels, gauges etc, and cleaning of components etc. (iv)General servicing of Manual release switches, abort switches etc include cleaning, checking etc. (v)General servicing of Gas release Panel and device including cleaning, checking.
All as per item No 1 here-in-before, ( Make : Siemens) but comprising of following installed at Vibhuti bldg (a) Microprocessor based control Panel 5 Loop - 01 No. (b) Fire alarm hooters - 37 Nos (c) Manual call Points - 37 Nos (d) Repeater panel - 01 No (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Ravel) but comprising of following installed at Bhim Bldg (a) Microprocessor based control Panel 8 zone - 01 No. (b) Fire alarm hooters - 24 Nos (c) Manual call Points - 06 Nos (d) 7 AH Battery - 02 Nos
All as per item No 1 here-in-before, ( Make : Ravel) but comprising of following installed at Balram (a) Microprocessor based control Panel 1 loop - 01 No. (b) Fire alarm hooters - 09 Nos (c) Manual call Points - 18 Nos (d) Repeater panel - 01 No (e) 7 AH Battery - 02 Nos
All as per item No 1 here-in-above, ( Make : siemens) but comprising of following installed at Signal school (a) Fire alarm Panel 1 loop - 01 No. (b) Hooters - 01 Nos (c) Manual call Points - 01 Nos (d) Smoke Detector - 13 No (e) Remote response indicator - 06 Nos (f) 7 AH Battery - 02 Nos l
Material and labour for attending of breakdown in Fire Fighting System at INHS Sanjivani and Naval Base detection of nature of defect including carry out minor repairs, loose connection , change of small length of wire as required size to make the machine/equipment functional ,opening of switch board / panel board and refixing the same after necessary repair, etc complete all as specified and directed.
Note:- (a) The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the machine functional for minor repair. If replacements of parts / items is required to make the equipment/machine functional the cost of labour and material for the same shall be measured and paid for as " Supply and fixed in repairs/Material and labour in repairs " under relevant items of this schedule here in after and in that case this item shall not be measured.
(c) If breakdown shall not be attended & rectified the same day as recived by the contrcator except rewinding of Motor and other major spares as specified , the recovery will be made @ Rs.1000/- per breakdown per day. And after 15 days of nonfunctional of any machine as specified for any reason the recovery will be made @ Rs. 2000/- per day till the machine operational.
Supply and fixed in repair S/S fire hydrant 63 mm dia, single headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair S/S fire hydrant 63 mm dia, double headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair S/S female coupling 63mm dia for hydrant valve ISI makred including taking ddown old unserviceable one complete all as specified and directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair first aid hose reel, wall mounted swinging type complete with drum, bracket, globe valve/ stop cock of size 19 mm dia, 30 mtr long high pressure hose reel tubing with branch pipe PVC shut off nozzle including taking down unserviceable old one , complete all as specified and directed. Note :- Hose reell shall be as per IS 884 and hose tubing as per IS 8090 ; Make : Newage / Essel/ Ever safe
Supply and fix in repair first aid hose reel nozzle valve PVC type of size 19 mm complete all as specified and directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair 15 Mtr long rubber lined woven jacketed hose pipe 63 mm dia, type A (Reinforced rubber lined) as per IS 636 with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with S/S male and female coupling conforming to IS 903 complete all as specified and directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair 30 Mtr long rubber lined woven jacketed hose pipe 63 mm dia, type A (Reinforced rubber lined) as per IS 636 with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with S/S male and female coupling conforming to IS 903 all as specified and as directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair fabricated MS hose cabinet, made of 18 gauge MS sheet 800mm X 600mm X 250mm double door with 3 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side brilliant white inside and including taking down unserviceable old one , complete all as specified and directed.
Supply and fixed in repair 3 mm thick glass of suitable size for MS hose box standard size including taking down unserviceable old onecomplete all as specified and directed.
Supply and fixed in repair 63 mm dia S/S branch pipe instantaneous inlet and made 15 mm bore nozzle short complete all as specified and directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair Fire brigade inlet connection 63mm dia 4 way valve ISI marked including taking down unserviceable old one , all as specified and as directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair Fire brigade inlet connection 63mm dia 2 way valve ISI marked including taking down unserviceable old one , complete all as specified and directed. Make : Newage / Essel/ Ever safe
Supply and fixed in repair of Pressure switch Universal type all as speficied and directed. Make: Danfoss/ Indfoss/ Honey well
Supply and fixed in repair of Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as spcified and directed. Make : H Guru / Baumer / Mass
Supply and fixed in repair of Air Cushioning Tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, nipple tees elbows and all accessories complete all as specified.
Supply and fixed in repair of 3 phase starter for pump set 5 to 20 HP capacity complete all as specified and directed. Make : L& T / Havells / C&S
Supply and fixed in repair of 3 phase starter for pump set 5 HP capacity. Make : L& T / Havells / C&S
Supply and fixed in repair of single phase starter for pump set up to 5 HP capacity. Make : L& T / Havells / C&S
Supply and fixed in repair of 1000 litres capacity ISI marked Rotational Moulded polyethylene water stroge tank (cylinderical Vertical with Close top ) hosisted and fixed in position complete all as specified and directed Make: Aqua Tech/ Sintex
Supply and fixed in repair of 150mm bore of Cast Iron, butter fly valve , complete all as specified and directed. Make : AUDCO/ C&R/ INTERVALE/ KARTAR
Supply and fixed in repair 100mm bore of Cast Iron, butter fly valve , complete all as specified and directed. Make : AUDCO/ C&R/ INTERVALE/ KARTAR
Supply and fixed in repair 150mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as specified and directed. Make : Kirloskar/ BIR/ Leader /KARTAR
Supply and fixed in repair 100mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as specified and directed. Make : Kirloskar/ BIR/ Leader /KARTAR
Supply and fixed in repair 80mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as specified and directed. Make : Kirloskar/ BIR/ Leader /KARTAR
Supply and fixed in repair 150 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair of 100 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair of 80 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 150mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubedall as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 100mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubedall as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 80mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubed. all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 50mm gun metal, gate valve with iron wheel head, screwed both ends for iron pipe including taking down unserviceable old one complete all as specified and directed. Make: Sankti / NVI/ ZeW/ Attom
Supply and fixed in repair 150mm DI Swing type wafer Check valve including taking down from the suction side of pumpset from the sump and making good the distrubed all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 100mm DI Swing type wafer Check valve including taking down from the suction side of pumpset from the sump and making good the distrubed all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 80 mm DI Swing type wafer Check valve including taking down from the suction side of pumpset from the sump and making good the distrubed all as specified and directed Make : AUDCO/ C& R/ INTERVALE/ KARTAR
Supply and fixed in repair 50mm gun metal, gate valve with iron wheel head, screwed both ends for iron pipe including taking down unserviceable old one complete all as specified and directed. Make: Sankti / NVI/ ZeW/ Attom
Supply and fixed in repair of three pole power contactor suitable for main pumpset of capacity 70 HP to 120 HP for Main pumpset all as specfied and as directed . Make: L&T / ABB/ GE
Supply and fixed in repair of three pole power contactor suitable for main pumpset of capacity 45 HP to 68 HP all as specified and as directed. Make: L&T / ABB/ GE
Supply and fixed in repair of three pole power contactor suitable for jocky pumpset of capacity 25 HP to 40 HP for pumpset all as specfied and as directed . Make: L&T / ABB/ GE
Supply and fixed in repair of three pole power contactor suitable for jocky pumpset of capacity 05 HP to 20 HP for pumpset all as specfied and as directed . Make: L&T / ABB/ GE
Supply and fixed in repair Electronic timer for control panal any type all as specified and directed. Make: L&T / ABB/ GE
Supply and fixed in repair of Push button with indicator ( set of three R Y B ) for panels all as specified and directed. Make: L&T / ABB/ GE
Supply and fixed in repair control unit for12/24 Volt 10 Amps automatic Battery charger control unit with provision of auto cut and preventing over charging and short circuit protection for firefighting LT control panel complete all as specified and as directed . Make: As per existing
Supply and fixed in repair 12 Volt 130/150 AH Battery for Diesel Pump set, complete all as specified and directed. Make: Cummins/ Exide/ Amaron
Supply and fixed in repair of CPVC pipe inner diameter 100 mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, complete all as specified and directed. Make: Supreame/ Astral/ Finolex
All as per Item No 80 here-in-before, but 75 mm dia complete all as specified and directed.
Supply and fixed in repair Ductile Iron Pipes 150mm bore centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , complete all as specified and directed. Make: Sree Pipes/Jindal/ Kejriwal
All as per item No 82 here-in-before , but of 100mm bore complete all as specified and directed. .
Supply and fixed in repair 150 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , complete all as specified and directed. Make: Make: Sree Pipes/Jindal/ Kejriwal
All as per item No 84 here-in-before , but of 100mm bore.complete all as specified and directed. .
All as per item No 84 here-in-before , but of 80mm bore complete all as specified and directed.
Supply & fix in repair DI fittings (pressure class K-9) such as bends, (any type, radius and angle), Tapers any type (straight bend, increasing, decreasing or double socket etc) Tee piece single branch "Y" junction double branch, cross (all socket or socket and spigot) collars, caps and plugs of size upto 150mm bore confirming to IS 9523-2000 including taking down unserviceable old one , complete all as specified and directed.
Material and labour in repair for Framed / Fabrication work , such as Valve chamber covers, Static Tank Cover, Base frames for pumpsets , Protection covers for Pumpsets / Panel Boards, Staging for Water tanks, ladders, etc complete all as specified and directed.
Material and labour in repair for 150mm bore C I pipes with flanged end, centrifugaly cast, class "A" in any length, laid in trenches including taking down old unserviceable one, complete all as specified and directed. Make: Jindal/ Tata
All as per item No 89 here-in-before, but of 100 mm size complete all as specified and directed.
Material and labour in repair for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed of capacity 120 HP complete all as specified and directed.
All as per item No 91 here-in-before, but of capacity 100 HP complete complete all as specified and directed.
All as per item No 91 here-in-before, but of capacity 75 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 60 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 90 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 40 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 20 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 10 to 15 HP complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 20 HP Submersible Pump complete all as specified and directed..
All as per item No 91 here-in-before, but of capacity 5 HP Submersible Pump complete all as specified and directed..
Material and labour in repair Cast Iron Fittings upto 150mm dia such as bends (cany type, radius and angle), tappers any type (straight, bend, increasing or double socket etc) tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including taking down unserviceable old one complete all as specified and directed.
Material and labour for servicing of cast iron sluice valve of 150 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
All as per item No 102 here-in-before, but of 100 mm size.complete all as specified and directed.
All as per item No 102 here-in-before, but of 80 mm size complete all as specified and directed.
Material and labour in repair for carry out General Servicing and Maintenance to diesel engine driven pump / fuel ijection pump of capacity 100/ HP including B check and service as per manufactures recommendation ,overhauling including repalcement of oil filter ,air filter ,gland packing ,diesel filter with replace ment of O rings ,Engine Oil and toping up of Coolant up to required level, battery checkup and top up of distilled water etc which ever be required to making 100 % serviceabiltiy of the engine complete all as specified and as directed .
All as per item No 105 here-in-before, but of capacity 85 HP complete all as specified and directed..
All as per item No 105 here-in-before, but of capacity 75/76 HP complete all as specified and directed..
All as per item No 105 here-in-before, but of capacity 60 to 68 HP complete all as specified and directed..
All as per item No 105 here-in-before, but of capacity 50 to 58 HP complete all as specified and directed..
All as per item No 105 here-in-before, but of capacity 16 HP complete all as specified and directed..
Material and labour in repair for diconnecting suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump from motor and opening the pump , cleaning , replacing the worn out part like - oil seal, mechanical seal, ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor 120 HP capacity and installed at site as per existing including testing after complete repairs of work all as specified and directed
All as per item No 111 here-in-before, but of capacity 100 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 75 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 60 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 50 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 40 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 20 HP complete all as specified and directed..
All as per item No 111 here-in-before, but of capacity 10 to 15 HP complete all as specified and directed..
Material and labour in repair for relay card for control panel of Diesel driven pump complete all as specified and directed.
Material and labour in repair for disconnecting the three phase electric supply from panel board and taking out the burned wiring of panel board and unserviceable spare part like contactor ,relays, timer , push botton, NO/NC volts coil and thermal load relays etc and re-wring the panel board with new required size of wire and acessories which be required to make 100 % serviceability suitable for starter panel for pump sets complete all as specified and directed.
Excavation in trenches not exceeding 1.5 M wide and n.exc.1.5m in depth for laying pipes etc and getting out in soft/loose soil complete all as specified and directed.
Returning / filling in soil, including spreading, leveling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated materials(soil) to a distance not exc 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Material and labour for taking up and relaying of existing DI pipe line in trenches with all fittings after cleaning thoroughly and remove all blockages and leakages after replacing gaskets and necessary nut and bolts and testing of pipe line size upto 150 mm bore complete all as specified and directed.
Material and labour, plain cement concrete (1:3:6) type C2 using 40mm graded stone aggregate as in foundations/road cutting filling and mass concrete complete all as specified and as directed.
Material and labour for cutting of existing road/hardstanding/ concrete block/rcc slab /brick work or stone masonary of any type by using necessary tools upto 30 cm depth for laying of water pipe including making good surface by returning filling ramming of road bond ready mix bituminous over 200 mm hardcore of broken stones. complete all as specified and directed
Material and labour for Painting to outer side of the existing feeder pillar board and pipe lines inside fire fighting installation by two coat of synthetic enamelled paint including prepration of old painted suface complete all as specified and directed. Make:Asian panits/ Shalimar/ Nerolac
All as per item No 128 here-in-before, but painting of pump set of any size complete all as specified and directed..
All as per item No 128 here-in-before, but painting of hose box complete all as specified and directed..
All as per item No 128 here-in-before, but painting of yard hydrant/Fire brigade point complete all as specified and directed.
All as per item No 128 here-in-before, but painting of fire fighting system pipe line of size mentioned here-in-after complete all as specified and as directed.
Material and labour in repair of worn out Gland Packing of pump set / sluice valves / hydrants any make / metal / size including washers of any shape / size to avoid water leakage as indicated including taking out old one complete all as specified and directed.
Material and labour in repair for Reprograming of Existing fire alarm system installed at Various Locatioin including loope Checking, Changing of Device Location Name and Address of the Room and preparing as build Drawing all as specified and directed.
Material and labour for cleaning of Strainer in any situation of size of 3 mtr long X 0.40 mtr dia fabricated with aluminium stainer to suction line having 1200 holes to the strainer of suction line includes dismantling the suction line and lifting it , cleaning the foot valve , scrubbing the complete stainer including 1200 holes with suitable liquid properly and than lowering back for refixing the stainer into sea water with MS angle arms and 02 hooks provided to the strainer for lifting/ lowering the strainer to the suction line and to the pump set alongwith foot valve inside the lowered stainer complete all as specified and directed.
Material and labour in repair for Cleaning of Foot valve of size 80 mm to 150 mm in any condition including dismantling the suction line from pump and lifting it and lowering back after cleaning the foot valve complete all as specified and directed.
Supply and fixed in repair Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed. Make: Note Fier/Honey Well / Edwards/ Siemens/ GST/ EST/Cooper/Ravel
All ae per item 137 herein before, but 2 loop complete all as specified and directed.
Supply and fix in replacement of addressable Fire alarm control panel Power supply unit (SMPS) for the fire alarm panel combatible as per existing make & model complete all as specified and as directed.
Supply and fixed in repair Active Repeater Panel with 320 Alpha numeric Characters on LCD display/ or Touch Screen LCD. Networkable with all functionality of Main Panel having Reset / Alarm Silence and Acknowledgement Buttons . Approval Standards : UL/ VdS / EN54/ FM complete all as specified and directed. Make: Note Fier/Honey Well / Edwards/ Siemens/ GST/ EST
Supply and fixed in repair addressable type multi sensor detector with smoke & Heat combination complete all as specified and directed . Make: Edwards/ GST/ EST/Honey Well/ Morley/ Siemens/ Bosch/ Cooper/Ravel
Supply and fixed in repair addressable Sounder cum- storb complete all as specified and directed. Make: Edwards/ GST/ EST/Honey Well/ Morley/ Siemens/ Bosch/ Cooper/Ravel
Supply and fixed in repair addressable remote response indicators complete all as specified and directed. Make: Edwards/ GST/ EST/Honey Well/ Morley/ Siemens/ Bosch/ Cooper/Ravel
Supply and fixed in repair addressable Manual call point resettable type complete all as specified and directed. Make: Edwards/ GST/ EST/Honey Well/ Morley/ Siemens/ Bosch/ Cooper/Ravel
Supply and fixed in repair addressable Monitor module complete all as specified and directed. Make: Edwards/ GST/ EST/Honey Well/ Morley/ Siemens/ Bosch/ Cooper/Ravel
Supply and fixed in repair Sprinkler Bulb, 20mm dia, quick response with extended covereage type 57 degree Celsius Pendent / Side wall Type complete all as specified and directed.
Supply and fixed in repair addressable type heat detector with base, rate of temperature rise as per IS-2175 complete all as specified and directed. Make: Edwards/Honey Well/ Morley/ Siemens
Supply and fixed in repair addressable short circuit isolator complete all as specified and directed. Make: Edwards/Honey Well/ Morley/ Siemens
Supply and fixed in repair UV/ IR flame detector tripple layer complete all as specified and directed. Make: Edwards/Honey Well/ Morley/ Siemens
Supply and fixed in repair beam master detector complete all as specified and directed. Make: Edwards/Honey Well/ Morley/ Siemens
Supply and fixed in repair 12 V 7/12AH Battery complete all as specified and directed. Make: Exide/ Amaron/ Pansonic
Supply and fixed in repair manual call point protection cover including taking down unserviceable old one complete all as specified and directed.
Supply and fixed in repair manual call point glass including taking down unserviceable old one complete all as specified and directed.
Supply and fixed in repair 2 core1.5 sq mm armoured XLPE FRLS multi stranded copper conductor cable in replacement of old fire cable required in any height or in wall/ceiling of building includind removing of old cable with or without conduit complete all as specified and directed. (for INHS Sanjivani) Make: Havells/ Polycab/ Phinolex
Supply and fix Loop card for Fire alarm control panel combatible as per existing any make & model complete all as specified and directed.
Supply and fixed Fire alarm adressable panel display with CPU any make any model of Fire alarm panel combatible as per existing make & model complete all as specified and as directed.
Supply and fixed in replacement of Protection device for Fire alarm panel LCD display of micro controller based electronic device of low/high voltage cutt off and protection with stabilised voltage with single switch operation facility of delay time for ON both 24 Volt 10 Amps 230 Volt 1.5 KVA
Supply and fixed in replacement of addressable Fire alarm control panel mother bord for the fire alarm panel combatible as per existing make & model complete all as specified and as directed.
Supply and fixed in repair level switch for self priming pump upto 2 HP capacity for auto ON/OFF operation complete all as specified and directed. Make : As per existing
Material and labour in repair for damaged radiator from the engine and taking out for welding and repairing in workshop cleaning and refixing with all the acessories which be required to make 100 % serviceability suitable for diesel driven pump set of any make and any capacity complete all as specified and directed.
Material and labour for self priming pump 1.5 HP three phase for priming of Fire pumps complete all as specified and directed.
Material and labour for self priming pump 1 HP Single Phase for priming of Fire pumps complete all as specified and directed.
Material and labour for distilled water for battery complete all as specified and directed.
Supply and fix in repair of wall/ceiling mounted LED emergency exit signage luminaire complete all as specified and directed. Make: Crompton Greaves/ Wipro/Havells/Philips
Material and labour for coolant for diesel engine radiator complete all as specified and directed.
T.I.John and Sons (BID ID -3376954)
ELAN ENGINEERS (BID ID -3384750)
K.V.GEORGE AND COMPANY (BID ID -3389597)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid