Executive Engineer, panchayat, R & B Division, Surat.
NOTIFIED / 2024-25 Providing with Sound proof kit, Lighting along with Central AC work in Banquet Hall at Mora , Taluka Choryasi, Dist Surat.
328715
06 OF 2026-27
Open
Civil Works - Others
Works
Surat
5 documents required · 5 mandatory
₹3,600
Executive Engineer, panchayat R & B Division, surat
₹1.5 L
29 Jul 2026
29 Jul 2026
29 Jul 2026
11 Aug 2026
29 Jul 2026
270 days
Name of work:- Providing with Sound proof kit, Lighting along with Central AC work in
Banquet Hall at Mora , Taluka Chorasi, Dist Surat.
: : 'BILL OF QUANTITY : :
Estimated Estimate Total amount
Estimated Estimate Total amount
Sr. No. Quantity Item of work Rate Unit according to
but may In figures estimated
1 469.27 WOODEN PANELLING 2435.11 SQ.MT.
Providing and making of panelling on Wall & columns
using 12mm ply, aluminium pipe for (2" x 2") framing,
Ghana bidding patti (11/2" x 3/4") including all
material, labour and hardware complete,including
mmx 3mm groove (if shown) with all materials,polish
work,beading patti, labour, lead and wastage etc.
complete. And Finished with different materials,
termite treatment on plywoods and complete the work
satisfactorily as per instruction of architect or
Engineer-in charge.
2 589.27 HDF FINISH 778.71 SQ.MT.
Providing and fitting of 4mm waterproof HDF sheet
(as per drawing) on ply partition including all material,
labour and hardware, waste of materials.Complete
the work satisfactorily as per instruction of architect or
Engineer-in charge.
3 589.27 LAMINATE FINISH 1354.20 SQ.MT.
Providing and fitting of 1 mm laminate (as per drawing
& selection) on ply partition all material,
adhesives,labour and hardware, waste of materials
complete as per instruction of architect.[Basic Rate of
Laminate : 2000rs./sheet (8' x 4')] 3 mmx 3mm
groove (if shown) with all materials,polish
work,beading patti, labour, lead and wastage etc.
complete. And Finished with different materials,and
complete the work satisfactorily as per instruction of
architect or Engineer-in charge.
4 85.84 GYPSUM CEILING 874.66 SQ.MT.
Pro. And fixing single layer water proof gypsum board
12.5 mm thick sections using water proof board of size
1220 mm x 1830 mm x 8.0 mm suspended by GI
suspender channel of size 25 mm x 3 mm with
intermediate channel og size 18 mm x 40 mm x
at 1220 mm center to center ceiling section of size
mm x 35 mm x 0.55 mm at 457 mm c/c and perimeter
channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm
edges & drops incl.paper tap sand sofit cleat, anchor
fastener, scoch bolt connecting cleat,joining
top coat on ceiling incl.making necy.opening for light
fitting,diffuser etc. comp. as per detail drawing as
5 4.00 GLASS DOORS 33658.40 No
Providing and fixing Glass door of approx size
MT. x 2.4 MT.. using 12 mm toughned glass door with
filmwork & H Type Handle 32MM X 457MM & floor
spring of brand ,ozone,dorma,pag etc AS PER
DRAWING including all acceessories,locks, material,
silicone,labour,installation, Hole & slote charges etc.
and complete the work satisfactorily as per instruction
of architect or Engineer-in charge.
6 6.72 GLASS PARTITION WITH FILMWORK 3748.11 SQ.MT.
Providing and fixing of full height glass partitions (AS
PER DRAWINGS) using patch fittings /aluminium
glass profiles as selected, U-channels,12mm clear
toughned glass, film work as PER drawing including
all hardware item with all material, labour, lead and
wastage etc. and complete the work satisfactorily as
per instruction of architect or Engineer-in charge.
7 12.00 GLASS RAILING 7070.00 RMT
Providing and fixing 12 mm thick and 1200 mm
highted toughened glass railing with 50 mm ss
grade OR 4 MM TK with 50 mm dia aluminium hand
rail,dyecasted aluminium u shape box bottom rail as
per selection, and ,including all fastners and floor
profiles or d brackets,glass frosting work as As per
8 19.20 WOODEN BLINDS 3749.12 SQ.MT.
Providing and fixing of approved quality wooden
vanishing blinds 50 mm wide slit of brand signature -
essential series, with easy lift cord/chain operation,
including all acceessories, material, labour,installation
etc. and complete the work satisfactorily as per
instruction of architect or Engineer-in charge.
9 6.00 MAIN DOOR WITH LAMINATE FINISH WITH DOOR 28348.68 NOS
Providing and fitting of heavy duty conceal door closer
( ENOX ITS-3870-EN 2-5) (as per drawing &
selection) on existing flush door as per selection,s per
instructions etc waste of materials, and complete the
work satisfactorily as per instruction of architect or
Engineer-in charge.
10 34.43 GRANAMITE SLAB DOOR & WINDOW FRAME 4741.95 SQMT
Providing and laying 15mm thick granamite slab slab
of 800 x 3000 SPACE GREY in Risers of steps /
Dedo , landing & jamb/seal of door window laid on a
bed of 12mm thick Adhesive chemical of roff T-05
Category(Roff Vitrofix Ultra Adhesive is a highly
polymer modified,thin-set tile adhesive) and finishing
with flush pointing incl. rounding the outer edge,
moulding,polishing etc. and complete the work
satisfactorily as per instruction of architect or
Engineer-in charge.
11 24.00 ALLUMINIUM WINDOW 10605.00 SQMT
Providing and fixing Telesia made Window section
formate TS-22, of 2 track shutter AS PER
DRAWINGS with interlocking of section 58 x
mm track with weight 1.3 kg/rn mt,shutter of size
66.91 x.28.00 mm with weight 1.4 kg/rn mt, and
interlocking of 40.90 x 22.50 mm with weight 1.5-1.8
kg/rn mt of aluminium of Alm brand / grade T
T6, powder code as per selection of make akzonoble
/ jotun,with 70 microns and 10 years warranty with
hardware of Bearing load capacity 80 kg,window wise
roller pcs 2 WHEEL,window wise bearing pcs
pcs,Lock type TELESIA,EPDM Company
MAHARASTRA POLYMER,of black shade, with
single point locking handle system , using 5+5 mm
laminated toughened glass with 1.52 mm pvb film as
of brand 3m or equivalent ,etc including transport
fittings, lead etc,and completing th e work as per
instruction of architect incharge.
12 55.98 CDC WOODEN FLOORING 3535.00 SQ.MT.
Providing and fixing of approved 6 MM THICK CDC
wooden floor(WITH V-GROOVE) including all
accessories, skirting profiles , reducer profiles, corner
profiles ,vapour barrier/ hitlon ,material,
labour,installation etc. guranteed for 20 years and
class 23 heavy usage in domestic area.and complete
the work satisfactorily as per instruction of architect or
Engineer-in charge.
13 128.16 PERFORATED ACOUSTICAL PANELLING 5252.00 SQMT
Providing and fixing MDF based 600mm x 600mm x
15mm perforated acoustical paneling Fixing with
Sound Strut screw fixed horizontal/vertical to wall at
every 600mm c/c.as per drawing details , Metal cleat
can be fixed on top edges of Sound Strut Ceiling
Section 55 or base GI framing fixed directly by
stamping to the CS55 and Intermediate Channel-91
which is screw fixed directly to the wall where ever
required and using Rock wool between framing and
panel with technical specification of 40 Kg Density
and 50MM thick and above CS55 fixing aluminum
channel with clip and fixing Knauf / Arbuda Acoustic
Panel make module of size 600mmx600mmx15mm
thick up to 2400mm high as per the following
specification :- Medium Density Fiber acoustic boards
with Tongue & Groove Edge, 4mm slot perforation @
64mm centre, slates perforations, The acoustic
should be furnished with a Black absorbent felt
backing with an airflow resistance of 330-460 Ns/m³
(DIN 53887),wood practical core,NRC : should be
14 176.40 TRIANGLE MULTI CELL CEILING 4085.45 SQMT
Providing and fixing horizontal level Triangle Open
cell GI lay-in ceiling tiles with border panels forming
board edge of size 600x600x38mm (Nominal) having
cell size of 200x200mm made of 120 gsm galvanized
steel as per IS 277 (2003) suitable for architectural
finishes in 0.35mm thickness as per in IS:513 (1994)
in Global white color having same thickness diagonal
member. The tile shall be electrostatically polyester
powder coated using RoHS compliant powder having
coating thickness ranging from 60-80 microns. The
powder coating shall pass Salt Spray Test for
hours as per ASTM B117, QUV –A Test for
hours as per ASTM G-154 – (Cycle – 1) and Humidity
test for 1000 hours as per DIN 50017. The powder
coating shall have an adhesion of GT0 as per EN ISO
2409. The shade variation across batches shall be
delta E<1 using Excite/BYK Gardner instrument and
gloss level of 25±5% at 60˚ as per ASTM D523. Tile
shall have a Fire Performance class A1 as per EN-
13964.including all labour, l
15 257.99 800 X 3000 COMPOSITE SLAB FLOORING 5145.95 SQMT
'Providing and laying granite slab of 800 x
SPACE GREY 18mm thick in flooring Risers of steps
/ Dedo , landing & with 3M brand antiskid tape laid on
a bed laid on a bed of 12mm thick Adhesive chemical
of roff T-05 Category(Roff Vitrofix Ultra Adhesive is a
highly polymer modified,thin-set tile adhesive) and
finishing with flush pointing incl. rounding the outer
edge, moulding,polishing, resurfacing of existing
flooring etc and complete the work satisfactorily as
per instruction of architect or Engineer-in charge.
16 37.80 TRAP DOOR INCLUDING REQUIRED BOXING AND 6509.45 SQ.MT.
FRAMING FOR AC UNIT
Providing and fixing of TRAPDOOR for ac using
TWO SHUTTERS OF 35mm flush door( Made from
pine framing AND AS PER DETAIL) for shutter &
mm ply for framing and vertical support (AS PER
DRAWINGS)of brand door house or equivalent
etc,ghana wood beading patti etc. including all
hardware items like 4 nos alllenkey lock ,stopper,
hinges, groove (if shown) with all materials, labour,
lead and wastage etc. complete. And Finished with
different materials,and complete the work
satisfactorily as per instruction of architect or
Engineer-in charge.(BASIC AREA OF TRAP DOOR
IS 2.40X 2.00 MT (As per Dwg.) = 4.80 sq.m.
17 82.20 WOODEN CEILING 3126.69 SQ.MT.
Providing and fixing of wooden ceiling using 12 mm
ply of brand greenply ecotech mr,century sainik
mr,srg etc, , aluminium channel & pipe(50 x 25 mm)
for framing and suspension, screws etc. including all
vertical support and all vertical surfaces from
ceiling,necessary hardwares,75mm anchor fastners
and complete with all material, making of coves and
cutouts for ac grills ,labour & scaffolding with all lead,
lift and transport. and finished and complete the work
satisfactorily as per instruction of architect or
Engineer-in charge.
18 11.09 MIRROR FINISH(5mm thick brown/black Mirror) 3740.03 SQ.MT.
Providing and fitting of mirror/glass (as per drawing &
approved shade)of brand ais,modiguard,etc on ply
panelling / on tile cladding including all material,
labour and hardware, cutouts, edge polishes,waste of
materials and complete the work satisfactorily as per
instruction of architect or Engineer-in charge.
19 357.50 TERRACE WATER PROOFING 734.27 SQMT
Providing and laying integral cement based water
proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces
etc. consisting of following operations.
(a) Applying and grouting a slurry coat of neat
cement using 2.75 kg/sqm of cement admixed with
proprietary water proofing compound comforming to
IS:2645 over the R.C.C. slab including cleaning the
surface before tratment.
(b) Laying cement concrete using broken bricks/brick
bats 25 mm to 100 mm size with 50% of cement
mortar 1:5 (1 Cement : 5 Coarse sand) admixed with
proprietary water proofing compound conforming to
IS:2645,brick bats is finally covered by jointless
cement plaster 20mm th. in cu.m. 1:4 added with
special water proofing compound confirming to
IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is
carried along the vertical surface of the parapet &
other adjoining wall up to height of about 300 mm in a
shape of quartier roun
20 357.50 BROKEN CHINE MOSAIC FLOORING 779.70 SQMT
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of
glazed tiles to be laid over cement mortar 1:3 to plain
or slope and to be tempered to bring mortar creme
out upto surface using white cement including
rounding off junctions and extending them upto 15 cm
along the wall,clearing with water and oxalic acid etc.
21 10.00 PAINTING 60" X 60"/WALL ART 11110.00 NO
Providing and fixing of Printed painting/wall art as per
selection and complete the work satisfactorily as per
instruction of architect or Engineer-in charge.Basic
rate of painting is 8000/- per painting.
22 10.00 PLANTER WITH REAL PLANTS 3535.00 NO
Providing and fixing of planter/pots of frp or plastic
with real indoor plants as per selection and complete
the work satisfactorily as per instruction of architect or
Engineer-in charge.
23 613.59 OUTSIDE @ANTI EFFLORECENCE COAT 404.00 SQ.MT.
Providing and applying two coats water base anti
efflorecence coarting on stone crete texture, inc.
scaffolding, cleaning the wall & preparing the surface
even & smooth, filling the cracks incl. applying one
coat of white priming coat of reputed brand as
suggested by DEPUTY ENGINEER. etc. comp.as
directed. including all material,celeaning of old
stoncrete plaster as per directions, etc and complete
the work satisfactorily as per instruction of architect or
Engineer-in charge.
24 20.00 CORE CUTTING 656.50 NO
Providing and fixing of core cutting upto 50 to 150 mm
dia core in rcc members(beams) or walls for
concealing A/C piping or electric conduting ,carried
out using cutter machine.Fillinging of zari up to first
coat of plastering,finishing with colour/ putty work
,with all material, labour, lead,scaffolding and
wastage etc and complete the work satisfactorily as
per instruction of architect or Engineer-in charge.
25 9.00 DISMENTLING WINDOW 656.50 NO
Dismentling doors, windows, ventilators etc. (wood or
steel) shutters including chowkhats architraves, hold
fasts and other attachment etc. complete and
stacking them within all lead and lift.(i) Not exceeding
3 Sq.M. in area.
26 262.24 PLASTIC PAINT 353.50 SQ.MT.
Providing and applying plastic paint of approved
quality, company and shade upto finishing (min
coats) including all material, labour including
scaffolding etc. and complete the work satisfactorily
as per instruction of architect or Engineer-in charge.
27 38 SUPLYING, INSTALING, TESTING AND
COMMISSIONING OF Of your
premises of pipes and as per spec G.I. Pipe fittings
such as Bends, Tees, reducers, rubber insertions
asnd galvanised nuts and bolts includding Flow
Directions Marketing, One coat of Primer, one coat of
Signal Red color 100 MM (M.R.)
28 28 SUPLYING, INSTALING, TESTING AND
COMMISSIONING OF Of your
premises of pipes and as per spec G.I. Pipe fittings
such as Bends, Tees, reducers, rubber insertions
asnd galvanised nuts and bolts includding Flow
Directions Marketing, One coat of Primer, one coat of
Signal Red color 50 MM (M.R.)
29 45 SUPLYING, INSTALING, TESTING AND
COMMISSIONING OF Of your
premises of pipes and as per spec G.I. Pipe fittings
such as Bends, Tees, reducers, rubber insertions
asnd galvanised nuts and bolts includding Flow
Directions Marketing, One coat of Primer, one coat of
Signal Red color 25 MM (M.R.)
30 65 SUPLYING, INSTALING, TESTING AND
COMMISSIONING OF Of your
premises of pipes and as per spec G.I. Pipe fittings
such as Bends, Tees, reducers, rubber insertions
asnd galvanised nuts and bolts includding Flow
Directions Marketing, One coat of Primer, one coat of
Signal Red color 25 MM (M.R.)
31 2.00 (i) 4 wire 10 sq. mm (use earth wire of 4 sq.mm ) 5858.00 Nos.
32 4.00 providing and erecting Mains with ISI marked, 1.5KV 3232.00 Nos.
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required.(e) One wire 6.00 sq. mm
33 2.00 (g) One wire 16.00 sq. mm 1888.70 Nos.
34 2.00 Supplying and erecting Flexible PVC insulated multi 7676.00 Nos.
strand multi core 1.1 kv grade ISI marked copper
wires of following size to be erected as directed. (d)
1.50 Sq.mm 2 core round PVC sheathed
35 2.00 (e) 1.50 Sq.mm 3 core round PVC sheathed 2918.90 Nos.
36 2.00 Providing & erecting Switch board for Computer or 7878.00 Nos.
electric apparatus consisting of following modular
type accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame
covered with textured/metallic /white front
37 1.00 Supplying and erecting LED indoor fittings with LEDs 6565.00 Nos.
of wattage 0.2 Watt to 0.5 Watt assembled on single
street sink/ Flood
light 4747.00 Nos.
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder
39 1.00 Supplying and erecting LED indoor fittings with LEDs 7979.00 Nos.
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20 (iv) 22-24
watts, Surge-2 KV Cat-lll
40 1.00 Providing & erecting weather proof, dust & vermin 6767.00 Nos.
proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge
made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories
supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, suitable size of
inter connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end
terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall
be painted with epoxy powder c
41 1.00 Supplying and erecting triple pole & neutral 440V / 7322.50 Nos.
500V panel mounting Copper Busbars with four equal
Nos. of electrolyte bus having current density not
more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape
for phase sequence of following current carrying
capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in
42 32.00 providing and erecting Miniature circuit breaker single 4242.00 Nos.
pole 6A to 25A suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
43 1.00 Providing & erecting 240 V MCB double pole switch 52015.00 Nos.
for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 Amp. Cat.III
44 1.00 (B) 40 Amp. CatIII 22826.00 Nos.
45 1.00 Providing & erecting 415V MCB Four Pole Switch for 2222.00 Nos.
Lighting Load (B curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity (b)40 Amp. Cat.III
46 4.00 providing and erecting Approved make RCCBs 858.50 Nos.
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III[3-12-1.]
47 220.00 Providing and erecting Sheet Steel powder coated 80.80 Mtr.
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for(B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type
(PPI)(b) sheet steel double door(ii)6 way
48 15.00 Providing and erecting Annealed bare Copper wire 8 171.70 Mtr.
49 8.00 Supplying & erecting earth pit of minimum bore 212.10 Mtr.
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with
chamber and heavy duty cover.(approved make
OEM has to submit test certificate) & having back
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 meter testing as per
IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable
to retain moisture for long time Necessary test report
must be submitted. (a) For Electrical Installation up to
440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Ba
50 6.00 Pproviding and erecting Approved make Four pole 5908.50 Nos.
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal
& magnetic release suitable to work on A.C. supply
c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
51 6.00 PROVIDING CO2 TYPE FIRE EXTINGUISHER 1838.20 Nos.
4.5 KG ISI MARKED ALL REQUIRED FITTING
ACCESSORIES.(M.R.)
52 4.00 PROVIDING & FIXING OF MANUAL CALL POINT ISI 989.80 Nos.
MARKED ALL REQUIRED FITTING
ACCESSORIES.(M.R.)
53 4.00 SUPLYING, INSTALING, TESTING AND 1020.10 Nos.
COMMISSIONING OF FIRE HOOTER(M.R.)
54 1.00 Supply & installation of Conventational , Fire Alaem 12625.00 Nos.
Control Panel 4 zone Make Agni
55 32.00 Supply & installation of fire SMOKE 1666.50 Nos.
DETECTOR ISI MARKED ALL REQUIRED FITTING
56 1.00 PROVIDING & FIXING OF PRESURE METER 2525.00 Nos.
SWITCH ISI MARKED(M.R.)
57 1.00 PROVIDING & FIXING OF PRESURE METER 1616.00 Nos.
GAUGE ISI MARKED(M.R.)
58 450.00 Design, supply & installation of safety signage made 8.08 SQ.INCH
of zinc base glow in the dark rigid sheet with high
luminous with pasted on 3 mm thick on rigid PVC
foam sheet. Such as EXIT EMERGENCY EXIT. Do
59 2.00 Core Cutting up to 100mm 808.00 NOS.
60 1.00 Fire NOC Consulting charges & Certificate 30300.00 JOB
process fees… etc comp
61 1.00 Fire NOC Approved Structure drawing charges 20200.00 JOB
62 22.20 Excavation for foundation upto 1.5 m depth including 123.13 C.M.
sorting out and stacking of useful materials and
disposing off the excavated stuff with all lead and lift
Meter lead.(A) Loose or soft soil
63 7.40 Excavation for foundation for depth from 1.5 m to 3.0 136.47 C.M.
m including sorting out and stacking of useful
materials and disposing off the excavated stuff upto
with all lead and lift Meter lead.(A) Loose or soft soil
64 2.30 Providing and laying cement concrete 1:2:4 (1- 3741.69 C.M.
Cement : 2- Coarse sand : 4- graded stone
aggregates 20 mm nominal size) and curing complete
excluding cost of formwork in (A) Foundation and
65 3.00 Providing and laying controlled cement concrete 4215.74 C.M.
M.200 and curing complete including the cost of
formwork but excluding cost of reinforcement for
reinforced concrete work in (A) Foundations, footings,
Base of columns and Mass concrete (upto 10 ton)
66 0.30 Providing and laying controlled cement concrete 6382.19 C.M.
M.200 and curing complete including the cost of
formwork but excluding cost of reinforcement for
reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level. (upto
67 1.60 Providing and laying controlled cement concrete 7270.99 C.M.
M.200 and curing complete including the cost of
formwork but excluding cost of reinforcement for
reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level. (upto
68 8.90 Providing and laying controlled cement concrete 9919.21 C.M.
M.200 and curing complete excluding the cost of
formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two
69 1301.00 Providing IS mark TMT Bar FE 500/500D 77.29 K.G.
reinforcement for R.C.C. work including bending,
binding and placing in position complete upto floor two
level (upto 10 ton)
70 39.00 Providing 15mm thick cement plaster in single coat on 282.44 S.M.
Rough (Similar)side of single or half brick walls for
interiorplastering upto floor two level and finished
even and smooth in (ii) Cement mortar 1:4 (1-cement
71 47.20 20mm thick sand faced cement plaster on walls upto 347.42 S.M.
height 10 metres above ground level consisting of
12mm thick backing coat of C.M. 1:3 (1-cement : 3-
sand) and 8mm thick finishing coat of C.M. 1:1 (1-
cement : 1-sand) etc. complete.
72 13.10 Providing cement vata (10 cm x 10 cm size) quarter 24.28 R.M.
round in cement mortar 1 :1 including neat cement
finishing watering etc. complete.
73 38.70 Providing and laying integral cement based water 802.95 S.M.
proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces
etc. consisting of following operations.
(a) Applying and grouting a slurry coat of neat
cement using 2.75 kg/sqm of cement admixed with
proprietary water proofing compound comforming to
IS:2645 over the R.C.C. slab including cleaning the
surface before tratment.
(b) Laying cement concrete using broken bricks/brick
bats 25 mm to 100 mm size with 50% of cement
mortar 1:5 (1 Cement : 5 Coarse sand) admixed with
proprietary water proofing compound conforming to
IS:2645,brick bats is finally covered by jointless
cement plaster 20mm th. in C.M. 1:4 added with
special water proofing compound confirming to
IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is
carried along the vertical surface of the parapet &
other adjoining wall up to height of about 300 mm in a
shape of quarter round vata Incl. curing etc.
74 38.70 Providing and laying white glazed tiles 6mm thick in 932.02 S.M.
skrting risers of steps and dedo on 10mm thick
cement plaster 1:3 (1-cement : 3-coarse sand) and
jointed with white cement slurry
75 11.00 Providing and laying white glazed tiles 6mm thick in 900.29 S.M.
flooring treads of steps and landing laid on a bed of
12mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in white cement.
76 12.00 (A) Extra over items 58 to 67 for providing and mixing 49.26 Per Bag
water proofing materials in cement mortar in of 50kg
proportion recommended by the manufacturer. of
77 58.00 Point wiring for Tissino / Modular secondary light point 200.99 Pt.
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green)
both are of ISI marked 1.1 kV grade FRLS PVC
insulated multi strand copper wires, in below type of
pipe to be erected complete with earth continuity and
necessary connection with primary light with
accessories erected on Metal / PVC / wooden box
covered with 3 mm thick PC(Polycarbonate) / Acrylic
sheet for open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as
directed. Note:- Maximum up to 6 mtrs length, excess
will be considered as Mains for Secondary Point. (f)
with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
78 62.00 Point wiring for Light / Bell with 2-1.5 sq.mm & 582.77 Pt.
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 kV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type
of pipe erected with 6A Modular type switch / bell
push & accessories and earth continuity of following
type, erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected on
/ in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat. III
79 26.00 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 809.01 Pt.
1.5 sq.mm (Green) both are of .ISI marked 1.1 kV
Grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step
type electronic fan regulator mounted and
accessories with earth continuity of following type
erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected on
/ in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
80 11.00 Point wiring for on board Looped Plug with 6A 309.06 Pt.
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories Cat. III
81 40.00 Providing following type of Modular Type Accessories 151.50 Ea.
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
metallic/white front plate , modules erected with
necessary connections as per site situation directed
by Engineer In charge. (1)One No. SP 6 Amp. Cat.III
82 40.00 (2) One No 5 pin plug Cat.III 151.50 Ea.
83 3.00 (3) Two Pin/RJ-11 Telephone Socket [A] For One 160.59 Ea.
84 8.00 (8) Computer RJ-45 socket Cat.III 160.59 Ea.
85 19.00 (9) 16 Amp. SP one way switch Cat.III 180.79 Ea.
86 19.00 (10) 6/16Amp. Universal socket Cat.III 199.98 Ea.
87 580.00 Providing and erecting ISI mark Medium class RIGID 33.33 Mtr.
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed (b) 25 mm
88 918.00 Providing and erecting Mains with 1.1 kV grade FRLS 104.03 Mtr.
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (A)
With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm
89 486.00 providing and erecting Mains with 1.1 kV grade FRLS 140.39 Mtr.
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall
/ ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
91 24.00 Providing and erecting Mains with ISI marked, 1.5kV 70.70 Mtr.
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms
to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if
required. (e) One wire 6.00 sq. mm
92 69.00 (f) One wire 10.00 sq. mm 115.14 Mtr.
93 12.00 (h) One wire 25.00 sq. mm 295.93 Mtr.
94 360.00 Supplying and erecting Flexible PVC insulated multi 221.19 Mtr.
strand multi core 1.1 kV grade ISI marked copper
wires of following size to be erected as directed. (k)
4.00Sq.mm 4 core round PVC sheathed
95 60.00 Supplying & erecting approved make Telephone 20.20 Mtr.
Cable electrolytic copper conductor PE insulation
twisted in two pairs, & wrapped with FRLS PVC tape
& sheathed with FRLS PVC or HFFR outer Jacket
suitable for telephone wiring & confirming to C-DOT
erected in existing pipe. of following size of
conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a)
Unarmoured (2) Two Pairs
96 160.00 Supplying & erecting approved make LAN cable of 47.47 Mtr.
following size in existing pipe as per direction [C] CAT
97 8.00 Providing & erecting Switch board for Computer or 1133.22 Ea.
electric apparatus consisting of following modular
type accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame
covered with textured/metallic /white front
plate,modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories
98 94.00 Supplying and erecting LED indoor fittings with LEDs 758.51 Ea.
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/
CRCA/ aluminium pressure die cast powder coated
and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company
mark/ name 160V to 270V, Power Factor more than
0.95, THD < 15 %, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt, LED driver efficiency >
% (fitting required LM-79 & LM-80 Certificates)
(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between
the ranges shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20 (iv) 22-24
watts, Surge-2 kV Cat-lll
99 26.00 (I) Adjustable spot light with COB led having 2161.40 Ea.
aluminium reflector of following wattage (iv) 30 Watts
100 3.00 Providing and erecting Approved make Four pole 6790.23 Ea.
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal
& magnetic release suitable to work on A.C. supply
Hz. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
101 4.00 Providing and erecting Approved make Four pole 17843.67 Ea.
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A.with variable Thermal & magnetic
release suitable to work on A.C.supply 50 Hz. with all
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S.housing
ICS=100% of ICU only Cat III
102 2.00 Providing and erecting Approved make Earth fault 5482.28 Ea.
Relay suitable to mount with inter connection suitable
to following size of moulded case circuit breaker
having CT ratio & MCCB rating as following along
with shunt trip 220V AC. with all internal connections
& complete erected in existing M.S.housing.. (2)
A -200 A , CT Ratio 1/200
103 2.00 Supplying & erecting approved make Four Pole 415V 12241.20 Ea.
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
(D)200A Cat.III
104 2.50 Supplying and erecting triple pole & neutral 440V / 3202.71 Rmt
500V panel mounting Copper Busbars with four equal
Nos. of electrolyte bus having current density not
more than 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour insulating tape
for phase sequence of following current carrying
capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in
existing cubical panel with necessary connections.
(B) Suitable for 200 Amp. capacity
105 48.00 Providing and erecting Miniature circuit breaker single 123.22 Ea.
pole 6A to 25A suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996
with ISI Mark Cat.III
106 6.00 Providing & erecting 240 V MCB double pole switch 362.59 Ea.
for motor & inductive load (C Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in existing
box having following capacity (B) 40 Amp. Cat.III
107 14.00 Providing & erecting 415 V MCB Four Pole for Motor 736.29 Ea.
& Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity (b)40 Amp. Cat.III
108 10.00 (c)63 Amp. Cat.III 811.03 Ea.
109 4.00 Providing and erecting Sheet Steel powder coated 2339.16 Ea.
MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
suitable for (B) three phase incoming and single
phase horizontal type outgoing Per phase isolation
type (PPI) (b) sheet steel double door (i)4 way
110 12.00 providing and erecting Approved make RCCBs 2458.34 Ea.
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
111 14.00 Providing and erecting Annealed bare Copper wire 794.87 Kg.
112 7.00 Supplying & erecting earth pit of minimum bore 4591.46 Ea.
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make
OEM has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to ensure
the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound
should be capab
113 4.00 Providing & erecting weather proof, dust & vermin 10468.65 Smt.
proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge
made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories
supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, suitable size of
inter connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with locking
arrangement and rubber gasket,heavy duty end
terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall
be painted with epoxy powder
114 45.00 Providing , erecting , fabricating the M.S. structure as 77.77 Kg.
per requirement on site incorporating proper size of
M.S. angles,square,round, flats, bars, channels,
sections complete with cutting, welding, grinding &
finishing duly painted with one coat of red oxide with
erection on site as per direction of engineer in charge
with necessary grouting, cementing, plastering &
finishing complete.
115 160.00 Providing and erecting FRLS-XLPE (IS:7098) (I) -88 589.84 Mtr.
ISI armoured cable multistrand Aluminium conductor
for 1.1 kV. to be laid on wall with necessary clamps
or in existing trench / pipe of following size of cables
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
116 50.00 Making trench in soft soil of suitable width of 90 cm 55.55 Mtr.
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
117 50.00 Providing & laying approved make Double walled 62.62 Mtr.
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting
accessories of same material at required depth in
existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
118 2.00 Providing and, fixing heavy duty flange type brass 131.30 Ea.
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
cables. (D) 3 & 1/2 core 95 Sq. mm
119 8.00 Solder less crimping type Aluminium lugs conforming 40.40 Ea.
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/ cadmium plated nut
bolts in an approved manner. (F) 95 Sq.mm.
120 26.00 Providing & erecting Approved make Power Saving 1948.29 Ea.
45 - 50 Watt Ceiling Fan with double ball bearing ISI
mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium
blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in
121 50.00 Supplying and erecting 19 / 20 mm. nominal bore 108.07 Mtr.
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation without
leakage and earthing.
122 26.00 Supplying & erecting fan hook box of 10 mm M.S. 108.07 Ea.
round bar bounded to the RCC bars up to 50mm
length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
123 24.00 Supplying and erecting approved make oscillating 2352.29 Ea.
type medium duty bracket fan with Aluminium Blades
A.C. 230V. 50 Hz wall mounted with height
adjustment and rotary tilting device complete with
guard, mounting accessories kit, pull cord for speed
and oscillation flexible Core plug top complete erected
with lead wires as directed. (a) 400mm
124 2.00 Providing and erecting Inverter based approved make 79620.32 Ea.
split air-conditioning unit consisting of condensing unit
with variable speed fan motor, inverter type
hermetically sealed rotary compressor with
accessories etc. duly connected separately erected
evaporating unit and blower motor with its
accessories by means of extra supplied proper
insulated copper tubing,drain PVC pipes suitable for (
cost includes Eco Friendly green gas charging and
15A plug top & Remote Control & MS Stand) with
necessary core cutting. (2)For ISEER Range
(KWH/KWH)(4.0 to 4.49) (C) for 1.7 to 2 ton capacity-
125 12.00 Providing and erecting Inverter based approved make 145049.13 Ea.
Cassette type split air-conditioning unit consisting of
condensing unit with fan motor, hermetically sealed
scroll/rotary compressor with accessories etc. duly
connected separately erected evaporating unit and
blower motor with its accessories by Eco friendly
Green gas charging & Internal copper wiring &
Remote control ( 3 star and above of current year)
with necessary core cutting. (C) for 3 ton capacity-
126 210.00 Supplying and erecting insulated pair of soft copper 1158.47 Rmt.
tubing open or concealed including power and control
cable,necessary PVC drain pipes for Split/Cassette
AC machine up to 4 TR capacity
127 1.00 Providing & erecting water cooler having storage 61482.74 Ea.
capacity 150 Ltr. & cooling capacity 150 Ltr.per hour
@ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water
cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats, relay
etc.complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless
Steel and ISI Certified.
128 1.00 Supplying & erecting reverse osmosis (RO) water 77891.20 Ea.
purification system with M.S. powder coated pedestal
frame, prefilter housing carbon filter suitable buster
DC pump, auto low & high pressure switches with
following size of LPH capacity & erected as directed
[D] 100 LPH with 1 phase / 3 phase Raw water pump
of 500LPH @ 2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi),
Dual media filter 10"x54" - (1 No), Micron cartridge
filter 20" x 2.5" ( 1No), High pressure pump 500LPH
@ 10kg/cm2 - (1No - Shimge /CRI /Lubi), RO
Membrane housing with RO membrane of 40*40 -
(1No), RO pressure tube 4" x 1E - ( 1No), 0 -
1200LPH Rotameter -(2 Nos), with Recovery Rate
129 2.00 Supplying and erecting approved make panel 1275.63 Ea.
mounting type Digital Voltmeter having 3 digits LED
display, 0 to 750 AC Volts range erected on existing
panel board with all connection, wiring etc .with
manufacturers calibration certificate.
130 2.00 Supplying and erecting approved make panel 1558.43 Ea.
mounting type Digital Ammeter having 3 digits LED
display, external CT operated, calibrated for 0 to
Amps suitable to operate on 500 Volt AC, erected on
existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
131 4.00 Supplying and erecting Ammeter / Voltmeter selector 317.14 Ea.
switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections.
132 6.00 Providing & erecting L.T. Current Transformer with 274.72 Ea.
bar primary 50/5 to 1000/5 ratio 15 VA burden erected
in existing CRCA box duly secured with insulating
materials connected to the meter
133 6.00 Supplying and erecting approved make suitable panel 43.43 Ea.
indicator LED type lamp, lens cover, complete erected
with necessary connections.
134 540.00 Providing and erecting ISI mark Medium class RIGID 24.24 Mtr.
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed (a)20 mm
135 540.00 Supplying and erecting Flexible PVC insulated multi 71.71 Mtr.
strand multi core 1.1 kV grade ISI marked copper
wires of following size to be erected as directed. (g)
2.50 Sq.mm 2 core round PVC sheathed
136 1.00 Supplying & erecting Amplifier having following 13558.24 Ea.
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
LED Meter :5 LED Arrays
The amplifier suitable to operate 240V A.C.& 24volt
D.C. (Battery) with automatic changeover from AC to
Battery operation, duly protected by wrong Battery
Polarity connections. [[Approved by Competent
Authority i.e. not Below the rank of Executive
137 24.00 Supplying and erecting ceiling speaker with rated 3083.53 Ea.
power of 30 watt/power tapping 30/15/7.5 watt
available,opening angle 180 degree H * 77 degree V
,sound pressure level 88 dB ,frequency response of
70Hz to 20KHz [[Approved by Competent Authority
i.e. not Below the rank of Executive Engineer ]
138 3.00 Supplying and erecting wall mount speaker with rated 3083.53 Ea.
power of 30 watt/power tapping 30/15/7.5 watt
available,opening angle 180 degree H * 77 degree V
,sound pressure level 88 dB ,frequency response of
70Hz to 20KHz [[Approved by Competent Authority
i.e. not Below the rank of Executive Engineer ]
139 2.00 Providing and erecting cordless microphone with UHF 6163.02 Ea.
Diversity handheld wireless microphone/caller
wireless complete with receiver and transmitter
unit,Cardiod ,polar pattern,dynamic microphone,LCD
display for battery and frequency status and
information ,32 preset channels,with compatible
groups of 8 channels,14 hrs.battery life,frequency
response 80Hz to 18KHz.,RF sensitivity <1.0
Uv,image rejection > 55 dB,dynamic range >95 dB
and receiver having 32 channels,S/N ratio>100
dBA,Dynamic range>95 dB,distortion<1% [[Approved
by Competent Authority i.e. not Below the rank of
Executive Engineer ]
140 6.00 Supplying & erecting carbon dioxide (CO2) fire 8671.86 Ea.
extinguisher user of following capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete. [B] For 5.5 / 6.5 KG
141 1.00 Supply, Installation, Testing and Commissioning 1286492.55 Ea.
(SITC) of Silent Type Diesel Generating (DG) Set(s)
of prime power rating (kVA) as specified, complete as
a packaged system, conforming to CPCB IV+ (or
better) emission norms, and complying with all
applicable statutory requirements, codes and
standards including (but not limited to) IS 4722:1968,
IS 13364 (Part 2) and BS 5514 (latest
editions/amendments). The DG set shall be suitable
for 415 V ±10%, 50 Hz ±5%, 3-phase, 4-wire
operation at 0.8 lagging power factor, 1500 RPM, for
tropical conditions, and shall be capable of delivering
10% overload for one (1) hour after twelve (12) hours
of continuous operation (ISO 8528), unless otherwise
stated by the OEM. The scope shall include complete
accessories, interconnections, foundations/anti-
vibration arrangements, exhaust system, acoustic
enclosure, earthing (as required), consumables for
first commissioning, and all works necessary to
render the installation fully functional and compliant,
as directed by the Engine
The DG set shall be provided with a durable QR
code/label fixed on the enclosure/control panel,
linking to a document repository containing (as a
minimum) approved GA drawings, wiring diagrams,
foundation and installation details, OEM catalogues,
operating & maintenance manuals, factory test
reports, type test certificates (where applicable),
warranty certificate, geo-tag of manufacturing
location, and rating plate data as per relevant
IS/BS/ISO requirements. The OEM/Contractor shall
provide a Remote Monitoring System (RMS) with
minimum one (1) year connectivity (SIM/data
plan/server access as applicable), including
dashboard access, user ID/password, and data
download facility. RMS shall, at minimum, capture
and report: DG status (Auto/Manual/Off), start/stop
events, kW/kVA/kVAR, V/I/Hz, PF, run hours, fuel
level, battery voltage, alarms/trips with time stamp,
and GPS/location (where supported). All
licences/subscriptions required for the stated period
shall be included in the quoted price.
(A) Diesel Engine:
Turbocharged, 4-stroke, water-cooled, multi-cylinder
diesel engine, suitably rated for the specified DG set
prime rating at site conditions, complete with
dynamically balanced flywheel, heavy-duty engine
mounting, and electric starting arrangement. The
engine governing shall be electronic
(isochronous/droop as per OEM standard) and shall
comply with ISO 8528/BS 5514 requirements for
steady-state speed regulation. Engine shall be
complete with dry type air cleaner with restriction
indicator, lube oil cooler (if required), radiator/cooling
package (as applicable), and all sensors/switches
required for protections and annunciation. The engine
shall be capable of 10% overload for one (1) hour
after twelve (12) hours continuous operation and shall
be suitable for continuous duty under tropical ambient
conditions. The offered engine model shall be CPCB
IV+ compliant and shall be supplied with complete
emission control/after-treatment system (including
DEF/urea dosing where applicable) along with
(B) Engine-Mounted Instrumentation/Control Panel:
Engine-mounted instrument/control panel shall be
microprocessor based, with LCD/LED display, event
log and alarm/trip annunciation, complete with all
wiring, harnesses and terminations.
Indications/protections shall include (minimum) the
following and any additional protections
recommended by the OEM: (i) Start/Stop key switch
and/or push buttons with emergency stop; (ii) Output
breaker: suitably rated 4-pole ACB/MCCB/MCB as
applicable, with minimum 25 kA rupturing capacity (or
as per fault level at site, whichever is higher), with
shunt trip where required; (iii) Jacket water/coolant
temperature – indication and high temperature
alarm/trip; (iv) Lube oil pressure – indication and low
pressure alarm/trip; (v) Lube oil temperature (where
provided) – indication/alarm; (vi) Battery charging
indication, battery voltage indication and charging
failure alarm; (vii) Engine speed (RPM) indication and
overspeed trip; (viii) Engine running hours meter (non-
(C) Alternator:
Synchronous, brushless alternator of appropriate kVA
rating, 415 V, 3-phase, 50 Hz, 1500 RPM, 0.8 lagging
PF, continuous duty, dynamically balanced rotor, self-
cooled, self-excited and AVR regulated. Enclosure
shall be SPDP, minimum IP23. Insulation shall be
Class H with suitable tropicalization; temperature rise
shall be within limits of the applicable standard. The
alternator shall comply with IS 13364 (Part 2), IS
and/or BS 2613 (latest), as applicable. Voltage
regulation with AVR shall be within ±1.0% (steady
state) or OEM standard whichever is better. The
alternator shall be capable of 10% overload for one
(1) hour after twelve (12) hours of continuous
operation. Harmonic distortion shall be suitable for
non-linear loads; alternator shall be equipped with
appropriate AVR features (e.g., soft start, UFRO) and
shall be suitable for motor starting duties typical to the
installation. Terminals shall be brought out to a
terminal box with adequate space for termination and
shall include ea
(D) Base Frame & Foundation: Engine and alternator
shall be mounted on a suitably designed, fabricated
MS channel base frame with stiffeners, lifting
arrangement and coupling guard, duly painted/treated
for corrosion protection. The set shall be installed on
an adequately designed cement concrete
foundation/pedestal with anchor bolts, pockets,
grouting and anti-vibration mounts (AVMs) / spring
isolators as per OEM recommendations and site
conditions. Vibration levels shall be within OEM
permissible limits. The contractor shall be responsible
for alignment, levelling, tightening torque and re-
check after load trial, complete in all respects.
(E) Fuel Tank: In-built/base fuel tank fabricated from
minimum 3 mm thick MS sheet, duly leak-tested,
complete with filling arrangement, vent, drain,
cleaning opening, level indication and isolation
valve(s). The capacity shall be adequate for minimum
eight (8) hours continuous operation at full load. Fuel
piping between tank and engine shall be MS ‘C’ class
(G) Starting System:
12 V / 24 V DC electric starting system (as per OEM
design) comprising starter motor(s), battery
charger/alternator charging arrangement, relays,
cabling and terminals, complete with maintenance-
free batteries of suitable Ah capacity to ensure
minimum three (3) consecutive cranking attempts.
System shall include battery isolator and indication of
charging healthy/failure. All battery interconnections
shall be with crimped lugs, insulated sleeves and
proper supports, complete in all respects.
(H) Acoustic and Weatherproof Enclosure: Acoustic
enclosure shall be factory-fabricated, weatherproof
and corrosion protected, suitable for outdoor
installation, with minimum IP65 protection (or better)
for the enclosure body. Enclosure design shall provide
adequate fresh air intake and hot air discharge for
engine radiator and alternator cooling such that the
internal temperature rise remains within OEM limits at
full load. Provision shall be made for safe
access/maintenance including lockable doors,
The enclosure shall comply with CPCB IV+ (or better)
requirements and other applicable local
rules/regulations. All louvers, acoustic infill/insulation,
fasteners and sealing arrangements shall be of fire-
retardant/industrial grade as per OEM standard. Any
deviation from the specified noise/IP requirements
shall be treated as non-compliance unless explicitly
approved by the EIC in writing.Note: The DG set
specifications shall comply with the latest CPCB
guidelines/notifications and all applicable local
rules/regulations prevailing as on the last date of
tender submission applicable local rules/regulations
prevailing as on the last date of tender submission
(M) Continuous rating of 125 KVA ,BHP not less than
142 1.00 AMF Panel: 121201.01 Ea.
Free standing floor mounted IP 42 automatic
mains failure control panel including auto by-pass,
suitable for KVA as below for silent type DG set
complete with relays, timers, set of CTs for metering
& protection and energy analyser to indicate
currents, phase and line voltages, frequency,
power factor, KWH, Kilo Volt Ampere Reative
Hour (KVARH), KVA (Phase & Total), KW (MFM) &
provision for overload, short circuit, restricted earth
fault, under frequency, all complete and inter
locking and communication/ Ethernet
/RS485/SNMP port open protocol for BMS
integration including suitable software, the panel
shall be of DG Set. as per approved by
Engineering in charge and including the following:
1. Suitable numbers and appropriate capacity
ACB/ MCCB with electronic release for O/C & E/F and
shunt trip. (Icu=100%Ics) (Not below 25KA Breaking
Capacity at 415Volts), (Total Three Breakers)
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage
phase reversal (2 nos Over voltage relay, 2 Nos.
reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy
for protection and 15 VA class-I for metering
5. Energy analyser unit to indicate current, Voltage( L-
N & L_L), kW, kVA (Phase & Total), Frequency,
6. LED Indicating lamps for load on mains and load
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/
rectifier, D.C. voltmeter and ammeter, selector
switch for trickle, off and boost and current
9. Control/Signal/Multi core/Communication Cables
between DG Set and AMF Panel upto 20 Mtr
10. Main supply failure monitor
11. Supply failure timer
14. Impulse counter with locking and reset facility.
15. ON/OFF/Control circuit switch with indicator16.
Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of
AC sensing, Over Current, Unbalancing load with
suitable number of relays and accessories
17. Maintenance notification based on Engine
Run Hour & due date.
18. Load Management through PLC to achieve
auto opening and closing of incomer breakers, bus
coupler switching of essential panel , interlocking
providing signal to AMF Panel for load status and
AMF shall give command to DG Set to auto start
/ auto stop depending upon load status and
requirement etc. and necessary hardware and
software required to perform the operation shall
be provided by the cont
143 15.00 Supply, Installation, Testing & Commissioning of 42455.35 PER KW
following size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall
Profile, Front Cover : High Transmission Low-Iron
Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed
with Bypass diodes, 100% Electroluminescence test
to ensure error free Modules, Thep. temp. co-efficient
of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill
factor 75% to be used. Unit Production:- More than
4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year
Product warranty. Modules must be complied to the
DCR(Domestic content requirements). The Ration of
AC to DC is 5:6 for the Installation capacity which are
given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000
V , Max efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p Power
Factor: ~1, O/P THDi: <3%, Operating Tempreture
Range: -25~60°C, Integrated protection of Inverter
are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault
protection, Residual Current Monitoring Unit, Output
Over Current Protection, Output Short Circuit
Protection, Output Over Voltage Protection, PV array
string fault Protection. Protection Degree: IP65, User
Interface LCD & APP, Datalogger & Communication:
Integrated, Input Reverse Polarity Protection
Integrated, Insulation Resistor Detection Integrated,
Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short
Circuit Protection Integrated, Output Over Voltage
Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication:
GPRS / Wi-Fi, Module Mounting Structure: The
mounting (Rectangular pipe / square pipe / circular
pipe) with requisite cross bars, nuts and bolts, etc.
shall be Hot deep galvanized with minimum 80micron
coating. The Rectangular / square /circular hollow
pipe section used for the structure should have a
minimum thickness of 2.0 mm. other than above, the
material thickness should be minimum 2.5 mm. A
certificate of a structural engineer certifying the
strength and stability of the mounting structure to
withstand the weight and wind speed of 150 km/hour
shall be submitted by the vendors. Hot Dipped
Galvanized steel coils. suitable arrangement for base
solar panel mounting, the structure should be suitable
for carry the load of solar panel,wiring, sprinkler
system etc. with necessary foundation work/wall
mount, j bolt, anchor fastner etc. the nut bolt used for
installtion of stucture should be (SS 304) quality.The
ground clearance of the bottom most edge of solar
panel shall not be less than 300 mm to 1200 mm or
as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should
b. Rafter - The minimum section (thickness) should
c. Purlin - The minimum section (thickness) should be
40MM * 40MM Balane of System with necessary
Swichgears (Suitabel size and protection of ACDB &
DCDB), inter connecting wiring, earthing system as
per the CEIG drawing approval,
lightining arrester system as per the CEIG drawing
approval, all liasoning work with various gov.
dipartment like state nodal agency,DISCOM & CEIG
is included in agency scope (Excluding All charges
namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing
Charges and system stability/strenthning charges.)
(Excluding All charges namely GEDA Application
fees, Solar connectivity Charges, Meter connectivity
Charges, Meter testing Charges and system
stability/strenthning charges.) (C ) Grid Tied Solar
Power System: 11 - 25 kW (3 - phase)
144 15.00 Providing & erecting Automatic solar panel cleaning 1841.23 PER KW
system for solar power projects which includes
necessary plumbing work (UPVC pipes and
accessories) from source of water to project site (up
to 30 meters),Suitable size of sub mercible/ open well
motor, necessary wiring for motor and sprinkler
system with safety, timer circuit for automatically
on/off the sprinkler system, necessary size oand
number of nozzles/JET (minimum 1 Nozzle/Jet per
module). (C ) 11KW-20KW Cleaning System
Rs. 1 crore fifty four lakhs four hundred thirty seven and ninty eight Paise Only.
I/We am/are willing to carry out the work at ………………………………………………..% above/below (percent should
be written in figures and words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
*Estimated amount *Estimated amount
Put to tende RS. Rs… 14650922.64 Put to tende RS. Rs…
Deduct ……. % below Rs……………………..…. Add ……. % Above Rs…………..….
Net Rs. …………………….… Total Rs. ………….…
*( please strike out whichever is not applicable)
Note :- 1 All works shall be carried out as public works department Handbook and other
specification of Division or as directed.
Note :- 2 All the columns in schedule should be filled in ink or ballpen and the total of the
entries in last column should be struck by the contractor under his signature.
Note :- 3 Rate quated include clearance of site (Prior commencement of work and at its close)
in all respects and hold good for work under all conditions,site moisture, weather etc.
Note :- 4 To be continued on additional sheet,if found necessary.
Deputy Executive Engineer Executive Engineer
Panchayat (R&B) Sub Division Panchayat (R&B) Division
Signature of the contractor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
3.Cement Standards -11-05-17 GR 2 Side.pdf
4.Tender Negotiation.pdf
5.Laboratory GR.pdf
6.GST GR.pdf
7.Steel Lap.pdf
11. Other GR.pdf
8.Clause 47 48.pdf
14 Building Booklet civil.pdf
Cement consumption gr.pdf
GST GR 1.pdf
Inspection 1.pdf
Laboratory GR 1.pdf
Steel Lap 1.pdf
5.GR.pdf
4.0 tender booklet.pdf
GR.pdf
Environment GR_11zon (1).pdf
Performance Bond and Bitumen date.pdf
6SBD GR.pdf
BOQ.pdf
GENERAL TECHNICAL SPECIFICATION .pdf
MORA COMUNNITY HALL ALL DRAWING SET.pdf
01_SBD_MORA HALL (1).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .