Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹42.6 L+₹4.6 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹43.4 L+₹5.4 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
24 Oct 2022, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Special repair to bldgs No T-42 of Inf Bn TA, P-14 Living Accn DET RVP in DOU, Special repair to retention wall at 150 GH, P-01 and P-04 at ASCON and special repair external wiring at Offrs Mess of Arty Bde at Rajouri under GE 862
2022_MES_554984_1
GER-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹86,000
Yes
7 Nov 2022
29 Sept 2022
26 Oct 2022
29 Sept 2022
24 Oct 2022
12 Oct 2022
Amount
Sch 'A' Part-I (B/R works) Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel 0.50mm thick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
M&L for rolled mild steel joist, channle, angle, or tee sections, fixed independently with or without connecting plates, cut to ordinary lengths i.e. within 20 mm of the length given complete all as specified and directed.
S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 290 grade E-1658 complete after dismantling of old unserviceble structural steel work all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
M&L for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for Machine cut kota stone slab(mirror polished) flooring 18-20mm thick in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) of any size complete all as specified and directed.
M&L for Machine cut kota stone slab(mirror polished) steps of riser 18-20mm thick in steps, risers, skirting and dado etc and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) of any sizecomplete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar (1:3) on fair faces of concrete surface of ceiling or concrete/brick surface complete all as specifed and directed.
M&L for 50mm thick PCC type C-2, (1:3:6) (using 40mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on Brick/stone masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on Brick/stone masonry (external surface) finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete etc complete all as specified and directed.
S&F of steel windows factory made with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as per IS-1038 complete all as specified and directed.
S&F of steel windows factory made with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as per IS-1038 complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 Sqm and n.exc 4 Sqm each (without taking off shutters from the frames) and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for 3 mm thick figured glass, pin headed type and glazing with oil putty in squares n . exc 0.50 sqm in each pane complete all as specified and directed.
S& F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F for 150mm long aluminium anodized barrel tower bolts extruded section all as specified and directed.
S&F for 125 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC (1:3:6) type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
S&F for viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) and inlcuding set of CP jet with PVC pipe of superior quality complete as in repair all as specified and directed.
S&F for 75mm dia cast iron floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe complete all as specifed and directed.
S&F for PVC low level flushing cistern 10 ltrs capacity white with inlet ball valve, float valve and handle including providing & fixing MS angle iron brackets, PVC flush pipe complete as in repair all as specified and as directed.
S&F for PVC connection 15 mm dia with PTMT nuts of length 450mm at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
S&F for 110mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor after taking down old unserviceable pipe complete all as specified and directed.
M&L for 110mm dia PVC SWR bends complete all as specifed and directed.
S&F for 75mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor after taking down old unserviceable pipecomplete all as specified and directed.
M&L for 75mm dia PVC SWR bends complete all as specifed and directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 15mm dia with all fittings etc complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 20mm dia with all fittings etc complete all as specified and directed.
Re-fixing of 15 mm bore galvanised iron GI tubing medium grade with all new fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable 15mm dia GI pipe with all fittings etc complete all as specified and directed.
Re-fixing of 20 mm bore galvanised iron GI tubing medium grade with all new fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable 15mm dia GI pipe with all fittings etc complete all as specified and directed.
M&L for 15mm dia bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe complete as in repair as in repair all as specified and directed.
M&L for 20mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L for preparation of old painted steel surfaces of roof sheet of any description exc 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden and wood based surfaces of any description exc 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F for Rotational moulded polythylene water storage tank (ISI marked multilayer) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 15mm bore ball brass valve with union (two nos each) screwed for iron pipe and fixed complete all as specifed and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x350x7mm/ 350x250x7mm (premium quality) on vertical surface such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares n . exc 0.50 sqm in each pane complete after hacking out old broken glass all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
M&L for providing and laying water proofing treatment to sunken portion of WCs bathroom etc by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound of make as approved:- (a) First layer of slurry of cement @ 0.488Kg/Sqm mixed with acrylic based polymder modified cementitious composite compound @ 0.253 Kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242Kg/Sqm mixed with acrylic based polymer modified cementitous composite compound @ 0.253 Kg?Sqm. This layer will be allowed to air cure for 4 hours. (c) Sealing of joint of Trap/WC/Soil pipes with sealing compound of MC bouchemie roofex/Forre/Choksv/Dr Beck & Covt/FOSROC.
S&F for 15mm stop valves (angle valve), cast copper alloy screwed down high byut fancy type, chromium plate pressure with long shank and cup and fixed complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of wall care putty after complete removal of existing treatment complete all as specified and directed.
M&L for PCC (1:3:6), type C-2 using 40mm graded stone aggregates as in surface channels and drain work complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed. (Note:- Inner girth only measured)
M&L for chequered cement concrete tiles of size 30 cmx 30cmx25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for stone walling of random rubble masonry (except stones, using old unserviceable stone after cleaning), uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 20 mm for lime or sand stone and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for hand packing of any thickness at back of walls over aches etc and raising (or lowering) to required level complete all as specified and directed
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for brick work with sub class 'B' bricks,(except bricks, using old unserviceable brick after cleaning), old size, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in beams and cantilevers, lintels, over 1.5 span the like complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Use & waste of formwork to sides and soffits of floor of roof beam, shelfs, plinth beam, lintal beam etc and similar works in rough finished flat surface of concrete complete all as specified and directed.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar (1:4) complete all as specified and directed.
M&L for 40mm thick (measured solid), precast cement concrete louvers and jallies with 1:2:4, type B-0 including all mouldings but excluding frame set in cement motar (1:4) complete all as specified and directed
Excavation in post holes (or similar holes) eacg n.exc 0.50 cum, getting out returing, filling in and remming earth or broken rubble mixed with earth around in layers not exc 25cm thick, watering and removing surplus soil to a distance n. exc 50m and making good surface in any type of soil complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed.
M&L for point wiring for one light point/fan/bell/buzzer point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing & caping of 25mm width (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 83 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switchcomplete all as specified and directed.
Description all as per Serial item No 83 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch complete all as specified and directed.
Description all as per Serial item No 83 above but for one 6 pin 16/6 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
M&L for Socket outlet 2 in 1 , 5 pin 5 amp 230 volts flush type complete all as specified and directed.
M&L for socket outlet 2 in 1, 5 &15 Amp 230 volts flush type complete all as specified and directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
M&L for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9watt complete all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Make :- Havells cat No LHEXARP7SN1W020 or equivalent in Crompton)
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion after dismantling of old unserviceable earthing complete all as specified.
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 08 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole & neutral 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Taking down ceiling fan, cable end, including dismantling blades and removing fan and blades to store complete all as specified and directed
M&L for Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. (Make :- Havells Cat part No HEXAFT10WLED857SSYMBOPC/Crompton Greaves Cat No. LBHP-10-CDL or equivalant of Philips)
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Description all as per Serial item No 83 above but for one light point controlled by two way switches with cableof size 1.5 Sq mm complete all as specified and directed.
M&L for switch socket combination, 2 in 1 , 3 pin 5 amp 230 volts flush type complete all as specified and directed.
M&L for Switch piano, flush type single pole, two way 5 Amp, 240 volts complete all as specified and directed.
M&L for LED Tube light fitting, 1x 10 watts, complete with 2 feet Decorative ultra slim linear LED lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core complete as in repair all as required at site or directed. (Make :- Havells, Cat part No LUMILINEBS9WLED865SPCWH or equivalent of Crompton/Philips).
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for foundation, laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
Excavation in trenches more than exceeding 1.5 m wide and more than exceeding 1.5 m depth on plan for foundation, laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for sub main wiring complete with 2 run of 2.5 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 2.5 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 2.5 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
S&F for street light bracket made out of 32mm bore GI tubing light grade made to shape 3 mtr long bent to shape 90 degree and fixing with two numbers of MS clamp of 50mm x 6mm thick flat iron including , nuts, bolts, washer duly painted with synthetic aluminium paint two coats over a coat of red oxide primer complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for PVC junction box of size 300mm x 250mm x 150mm weather proof fixing arrangement etc using suitable clamps nuts, bolts etc for accommodating and four strip aluminium bus bar of (capacity 63 Amp, inlcuding and mounted on epoxy insulator 01 setand MCB SP 10 Amps -01 No comple all as specified and directed.
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement after dismantling of old unserviceable panel with all fitting and fixtures etc. The minimum depth height width of panel is1300mm x 1300x 600mm respectively, minimum claerance from ground level is 600 mm complete all as specified and comprising :- (a) MCCB, 125 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 100 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No ((Adjustable type, as thermal magnetic release) (c) MCCB, 63 Amps, FP, 36 KA, 415 volts, 50 Hz - 02 Nos ((Adjustable type, as thermal magnetic release) (d) MCB, 32 Amps, SPN, 10KA, 415 volts, 50 Hz, "C" Series - 7 Nos (d) Digital voltmeter (0-500V) with CTs and VSS-01 set (e) Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement after dismantling of old unserviceable panel with all fitting and fixtures etc. The minimum depth height width of panel is1400mm x 1400x 600mm respectively, minimum claerance from ground level is 600 mm complete all as specified and comprising :- (a) MCCB, 100 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 63 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No ((Adjustable type, as thermal magnetic release) (c) MCCB, 40 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No ((Adjustable type, as thermal magnetic release) (d) MCB, 32 Amps, SPN, 10KA, 415 volts, 50 Hz, "C" Series - 10 Nos (d) Digital voltmeter (0-500V) with CTs and VSS-01 set (e) Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated (seven tank process) and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement after dismantling of old unserviceable panel with all fitting and fixtures etc. The minimum depth height width of panel is1350mm x 1350mmx 600mm respectively, minimum claerance from ground level is 600 mm complete all as specified and comprising :- (a) MCCB, 63 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 40 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No ((Adjustable type, as thermal magnetic release) (c) MCCB, 25 Amps, FP, 36 KA, 415 volts, 50 Hz - 02 Nos ((Adjustable type, as thermal magnetic release) (d) MCB, 32 Amps, SPN, 10KA, 415 volts, 50 Hz, "C" Series - 06 Nos (d) Digital voltmeter (0-500V) with CTs and VSS-01 set (e) Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
S&F for environmental friendly, ultra modern, energy saving, LED flood lights of 40 watt with best in class design & robust heat sink alongwith class leading of IP-66 rating & surge protections for long lasting performance and connecting electrically with sheathed flexible copper cnductor cable of size 1.5 Sqmm 3 core cable with necessary fixing arrangements at any height and including removing old unserviceable all as required at site or complete all as specified and directed. (Make: Havells cat No JETAALBAFLOODLIGHT40W/ Crompton cat No LFLN-40-CDL/60m or equivalent model of Philips)
S&F for decorative LED Bollard light with diffuers outdoor type LED Bollard light 8W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable complete as in repair all as specified and directed. (Make :- Havells cat No CONEBLS8WLED830PSYMTOPC) or equivalent model of Philips)
M&L for high light intensity empowered color changing and manochromatic LED under water rating IP68, 12 watt fountain light with polarized light design and intelligent lograrithmic control technology for fountain all as specified and directed. (Make: Havells/philips).
S&F for LED street light fitting 30 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed (Make:- Crompton, Model No FREEDOM NEO LSTS-30-CDL-M or Havells, Cat No ENDURA PEARL NEO SL30WLED757PASYTOPC)
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 04 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
S&F for factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 8 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 63 Amps, FP, rating upto 36 KA and MCB SP/TP as outoing and complete with including 200 Amps rated copper busbar, neutral bar, earth bar, conneting cable links with and including top bottom removeable gland plate complewte with IP 43 protection complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCCB triple pole and neutral 415 volts any rating 100 amps, with rupturing capacity 36 KA,including providing thimble for out going cables complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion after dismantling of old unserviceable earthing complete all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
M&L for PCC 1:2:4, type B2 (using 40 mm graded stone aggregates) as in sub base, foundation filling and mass concrete to post of fence etc complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S RAHUL GUPTA
M/s Anil Engineers & Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .