| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹30.0 L+₹62,910 (2.14%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹34.9 L+₹5.5 L (18.8%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹35.6 L+₹6.2 L (21.2%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹36.9 L+₹7.5 L (25.6%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
29 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AF AMBALA
HQ CWE AF Ambala
CA NO CWE/AF AMB/AMB-32/2020-21 REPAIR / MAINTENANCE OF HT OVERHEAD LINES, HT EQUIPMENT,HT CABLES AND CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREA AT AF STATION AMBALA UNDER GE AIR FORCE AMBALA
2020_MES_373195_1
CA NO CWE/AF AMB/AMB-32/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE AF AMBALA
All contractors enlisted with MES in Class D and above and Category bii and for unenlisted refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE AF AMBALA
₹88,000
Yes
26 Oct 2020
29 Aug 2020
1 Oct 2020
29 Aug 2020
29 Sept 2020
16 Sept 2020
29 Aug 2020 - 8 Sept 2020
60 days
Amount
Demolition of existing unserviceable cross arms made of channels, angles including FI clamps, nuts, bolts etc fron OH line complete all as specified and as directed.
Dismantling carefully the existing unserviceable HT/LT overhead line ACSR conductor, of any size, from any position sfter necessary disconnecting of conductor complete all as specified and as directed
Dismantling & disconnecting electric connections of underground HT,XLPE cable,11 KV upto 300 Sqmm, from both sides and locating the fault in cable with fault locating machine in the entire length, removing moisture from cable, charging the HT cable with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified and as directed
Taking down/out burned HT/ LT winding, cleaning all the limbs replacing with new winding of super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, replacing insulating material including nuts,bolts & washers etc complete all as specified and as directed..
Re-stretching of GI rearth wire including binding on insulators with and including providing aluminium tapes complete all as specified and as directed..
Re-stretching of ACSR conductor with and including binding of stagged loose conductors, of any type fixed on LT poles, at any locations including tightening the cross arms ( three lines of ACSR conductor shall be measured as One length) complete all as specified and as directed..
Dehydration and filteration of transformer oil by using dehyderation and filteration plant, heating and filteration of oil to be carried out till the di-electric strength reaches 40 to 60 KV withstand for one minute is achieved, for any capacity of transformer including testing of oil complete all as specified and as directed . Notes :- Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work.
Overhauling VCB/TEE by checking of complete system, detecting faults /defects, replacing defective spare parts, checking hardwares for tightness, clean & lubricate soring guide & guide bolts, checking the trip , closing coil plunger is moving freely, check the electrical contacts are clear intact, clean the insulators,checking the lock nut, tighening the mechanical parts, adjustment of trollys etc complete all as specified and as directed.. Note :- Accessories & spare parts shall be measured and paid seperetely under respective items.
Excavation in trenches not exc 1.5mtr wide and not exc 1.5mtr in depth for laying of cable, errection of poles, struts/stays, levelling of yard etc not exc 10 sqm on plan and getting out, in soft/loose soil complete all as directed
Excavation in trenches not exc 1.5mtr wide and exc 1.5 mtr but not exc 3.0 mtr in depth for laying of cable, errection of poles, struts/stays, levelling of yard etc not exc 10 sqm on plan and getting out, in soft/loose soil complete all as directed
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each complete all as specified and as directed.
Removal of surplus soil to a distance not exc 500 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover , Class HV type-1 with flat, size 250mmx180mmx40mm for protection of cable complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregates as in foundation to pole/stays/struts etc complete all as specified & as directed.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in coping/padestal to pole/stays/struts etc with & including necessary form work with fair finished to exposed surfaces without using extra cement complete all as specified & as directed.
Supply and fixing cable route indicator made of cast iron & embedded HT cable on 5 mm thick plate of size 80 mm dia including grouting the lugs of suitable size, grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates block of size 150 mm x150mm x150mm in foundation including necessary form work including taking down of existing complete all as specified & as directed.
Dismantling old unserviceable gang operated air breaker switch from two pole / four pole structure, and Supply and fixing of gang operated air breaker switch ,triple pole, mechanically operated , mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 amps, out door type (confirming to IS specifications) HT 11 KV , triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse Assembly , Fuse carrier fitting , 12 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and as directed.
Dismantling old unserviceable gang operated air breaker switch from two pole / four pole structure, and Supply and fixing of gang operated air breaker switch ,triple pole, mechanically operated , mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 400 amps, out door type (confirming to IS specifications) HT 11 KV , triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse Assembly , Fuse carrier fitting , 12 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning of HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 95 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking down of existing cable complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning of HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 120 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking down of existing cable complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning of HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 240 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking down of existing cable complete all as specified and directed. NOTES for srl No 20 & 22 : (i) Cable shall be of manufacturing date not earlier than Jun 2020. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Cable shall be tested in the presence of GE after laying in the trench before returning filling in the trench. (iii) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately. (iv) No straight through joint shall be permitted in less than single drum length. (v) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for indoor termination heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for indoor termination heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 300 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for outdoor termination heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for outdoor termination heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 300 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for straight through heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for straight through heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV earthed grade cable for straight through heat shrinkable type joints with jointing material and accessories for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sq mm including cutting after taking down/out kit as existing at site complete all as specified and as directed.
Supplying and errecting true vertical or to be planted as strut steel tubular, swaged welded pole conforming to IS-2713 part II ,type 410 SP 55, 11.0 metre long complete with mild steel base plate of 6 mm thick of size 300 X 300 mm, finial taper plug, cap, bolts, nuts, washer and screws. hole of required size and Nos for fixing cross arms including painting with two coats of aluminium paint over a coat of red oxide primer for exposed surface and two coats of black bituminious paint for embeded portion in concrete after taking down/out pole as existing at site complete all as specified and as directed.
Supplying and errecting Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 conforming to IS-1678, provision of precast holes in PCC poles for fixing 'D' iron, clamps and hooks for continuous G.I. earth wire etc. to the required size with bolts, nuts, washers etc with & including refixing light fittings with old retrieved GI brackets by providing new MS clamps with nuts , bolts & washers duly painted the entire steel and iron surfaces , testing & making necessary connections to make the security light fitting functional after taking down/out pole as existing at site complete all as specified and as directed. Note for srl No 30 & 31 :- Excavation and earth work and PCC shall be measured and paid separately.
Supply and fixing ACSR conductor,steel reinforced, Weasel,Beaver, Ferret,Mink including stretching on insulators on poles with minimum sag including binding wore , jointing sleeves, aluminium tap & PG clamps of suiatble size complete all as specified and as directed. Notes :- The rates quoted includes (i) Jumper on cutout point,2 pole/4 pole structure shall be provided with PVC sleeves . (ii) Cutting of branches of trees coming across the OH line.
Supply and fixing Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade after taking down/out insulator as existing at site complete all as specified and as directed.
Supply and fixing Loop type insulator, vitreous porcelain, white, brown or green,small size, with overall dimensions 65 x 90mm, clearance of hole 16mm after taking down/out insulator as existing at site complete all as specified and as directed.
Supply and fixing post insulator, 11000 volts grade for gang operated air breaker switch including necessary nuts, bolts & washers after taking down/out insulator as existing at site complete all as specified and as directed.
Supply and fixing male contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers after taking down/out contacts as existing at site complete all as specified and as directed.
Supply and fixing female contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers after taking down/out contacts as existing at site complete all as specified and as directed.
Supply and fixing Disc type insulator, porcelain, vitreous 145mm high and 255 mm dia ball and socket type, white, brown or green,two-in-series' assembly for tension with tension clamps for conductors,working pressure 11000 volts, with and including one galvanized mild steel spindle, two GI washers with one GI nut after taking down/out insulator as existing at site complete all as specified and as directed.
Supply and fixing stay wire galvanised iron stranded of size 7/4.0 mm including taking down of existing complete all as specified and as directed.
Supply and fixing cradles guard,hexagonal/rectangular fabricated with galvanized stay wire of 4.0 mm dia including taking down of existing complete all as specified and as directed.
Material and labour for drawing GI steel earth wire of 4.0 mm dia on existing steel/PCC poles including binding on insulators with aluminium taps,jumpers etc including taking down of existing complete all as specified and as directed.
Material and labour for jumpers made of squirrel ACSR conductor, 2 mtrs long including standard PG clamps in design of two aluminium alloy halfs with two or more galvanized steel bolts fixed at one end, the jumpers will be wrapped with PVC sleeves 15 mm dia in different colours complete all as specified and as directed.
Supply and laying stay assembly complete with accessories comprising of stay wire 7/2.50 mm dia, 1800 mm long ,MS galvanised stay plate 6 mm thick of size 300x300 mm stay bow including loop type insulator porcelain viterous 90x140 mm clearance hole 25 mm as shown in electrical plate No. 1 including taking down of existing complete all as specified and as directed. Note :- Stay clamps, excavation and earth work and concrete shall be measured and paid separately.
Supply and fixing cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed with and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in replacement lightening arrestor (set of three), expulsion type,11000Volts,15 kA discharge capacity with all fittings, complete all as specified and as directed.
Supply and fixing in replacement danger notice board of 1.6 mm thick mild steel sheet,vitreous enamelled white,with letters ,figure and conventional skull and bones in signal red colour, fixed with MS clamps ,bolts and nuts,for PCC pole/tubular pole/panel for 1100 volts grade, of 25x20cm size including taking down of existing complete all as specified and as directed.
Supply and fixing anti climbing device ,spikes type fabricated out of MS bars ,round square and flat with and including providing required nuts ,bolts,washers etc., welding in two halves, made to shape, to suit the cross section of the pole and applying two coats of aluminium paint over a coat of red oxide after taking down/out existing complete all as specified and as directed.
Material and labour GI pipe 80 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection including taking down of existing complete all as specified and as directed .
Material and labour GI pipe 100 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection including taking down of existing complete all as specified and as directed . Note for srl No 48 & 49 :- Excavation and earth work shall be measured and paid separately
Cleaning and preparation surfaces of HT/LT steel tubular poles and M&L for applying two coats of aluminium paint over a coat of red oxide primer to poles,to cross arms, brackets, hooks, junction box, stay clamps with and including making blue & white strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified and as directed.
Cleaning and preparation surfaces of HT/LT PCC poles and M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer to poles with and including applying two coats of aluminium paint over a coat of red oxide primer to cross arms, brackets, hooks, junction box, stay clamps , and making blue & white strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified and as directed.
Supply and fixing in replacement epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/50/05 VA for 11 KV complete all as specified and as directed..
Supply and fixing in replacement epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 50/25/05 VA for 11 KV complete all as specified and as directed..
Supply and fixing Drop out fuse 5 to 20 Amps in existing GOD , at any location after taking down/out fuse as existing at site complete all as specified and as directed.
Supply and fixing DC power pack, AC input 90 V-270 Volots, battery-7 AH/24 Volts, 50 Hz, output voltage 26.5 VDC +/- 5 % V after taking down/out pack as existing at site complete all as specified and as directed.
Servicing of ACB 630/800/1200 amps rating by disconnecting incoming & outgoing cables, overhauling the all spare parts, greasing etc with & including replacenment of worn out minor spare parts, tighening of all nuts, bolts etc complete all as specified and as directed.
Supply and fixing in replacement defective LT side stud of gun/brass metal of size,make, specifications as exists for transformer of capacity 500 to 630 KVA with & including replacement of nuts, botls & washers etc complete all as specified and as directed..
Supply and fixing in replacement defective LT side stud of gun/brass metal of size,make, specifications as exists for transformer of capacity 300 to 400 KVA with & including replacement of nuts, botls & washers etc complete all as specified and as directed..
Supply and fixing in replacement defective LT side stud of gun/brass metal of size,make, specifications as exists for transformer of capacity 160 to 250 KVA with & including replacement of nuts, botls & washers etc complete all as specified and as directed..
Supply and fixing in replacement defective LT side stud of gun/brass metal of size, make, specifications as exists for transformer of capacity 50 to 150 KVA with & including replacement of nuts, botls & washers etc complete all as specified and as directed..
Supply and fixing in replacement defective /cracked HT/LT side bushes of size, make, specifications as exists at site to make the equipment functional complete all as specified and as directed..
Supply and fixing in replacement deterioted HT/LT bushing rubber ring gasket set of size, make, specifications as exists at site to make the transformer functional complete all as specified and as directed..
Supply and fixing in replacement deterioted transformer top gasket, cork sheet of transformer set of size, make, specifications as exists at site to make the equipment functional complete all as specified and as directed..
Supply and fixing in replacement silicagel in sealed bag of make, specifications as exists at site complete all as specified and as directed..
Supply and fixing in replacement PVC air breather of make & specifications as exist at site filled and with & including silica gel suitable for upto 100 KVA transformer complete all as specified and as directed..
Supply and fixing in replacement PVC air breather of make & specifications as exist at site filled and with & including silica gel suitable for 100 KVA to 200 KVA transformer complete all as specified and as directed..
Supply and fixing in replacement PVC air breather of make & specifications as exist at site filled and with & including silica gel suitable for 250 KVA to 500 KVA transformer complete all as specified and as directed..
Supplying, filling and pouring transformer oil ,ISI marked ,in sealed container conforming to IS-335, with di-electric strength of 50 KV including testing and draining out existing oil complete all as specified and as directed..
Supply and fixing in replacement TNC switch of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement closing coil assembly of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement tripping coil assembly of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement indicator bulb 20 watts, 1100 volts of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and as directed.
Supply and fixing in replacement isolating contact assembly ,set of 6, of make,specifications as exists at site, suitable for VCB 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed.
Supply and fixing in replacement earthing contact assembly , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement Drive link assembly with adjuster ( set of three) of make,specifications as exists at site, suitable for VCB 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed.
Supply and fixing in replacement Motor with gear assembly , single phase, 230 volts , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement breaker phase barrier of make,specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement Motor charged mechanisam assembly with close/trip coil & charging handle , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement contact system for VD4, 400 A (12 finger), of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement potential transformer of fixed type,3 phase,3 limbs with HRC fuses mounted, of make, specifications as exists at site, suitable for VCB 11000 Volts,400 amps including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement of base assembly suitable for VCB 11000 Volts,400 amps, of make, specifications as exists at site, including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement digital ammeter with shunt suitable for VCB11000 Volts,400 amps, of make, specifications as exists at site, including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement Digital frequency with shunt suitable for VCB 11000 Volts,400 amps , of make, specifications as exists at site, including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement of IDMT relay with numerical relay for VCB tripping system (3 OC + 01 earth fault & high set instantaneous protection in single unit) suitable for operation on 24 V DC all as per model No CGII4N of CG or in Areava complete all as specified and as directed.. Note :- Existing relay are IDMT type electromagnetic type hence any modification in the wiring & panel sheet enclosure required is deemed to be included in the quoted rates.
Taking down and opening of defective transformer from existing position, of any type, of any make,of capacity 500 KVA to 630 KVA for repair including transporting to authorised workshop, opening up for inspection to assess the repair required, making joint inventories to carry out repair, cleaning, greasing & overhauling with and including taking out and replacement of unserviceable/ worn out parts with new parts, fixing parts, detanking , labour for refilling of transformer oil after repairing/dehyderation, re-assembling after repairs, bringing back to the location where equipment was installed, fixing in original position, connecting,installation & testng on full load capacity & commissioning complete all as specified and as directed.
Taking down and opening of defective transformer from existing position, of any type, of any make,of capacity 300 KVA to 400 KVA for repair including transporting to authorised workshop, opening up for inspection to assess the repair required, making joint inventories to carry out repair, cleaning, greasing & overhauling with and including taking out and replacement of unserviceable/ worn out parts with new parts, fixing parts, detanking , labour for refilling of transformer oil after repairing/dehyderation, re-assembling after repairs, bringing back to the location where equipment was installed, fixing in original position, connecting,installation & testng on full load capacity & commissioning complete all as specified and as directed.
Taking down and opening of defective transformer from existing position, of any type, of any make,of capacity 160 KVA to 250 KVA for repair including transporting to authorised workshop, opening up for inspection to assess the repair required, making joint inventories to carry out repair, cleaning, greasing & overhauling with and including taking out and replacement of unserviceable/ worn out parts with new parts, fixing parts, detanking , labour for refilling of transformer oil after repairing/dehyderation, re-assembling after repairs, bringing back to the location where equipment was installed, fixing in original position, connecting,installation & testng on full load capacity & commissioning complete all as specified and as directed.
Taking down and opening of defective transformer from existing position, of any type, of any make,of capacity 50 KVA to 150 KVA for repair including transporting to authorised workshop, opening up for inspection to assess the repair required, making joint inventories to carry out repair, cleaning, greasing & overhauling with and including taking out and replacement of unserviceable/ worn out parts with new parts, fixing parts, detanking , labour for refilling of transformer oil after repairing/dehyderation, re-assembling after repairs, bringing back to the location where equipment was installed, fixing in original position, connecting,installation & testng on full load capacity & commissioning complete all as specified and as directed. Notes for srl No 87 to 90 :- (i) Spare parts shall be measured & paid seperetely.(ii) All parts/components replaced shall be identical to those specified by original manufecturer. (iii) Cost of winding shall be measured & paid seperetely.
Supplying, installation, testing and fixing VCB trolly, 400 amp, rating 11000 Volts with and including the following features, after taking down/out trolly as existing at site complete all as specified and as directed :- (a) Mechanical inter locking and automatic safety shutter gear with and including pad locking arrangment -01 No. (b) Isolating plugs-06 Nos. (c) 01 No 18.5 kA at 11 KV, 400 amps VCB, comprising of the following:- (i) Assembly of 3 vaccum interupters complete with expoxy support insulator and self aligning finger type isolating contract. (ii) Hand and motor,220 volts AC charged independent spring closing/ tripping, trip free operating mechanism with manual closing &tripping push buttons and mechanical breaker closed/open, spring charged/discharged indication. (iii) Mechnical operation counter Make-CG/ABB (As per sample). Notes:- (a) The contractor will be fully responsible for the functionabily of VCB (b) The contractor will visit the site to ascertain the quality required,before placing the order.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth wire 4.0 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth lead strip 32x6 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed. Notes for srl No 92 & 93 :-- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance is not obtained, earthing will be generated at NO extra cost ,till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 0.5 mtr away from the earth electrode.
Cutting/ Lopping of tree branches of any thickness from any height and type of trees in route of 11000 volts HT OH lines using suitable T&P and removal of cut branches from site to distance exc 250 mtr complete all as specified and directed. Note :-The tree branches shall be 2 mtr away from the outer conductor of OH lines after cutting.
Deduct total amount of Credit Rs 317095.00
Saurav Enterprises
Raman Electric Trading Co
M/S Sonu Traders
R D Bansal
NAVREET CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .