Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.1 L+₹54,486.79 (1.17%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹47.2 L+₹64,921.63 (1.39%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹47.8 L+₹1.2 L (2.50%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹48.1 L+₹1.5 L (3.29%)Rejected-Finance HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
2 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Manish Kumar, IDSE, Garrison Engineer
GE Navy Porbandar Tija Mile Porbandar
CERTAIN REPAIR / REPLACEMENT OF B/R AND E/M INFRASTRUCTURE DAMAGE DURING CYCLONE BIPARJOY AT INS DWARKA OKHA UNDER GE NAVY PORBANDAR
2024_MES_635744_1
8845/Okha/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹90,000
Yes
22 Feb 2024
4 Jan 2024
5 Feb 2024
4 Jan 2024
2 Feb 2024
19 Jan 2024
5 Jan 2024 - 18 Jan 2024
Amount
Demolition of stone/boulder masonry, built in cement mortar incl coping etc all as specified and as directed by Engr-in-Charge.
M & L for walling of Porbandar stone masonry well bonded and solidly hearted built in CM 1:6 complete all as specified .
M&L for walling of except stone masonry well bonded and solidly hearted built in CM 1:6 complete all as specified .
Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scrubbing down with water, etc. and rubbishing off the premises, etc. complete
M & L Rendering 10mm thick in CM 1:6 on fair faces of stone masonry work or concrete surfaces finished even and smooth without using extra cement, Complete all as specified and directed.
M&L for preparing of newly plastered surface of walls and applying one layer 1 mm of white wall care putty and two coats of oil bound distemper over a coat of primer etc complete
M&L for rendering 10 mm thick in CM 1:3 on ceilings finished even and smooth without using extra cement.
M&L for preparing of new plastered surface and applying three coats of white wash in ceiling
M&L for rendering cement plaster 15mm thick in cement mortar (1:4) on brick work or concrete surfaces using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
Supply only, integral water proofing compound.
Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. complete all as specified.
M&L for Repairing the damp wall by removing the existing putty till plaster level from skrting to the affected area covering an aditional 0.3 meter distance across all sides of affected area. The smartcare hydroloc is applied on plaster by brush ensuring the material goes inside the pores/intersites. The first coat( no dilution) is applied with a forced coverage 3.7 -4.2 Sqm/L area from skirting to the affected area, covering an additional 0.3 meter distance across all sides of affected area. Allow it to dry for 6-8 hrs. The second coat ( no dilution) applied with coverage of 3.7 -4.2 Sqm/L perpendicular to first coat. Allow it to dry for 6-8 hrs. After it has dried water proofing putty is applied. Now the surface is prepared by sand paper to receive the colour over it complete all as specified and directed by Engineer-in-Charge. Note:- Asian Paint Smart care Hydroloc Product code 1A76 or equivalent in Nerolac / Berger / Dulux
Dismantling water proofing membrane Textile coverings including frames (if any) and cover fillets (measured flat and not girthed) complete all as specified and directed.
M & L for Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately).
M & L for Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions.
M & L for Preparation of New/ previously untreated surface of APP membrane and painted with two coat of aluminium paint all as specified and directed by Engr-in-charge
Dismantling wrought iron or mild steel work of any description not otherwise described for of any description.
M & L for mild steel Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing(Beam, tee, angle, channel or flat section) including distance pieces, cleats, also in protecting the overhead water tanks aganist wind pressure by forming the grid etc Fe 410-W (Gde-E-250) quality-A.
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including ridge etc complete
M & L for High tensile galvalume sheets colour coated single skin high rib / multi rib TMP Profile Galvalume sheeting in roof having 1000-1020 mm width 28 mm high crest @ maximum 250 mm pitch (centre to centre) and minimum 190mm manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyester paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F in repair 5mm thick solid polycarbonate sheet of colour as approved and fixed in roofs , wall cladding etc screw bolts as per manufactures instructions complete all as specified and and directed by Engineer-in-Charge
Taking down aluminium windows/ door frames incl shutters (without taking off shutter) complete of size n exc 1.5 sqm area all as specified
S& F powder coated aluminium frame and shutters for doors, windows, partitions, ventilators with one or more rebates including joining cleat and necessary fittings of premium quality (handle, locking arrangement, stoppage) for fixing etc. complete all as specified
S&F 5.5 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane all as specified
S&F 4 mm thick Figured glass, pin head type and glazing with aluminium snap beading with rubber Neoprene packing in square n exc 0.5 sq. m in each pane all as specified
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire stapple or wooden beading to any type of shutter complete .
Taking down aluminium decogrill of any size and any type all as specified
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104 5.5mm to 6.5mm thick with necessary channels and clips complete all as specified and as directed
Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000 ltrs.
Dismantling water tanks and removing to store of capacity exc 250 & n.exc 500 ltrs.
S & F 1000 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed.
S & F 500 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed.
S & F 25 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut.
S & F in repairs 25 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut.
Cleaning and removing all scale and dirt etc from tanks & from mouths of circulating pipes etc of service water/loft tanks in / over roof buildings at different locations of capacities as under:
Capacity exceeding 250 but not exceeding 500 litres each
Capacity exceeding 501 litres but not exc 1000 litres each
Capacity exceeding 1001 litres but not exc 2000 litres each Note for item No. 38: 1. The contractor will write date of cleaning& next due date of cleaning on Tank as directed by the Engr-in-Charge. 2. At the time of cleaning disconnected pipes/fittings shall be reconnected as per existing to make it leak proof complete all as directed by the Engr-in-Charge.
S & F HDPE PVC lid (cover) with locking arrangement for 500/1000 Ltrs capacity PVC tank fixed in repair / replacement complete all as specified and directed.
Taking up or down UPVC tubing 20mm bore pipe and connections complete all as specified and as directed by Engineer-In-Charge.
Taking up or down UPVC tubing 25/32mm bore pipe and connections complete all as specified and as directed by Engineer-In-Charge.
S & F of UPVC tubing, 20mm bore, including complete cleaning of pipe and fitting such as bends, tees, elbows, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors) complete all as specified and as directed by Engineer-In-Charge.
S & F of UPVC tubing, 25mm bore, including complete cleaning of pipe and fitting such as bends, tees, elbows, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors) complete all as specified and as directed by Engineer-In-Charge.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts/scaffolding all complete as per direction of Engineer-in-charge.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-in-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20sqm/kg of approved make
M & L for providing and applying jacketing around columns,beams, including all necessary scaffolding, shuttering,drilling holes or welding to existing reinforcement and fixing shear anchor as per manufacturer's specification all complete. Note : Reinforcement shall be measured and paid separately
Providing and applying polymer based bonding coat of pagel U10 of PIDILITE/BASF/SIKA/FOSROC or Equivalent make on cleaned / washed surface of concrete and applying pre -packed polymer modified repair mortar pagel U10/U40 of PIDILITE / BASF / SIKA / FOSROC or Equivalant as per ASTM / BS standards having comp. strength of 45 MPa. min at 28 days, Adhesive bond not less than 02 MPa, Chloride content less than 0.05% & Flexuural Strength of 8mpa min at 28 days in all respect as per manufacturer's recomendations and relevant codes, including the required material, manpower, Application and tools & tackles all complete as per direction of the Engineer - in - charges.
Providing and fixing hard drawn steel wire fabric of size 25x25mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
Providing and laying in position Micro - Concrete as per relevant ASTM / BS / IS having comp. strength of min 45 mpa at 2 days of make PIDILITE/ BASF/SIKA/FOSROC or equivalent in columns and beams, which shall be pre-packed single component, chloride free, non shrink, free flow, self compacting and mixed as per manufacturere spacification, including required leak proof shuttering, pre - soaking of substrate, manual application or pumping, manpower and tools & tackles all complete as per direction of the Engineer - In - Charge.
M&L CRS reinforcement bars 10mm and over using cut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete.
Ditto as above item No 50.00 but 5mm dia and over upto and including 10mm dia in stirrups.
S&F in repairs Steel rolling shutters, with ball bearing, as specified including top cover, an- choring rod, hasp and staple and one shop coat of primer; erected in position as indi- cated, complete: gear operated type with bevel gear box and crank handle all as directed. (Thickness of laths 1.25mm)
S&F Safety lever locks mild steel with 4 levers for rolling shutters
S&F Ball bearing for rolling shutters
M & L for 4mm thick ACP panel cladding, fixing on vertical or horizontal MS frame work and filling silicon gel in groves including fixing of Screw gaskets, bolts washers complete all as specified and directed.
M & L for Stainless Steel letters/ emblem to be fixed in approved design and patterns having letter size not less than 30cm in width 45cm in height , fixing on vertical or horizontal MS frame work and filling silicon gel in grooves and holes including fixing necessary screws and fastening complete all as specified and as directed. Note : MS work will be measured and paid separately.
Taking down chowkats or frame of any description n exc 1.5 Sqm each (without taking off shutters from the frames) removing to or from store complete as specified and directed.
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specifications and drawings complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification & drawing complete all as specified and directed by Eng-in-Charge.
Taking down chowkats or frame of any descrip tion exc 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) complete as specified and directed.
S&F 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed
S&F 35mm thick Factory made second class HW in glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed by Eng-in-Charge.
S&F 35mm thick Factory made 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mmB.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to wooden door Shutters/aluminium sliding shutters with required beading complete all as specified and directed.
M & L for preparation of new wooden surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as all as specified and directed.
S&F, 250mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 150mm size, aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F aluminium, anodised barrel tower bolt of extruded section and fixed 200 mm of size
S&F 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
M&L and Repair/Replacement for erecting of steel tubular swaged poles swan neck type complete with cast iron base plate, finial taper plug, Cap, mild steel bolts, nuts,screw, etc. type 410 SP-31(9.0 meters long) complete all as specified and directed.
M&L and Repair/Replacement for erecting of Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete all as specified and directed.
Supply and Repair/Replacement of hot press moulded SMC junction box door fixed with left side hinged inside dimension of 240x130x95 mm Fixed with cable terminals with one number of 16 Amp SP MCB incl fixed on pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.Make-Sintex/Hensal
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge
Supply and Repair/Replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tighteni the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings.
Supply and Repair/Replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tighteni the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings.
Supply and Repair/Replacement of Garden Bollard light BGBOM 650 8W LED Bollards light Die cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including including taking down the u/s street light fittings complete all as specified and as directed.Catpart No. BAMBOOBL8WLED857PSYMTOPCM of Havells Make- Bajaj/C&S/Wipro
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core complete all as specified and directed Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core complete all as specified and directed Engr-in-charge.
Supplying and laying repair/replacement of CPVC pipe SDR 11 & Plain CPVC SDR 11 of 25mm outer dia of of pipe including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position in trenches, walls, floors etc complete all as specified and directed.
Supplying and laying repair/replacement of CPVC pipe SDR 11 & Plain CPVC SDR 11 of 40mm outer dia of of pipe including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position in trenches, walls, floors etc complete all as specified and directed.
Sypply and Repair/Replacement of 3 layer PP-R pipes of dia 25mm SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for Hot & Cold water supply all PP-R plain and brass threded polypropylene random fittings concealed/ laid to walls, ceiling or in floor etccomplete all as specified and directed.
M&L in replacement GI tubing medium grade galvanised with all fittings, Bends etc fix to wall and ceiling/lead on floor of UG sump, complete incl dismantling old pipes of any length for 80 mm dia bore sizes
S&F in replacement Condensing coil suitable for window type AC 1.5/2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton
S&F in replacement Condensing coil suitable for split type AC 1.5TR/2.0TR including taking out unserviceable Condensing coil of capacity 2 ton.
S&F in replacement outdoor unit suitable for 2.0TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for 1.5TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor complete.
S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 4.0 Sqmm complete all as specified and directed. Make : Polycab/Havells/Plaza
S&F in replacement AC stand suitable for out door AC unit up to cap of 1.5/2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and as directed by Engr-in-charge. .
Taking down burnt/ damaged ceiling fan/exhaust/air circulating fan of any size or make by disconnection eletric connection and handover to MES Store yard complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
Repair/Replacement of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete including connecting up with 3 core cord flexible from ceiling rose to exhaust fan etc. all as speified and directed by Engr-in-charge.
Repair/Replacement of Wall mounted fan white in colour 450mm sweep 3/4 blades complete all as specified and as directed.
Supply and Repair/Replacement of battary 12 volts 80 AH capacity suitable of solar light complete all as specified and directed by Engineer - in - Charge. Make: Exide/Luminious
Supply and Repair/Replacement of of Vacuum solar tube suitable size of existing storage type solar water heater 200 to 500 LPD of compatible type including making all connections by replacing old vacuum tube all as directed by Engineer - in - Charge.
Supply and Repair/Replacement of heating element 1.5/2 KW of sutable size of existing storage type solar water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge.
Supply and Repair/Replacement of Lightning conductor Air termination, single pointed Copper rod of 12 mm dia and 300 mm long inclduing fixing of MS Clamps, fixing screws all as specified and as directd and conforming to IS 2309 complete all as directed by Engineer-in-Charge.
Supply and Repair/Replacement of Copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground with the help porocelin insulator complete all as specified and as directed.
Supply and Repair/Replacement of test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
Supply and Repair/Replacement of poroceline insulator for laying of ligtning strip on the roof/ wall for maintain distance from suface and strip of suitable size and distance between two insulator minimum 1mtr complete all as specified and directed.
M & L for Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Excavation in trenches in Hard/ dense soil n exc 1.5 m wide and n exc 1.5 m deep and getting out, required to repair the leakage of CI pipes & fittings,including demolition of PCC/road cutting and making good to match the existing surface after repair works complete all as specified and directed
Returning, filling in including spreading levelling, watering and well ramming in layers n exc 25 cm using hard dense soil obtained from excavation complete all as specified and directed.
Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate for coping of pole around pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate for base foundation of pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C1 using 20 mm graded stone aggregate for foundation of pole around pole all as specified and as directed by Engineer-in-Charge.
Cutting of hard standing/ Road for laying of pipe line and making good surfaces by using PCC 1:2:4 type B-2 after laying of pipe line/ cable up to 30cm in depth and width not exceeding 45cms and removing rubbish outside MD land complete all as specified and as directed.
JAY BHARAT METAL SUPPLIERS
SURESH ELECTRICALS
vishot construction
K B N TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .