| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC H NO 765 VPO BIHTA TEHSIL BARARA DISTRICT AMBALA 133101 | AMBALA | AMBALA | HARYANA | 133101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹13.1 L+₹80,221 (6.53%)Rejected-Finance AGGARSAIN CHOWK VILLAGE BHOJPUR POST OFFICE FETEHPUR SAHARANPUR ROAD YAMUNANAGAR HARYANA 135101 | YAMUNANAGAR | HARYANA | 135101 | L2 | Rejected-Finance Highest | |
| 3 | L3₹14.0 L+₹1.7 L (13.8%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L3 | Rejected-Finance Highest |
Tender Value
₹12.1 L
EMD Value
₹24,180
Closing Date
23 May 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of Bus Stand at village Jansui Head in Ambala District. (Honble C.M Announcement vide Code No. 19769, dated 31072017) (Pdg. E.I and Estate work).
2022_HRY_220331_1
PWD/Elect-KNL/Elect-AMB/110258
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹24,180
Yes
11 Jul 2022
10 May 2022
24 May 2022
10 May 2022
23 May 2022
10 May 2022
120 days
Amount
1.5 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable. EL003
2.5 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable. EL004
4.0 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable. EL005
Supply, Erection, Testing of Ceiling Fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of engineer-in-charge. 48" (1200mm). HSR No. 20.71.1
Supplying, erection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable GI sheet ducting in structure confriming to latest IS specifications complete in all respect to satisfaction of engineer-in-charge. HSR No. 20.72.
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B HSR No. 23.2.1
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B HSR No. 23.2.4.2
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLs copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B HSR No. 23.2.5.2
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. HSR No. 23.6.6.1
MS pipe of 25 mm dia. HSR No. 23.6.6.2
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR No. 23.7.6.2
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR No. 23.8.11.1
15 amp 1 way switch HSR No. 23.8.11.3
5 amp Socket HSR No. 23.8.11.4
15 amp 6 pin Socket HSR No. 23.8.11.5
step type Fan Regulator 2 modules 300 watt HSR No. 23.8.11.7
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp HSR No. 23.22.1.3
4 pole MCCB 6 amp to 100 amp HSR No. 23.22.1.9
4 pole MCCB 200 to 250 amp HSR No. 23.22.1.11
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR No. 23.22.2.1
MCCB up to 250 A FP HSR No. 23.22.2.2
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.5
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) HSR No. 23.22.4.7
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts HSR No. 23.22.8.2
MS STAND, BUS BAR CHAMBER AND PANELS Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. HSR No. 23.24.1
Supply and election of Goodridge Almirante type M.S. pedestal made of 50 mm *50 mm * 6 mm angle Iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and looking arrangement with the Godrich type handle including round bars. The to covering should have a downward overhang of 75 mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides, at top and bottom, each set containing four No’s. holes to discharge the heat produced by suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block, projected 75 mm all around the pedestal and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in charge of the work. M.S. pedestal of size 750 mm wide, 900 mm high, 300 mm deep and bottom totally open , duly embedded in cement concrete block of size 900 mm*450 mm*200 mm above ground level , having a base of size 1050 mm* 600 mm* 250 mm below ground level. HSR No. 23.27.2
CHAPTER 24.0 - CABLE LAYING AND STREET LIGHTING EARTHING AND LIGHTENING ARRESTOR Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR No. 24.1.1
Extra for using salt and char coal/coke for pipe earth electrode as required. HSR No. 24.1.2
Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR No. 24.1.3
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR No. 24.1.5
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR No. 24.1.7
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 24.1.8
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR No. 24.1.11
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required. HSR No. 24.1.13
Laying of underground cable in pipe /existing open/closed tench tc as required:- 2.5 Sq mm to 10 Sq mm 2 to 4 Core HSR No. 24.2.2.1
16 Sq mm to 35 sqmm 2 to 4 Core HSR No. 24.2.2.2
50 Sq mm to 150 sqmm 2 to 4 Core HSR No. 24.2.2.3
Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 1.5 sqmm HSR No. 24.2.6.1
4 sqmm HSR No. 24.2.6.3
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core HSR No. 24.2.7.3
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm HSR No. 24.2.8.3
25 sqmm HSR No. 24.2.8.5
Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A bakellite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on bakellite sheet in the M.S. box including painting and necessary connections. HSR No. 24.4.5
B.S.E.N. 10025 High Masts Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip , galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 no’s. luminarie loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 no’s steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete I all respect upto entire satisfaction of Engineer-in Charge.Thickness of Top and Bottom Section = 3 mm & 4 mm (minimum). Top Dia = 150 mm and Bottom Dia = 410 mm. Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum) HSR No. 24.4.15.2
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR No. 24.5.2.3
DWC/HDPE pipe 63/50 mm outer dia/inner dia RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16m high mast pole HSR No. 24.9.2
M.S Pipe 65mm dia, HSR No. EL 272
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . Supply of 10Sq. mm 2 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, make Grandlay complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. Make Grandlay/Havells. NS-1.
Supply of 25Sq. mm 4 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, make Grandlay complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. Make Grandlay/Havells. NS-2.
Supply of 95Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, make Grandlay complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. Make Grandlay/Havells. NS-3
Supply & Erection of LED Batten 40 Watt, make as per approved list. complete with necessary connections complete in all respect including all material required to complete the job in all respect & up to the entire satisfaction of the Engineer in charge of the work. NS-4.
Supply and erection of 100W LED Flood light with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Surya / Bajaj/ Crompton/ Philips /Havells. NS-5.
Supply and erection of 200W LED Flood light with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Surya / Bajaj/ Crompton/ Philips /Havells. NS-6.
S/E of 63 amp. 3 Pole/230V Astronomical automatic time switch of Indo Asian make Cat No. TL065ASO alongwith contractor of required capacity movement controlled by preciosity quartz oscillation operation on main supply of continue to run on built in rechargeable nicket cadium cell for 150 hours in the event of power failure including cost of contractor complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. NS-7.
Radhey Krishan Enterprises
Som Nath Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .