Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-AOC H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹23.0 L+₹61,041.68 (2.72%)Rejected-Finance | 2 | Rejected-Finance Not Lowest Bidder | |
| 3 | 3₹24.6 L+₹2.2 L (9.67%)Rejected-Finance | 3 | Rejected-Finance Not Lowest Bidder | |
| 4 | 4₹25.8 L+₹3.4 L (15.3%)Rejected-Finance | 4 | Rejected-Finance Not Lowest Bidder | |
| 5 | 5₹26.2 L+₹3.8 L (17.1%)Rejected-Finance | 5 | Rejected-Finance Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
12 Oct 2020, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
PROVISION OF PACKING MATERIAL SHED NEAR BUILDING NO 74 AND 75 AND PROVISION OF CERTAIN SR/MINOR/REVENUE WORKS IN NORTHERN SECTOR AT MILITARY STATION KOTA
2020_MES_377820_1
8458/E8
Open Tender
Civil Works
Item Rate
243 days
Kota
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹77,000
Yes
28 Oct 2020
15 Sept 2020
13 Oct 2020
15 Sept 2020
12 Oct 2020
30 Sept 2020
16 Sept 2020 - 22 Sept 2020
Amount
Excavation in post holes (or similar holes) each n exc 0.50 Cum, getting out, returning filling in and ramming earth in layers not exceeding 25 cm,watering and removing surplus soil to a distance of n exc 50m and making good surface in soft/loose soil, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
M&L PCC 1:2:4 type B-2, using 40 mm graded stone aggregate, as in foundation filling, mass concreting etc, complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240, complete all as specified and directed.
Supply, fabrication and fixing MS tubes, medium grade with connecting plates as in posts and struts including cutting to shape, provided with necessary nuts, bolts, washers, welding etc, complete all as specified and directed.
S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed.
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed.
M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 mix, type B2 (using 40mm graded stone agg) as in path/hard standing/floor etc, finishing surfaces even and smooth without using extra cement, laid in panels, complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work new or old, like ends of posts, backs of chowkhats etc area exc 0.10 Sqm and n.exc. 0.50 Sqm and treating with tar or coal tar black paint, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removal to store, complete all as specified and directed.
S&F 15 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors, complete all as specified and directed.
S&F 20 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors, complete all as specified and directed.
Refixing old GI tubing with and including new GI fittings, 15 mm dia, in new or old position on walls, ceiling or floor, complete all as specified and directed.
Refixing old GI tubing with and including new GI fittings, 20 mm dia, in new or old position on walls, ceiling or floor, complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in flooring/sub base finished rough to receive floor finishes/screed, complete all as specified and directed.
M&L for non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surface in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for applying three coats of white wash on walls including preparation of new or previously untreated surfaces, complete all as specified and directed.
S&F in repair sink with draining board made of stainless steel 1mm thick with plugs, washers incl brackets of suitable angle iron, 32 mm dia superior quality PVC waste pipe, 32 mm dia CP brass waste coupling and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm, complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from wooden frame/steel frame, glazing with putty or fixed with beads, complete all as specified and directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed.
S&F in repair bib taps, cast copper alloy, with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket, complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F in repair 10 Ltr capacity PVC low level flushing cistern, top push type with inlet ball valve, PVC float etc. including superior quality PVC flush pipe of 32 mm dia, complete all as specified and directed.
Taking down and refixing in same/other position PVC low level flushing cistern of any type, complete all as specified and directed.
S&F in repair 17/18 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed to timber frame work, complete all as specified and directed.
S&F 100 mm long hasp & staple safty type anodised aluminium with mild steel hinge pin bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F 100 mm long mild steel cold rolled medium weight butt hinges, fixed with MS screws, complete all as specified and directed.
S&F PVC connection, 15 mm size with two PTMT nuts, length of connection 450 mm, complete all as specified and directed.
S&F in repair stop valve 15 mm nominal bore cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed, complete all as specified and directed.
S&F stainless steel utensil plate rack of size 600x600x250 mm with partition for small/large plates, fabricated out of Ist quality, 24 guage thick stainless steel sheet and fixed in position, design and pattern as approved by the GE, complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, laid over and including 25 mm thick sand cushion, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed), making groove in ground of desired dimension, placing in position and set and jointed in CM 1:4, making good disturbed surface of ground, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in soil including spreading, leveling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Demolition/Dismantling of existing normal roof treatment, any type from RCC roof slab including wire brushing and cleaning of foreign materials, loose dirt etc, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each, complete all as specified and directed.
Dismantling cast iron or reinforced concrete drain pipes 100 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Dismantling cast iron or reinforced concrete drain pipes 75 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting of any gauge/thickness from roofs and wall covering, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed.
S&F 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.
M & L for PCC 1:2:4 Type B-0 (using 12.50 mm graded stone aggregate) as in leveling course on roof/under floor finishes, complete all as specified and directed
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of RCC roof slab in CM 1:4 duly mixed with liquid water proofing compound, finishing surfaces even and smooth without using extra cement, complete all as specified and directed. (WPC shall be measured and paid separately).
M&L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces in CM 1:4 duly mixed with liquid water proofing compound, finishing surfaces even and smooth without using extra cement, complete all as specified and directed. (WPC shall be measured and paid separately).
Supply only approved liquid water proofing compound, complete all as specified and directed.
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish, reinforced with non-woven polyester mat with a thermo fusable finish, laid over compatible bitumen primer @ 0.40 Kg/Sqm, torching overlaps with propane or butane gas torch, with an overlap of 75mm at the sides and 100mm at the ends and sealing, complete all as per manufacturer’s instructions, specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm.
Item 62.00 Contd……. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane shall be inserted in groove and sealed with paving bitumen. (v) Cost of these factors shall be deemed included in the unit rates.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 10 mm thick CM 1:4 backing, complete all as specified and directed.
M&L for Udaipur green marble work 16 to 18 mm thick glazed (table rubbed and polished) fixed as in cooking plateform, steps, treads, risers, jambs, window cills etc and the like set in cement mortar 1:4 and pointed with white cement using marble dust with admixture of pigment to match the shade of stone, laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces in two layers, consisting of 10 mm thick in CM 1:6 and over that 5 mm thick in Cm 1:4 using water proofing compound as per manufacturer's instruction's, finishing surfaces even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L rendering 10 mm thick in CM 1:4 on concrete surfaces of ceiling, finished even and smooth without using extra cement, complete all as specified and directed.
M&L brick work with pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for brick work with pulverised fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan to any radius in half brick walls built in cement mortar 1:4, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary formwork to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, conforming to Fe 410 -W (GdeE- 250) quality A, complete all as specified and directed.
S&F welded steel wire fabric supplied and fixed complete to wood or steel members, weight per Sqm not exceeding 4.00 kg, complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) paneled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm, complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, including one shop coat of zinc chromate primer, complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of zinc chromate primer, complete all as specified and directed.
S&F steel windows or ventilators, fixed type with glazing bars, partly glazed and partly gauged, including one shop coat of zinc chromate primer, complete all as specified and directed.
S&F 300 mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed.
S&F Mild Steel bow handles, oval type, stove enameled black 150 mm long, complete all as specified and directed.
S&F for 150 mm mild steel barrel tower bolts, stove enameled black with bright bolts and fixed, complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolt clip type stove enameled black with bright bolt n.less then 12 mm dia and incl a minimium of 6 bolt & nuts, four for holding bolt clamps and two on staple plate, complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and fixed to walls, complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and fixed to walls, complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F PVC (SWR) bends of any radius, 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) bends of any radius, 110 mm bore, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) Tee single with oval access door, equal or unequal, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) Tee single with oval access door, equal or unequal, complete all as specified and directed.
M&L applying one coat of synthetic enamel paint after preparation of old previously treated iron/steel surfaces exceeding 10 Cm in width or girth, complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces, exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L applying one coat of synthetic enamel paint after preparation of old previously treated wooden/wood based surfaces exceeding 10 Cm in width or girth, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying 1 to 1.5 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
M&L complete removal of existing treatment from previously treated surfaces of walls and applying 1 to 1.5 mm thick Wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
M&L applying three coats of white wash after preparation of new plastered surfaces of ceilings, complete all as specified and directed.
M&L applying one coat of white wash after preparation of old previously treated surfaces of ceilings, complete all as specified and directed.
M&L for preparing new previously untreated plastered surfaces of walls and applying two coats of weatherproof modified exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treatment from old previously treated plastered surfaces of walls and applying two coats of weatherproof modified exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed.
S&F in repair stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
M&L PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
Demolition and breaking up drain pipes and fittings, salt glazed ware, AC, PVC or RCC, internal dia of pipe 150 mm, complete all as specified and directed.
M&L PCC 1:5:10 type E-2, using 40 mm graded stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, complete all as specified and directed.
M&L walling of random rubble (Except stone), uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, with maximum depression on face from straight edge held against the dressed surface not exceeding 20 mm; to block in course masonry (Lime or sand stone), complete all as specified and directed.
M&L PCC 1:3:6, type C-2 using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of 150 mm dia pipe, after they are laid and tested, complete all as specified and directed.
M&L 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
M&L precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in manhole/drain cover slabs, landing slabs, shelves and similar articles with plain faces, set in CM 1:4, with and including necessary Formwork, complete all as specified and directed.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
Disconnecting and taking down carefully ceiling fan/exhaust fan and refixing after cleaning, oiling/greasing and connecting with suitable size copper conductor cable, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including making good disturbed surface all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
One 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
One light point controlled by two, two way 5/6 Amp switches.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing switch socket combination, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
S&F bell push single pole, AC, 240 volts, 5/6 amps, complete all as specified and directed.
S&F electronic call bell ding dong type, 5/6 Amps, 230 volts AC, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
S&F wall mounted LED Tube light fittings, batten type with bipin holders, powder coated steel with retrofit 20 watt LED tube, internally prewired, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, complete all as specified & directed.
S&F MCB, 6 to 40 Amps, Single Pole, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S&F MCB, 63 Amps, Triple Pole & Neutral, 415 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 415 Volts TPN with 6 ways, Double door, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed. Note for item Nos 132 & 133 - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor complete all as specified & as directed. NOTE:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit. Cutting chases in walls shall not be measured and paid separately.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth strip of 25x4 mm size by means of bolts, nuts, check nuts and washers of galvanized iron including 32 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 5 and complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire/strip and earth strip upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
S&F LED security light fitting, 20 watt, pressure die cast aluminium housing with IP 66 deg of protection, complete with 1.20 m long street light bracket made of 40 mm bore GI light grade tubing including necessary clamps, nuts, bolts, washers etc, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 200x150 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 250x200 mm and 50 mm deep, complete all as specified and directed.
SINGH ENTERPRISES
L P Singh and Co.
SHREEKRISHNA INFRASTRUCTURE
ANNAPURNA ENTERPRISES
Ganesh Contruction
S.S Enterprises
M/s Prem Associates
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .