| 4 | Rejected-Technical 22 830 KALLAI POST KOZHIKODE 673005 | KOZHIKODE | KOZHIKODE | KERALA | 673005 | - | - | Rejected-Technical L7 |
| 5 | Rejected-Technical MANNILTHODI EDAKKARATHODI VEEDU AREEKODE KEEZHURAMBA P O MALAPPURAM KERALA 673639 | AREEKODE | MALAPPURAM | KERALA | 673639 | - | - | Rejected-Technical L5 |
| Sl No | Description | Qty | Unit | OMRAN PROJECTS PRIVATE LIMITED L6 | MOHAMMED ASHIF L5 | TECTONICS ENGINEERING PROJECTS L4 | RIJESH P L1 | IJAS C L3 | RAJAN P L2 | MALABAR UNION LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Maintenance work | ||||||||||
| 1.00 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | 158.4 | cum | 3,038.8 ₹4,81,345.92 | 3,048.92 ₹4,82,948.93 | 2,400 ₹3,80,160 | 750 ₹1,18,800 Lowest | 3,035.76 ₹4,80,864.38 | 2,800 ₹4,43,520 | 3,400 ₹5,38,560 |
| 1.00 | 26.30.1:Drilling suitable holes in reinforced or plain cement concrete with power driven
drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels,
columns and slabs to introduce steel bars for sunshades/balconies including
fixing the steel bars in position using epoxy resin anchor grout of approved
make but excluding the cost of reinforcement, all complete as per direction of
Engineer-In-Charge.Upto and including 12mm dia. | 35 | holes | 126.56 ₹4,429.6 | 126.98 ₹4,444.3 | 127 ₹4,445 | 1,500 ₹52,500 | 126.43 ₹4,425.05 | 100 ₹3,500 Lowest | 175 ₹6,125 |
| 1.00 | 26.35.1:Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/masonry by suitable
gun/pump at required pressure including cutting of nipples after curing etc.
complete as per directions of Engineer-in-Charge.
(The payment shall be made on the basis of actual weight of approved grout
injected.)Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/ RCC work | 35 | kg | 106.72 ₹3,735.2 | 107.07 ₹3,747.45 | 107 ₹3,745 | 105.02 ₹3,675.7 Lowest | 106.61 ₹3,731.35 | 110 ₹3,850 | 150 ₹5,250 |
| 1.00 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover | 93.6 | sqm | 2,976.73 ₹2,78,621.93 | 2,986.64 ₹2,79,549.5 | 2,974 ₹2,78,366.4 | 5,000 ₹4,68,000 | 2,973.76 ₹2,78,343.94 Lowest | 3,000 ₹2,80,800 | 3,400 ₹3,18,240 |
| 1.00 | 10.3:Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer . | 73.5 | sqm | 9,752.59 ₹7,16,815.37 | 9,785.06 ₹7,19,201.91 | 9,742 ₹7,16,037 | 5,500 ₹4,04,250 Lowest | 9,742.84 ₹7,16,098.74 | 10,500 ₹7,71,750 | 11,000 ₹8,08,500 |
| 1.01 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 13,752 | sqm | 16.95 ₹2,33,096.4 | 17 ₹2,33,784 | 17 ₹2,33,784 | 15 ₹2,06,280 | 16.93 ₹2,32,821.36 | 10 ₹1,37,520 Lowest | 22 ₹3,02,544 |
| 1.01 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 660 | sqm | 128.45 ₹84,777 | 128.97 ₹85,120.2 | 124 ₹81,840 Lowest | 150 ₹99,000 | 128.42 ₹84,757.2 | 150 ₹99,000 | 150 ₹99,000 |
| 1.01 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 13,752 | sqm | 66.91 ₹9,20,146.32 | 67.13 ₹9,23,171.76 | 64 ₹8,80,128 | 40 ₹5,50,080 Lowest | 60 ₹8,25,120 | 50 ₹6,87,600 | 80 ₹11,00,160 |
| 1.01 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 13,752 | sqm | 143.07 ₹19,67,498.64 | 143.55 ₹19,74,099.6 | 138 ₹18,97,776 | 130 ₹17,87,760 | 120 ₹16,50,240 Lowest | 120 ₹16,50,240 Lowest | 170 ₹23,37,840 |
Tender Value
₹84.7 L
EMD Value
₹50,000
Closing Date
12 Jun 2026, 6:00 pmClosed
SUPERINTENDING ENGINEER
O/o SE, Kozhikode Corporation, [email protected]
Please refer Tender document
2026_LSGD_854550_1
PP/EG7/2026-27/SE/11/12
Open Tender
Civil Works - Roads
Item Rate
365 days
Kozhikode Corporation
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
Yes
₹50,000
Yes
30 Jul 2026
6 Jun 2026
15 Jun 2026
6 Jun 2026
12 Jun 2026
6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Maintenance work | |||||
| 1.001 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | - | cum | - | - |
| 1.002 | 26.30.1:Drilling suitable holes in reinforced or plain cement concrete with power driven
drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels,
columns and slabs to introduce steel bars for sunshades/balconies including
fixing the steel bars in position using epoxy resin anchor grout of approved
make but excluding the cost of reinforcement, all complete as per direction of
Engineer-In-Charge.Upto and including 12mm dia. | - | holes | - | - |
| 1.003 | 26.35.1:Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/masonry by suitable
gun/pump at required pressure including cutting of nipples after curing etc.
complete as per directions of Engineer-in-Charge.
(The payment shall be made on the basis of actual weight of approved grout
injected.)Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/ RCC work | - | kg | - | - |
| 1.004 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover | 1 | sqm | - | - |
| 1.005 | 10.3:Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer . | - | sqm | - | - |
| 1.006 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | - | sqm | - | - |
| 1.007 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | - | sqm | - | - |
| 1.008 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | - | sqm | - | - |
| 1.009 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | - | sqm | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
ePay.pdf
Tender Documents • 0.01 MB
PRELIMINARYAGREEMENTCOMMON.pdf
Tender Documents • 0.14 MB
FOT.pdf
Tender Documents • 0.01 MB
Affidavit.pdf
Tender Documents • 0.31 MB
viewsbd12.pdf
Tender Documents • 1.64 MB
BOQ_1444276.xls
BOQ • 0.32 MB
FIP.pdf
Tender Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .