Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹31.0 L+₹21,860 (0.71%)Rejected-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-AOC ok | |
| 3 | L3₹32.5 L+₹1.7 L (5.66%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹33.1 L+₹2.4 L (7.75%)Rejected-AOC C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L4 | Rejected-AOC ok | |
| 5 | L5₹34.2 L+₹3.4 L (11.2%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
10 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
OUTSOURCING SERVICES OF EXTERNAL ELECT SUPPLY AT 33 KV MRS UNDER GE WEST BARILLY
2020_MES_360547_1
8845/E8
Open Tender
Civil Works
Item Rate
335 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRM
SCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹89,800
Yes
24 Aug 2020
13 Jul 2020
14 Aug 2020
13 Jul 2020
10 Aug 2020
28 Jul 2020
13 Jul 2020 - 27 Jul 2020
60 days
Amount
Outsoursing for 33 KV main HT receiving station by one skilled electrician and one helper.Round the clock 24 hours. In three shifts-6.00 to 14.00, 14.00 to 22.00 and 22.00 to 06.00. Including sunday and holiday including normal maintinance/overhauling i.e oiling,greasing,tightening of conductors,replacement of P.G clamps,tightening of cable joints of Power transformers/OCB panels/VCB Panels of all equipment/plant installled at main receiving centre.The installation comprising the following plant and equipment:
(i) Trans former 33/11 KV 5 MVA Capacity = 03 Nos
(ii) Trans former 33/11 KV3.15 MVA Capacity = 01 Nos
(iii) Current transformer rating = 06 Nos
(iv) Potential transformer rating - 06 Nos
(v) 11 KV OCB 400 Amp = 11 Nos
(vi) 11 KV VCB 400 Amp = 8 Nos
(vii) Transformer 11/.415 KV = 01 Nos
(viii) LT Panel = 01 Nos
(ix) 33 KV VCB & Relay panel = 06 Nos
(x) 33 KV isolators = 06 Nos
(xi) Bus bar gantry structure = 01 Nos
Payment to employed persons strictly to be done directly to AADHAR linked bank account only. The contractor shall submit all documents as per pervailing labour laws as applicable.
Electrician should be holding ''ITI certificate,experience and to be submitted by the contractor duly vertified and attested'' where dispute exists about the operators qualification/ performance will be assessed by Engineer-in-incharge. Decision shall be binding on contractor.Electrician/Helper shall posses, police verification certificate.
Contractor should maintain of proper electrical shut down register and issue PTW( permit to work). If any fault occur in sub station should be intimated to concerned JE E/M or AGE E/M immidiatly.
Electrician/Helper should not be more than 45 years of age and should not be deriving pension from any Govt/semi Govt or public sector undertaking.Any disputes will be at discretion of GE and decision shall be binding on contractor.
Necessary security passes shall be arranged by the supervisor in respect of all personel deployed as per prevaling station rule and regulation.
Contractor shall be responsible for safety, security,cleaning and upkeep of installation as per MES standards for installation.
Duty roster for one month will be prepared in advance and displayed at prominent places in installations to include names, shifts and contact Number etc. No Electrician/Helper shall be employed in continuous shift and duty roster to include rest/off day for each Electrician.
Contractor shall ensure through Electrician for day to day upkeep and check of all substation equipments as per manufacturers instructions and carry out minor repairs i.e tightening of joints,oiling/greasing of equipments,cleaning of equipments all specified and directed.
Log sheet shall be provided by the contractor at installation and shall be maintained and handing/taking between continious Electrician and Helper/Mate shall be done correctly as per norm of MES.
Emergencies shall be notified to Engr in Charge/JE/MCM. Routine operation should be under supervison of JE/MCM designated by Engr in Charge.
The work also includes cleaning of complete S/Stn/ Yard including maintenance of area within the MRS/ Sub stn .
Any minor/petty repairs arised in the subject installation shall be rectified by the employed tradesman of the contractor and minimum required toolkit/bag & consumables/minor items shall be provided by the contractor and rates are included in the above quoted rates.
The contractor shall provide First aid box /kit and all safety equipments like discharge rod, safety belt, Hand gloves, Helmet, glasses, rain Coat, Gum bootetc in the installations & rates are included in the above quoted rates.
Electrician / helper engaged on duty should be in proper dress as approved by Garrison Engineer and not be more than the age of 45 years and in a sound health and be capable to do the electric related job.
Outsourcing for day to day maintenance of external electric system i.e feeding areas of various sub stations by attending external electric complaints by maintaining all incoming and outgoing HT/LT Feeders, HT/LT OH lines and rectification of any fault occured in the feeder like disconnection of jumpers, breaking of ACSR conductor, disconnection of cable lugs from the panel/transformer, blown out of fuse element, trimming of tree branches, tripping of feeders, and loose connection in the service wires/cables, short circuiting of conductors,fixing of HT joints any type and attending of complaints for No Lights from poles and other type of faults in HT/LT will be attended immediately by Two skilled electrician and one helper.Round the clock 24 hours. In three shifts-6.00 to 14.00, 14.00 to 22.00 and 22.00 to 06.00. Including sunday and holiday. The installtion comprises the following lines/equipements in bareilly cantt area under GE (W) bareilly.
(i)Transformers 11/.415 KV
(ii)11 KV VCBs/OCBs
(iii) HT/LT OH/UG Lines
(iv) LT Panels
Notes:- (a) Cost of minor parts such as nuts,bolts, pvc connector,ruber gasket etc is deemed to be included in the quated rates. (b) Material required shall be measured & paid separately as given here-in-after. (c) Contractor shall provide all tools and plants and minor spares such as Ladder minor nuts bolts etc including maintain complaint register & job card slips duly printed as per sample required for doing the job related with electric supply including providing 3 Nos mobile phones are in each shift for communication to receive complaints and will be fully responsible for safety and security of their tradesman with out any extra cost to the department. (d) Transport will be provided by the Deptt. for attending the complaints but in case of non availability of Transport due to any reason contractor has to make his own arrangement to attend the complaints. (e) If the complaint of Ext.Elect is not attended within 01 hrs a recovery @ 100 per complaint will be lieved / recovered from the contractor.
Supply only jumper wire cross sectional area 95 Sqmm single core stranded aluminium conductor PVC insulated on OH lines complete all as specified and directed.
Supply only jumper wire cross sectional area 120 Sqmm single core stranded Aluminium conductor PVC insulated on OH lines complete all as specified and directed.
Supply only insulator pin type porcelain vitreous white, brown or green including one galvanized MS spindle, two GI washers & one GI nut of 100 mm height and 65 mm dia suitable for 1100 Volts grade complete all as specified and directed.
Suply only insulator shakle type porcelain vitreous white, brown or green including galvanised mild steel washers, insulator bolts, washers and nuts of size 75 mm height and 90 mm dia suitable for 1100 Volts grade working pressure complete all as specified and directed.
Supply only insulator pin type porcelain vitreous white brown or green including one galvanized MS spindle, two GI washers & one GI nut of 150 mm height and 150 mm dia suitable for 11000 Volts grade complete all as specified and directed.
Supply only disc type insulator porcelain, vitreous, white, brown or green including galvanised steel strip 31x3mm washer of size 145 mm high, 225 mm dia ball and socket type for working pressure 11000 Volts grade single disc assembly.
Supply only cable end box ( heat shrinkable) indoor type HT 11000 volts grade suitable for XLPE 11000 volts grade screened armoured cable of size (50 Sqmm to 95 Sqmm) 3 core heat shrinkable connected with electric system with complete all as specified and directed.
Supply only cable end box ( heat shrinkable) outdoor type HT 11000 volts grade suitable for XLPE 11000 volts grade screened armoured cable of size (50 Sqmm to 95 Sqmm) 3 core heat shrinkable connected with electric system with complete all as specified and directed.
Supply only cable end box (Heat shrinkable) out door type HT 11000 volts grade suitable for XLPE 11000 volts grade screened armoured cable of size (120 Sqmm to 185 Sqmm) 3 core heat shrinkable connected with electric system with complete all as specified and directed.
Supply only cable end box (Heat shrinkable) straight through type HT 11000 volts grade suitable for XLPE 11000 volts grade screened armoured cable of size (50 Sqmm to 95 Sqmm) 3 core heat shrinkable connected with electric system with complete all as specified and directed.
Supply only cable end box (Heat shrinkable) straight through type HT 11000 volts grade suitable for XLPE 11000 volts grade screened armoured cable of size (120 Sqmm to 185 Sqmm) 3 core heat shrinkable connected with electric system with complete all as specified and directed.
Supply only HT Tape roll ISI Marked.
Supply only of fuse wire 5 Amps to 100 Amps
Supply only Aluminium Lugs/connectors of size 16 sqmm
Supply only Aluminium Lugs/connectors of size 25 sqmm
Supply only Aluminium Lugs/connectors of size 35 sqmm
Supply only Aluminium Lugs/connectors of size 50 sqmm
Supply only Aluminium Lugs/connectors of size 70 sqmm
Supply only Aluminium Lugs/connectors of size 95 sqmm
Supply only Aluminium Lugs/connectors of size 120 sqmm
Supply only Aluminium Lugs/connectors of size 150 sqmm
Supply only PG.Clamp suitable for Dog conductor
Outsourcing for attending of internal electric supply complaint of day to day internal electric maintenance of MH Bly by providing one electrician & one helper in one shift from 16.00 hrs to 24.00 hrs and have to carry out repairs & maintenance of existing electric point wiring electric internal fitting/fixtures,sub main wiring,DBs,MCBs,MCCBs, short circuit, earth leakage, no light and repair to all other electrical system at MH and to make the electric supply functional including sunday and holiday under jurisdiction of of Military Hospital Bareilly including noting the complaint from unit in MES complaint cell register in & distribution of tradesmen through complaint slip etc complete all as specified and directed.
Notes:- (a) Cost of minor parts such as nuts,bolts, pvc connector,ruber gasket etc is deemed to be included in the quated rates. (b) Material required shall be measured & paid separately as given here-in-after. (c) Contractor shall provide all tools and plants and minor spares such as Ladder minor nuts bolts etc including maintain complaint register & job card slips duly printed as per sample required for doing the job related with electric supply including providing 3 Nos mobile phones are in each shift for communication to receive complaints and will be fully responsible for safety and security of their tradesman with out any extra cost to the department. (d) Transport will be provided by the Deptt. for attending the complaints but in case of non availability of Transport due to any reason contractor has to make his own arrangement to attend the complaints. (e) If the complaint of Ext.Elect is not attended within 01 hrs a recovery @ 100 per complaint will be lieved / recovered from the contractor.
R. S. Associates
M/S HINA ELECTRICALS
D K THUKRAL AND SONS
M/S MAISUR CONSTRUCTION COMPANY PRIVATE LIMITED
shahji contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .