Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹44.0 LAccepted-AOC | ₹44.0 L | I | Accepted-AOC Lowest Bidder |
| 2 | II₹46.7 LRejected-AOC | ₹46.7 L | II | Rejected-AOC Second Lowest Bidder |
| 3 | III₹49.6 LRejected-AOC | ₹49.6 L | III | Rejected-AOC Third Lowest Bidder |
| 4 | IV₹52.5 LRejected-AOC | ₹52.5 L | IV | Rejected-AOC Fourth Lowest Bidder |
Tender Value
₹49.6 L
EMD Value
₹50,000
Closing Date
18 Dec 2021, 5:00 pmClosed
DEPUTY CHIEF ENGINEER
ELECTRICAL CIRCLE KSEB LIMITED THODUPUZHA
Shifting of 13.7km 33kV line, 720mtr 11kV line and 5.48km 3phase/1phase line with all materials excluding the supply of poles and conductors under Electrical section, PEERMADE
2021_KSEB_458873_1
ECT-32/21-22 dated 04.12.2021
Open Tender
Electrical Works
Item Rate
60 days
KUTTIKKANAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,900
₹50,000
1 Jan 2022
8 Dec 2021
20 Dec 2021
8 Dec 2021
18 Dec 2021
8 Dec 2021
8 Dec 2021 - 18 Dec 2021
Amount
PART-A MATERIALS
CABLE 1.1kV PVC Al 2x2.5 sq mm Sheathed (Weather Proof 1/1.8)
CABLE 1.1kV PVC Al 2x6 sq mm Sheathed (Weather Proof 1/2.8)
G.I.WIRE. 4mm (8 SWG)
BOLT & NUT GI OF SIZES
CRIMPING SOCKET 95 sq mm (Aluminium)
PACKING CLAMP
PIN INSULATOR 415V SET(WITH PIN)
SHACKLE INSULATOR 415V SET(WITH STRAP BOLT&NUT)
STAY INSULATOR 415 V
STAY ROD 16 mm DIA GI ( LT Stay Rod)
STRANDED WIRE GI 7/2.5 mm (LT Stay Wire)
STAY TIGHTNER LT
CLAMP GI FOR LT CROSS ARM
CROSS ARM GI 2 LINE
CROSS ARM GI CHANNEL 100X50 mm 2.4 M
CROSS ARM GI 4 LINE
AB SWITCH 11 kV 400A
CLAMP GI FOR V CROSS ARM
LIGHTNING ARRESTOR 9 kV 5 KA
STAY INSULATOR 11 kV
STRANDED WIRE GI 7/3.2 mm (HT Stay Wire)
BOLT & NUT BRASS OF SIZES
CLAMP GI FOR HT CROSS ARM
EARTH PIPE GI 40 mm DIA
CROSS ARM GI CHANNEL 75X40mm 2.4m
FUSE UNIT 415 V PORCELAIN 200 A
CLEAT GI FOR DISC INSULATOR
CROSS ARM GI CHANNEL 100X50 mm 3 M
CROSS ARM GI CHANNEL 75X40 mm 1.8 M
FUSE DROP OUT 11 kV
SINGLE TENSION CLAMP GI 11KV (HARDWARE FITTINGS 11kV)
STAY ROD 20 mm DIA GI ( HT Stay Rod)
STAY TIGHTNER HT
CABLE 1.1kV XLPE AL 1X120 sq mm (Un Armoured)
CRIMPING SOCKET 120 sq mm (Aluminium)
V CROSS ARM 11 kV-GI
CLAMP GI FOR STAY / STRUT (LT)
COMPOSITE PIN INSULATOR 11 kV with Pin
COMPOSITE DISC 11kV
Earthing coil
ANCHOR PLATE FOR LT STAY
ANCHOR PLATE FOR HT STAY
CLAMP GI FOR STAY / STRUT (HT)
Thimble (HT)
Helical Fitting for LT Stay wire (Guy Grip)
Thimble (LT)
Helical Fitting for HT Stay wire (Guy Grip)
EARTH CLAMP
PIN INSULATOR 33kV SET(WITH PIN)
PG CLAMP ACSR DOG- DOG
V CROSS ARM 33 kV-GI
SINGLE TENSION CLAMP GI 33KV (HARDWARE FITTINGS 33kV)
Earth Connector120sq.mm
STAY INSULATOR 33kV
PART-B LABOUR
Dismantling without damage Latlce pole C Type pole as per specification of KSEB
Dismantling without damage one 33kv A " Type pole after disconnectlng stay, strut etc and stacking the same
Dismantling with damage one 33kv A " Type pole after disconnectlng stay, strut etc and stacking the same
Dismantling (without damage) one 33kv DP after disconnectlng stay strut etc ,and stacking the same
Dlsmantłing (with/ wlthout damage ) one 33KV stay includlrig back filing and brlng back to sectłon
Dlsmantling ( włthout damage ) one 33KV Fly stay lncludłng back fllłing and brlng back to sectlon
Dismantling (without damage ) one Km 33 KV line ( 3 Conductors ) cross arm ,insulators, ,disc rolling the conductor and stacking
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Loading and Unloading of ACSR Dog conductor, Earthwire, insulators, angles,structures and all accessories issued departmentaly for the line works from Departmental stores and distribution to locations or nearest storage place for erection including storage etc complete.
Carriage of Materials by manual labours, such as Steel Angles, Channel cross arms,ACSR Dog conductor, Earthwire, insulators, and all accessories issued departmentaly for the line works from nearest stored site and distribution to locations average 1 Km( 0.05 to 2 Km) for erection including storage if necessary, loading and unloading charges etc complete.
Loading HT 'A' type pole from the stacking place and unloading the same at work site (transport by vehicle).
Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
Stub setting of Lattice tower in correct alignment using template in concrete foundation including, anchoring etc, if necessary and removing the template after the expiry of the predetermined time but excluding excavation, concreting, back filling etc complete.
Errection of Lattice tower superstructure above ground level (excluding the stub portion) as per the directions of department staff at site.
Fitting and erecting A type single pole in 33 KV lines and levels keeping upright until curing and hardening of footing concrete including fitting cross arms and coil earthing etc complete
Fitting and erecting 1 No. single cut pole using A type pole in 33 KV lines and levels keeping upright until curing and hardening of footing concrete including fitting cross arms and coil earthing etc complete. Excluding the cost of form work.
Fitting and erecting 1 No. DP in A type pole for 33 KV lines and levels keeping upright until curing and hardening of footing concrete including fitting cross arms and coil earthing etc complete.
Fitting and providing 1 No stay for 33 KV pole including digging & back filling pit in ordinary soil
Fitting and providing 1 No fly stay for A type pole for 33 KV line including back filling pit inc;uding digging & and back filling pit in ordinary soil
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole incl. digging & back filling pits.
Fitting and providing one strut for 33 KV Pole using ’ A Pole including digging and back filing pit in ordinary soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3.0m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m-All kinds of soil
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3.0 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.-Ordinary rock
Cement concrete 1:3:6 mixture with 40mmbrocken stone for foundation bed
Providing and laying in position Cement Concrete 1:2:4 using Cement - 320 Kg/m3, 20mm graded stone ( 20 mm-0.67 m3 and 10 mm-0.22 m3) and M sand(coarse -.445m3) for foundation of poles, stay block etc ,including watering, curing etc. complete
Plastering with cement mortar 1:4, 12mm Thickone coat over the concrete surface
Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1)
Paving out, stringing and tensioning as per standard of 3 line ACSR Dog conductor including attaching insulator string or pin insulator on pole cross arms, clamping conductor on the pin insulator as well as on insulator string, jempering the conductor at tension points, jointing of conductor wherever necessary, hire charges for all the tools and trackles, providing suitable back stays at the time of stringing if necessary etc complete.
Drilling hole of various sizes on existing Channel/Cross Arm.
Cutting Channel/Cross Arm/Angle Iron into two pieces.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling.
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Back filling of pits with the original excavated soil etc. complete CPWD-2.25
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.-Hard rock (blasting prohibited) CPWD 2.26.2
Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials.
Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
Dismantling (without damage) one km LT additional conductor line by dismantling cross arms, insulators and stacking the conductors in rolls properly.
Dismantling (without damage) one km LT single phase 2 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
Dismantling (without damage) one 11kV 'A' type pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same
Dismantling one damaged 11kV TW/RSJ/Rail pole after disconnecting stays, strut etc. and stacking the same.
Dismantling transformer station with transformer erected in DP structure by dismantling HT Double Pole Structure using PSC pole after disconnecting stay wires, 10 channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipments, CTs, Distribution Box, statutory display boards etc. but excluding the rate of dismantling transformer, earthing, stay sets & fencing
Dismantling one damaged 11kV 'A' type pole after disconnecting stays, strut etc. and stacking the same.
Dismantling one damaged LT TW/RSJ/Rail pole after disconnecting stays, strut etc. and stacking the same.
Loading LT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Fitting and erecting one HT 'A' type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing)
Fitting and erecting one HT Double Pole Structure using 'A' type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing)
Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
Stringing of one km 11kV line with ACSR Raccoon (3 conductors) after fitting insulators and giving jumper connections including cutting and removing tree branches wherever necessary excluding cut point works.
Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point.
Fitting one Additional 2.4m Channel cross arm in existing single pole incl. conveyance of materials.
Fitting 6 channel cross arms, AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set (3No.) of LT fuses, drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles.
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
Erecting one 100kVA Transformer to existing Plinth/Platform and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer.
Fitting one additional Fuse unit and giving connection from Transformer to fuse and DB to LT OH line.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at standard distance (1.5m) away from the pole/structure in ordinary soil & backfilling the pit with 15cm alternate layer of charcoal, salt and sand up to 90cm from the bottom. including the cost of 20kg salt, 25kg charcoal, excluding supply of earth pipe.
Fitting one Additional V cross arm in existing single pole incl. conveyance of materials.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials.
Additional rate for excavation of Pit for 'A' type pole in Laterite.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Erecting one LT PSC Pole in position incl. digging & back filling pit.
Providing Stay for LT poles incl. digging & back filling pit.
Providing Strut using LT PSC pole incl. digging & back filling pit.
Providing Fly stay for LT pole using LT PSC pole incl. digging & back filling pit.
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and ACSR Weasel for Neutral & Street Main, for one km LT 3ph 5 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and ACSR Weasel for Neutral, for one km LT three phase 4 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase & Neutral and ACSR Weasel for street main, for one km LT single phase 3 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and Neutral, for one km LT single phase 2 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place
Fitting one LT 2 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
Disconnecting and lowering down the three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work
Additional rate for excavation of one Pit for LT Pole/LT Stay in Laterite.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Hard Laterite.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Soft Rock.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Rock.
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Dismantling and re erecting existing transformer fencing of all sizes
Dismantling existing transformer fencing of all sizes
Varghese Elappanikal Mathew
JJ ASSOCIATES
Saju M J
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_657103.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .