Installation of three phase supply and power sockets for equipment at ceramic composite lab
2024_NITC_816922_1
Engg/EMU/JE2/22/CerCom/2024-25
Open Tender
Electrical Works
Item Rate
30 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹7,400
Yes
13 Aug 2024
17 Jul 2024
9 Aug 2024
17 Jul 2024
7 Aug 2024
17 Jul 2024
Amount
WIRING IN STEEL & PVC CONDUIT
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
6 x 6 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
MCCB, MCB & DB'S
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, necessory industrial work making connections, etc. as required Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required including suitable enclosure or industrial work.
16-100 A, 25kA, 4 pole MCCB, 415 V
125 A, 25kA, 4 pole MCCB, 415 V
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Four pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP/FP/TP sheet steel enclosure on surface/ recess without MCB complete with connections, testing and commissioning etc. as required.
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 50 sq. mm (28mm)
Supplying and making end termination with copper reducer/bottle lugs/terminal lugs for following size of PVC insulated copper stranded cable of 1.1 KV grade as required.
ELECTRICAL FIXTURES
Supply and fixing of following Exhaust Fan with necessory arrangement
Supplying and fixing of heavy duty 300mm sweep exhaust fan speed>1400rpm including connection etc. as required. Make:havells/almonard or Equivalent
LABOUR
Removing of following items and handing over to EMU safely.
Removing three phase switch fuce unit including mounted structure and incoming cable handing over to EMU store safely as required.
Removing three phase switch fuce unit from panel including rotary handle and handing over to EMU store safely as required.
PANELS AND ACCESSORIES
PANEL ACCESSORIES
LED Indicators
Supply and fixing of 24V AC/DC or 240V AC Red/Green/Yellow/Amber coloured ( power consumption <1W) LED indicators with surge and low voltage glow protection (L&T, Snider or equvalent) .Including necessory arrangements for fixing on exixsting panel etc. as required.
Supply and fixing of 24V AC/DC or 110/240V AC White/Blue coloured ( power consumption <1W) LED indicators with surge and low voltage glow protection (L&T, Snider or equvalent) .Including necessory arrangements for fixing on exixsting panel etc. as required.
Supply and fixing of MCCB and its accessories including necessory arrangement for fixing on exixting panel etc. as required.
Rotary Handle Extended ROM including drilling slots in cubical panel
Labelling of Panel/DB/SB etc.
Labelling of DB/Switch board with adhesive plastic coated printed labels/Paint (3 to 6 letters, maximum 25sq.cm. size) necessory arrangement for fixing/painting on exixting DB/switch board etc. as required.
Drawing and Approval
Submission of as fitted drawings and SLD of the work in Autocad DWG and PDF format along with physical copy of the same in the format and standard to get the approval from electrical inspectorate.(along with seal,signature and license details) etc as required.
MAHESH KR
DIAMOND ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .