| 1.00 | Dismantling broken concrete/steel poles, any size complete all as specified and directed by Engr-in-Charge | 10 | Each | 250 ₹2,500 | 150 ₹1,500 Lowest | 500 ₹5,000 |
| 2.00 | Taking down of existing light of any type above and fixing on new poles complete all as specified and directed by Engr-in-Charge | 19 | Each | 25 ₹475 Lowest | 50 ₹950 | 75 ₹1,425 |
| 3.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge | 35 | Cum | 150 ₹5,250 Lowest | 350 ₹12,250 | 240 ₹8,400 |
| 4.00 | Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed | 23 | Cum | 120 ₹2,760 | 300 ₹6,900 | 70 ₹1,610 Lowest |
| 5.00 | Removing excavated material (i.e soil) from site to a distance n.exc 50 mtrs away and depositing where directed at a level n.exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge | 12 | Cum | 110 ₹1,320 Lowest | 300 ₹3,600 | 150 ₹1,800 |
| 6.00 | M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified | 11 | Cum | 2,200 ₹24,200 | 1,000 ₹11,000 | 786 ₹8,646 Lowest |
| 7.00 | S&F in replacement sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer-in-Charge | 1,130 | Each | 12 ₹13,560 | 9 ₹10,170 Lowest | 15 ₹16,950 |
| 8.00 | Supplying, laying, jointing testing and connecting in replacement of size 16 Sqmm 4 core, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multi-stranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed.
Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule | 50 | RM | 180 ₹9,000 | 150 ₹7,500 Lowest | 188 ₹9,400 |
| 9.00 | All as per Srl Item No. 8.00 here-in-before but size 25 Sqmm 4 core | 60 | RM | 240 ₹14,400 | 200 ₹12,000 Lowest | 238 ₹14,280 |
| 10.00 | All as per Srl Item No. 8.00 here-in-before but size 16 Sqmm 2 core | 210 | RM | 160 ₹33,600 | 150 ₹31,500 Lowest | 158 ₹33,180 |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
7 Jul 2025, 6:00 pmClosed
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR/ MAINTENANCE TO STREET LIGHT AND FLOOD LIGHTS AND CONNECTED WORKS AT TRANSIT CAMP, PALCHAN UNDER AGE (I) R and D MANALI
2025_MES_713319_1
AGE(I)/MNL-28/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Transit Camp Palchan
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE(I) R and D MANALI
₹12,000
Yes
22 Aug 2025
9 Jun 2025
15 Jul 2025
9 Jun 2025
7 Jul 2025
23 Jun 2025
Amount
Dismantling broken concrete/steel poles, any size complete all as specified and directed by Engr-in-Charge
Taking down of existing light of any type above and fixing on new poles complete all as specified and directed by Engr-in-Charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed
Removing excavated material (i.e soil) from site to a distance n.exc 50 mtrs away and depositing where directed at a level n.exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified
S&F in replacement sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer-in-Charge
Supplying, laying, jointing testing and connecting in replacement of size 16 Sqmm 4 core, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multi-stranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed. Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule
All as per Srl Item No. 8.00 here-in-before but size 25 Sqmm 4 core
All as per Srl Item No. 8.00 here-in-before but size 16 Sqmm 2 core
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or rerouting after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Excavation and earth work will be measured and paid for separately under respective items of schedule
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit of 25-50 Sqmm x 3.5 core/ 4 core suitable for cable PVC/XLPE insulated armoured heavy duty aluminum conductor 1100 Volts grade complete all as specified and directed
Supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and directed by E-in-charge. Note :- (a) The unit rate in this item is deemed to be included the cost of ,PCC foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1 as in steel tubular pole . The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminum paint over a coat of red oxide complete all as specified and directed. (b) Excavation, earth work and GI bracket will measured and paid separately under relevant item
S&F in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint complete all as specified and directed
S&F in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm outside and 300x200x105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red color on front face of KIOSK box body complete all as specified and directed incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer complete all as specified and directed
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed Make : Crompton or equivalent in Havells,/Bajaj
S&F in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make : Crompton or equivalent in Havells,/Bajaj.
S&F in replacement of LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make : Crompton or equivalent in Havells,/Bajaj
M&L for electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to Aluminum strip of size 25 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of soil , PCC 1:2:4 type C-1 in chamber , RCC 1:2:4 type C1 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoal dust, salt , funnel for watering complete and testing the Earth resistance and writing on the chamber by paint all as specified and as directed.
SP Builders (BID ID -3341269)
M/S SUKHMANI ENGINEERS (BID ID -3349874)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .