Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.7 CrAccepted-AOC | ₹2.7 Cr Quoted ₹2.3 Cr | L-1 | Accepted-AOC Bidder is L-1 |
| 2 | L-2₹2.9 Cr+₹57.5 L (25.1%)Rejected-Finance ALIGARH | ALIGARH | UTTAR PRADESH | 202001 | ₹2.9 Cr+₹57.5 L (25.1%) | L-2 | Rejected-Finance Bidder is not L-1 but matched L-1 rates for empanelment |
| 3 | L-3₹3.3 Cr+₹1.0 Cr (45.6%)Rejected-Finance | ₹3.3 Cr+₹1.0 Cr (45.6%) | L-3 | Rejected-Finance Bidder is not L-1 but matched L-1 rates for empanelment |
| 4 | L-4₹3.9 Cr+₹1.6 Cr (69.5%)Rejected-Finance B 14 SECTOR 67 GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹3.9 Cr+₹1.6 Cr (69.5%) | L-4 | Rejected-Finance Bidder is not L-1 |
| 5 | L-5₹3.9 Cr+₹1.6 Cr (71.0%)Rejected-Finance | ₹3.9 Cr+₹1.6 Cr (71.0%) | L-5 | Rejected-Finance Bidder is not L-1 |
Tender Value
Refer Docs
Closing Date
10 Dec 2020, 6:30 pmClosed
Manager (Techno-Commercial)
IndianOil-Adani Gas Pvt. Ltd, 306-309, 3rd Floor, Salcon Aurum Building, Plot No. 04, Jasola Distt Centre, New Delhi-110025
ANNUAL RATE CONTRACT FOR MDPE PIPE NETWORK LAYING, LMC AND ASSOCIATED WORKS AT IOAGPL GAYA NALANDA
2020_AGPL_63393_1
IOAGPL/PE/LYG/2020-21/55
Open Tender
Supply, Erection and Commissioning
Tender cum Auction
365 days
Gaya-Nalanda
As per Technical Volume
3 documents required · 3 mandatory
₹0
Exempted
Gaya
6 Feb 2021
2 Dec 2020
12 Dec 2020
2 Dec 2020
10 Dec 2020
2 Dec 2020
2 Dec 2020 - 5 Dec 2020
4 Dec 2020
Amount
PART-A (MDPE SECTION)
MDPE pipeline laying
Survey of designated area and survey drawings of societies / colonies/ localities shall be provided by the contractor. However the MDPE pipe is to be laid on best probable route after discussion with EIC. Receiving, handling, loading, transportation and unloading of owner supplied MDPE Pipes, PE Fittings, TF, PE valve & Warning Mat & any other free issue items as mentioned elsewhere in tender from designated stock yards to contractor's own stock-yards/ work-sites. Supply of HDPE casing and any item items other then FIM shall be provided by contrcator. Proper storing, stacking, identification, providing security and insurance cover for the materials. Liaisoning with landowning agencies/ statutory authorities, preparation of detailed route plan, making trial pits to determine the underground utilities/ services etc., obtaining permission from landowning agencies (separately payable as per other SOR Item). Restoration of the abandoned excavation/ trial pits as per satisfaction of Engineer-in-charge (EIC)/ Site-in-charge (SIC) to original condition, barricading the work area as per the procedures & drawings provided in the tender and as per the directions of EIC/ SIC; uncoiling/ stringing of pipes, jointing of the pipe ends/ fittings/ valves by qualified personnel, using approved electro fusion techniques as per specification. Entire work shall be executed as per scope of work, specification, PNGRB T4S and/or any other specification as per requirement of statutory authorities.
Laying using any method (open trench, moling and HDD) in all kind of soil (normal/ hard) with all kind of surface (kachha/ pacca) with or without casing pipe; it includes survey of the under ground utilities, submission of HDD profile for approval, execution of the work as per specification, PNGRB T4S and/or any other specification as per requirement of statutory authorities, including excavation of pits, moling with hole size not exceeding 20% of the the carrier/ casing pipe dia. jointing and insertion of the carrier pipe in casing pipe (on case to case basis) and subsequent backfilling, compaction, submission of as-built drawing, as graphs as per attached specification and instructions of ElC/ SIC of owner. Includes laying of pipeline in all type of surface including kutcha, metal, concrete (PCC/RCC), bituminous, tiled, bricklined etc. after raking up of hard surface of any type. Roads, pavement, footpaths etc. shall be made motorable once the pipeline is laid. Includes minimum 300 mm (150mm below the pipeline & 150 mm above the pipeline) loos soil/sand bedding & padding in all kind of soil (normal/ hard/ rocky), & laying of warning mat above pipeline. Trench shall be filled by normal/ soft soil and no sharp rock/ boulders to be used for backfilling.Restoration of road/footpath( metal, concrete (PCC/RCC), bituminous, tiled, bricklined etc) shall be done by separate line item of SOR if required).
Flushing, cleaning, pneumatic testing, purging with nitrogen and commissioning as per scope of work, specification and approved procedures providing all tools and tackles, nitrogen, instruments, manpower and other related accessories and as per instructions of the EIC/ SIC. Maintaining the completed pipelines/ installation for any defect, failures during defect liability period.
Handing over the completed works to owner for their operation/ use, returning of all surplus material to owner stores, reconciliation of free issue material area wise and obtaining no objection certificate.
On completion of gas charging of pipelines, preparation and submission of as-built drawings, crossings details, termination, utility graphs and deviation statements. Submission of all documents required for contract closure in numbers as mentioned in contract.
In case more than 1 MDPE pipelines are laid in a common trench, SOR rate of higher dia plus 1/3rd SOR rate of lower dia will be paid.
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by open trench methodology
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by open trench methodology of laying by maintaining minimum clear cover of minimum 1.0 m from the top of lowest datum available in the vicinity of the pipeline.
20 mm Dia
32 mm Dia
63 mm Dia
90 mm Dia
125 mm Dia
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by moling methodology without HDPE casing pipe
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by moling methodology without HDPE casing pipe by maintaining minimum depth of 1.5 m from the top of lowest datum available in the vicinity of the pipeline.
20 mm Dia
32 mm Dia
63 mm Dia
90 mm Dia
125 mm Dia
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by moling methodology with HDPE casing pipe
MDPE pipeline laying in all kind of terrain in normal soil with all type of surface by moling methodology including supply & installation of PE6N HDPE casing pipe & HDPE coupler by maintaining minimum depth of 1.5 m from the top of lowest datum available in the vicinity of the pipeline.
32 mm Dia (in 50 mm HDPE casing pipe)
63 mm Dia (in 125 mm HDPE casing pipe)
90 mm Dia (in 200 mm HDPE casing pipe)
125 mm Dia (in 250 mm HDPE casing pipe)
MDPE pipeline laying by HDD method without casing pipe
MDPE pipeline laying by HDD method without casing pipe in all kind of terrian & soil condition including survey of the underground utilities, intimation to all other utility agencies through owner, submission of HDD profile for approval, execution of the work as per the scope of work, standard procedure, specifications & PNGRB T4S, including excavation of the pits, jointing and insertion of carrier pipe, subsequent backfilling, compaction, restoration, submission of as-built drawings/ graphs as per specification and the instructions of EIC/ SIC of owner.
32 mm Dia
63 mm Dia
90 mm Dia
125 mm Dia
MDPE pipeline laying by HDD method with HDPE casing pipe
MDPE pipeline laying by HDD method with casing pipe in all kind of terrian & soil condition including survey of the underground utilities, intimation to all other utility agencies through owner, submission of HDD profile for approval, execution of the work as per the scope of work, standard procedure, specifications & PNGRB T4S, including supply & installation of PE6N HDPE Casing pipe & HDPE coupler. Excavation of the pits, jointing, pulling of casing pipe & insertion of carrier pipe, subsequent backfilling, compaction, restoration, submission of as-built drawings/ graphs as per specification and the instructions of EIC/ SIC of owner.
32 mm Dia (in 50 mm HDPE casing pipe)
63 mm Dia (in 125 mm HDPE casing pipe)
90 mm Dia (in 200 mm HDPE casing pipe)
125 mm Dia (in 250 mm HDPE casing pipe)
MDPE pipeline laying by HDD method in Hard rock with or without casing pipe
MDPE pipeline laying by HDD method with or without HDPE casing pipe in all kind of terrian & hard rock strata including survey of the underground utilities, intimation to all other utility agencies through owner, submission of HDD profile for approval, execution of the work as per the scope of work, standard procedure, specifications & PNGRB T4S, including excavation of the pits, jointing and insertion of carrier pipe, subsequent backfilling, compaction, restoration, submission of as-built drawings/ graphs as per specification and the instructions of EIC/ SIC of owner. This item is applicable only when Mud Motor and rock tooling is used.
32 mm Dia
63 mm Dia
90 mm Dia
125 mm Dia
Hard rock excavation for MDPE pipeline laying in hard rock
Removal of hard rock strata/ large boulder encountered during excavation exceeding 1.0 m in any direction of the trench and removable only by chisel/ pneumatic chisel/ drill and backfillinig with soft/ normal soil after sand bedding & padding as per the scope of work, specifications and after prior intimation/ approval of EIC/ SIC. Scope of this item includes minimum 300 mm (150mm below the pipeline & 150 mm above the pipeline) sand bedding & padding in hard rock, supply & laying of warning mat above pipeline. Trench shall be filled by normal/ soft soil and no sharp rock/ boulders to be used for backfilling. In case of less cover PCC (1:3:6) of 150 mm thickness is covered under this item only. MDPE pipeline laying rates shall be payable as per SOR Item No. 1 above.
Excavation of hard rock
Restoration of trenches
Restoration to original conditions surface like bituminous/ asphalted road, concrete pavement, RCC pavements, tiles/ slabs/ blocks/ curb stones/ Agra/ Kota stones (chequered/ interlocking etc.), brick lining/ channels pavement as per the scope of work, technical specifications after laying of pipeline in built-up surface, as per the directions of EIC/SIC. Scope includes providing of the approved quality material, testing of materials by third party agencies as per scope of work, technical specification/ CPWD/ IRC standards, submission of the restoration reports, obtaining no objection certificates from the concern local authorities/ statutory authorities/ land owners/ third party inspection agencies designated by land owing agencies and owner.
Bituminous/ Asphalted
Cement concrete (PCC)
Tiles/ Slabs/ Paver Blocks/ Curb Stones etc.
Brick lining/ Channels etc.
Protection for less cover
Providing and laying in position cement concrete of specified grade of 150 mm thickness, compacting including cost of centering and shuttering. This is not applicable in SOR Item No 8 above. Minimum cover as per PNGRB T4S needs to be maintained.
PCC (1:3:6) (1 Cement:3 Coarse Sand:6 Graded stone aggregate of 20mm)
Fabrication & installation of pipeline markers
Fabrication and installation of pipeline RCC route markers/ steel pole markers/ steel plate markers as per the scope of work, specification & PNGRB T4S along the route/ boundary wall, lamp posts including all associated civil works such as excavation and construction in all types of soils, construction of pedestals and grouting with concrete, cleaning, application of approved color and quality of primer and paint, stencil letter cutting of numbers, direction, chainage etc., restoration of area to original condition and performing all works as per scope of work, specification, PNGRB T4S and instructions of EIC/ SIC.
RCC route markers
Steel pole markers with foundation
Steel plate markers
Liasoning with land agencies for permission
Submission of applications as per approved drawings provided by owner (Initial route survey, preperation of drawings, measuring and providing details of surface type shall be in scope of contractor with approval from owner), obtaining & submission of demand note, coordination, liaisoning, obtaining written permissions from land owing agencies like municipal corporation, PWD, development authority, NHAI, railways and any other government agencies who maintains the public lands. These rates are not applicable for private lands i.e. apartments/ institutions etc.
MDPE pipeline of all sizes except 20mm
PART-B (INSTALLATION WORKS)
Construction of Foundation & Installation of DRS/ MRS/ Metering Skid/ Service Regulator
Receiving and taking over, handling, loading, transportation and unloading of DRS/ Service Regulator/MRS/ Metering Skid from owner's designated stockyards to site, installation and hooking up with Steel & MDPE pipe.
Installation of DRS with RCC pedestal, foundation and Structural Works. Providing and laying reinforced cement concrete of grade M-20 with 20 mm and down grade crushed stone aggregate in all types of structures like foundations, pedestals, pedestal bases, pipe supports, sleepers, columns, equipment, foundation, etc. including providing fencing with gate wherever required.
Hook up from the existing steel tapping to DRS inlet and installation of all the items like pipe, fittings, valves, etc. supplied as FIM by owner as per the directions of the EIC/ SIC.
Supply of all materials, fabrication and erection of chain link fencing 2.5 m high with mesh upto 2 m height providing proper bracing & supprots at safe intervals and barbed wire fencing complete in all respect including painting as per technical specification on all steel items, all works as per specification including foundations and RCC beams.
Supply fabrication and erection of all types of pipe supports like clamps, saddle, guide, stops, cradles, neoprene sheet, turn buckles, anchors, T-posts, stockade/ trestle and pipe bridge for overhead piping, frames for canopy, approach ladders and platforms, crossover, cable tray supports etc, including painting suitable for highly corrosive area as per specification, labour and supervision & complete work as per drawing, specifications and instructions of EIC/ SIC.
All handling and transport charges of raw materials and fabricated structures including double handling, as required, for completion of work in accordance with time schedule, are deemed to be included in the quoted rates.
Bolts, nuts, washer, U-clamps, gaskets etc. if required during installation shall be procured and supplied by the contractor within the rate quoted.
Rate quoted in SOR shall include cost of all labour, tools, tackles, equipment, hire charged etc. This is a lump sum item rate and shall not be measured & paid separately
DRS 2000 SCMH installation, Foundation Size approx. (3000 mm x 2000 mm x 750 mm)
DRS 5000 SCMH installation, Foundation Size approx. (4500 mm x 2000 mm x 750 mm)
Service Regulator installation, Foundation Size approx. (800 mm x 500 mm x 600 mm)
MRS / Metering Skid installation, Foundation Size as per Skid
PART-C (CIVIL & STRUCTURAL WORKS)
Installation of brick/ RCC valve chambers/ pits
All civil works including excavation of pit, piping supports including best grade bricks used for all walls, PCC and RCC works required for valves pit base & top cover, internal surface plaster, primer & paint coatings on walls, cat ladders & pedestals with insert plates as required sealing of pipe at valve pits, providing metal cover with locking arrangement etc and finishing, clean up and restoration of site, filling and grading of area around the valve station to avoid any local water/ sewage flooding of that area, with provision of separate metal handle to operate valves from above ground as per the approved for construction drawings and specifications as per instruction of EIC/ SIC.
Earth work in excavation and filling to the grades and levels shown in the approved drawings in all kinds of soil including for road embankments, using approved quality good earth from designated borrow area, for all heights and depths including clearing and stripping (Min. 150 mm) of the area marked for filling, taking spot levels, consolidating the exposed natural soil surface, excavating the earth from borrow area loading, transporting & unloading, spreading in layers not exceeding 150 mm thickness, breaking clods, watering (if reqd.), ramming and compacting by manual/ mechanical means to give minimum 95% of modified Proctor's density of earth, testing & dressing including disposal of all unserviceable material all complete as per specifications and directions of EIC/ SIC. Rate to include cost of labour, tools, tackles, equipment, hire charges, cost of borrow earth by way of realities, right of way, cess etc., as applicable with all by works and sundry works.
Supplying and laying plain cement concrete (including shuttering of required) in all types of concrete works including levelling courses below foundation, substructure, superstructure, chambers, cable trench, under floors and any other locations, at all levels as per drawings, specifications and directions of EIC/ SIC.
Providing and laying reinforced cement concrete of grade M-20 with 20 mm and down grade crushed stone aggregate in all types of structures like foundations, pedestals, pedestal bases, pipe supports, sleepers cable trench including construction joints, bitumen painting on surface in contact with soil, providing and fixing reinforcing steel, shuttering, inserts, finishes etc. at all depths and heights complete as per drawings, specifications and direction of the EIC/ SIC.
Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials, such as minimum 43 grade cement including sulphate resistant cement for sub structures, R/F steel, Inserts, bolts, conduits, bitumen, other minor construction materials, shuttering tanging, earth work in excavation and backfilling using serviceable earth in all conditions shorting bailing and pumping out water, testing of concrete, curing etc. will all bye works and sundry works.
Providing and laying reinforced cement concrete (M20 Grade) with 20 mm and down grade crushed stone aggregate in pavement, including preparation of base (i.e. compacted sub grade, 200 thk sand and 50 thk PCC M-10 grade), leaving pockets if necessary, making recess, projections fixing inserts conduit pipes (GI, PVC, HDPE etc.) laying in alternate panels, filling the gaps between the panels with bitumen etc., making slopes, finishing edge, leaving bars for pedestals & sleepers, including providing sand fill isolation, shuttering providing and fixing reinforcing steel, curing, chipping and modification works etc. as specified in any shape, thickness, position and finishing the top surface smooth as per requirement etc. all complete as per drawings, specifications and directions of the EIC/ SIC.
Providing brick work with brick class designation M 5.0 of IS:1077 in cm 1:5 (1 cement 5 sand) in steps, walls, retaining walls and load bearing structures drains, or any shape with all lead, depths & height including curing scaffolding etc., as per specifications and drawings with all bye-woks and direction of the EIC/ SIC.
Brick valve chamber - Size (L x W) - 2m x 1m
RCC valve chamber - Size (L x W) - 2m x 1m
Brick valve chamber - Size (L x W) - 1.5m x 1m
RCC valve chamber - Size (L x W) - 1.5m x 1m
Brick valve chamber - Size (L x W) - 2m x 1m
Civil & Structural Works
This item is for miscellaneous jobs including supply of Brick, Cement, Sand, Aggregate, Steel etc.
Brick Works
PCC Works (M20)
RCC Works (M20)
Reinforced Steel
Structural Steel
Angle F/Pipe Support 32x32x3mm
PART-D (LMC SECTION)
Installation of GI service pipe & fittings
Survey of designated area and survey drawings of societies / colonies/ localities shall be provided by the contractor. installation of GI fittings like elbows, tees, unions, sockets, reducers, GI plugs,any other GI fittings, adopter for appliance valves & Anaconda, Domestic Adoptor, GI Sleeves, RCC Crimping Guard, Meter clamp & Pipe clamps etc. as required to complete the job including supply of all consumables like Teflon tape, soldering consumables, flux application and all other required material to complete the job. Excluding only Supply of GI pipes of all dia.,GI fittings, Isolation valve, appliance valve,brass adopter Anaconda, Meters,Regulators,Suraksha hose pipe with clamps,GI sleeves,HDPE guard & GI fittings which shall be issued by Owner as FIM.
Receiving and taking-over as defined in the scope of work & specifications, handling, loading, transportation and unloading of owner supplied GI pipes of all dia.,GI fittings, Isolation valve, appliance valve,brass adopter Anaconda, Meters,Regulators,Suraksha hose pipe with clamps,GI sleeves,HDPE guard , GI fittings and other free issue items from owner's designated place(s) of issue to contractor's own stock-yard(s)/ Work Shop(s)/ work-site(s) including proper storing, stacking, identification, providing security & insurance cover, including installation of GI line (alongwith installation of required accessories as mentioned above) of following sizes, including fabrication, consumables, labour and other incidental works and handing over the same after return of the surplus pipes, fittings, valves & other accessories to the owner's designated store; carrying out all temporary, ancillary, auxiliary works required to make the GI line ready for commissioning as per drawings, specifications, scope of work and other provisions of contract document and instructions of EIC/ SIC, including but not limited to carrying out the following:
Preparation and approval of schedules, execution procedures, sketches
Finalization of optimum route with consent of customer, from transition fitting to cooking oven/ appliance. A tentative sketch shall be prepared and shall be signed by customer, contractor & SIC/ TPIA
Making temporary but stable platforms/ scaffolding / rope ladders and all other safety devices
Installation of Powder Coated GI Pipes & Fittings, Isolation & Appliance Valves including NPT/BSPT threading, Anaconda, Suraksha Hose etc.. painting as specified including installation of regulators and meters.
Supply & Fixing of approved, clamps, Dowell Plugs with screws, grout material, suitable thread sealant i.e. Teflon Tape/ lock tight, drilling of holes through wall /tiles / wood/ marble/ Granite etc jointing of PE to aboveground service GI pipes, testing, purging and commissioning of the complete installation.
Touchup/ Painting of entire length of pipe along with fittings after proper surface finish by one coat of approved primer paint and two coats of approved synthetic enamel paint complete as per specification & direction of EIC. Restoring the wall surface to original by cleaning/ touching of corresponding paint to original as per instructions & to satisfaction of the owner. Preparation of laying records, meter reading etc. Reconciliation of free issue material.
Drilling of holes through walls with proper heavy duty hammer drill Machine, tools & tackles, using proper sealant/ grout material & colours to match original, replacement of damages during drilling, restoring the area to original condition to the satisfaction of Owner/ EIC & as per specification for 1/2" & 1" NB in brick wall and RCC wall. PVC sleeve with proper sealant to be provided in the drilled section to protect GI pipe.
All above activities to be carried out as per scope of work, specifications and to the complete satisfaction of consumer & EIC/ SIC.
Handing over the completed works to owner for their operation/ use, returning of all free issue surplus material to owner stores, reconciliation of free issue material area wise and obtaining "no objection certificate" from owner/ EIC/ SIC/ TPIA
Any other activity not mentioned/ covered, explicitly above, but otherwise required for satisfactory completion/ safety/ statutory/ maintenance of works shall also be covered under scope of work and has to be completed by contractor within specified schedule at no extra cost to owner
Arrangement of all tools, tackles and consumables required to execute the work in an efficient manner.
NON LMC
Installation of powder coated GI riser of 1” & ½” from TF to Riser Isolation Valve, from Riser Isolation Valve upto lateral Isolation Valve by providing plug at all levels upto all floors including supply and fixing of all type of pipe supports/ clamps/ brackets.
Installation of Welded powerder coated GI/ MS riser at all length in buidlings above 8 floors and confined spaces like basements by using forged fittings confirming to IS 1239 - Part 2, duly polyester powder coated with 70 micron thickness. GI pipe & required fittings shall be first coupled with threaded joint. Teflon/PTFE tape should not be used in threaded joint for welded riser. Alternatively, plain ended pipes and fittings can also be used for welding in welded riser.The entire riser shall be constructed with SOCKET weld only, threaded joints are permitted only on the laterals on account of workability & for future maintenance only. The electrodes (Welding Rods) used for welding on risers shall be of E 6013 grade & 2.5mm thickness of reputed make used for industrial application. The Vendor is required to provide the Batch Test Certificate (TC) for the electrodes. The Weld joint shall be thoroughly cleaned with wire brush and examined visually for its quality. Welding shall be free from defects like porosity, crack, undercut, incomplete fusion etc. Spatter, slag must be removed from pipe.
Installation of 1" powder coated GI Riser from TF to Riser Isolation Valve of 1" (included) with GI length of 1.5 meter from TF, including installation of padestal for TF
Installation of 1/2" powder coated GI Riser from TF to Riser Isolation Valve of 1/2" (included) with GI length of 1.5 meter from TF, including installation of padestal for TF
Installation of 1/2" powder coated Gl pipe from Riser Isolation Valve (excluded) upto lateral isolation valve (excluded) at all levels upto G+3 floor with end cap/ plug (included).
Installation of 1/2" powder coated Gl pipe from Riser Isolation Valve (excluded) upto lateral isolation valve (excluded) at all levels more than G+3 floor with end cap/ plug (included).
Installation of 1" powder coated Gl pipe from Riser Isolation Valve (excluded) upto lateral isolation valve (excluded) at all levels more than G+3 floor with end cap/ plug (included).
Inst. of 1" horizontal GI/ MS pipe-Welded ( Inside Basement)
Inst. of 1.5" horiz. GI/ MS pipe-Welded ( Inside Basement)
Inst. of 2" horizontalGI/ MS pipe-Welded ( Inside Basement)
Inst. of 1" vertical GI/ MS pipe-Welded.
Inst. of 1.5" verticalGI/ MS pipe-Welded.
Inst. of 2" vertical GI/ MS pipe-Welded.
Supply & Installation of Anchor GI/ MS Clamp 1" to 2"
RCC Breaking Hole in Basment
Labour chrg F/nitrogen flush,test&mobilization
Common Estimate in Society / Apartment
Installation/Fixing of Commercial/Non-Commercial meter and regulator with associated inlet & outlet connections fittings,anaconda,valves. Using approved meters & regulator brackets and other supports by proper scaffolding/grouting. Restoring the area/walls to original condition as per specification and to complete satisfaction of consumer and EIC.
Installation of 1/2" Powder Coated GI pipe & Fittings with Installation of lateral isolation valve (included) at all length after lateral isolation valve along with installation of regulator, meter with associated inlet & outlet connections/ fittings/ anaconda, supply and fixing of approved meter brackets and other supports upto Appliance Valve (excluded). Installation of Appliance Valve is covered in Conversion of Domestic Appliances.
Installation of 1/2" Powder Coated GI pipe & Fittings at all length up to appliance valve/gas tap at domestic household for connecting PNG connection with GI Riser network with end cap/ plug (included).
Connection ready for commissioning (RFC) by installation of lateral isolation valve (included) at all length after lateral isolation valve along with installation of regulator, meter with associated inlet & outlet connections/ fittings/ anaconda, supply and fixing of approved meter brackets and other supports upto appliance valve (excluded).
Conversion of Domestic Appliance
Conversion of all types of LPG kitchen appliances to NG based appliances by installing appliance valve, suraksha hose of 1 meter, changing/ converting nozzles, jets and associated controls for domestic & imported appliances with proper tools & tackles.
Cleaning and performing minor maintenance, greasing etc of appliance, testing/ showing performance to the customer, signing of joint meter records (JMR) and instructing customer on use & safety norms, complete as per scope of work, specifications & to the satisfaction of owner/ EIC/ SIC.
2 Burner Stove
3/4 Burner Stove
Cooking Range
Geyser
Other Applicances
PNG Connection in Commissioned and O&M Areas
Installation of 1/2" Powder Coated GI pipe at all length after lateral isolation valve upto appliance valve along with installation of meter with associated inlet & outlet connections/ fittings/ anaconda, supply and fixing of approved meter brackets and other supports. The scope of this SOR is from installation, testing, commissioning upto conversion of all types of Stove/ burner/ Cooking Range/ Applicances
Installation of 1/2" Powder Coated GI pipe & Fittings at all length up to appliance valve/gas tap at domestic household for connecting PNG connection with GI Riser network with end cap/ plug (included).
PNG Connection asembly such as installation of lateral isolation valve upto appliance valve along with installation of meter with associated inlet & outlet connections/ fittings/ anaconda, supply and fixing of approved meter brackets and other supports. in Old Project and O&M Areas
Bidder Name
Amount in Words
Bighnahanta Construction Pvt. Ltd.
TECHNO GLOBAL SERVICES PVT LTD
Shree Polkaji Enterprises
ARIMECH INDIA PRIVATE LIMITED
Aditya Traders
NORTH STAR TECHNO SERVICES PRIVATE LIMITED
EMBRACE GAS PIPELINES PVT. LTD.
Ruby enterprises
Tejas Construction
ROCKERR INFRASOLUTIONS PVT LTD
NOPS INFRASTRUCTURE PVT. LTD.
GREENTECH ENGINEERS
ROCKERR INFRASOLUTIONS PVT LTD
Ruby enterprises
NORTH STAR TECHNO SERVICES PRIVATE LIMITED
EMBRACE GAS PIPELINES PVT. LTD.
Tejas Construction
Aditya Traders
ARIMECH INDIA PRIVATE LIMITED
GREENTECH ENGINEERS
TECHNO GLOBAL SERVICES PVT LTD
Bighnahanta Construction Pvt. Ltd.
NOPS INFRASTRUCTURE PVT. LTD.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .