Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68,808Accepted-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L1 | Accepted-AOC accepted |
Tender Value
₹68,115
EMD Value
₹1,703
Closing Date
25 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE
AE OFFICE LID EW SECTION MUNDAKKAYAM
DWP ELECTRIFICATION
2024_LSGD_697177_2
1A/AE/LIDEW/2024-25
Open Tender
Electrical Works
Percentage
120 days
MUNDAKKAYAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹1,703
4 Jun 2025
16 Jan 2025
27 Jan 2025
16 Jan 2025
25 Jan 2025
16 Jan 2025
Amount
ELECTRIFICATION
OD276369/2023-2024:Supply conveyance erection testing and commissioning of 1.1 KW/1.5 HP Cast Iron Single Phase Centrifugal Monoblock Pump set having a head range of 6/27 meters and discharge between 267/136 lpm suction side 40 mm and delivery side 32mm 1 1/4" dia working with 220 V 50 Hz set etc. as required (ACS1130 Aquatex/TEXMO or Equivalent make)
OD276370/2023-2024:Supply and providing BCH make DOL Starter suitable for 1.5 HP single phase Cast Iron Single Phase Centrifugal Monoblock Pump set with protection against overload RELAY 1 PHASE 8.9-13.5 16A , in accordance with latest IS/IEC 60947-4-1 specifications duly internally connected
OD276373/2023-2024:Supply and providing Adapter set suitable for I.5 HP submersible pump set
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD276372/2023-2024:Supply and Providing Dutron Kanaflex M.D. (Green) 40 mm Suction Hose Working Pressure 5.0 kg/cm2 at 30 Degree C, Bursting Pressure 16.0 kg/cm2 at 30 Degree C, OD Diameter 43.3 +- 1.0 mm and ID 38.0 +- 0.5 mm, Bending Radius 95 mm
OD276374/2023-2024:Supply and providing 40mm MTA
OD277941/2023-2024:Supply and providing CRI/TORMAC Cast iron foot valve CI 40MM 3B
OD277950/2023-2024:Supply and providing hose collar CI 40mm medium
OD277981/2023-2024:Supply and providing hose clip screw type steel 40mm
OD276375/2023-2024:Supply and Providing 40mm ( 6kg/CM2)PVC pipe with accessories etc
90.17.14.1:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :40mm dia
OD276377/2023-2024:supply and providing 32mm Socket
OD276378/2023-2024:Supply and providing Nut& Bolt with washesr 2x5/8
OD276379/2023-2024:Supply and fitting 32 mm GI Bend on pumping main
OD276380/2023-2024:Supply and providing TEE GI 32mmX25mm ISI
OD276381/2023-2024:Supply and provide CI 32mm (H) Clamp set for pumpset
OD277985/2023-2024:Supply and providing of Threaded 25 Mm GI Hex Nipple ISI
OD277994/2023-2024:Supply and providing Krishika Tipe Medium Pressure PVC Ball Valve 32 mm (1" ) Threaded
OD277997/2023-2024:Supply and proving reducer GI 40mmX32mm ISI
OD278004/2023-2024:Supply and providing hose collar steel 40mm X6"
OD278240/2023-2024:Supply and providing 32 mm /40 mm flange with bolt and nut
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD276382/2023-2024:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 30/100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. rating, 2 pole RCCB, 100mA/300mA
OD278272/2023-2024:Supply and fixing 40A, backelite HRC Fuse Base with HRC Fuse link in existing meter board and giving connections etc.
OD278309/2023-2024:Supply and fixing of 32 A, 2 Way neutral links mounted on DMC/SMC base in existing meter board and giving connections etc
OD276383/2023-2024: Earthing with G.I. earth plate 600mm X600 mm X 6 mm thick with watering pipe 1.7 metre long and test joint using 2 nos ,25x3mm GI Strip with sufficient drilled holes minimum size 25 cm suitably shaped and tightly clamped to the watering pipe using 25x6 mm steel bolts nut and washer and providing 2 nos, 20x3 mm GI strip from test joint to earth plate bottom level clamped at 2 locations on the plate and on the test joint bolted with steel bolts,nuts etc ,providing GI funnel welded with the watering pipe and making masonry chamber built with bricks and duly plasterd and providing cast iron cover plate etc complete
OD276384/2023-2024:Supply and providing 12x3 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD276385/2023-2024:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD276386/2023-2024:Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availng 1 phase service connection/Load regularization
OD276387/2023-2024:Supply and providing anchor bolt hook type on wall /parapet for binding KSEB Service connection capable as required.
OD276388/2023-2024:Supply and installation of dust and Vermin proof wall mounding meter box (300x300x170mm )SINTEX make with base plate suitable to fix single phase energy meter and fix to fix in the box one set of 32 A,415 V HRC Bakelite fuse fitting with HRC fuse link,32 A 2 way neutral link etc
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
OD278575/2023-2024:Charges for preparing installation completion report for submitting to KSEB
Bidder Name
Angel electricals
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1156815.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .