| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹10.4 L+₹887.30 (0.09%)Rejected-AOC | ₹10.4 L+₹887.30 (0.09%) | L2 | Rejected-AOC Second lowest |
| 3 | L3₹10.6 L+₹21,433.30 (2.06%)Rejected-AOC | ₹10.6 L+₹21,433.30 (2.06%) | L3 | Rejected-AOC Third lowest |
| 4 | L4₹11.0 L+₹62,027.67 (5.97%)Rejected-Finance LEKSHMI DHATHAM VP 4 132 A PEYAD VILAPPIL PANANGODE 695573 | PANANGODE | THIRUVANANTHAPURAM | KERALA | 695573 | ₹11.0 L+₹62,027.67 (5.97%) | L4 | Rejected-Finance Fourth lowest |
| 5 | L5₹11.3 L+₹90,203.30 (8.68%)Rejected-Finance VELLAPLACKAL HOUSE VARANDARAPPILLY PO THRISSUR 680303 | THRISSUR | THRISSUR | KERALA | 680303 | ₹11.3 L+₹90,203.30 (8.68%) | L5 | Rejected-Finance Fifth Lowest |
Tender Value
₹11.7 L
EMD Value
₹29,300
Closing Date
20 Jul 2023, 6:00 pmClosed
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
NABARD XXVII_ Additional Infrastructure Facilities at Chellanam Fishing Harbour_ Electrification Netmending shed, shops, locker room, canteen and rest room
2023_HED_587517_1
10/HEED/2023-24/e-T/S
Open Tender
Electrical Works
Item Rate
60 days
Ernakulam
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹29,300
23 Sept 2023
12 Jul 2023
22 Jul 2023
12 Jul 2023
20 Jul 2023
12 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar,earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator2 + 8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supply Conveyance, installation, testing and commissioning of SID or equivalent make Street light luminaire, 20W LED, IP66 optical & control gear compartment, die cast aluminium painted housing,anti UV Polycarbonate protector with in built individual lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 105 Lumen/W at Ta 25,Total 2100 lumens. Lifetime residual flux @ Tq 35C @ 50,000 hours = 70%, Ta = 50C, in built surge protection of 4kV (in Differential and Common mode) power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700K).THD<10%,5 year warranty for the luminaire.
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying 20W LED Tube with fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent
Supply of Exhaust fan 305mm sweep single phase, heavy duty 1400 RPM, Almonard or Equivalent in metal frame and installation on the existing opening with required accessories and making good the same.
Supply and installation of wall mounting cubicle type Hensel make Mi 9300 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 450 x 315 x 170 mm , IP65 with base plate for fixing KSEB meter, cut out & Neutral link and 32A , 10kA SPN MCB, C curve , with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 32A,10kA ,SPN MCB C curve , 1 No 32A HRC fuse units with 32A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire
Supply installation testing and commissioning of wall mounting type single phase metering panel made of polycarbonate outdoor type metering panel board made of thermo plastic polycarbonate enclosures,the enclosure shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Degree of Ingress Protection IP 65 shall be in accordance with IEC 60529.The panel shall be comprising of the following and shall be fully wired as per latest electrical standards and all necessary accessories,ready to use(Make:Hensel or equivalent). Incoming:63A DP MCB 10kA - 1No Outgoings:Provision for fixing 1Phase KWH meter – 5Nos, 32A HRC Fuse base with links - 5Nos,32A Neutral link – 5Nos,32A DP MCB 10kA – 5Nos
Providing and fixing 10.00 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required
Supplying and fixing tinned 25x3mm copper strips having sufficient number of holes of 3/6mm dia as required on surface of wall using nuts & bolts as earth bus
KSEB Documentation Charge
Supply of superior quality copper earth socket for the 6 SWG earth conductor including crimping etc. as required
Providing and fixing 12 SWG insulated GI wire for service wire binding along with service line complete with all accesaries complete as required
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door
supply of weather proof LED luminaire having power consumption not more than 20 W and light output not less than 2100 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. Preferred make Philips WT 150C LED 20S-6500 PSU L120 or equivalent
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings)
Supplying and fixing brass batten/ angle holder including connection etc. as required
Supply and fixing 7/9 W LED, BC, lamp OSRAM or equivalent
Supply and fixing HINGEDJunction box minimum dimension of 85x85x45 made of Thermoplastic Glass Fiber Reinforced Polycarbonate, UV resistance,IK08 Degree of Ingress Protection IP 65in accordance with IEC 60529,including 5 Pole Copper Terminal Set, pre punched / knock out for cable entry in all the four sides as well as on the back side, rated insulation voltage has to be min 690V., thermoplastic JB shall be fire retardant & self-extinguishing, the combustion behavior shall be in accordance with VDE 0471 / UL 94 for 960degC. The screws has to be made of stainless steel. . Make: Cape/Spelsberg/Hensel
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 3-14W LED lamps including connection etc as required.
Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
Supplying and fixing HENSEL make KV - thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 1 rows 4 modules size 126 x 228 x 111 KV 7103 with PE+N terminals
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
JOSE P C
Edward P J
CALL ON ELECTRICALS
BINSON JOSEPH
Franjo Engineering Corporation
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_868671.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .