Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹432.6 CrAccepted-AOC | ₹432.6 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹458.8 CrRejected-AOC | ₹458.8 Cr | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹483.5 CrRejected-AOC B 22 2ND FLOOR HIMALAYA HOUSE 23 K G MARG CANNAUGHT PLACE NEW DELHI 110 001 | NEW DELHI | DELHI | 110001 | ₹483.5 Cr | L3 | Rejected-AOC L3 bidder |
| 4 | Rejected-Technical C 102 ANSAL PLAZA HUDCO PLACE KHELGAON MARG NEAR SOUTH EXTENSION NEW DELHI 110 049 | - | - | Rejected-Technical The submitted documents do not meet the pre qualification criteria |
| Sl No | Description | Qty | Unit | JATAN CONSTRUCTIONS PVT LTD L2 | Consolidated Construction Consortium Limited L1 | Bridge And Roof Co. (I) Ltd. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Civil Works
Transportation of Earth by Mechanical means including loading,unloading and stacking upto 1km as per direction of engineer incharge | 46,639 | Cum | 83 ₹38.7 L | 22 ₹10.3 L | 208 ₹97.0 L |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil. | 62,648 | Cum | 198 ₹1.2 Cr | 178 ₹1.1 Cr | 278 ₹1.7 Cr |
| 3.00 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. | 148 | Cum | 248 ₹36,704 | 213 ₹31,524 | 208 ₹30,784 |
| 4.00 | Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered):
Depth not exceeding 1.5 m | 20 | Sqm | 495 ₹9,900 | 1,258 ₹25,160 | 347 ₹6,940 |
| 5.00 | Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered):
Depth exceeding 1.5 m but not exceeding 3 m | 20 | Sqm | 825 ₹16,500 | 1,384 ₹27,680 | 486 ₹9,720 |
| 6.00 | Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered):
Depth exceeding 1.5 m but not exceeding 3 m | 20 | Sqm | 825 ₹16,500 | 1,523 ₹30,460 | 625 ₹12,500 |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 14,936 | Cum | 215 ₹32.1 L | 209 ₹31.2 L | 278 ₹41.5 L |
| 8.00 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil. | 70,778 | Cum | 66 ₹46.7 L | 22 ₹15.6 L | 167 ₹1.2 Cr |
| 9.00 | Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete. | 59 | Cum | 5,642 ₹3.3 L | 4,619 ₹2.7 L | 4,305 ₹2.5 L |
| 10.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 16,458 | Sqm | 25 ₹4.1 L | 44 ₹7.2 L | 69 ₹11.4 L |
Tender Value
₹380.1 Cr
EMD Value
₹5 L
Closing Date
13 Oct 2025, 5:00 pmClosed
CEO Technopark
Park Centre building, Technopark Phase 1 Campus
Construction of an IT Office building
2025_ETPK_764002_2
ETPK/TC/227/2025-26
Open Tender
Civil Works - Buildings
1095 days
Technopark Phase 4 campus (Technocity)
As mentioned in Bid document
7 documents required · 7 mandatory
₹17,700
₹5 L
Park Centre building, Technopark Phase 1 Campus
1 Jan 2026
25 Aug 2025
14 Oct 2025
25 Aug 2025
13 Oct 2025
17 Sept 2025
16 Sept 2025
Amount
Civil Works Transportation of Earth by Mechanical means including loading,unloading and stacking upto 1km as per direction of engineer incharge
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 60 cm girth upto and including 120 cm girth
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 120 cm girth upto and including 240 cm girth
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
Extra rates for quantities of works, executed: In or under water and/or liquid mud, including pumping out water as required. The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these difficult conditions. The unit, namely, metre depth, to be considered for payment, shall be the depth measured from the sub soil water level up to the centre of gravity of the qty executed in difficult conditions. The depth shall be reckoned correct to 0.10 m, 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Cantering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. The quantity will be calculated by multiplying the depth measured from the sub-soil water level up to centre of gravity of concrete under sub-soil water level with quantity of concrete in cum executed under sub-soil water. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of cantering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.sand and aggregate derived from natural sources. Note : (1) Excess/less cement used than specified in this item is payable/ recoverable separately. (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC." All works above plinth and upto floor V level: M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) (SCREED)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) (SCREED)
Centering and shuttering including strutting, propping etc. and removal of form Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form Walls (any thickness) including attached plasters, buttresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
Centering and shuttering including strutting, propping etc. and removal of form Extra for shuttering in circular work (20% of respective cantering and shuttering items) wall
Centering and shuttering including strutting, propping etc. and removal of form Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Edges of slabs and breaks in floors and walls Under 20 cm wide
Edges of slabs and breaks in floors and walls Above 20 cm wide
Extra for additional height in cantering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Design & Execution of Post Tensioning works including decoiling the strands, cutting to the required lengths, supplying and laying of HT strands, sheathing(GI Plain/Corrugated ducts 48mmx20mm/80mm x 20 mm) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages including the supply of stressing anchorages suitable for 3B13 & 5B13 Tendons, grout vents, making dead end anchorages including flowering the strands, fixing tendon support bars, supervising the fixing of anti bursting reinforcement, stressing the cables, end trimming, grouting the cables with cement and admixtures, with required Plant & Machineries, tools and tackles, consumables etc., including obtaining approval from client/consultant for the work done as per the requirement of Engineer-In charge at site. The pre stress design shall be done for Type 2 & Type 3 stress conditions in gravity and earthquake load respectively, including providing and supplying the tendom, cost of non shrink in duct /sheathing.
Providing and fixing sheet covering over expansion joints with iron screws as per design. 400 mm wide
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/ cum)
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-50 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-50 is @ 380 kg/cum)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of cantering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer -in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of cantering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer -in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level
Extra for RCC/BMC/RMC work above floor V level for each for floor or part thereof: (i.e. upto 4th floor) from 4th upto 8th Floor
Extra for RCC/BMC/RMC work above floor V level for each for floor or part thereof: (i.e. upto 4th floor) from 8th upto 12th Floor
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge .(Material shall confirm to ASTM 6063). Floor Joint of 200 mm gap.
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 200 mm gap.
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movementwithout stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates / moves in all directions.The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063. Roof Joint of 200 mm gap.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. (i.e. upto 4th floor) from 4th upto 8th Floor
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. (i.e. upto 4th floor) from 8th upto 12th Floor
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 superstructure above plinth level upto floor V level.(i.e. upto 4th floor) Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. from 4th upto 8th Floor
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. from 8th upto 12th Floor
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in- Charge. (The payment of RCC band and reinforcement shall be made for separately).
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing machine cut, mirror/ eggshell polished , Marble/Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc at all levels., in required design and pattern wherever required, stones of slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement 18 mm thick Granite of any colour/ shade (Basic Rate is Rs.1800 / Sqm)
Providing and fixing wooden wall panelling using 50x25 mm MS duly painted base frame @ 600 c/c bothways and fixing 12 mm marine ply. Over this base wall paneling 1 mm thick laminate in approved shade and colour shall be pasted as per designs shown on drawings.including providing grooves and anodized aluminium profiles in approved colour.
Acoustical wooden wall panelling Providing and fixing of Acoustical Wall Paneling of approved make with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A as per ASTM E-84, fabric with approved color, in size 600X1200 mm, having density of 100kg/cum, NRC of 0.7 , to be affixed to wall using Wall panel impalers supplied as per the manufacturer instructions, 4nos.wall panel Impalers shall be fixed to the wall surface using self-tapping screws, wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained, installation to be carried out by Trained Installation team & Installation should be carried out as per Manufacturer recommendations, all complete as per direction of engineer in charge
Providing & Fixing Acoustical fabric panelling with approved Fabric of approved make, over 6mm thick foam, both wrapped over 9 mm thick tacable board which is pasted with approved adhesive / nails on existing ply base, including fixing of grippers on existing wooden surface (ply/MDF), streching & fixing of fabric in grippers, all complete as per drawings & direction of engineer in charge. The fabric shall be of approved make (Basic rate of fabric shall be Rs 200/- per running meter, considering fabric width of 1.4m). (MS Frame work shall be paid for separately).
Acoustical Slats. Slats Spots MP3 Lite,192 x2440x16mm, T&G edge,melamine Wall Paneling Supply & installation of Slats Spots MicroPerforated 3mm Lite, made of pinewood E1 grade fiberboard, melamine finish, having 3mm dia circular microperforations @ 16mm pitch, backlined with Soundtexblack acoustical fleece of 0.27mm thick, surface density 63g/m2, tongue-groove edge for a seamless look, 1-test FR grade, size 192 x2440x16mm, volume density of base board 700Kg/m3, weight of base board 11.2Kg/m2 installed by using Strut framework system. "The Strut framework system shall include Strut CC25, fully knurled, sectional thickness 0.55mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned horizontally/vertically at every 600mm centres. Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC25 with the help of fasteners at every 400mm centers. Slats Spots MP3 Lite of size 192x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise." The system is backlined with SynthPolyfiber10x25 held in position with dab spots of stick S7/wire mesh (not by ). Technical Parameters "• Fire (Class) – B • Acoustics – NRC 0.75( For C40 Mounting) • Climate (°C, RH) – 50, 70 • Light reflectance (%) –75 (Maple Arce) • Green (VOC, RC %) – E1, 25" Including material and installation cost all complete
Providing and fixing 6mm thick Lacquered glass of approved make on wall panelling over 12mm thick marine plywood/BWP ply base (conforming to IS : 710) fixed over MS frame work. Glass shall be fixed with clear neutral silicon of make GE winsil 20/ silpruf or DOW CORNING 995 over plywood complete as per detail in drawing and directions of Engineer-in-charge. Plywood cost is included in this item. MS Frame work will be paid separately.
Provding and Fixing of 12mm Aluminium profile in anodised finish in approved colour and shade of L or T shape to be fixed with chemical adhesive. Complete as per drawing to be issued.
GLASS PARTTION Supply & Installation of Saint-Gobain Clipper Sleek Series Partition of aluminium profile with Clip-on / U-Section of size 30mm x 21mm with 2.5mm Wall thickness in matt black/ Natural Alu finish. Partition to be provided with suitable gaskets for insertion of 10mm thick clear Saint Gobain toughened glass. Partition Glass joineries consists of two-way Polycarbonate I-profiles, 90 Degree Polycarbonate L-Junction and Polycarbonate T-Junction profiles. Polycarbonate profile joineries to be fixed with double sided adhesive tape & profiles to be inserted in the joint instead of sealing it with sealants. Polycarbonate profiles to be used at glass to glass joineries to give continuity glass effect. Hardware for fixing profiles to be used as per manufacturer standard. Costs should be inclusive of necessary Hardware for fixing of profiles & installation charges. SINGLE GLAZED FIXED PARTITION WITH 10MM GLASS
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Square or Rectangular
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50x12 mm
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 250x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partition with 12.5 mm thick doubleskin tapered edged plain Gypsum board conforming to IS:2095: part I
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled orpanelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick ( Basic Rate is Rs. 430 / Sqm)
Providing and fixing stainless steel door buffer/stopper fixed to Floor Mounted including other accessories as required and as per drawings, specifications and as directed complete
Providing and fixing Stainless steel tower bolt with necessary screws etc. complete. 300x10 mm
Providing and fixing aluminum U beading of required size to Pre-laminated/ flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Providing and fixing of Fully Insulated Non Metallic Wooden doors as per IS 3614:2021, for 120 min integrity & insulation. The door is manufactured made out of thoroughly seasoned hard wood ( (Red meranti teak / Ivory Coast teak (2nd class )/Teak wood)). The moisture content of any material used in the construction of wooden composite fire door sets comprises of both frame and shutter shall not be more than 15% approx. in accordance with IS 287. The fire door must have earlier test evidence as per IS/ISO 3008-1. It must have successfully tested from CBRI , Roorkee / NABL accrediated lab which operates in accordance with ISO/IEC 17025 for its fire rating. Door and frame shall be finished with fire retardent primer of approved make, All accressesories like hardware, vision panel, fire seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021. Every door must carry a label confirming to type of door & its fire rating. Door Frames : Main Door frame of profile of section 120 x 70 mm made out of Hard wood (Red meranti teak / Ivory Coast teak (2nd class )/Teak wood) with factory made groove of suitable size so as to accomodate intumuscent Fire seal of size 20x4mm , including providing fire seal of 20x4mm size on all three sides of frame except bottom , the frame must be primed with Fire retardant primer of approved make, the frame shall be fixed with 8 nos of anchor fastners of HILTI/ FISHER/ Equvalent of M10X120mm length or as per direction of Engineer-in-charge. Door Shutter : Wooden shutter internal frame work made of teak wood treated with fire retartdent primer/polish, thickness of door shall be minimum 50mm but not more than 55mm suitable for mouting on door frame , finished with 3mm thick commercial ply on both faces. The Commercial ply should be pasted with 1mm thick Laminate ( of approved color ) on both faces in desired finish shade .The shutter insulation core shall consist of fire rated mineral wool insulation of suitable thickness treated with fire retardent paint , sandwiched between Calcium Silicate boards of suitable thickness as per fire door manufacturer. The shutter should be provided with heat activated intumescent fire seal strip of size 20mm x 4 mm mounted in the suitable grooves all three sides except bottom, provided on Exposed OR concealed wooden lipping, including fixing of door shutter with SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws of BB1953 Becker Fire Solutions / DORMA 3090F / Hafele/GEZE Make ( 4 Nos per panel ) or approved equivalent Vision Panel wherever applicable should be provided with minimum 5mm thick single layered clear fire rated glass panes as per guidelines laid down under IS 3614 2021 vide clause no. 7.2.7 table no. 2 fixed in the shutter using z shape wooden beading. Every Glass panel must carry a permanent marking of its glass manufacturer Finish: - The door frame and door shutter lipping shall be finished with minimum two or more coats of fire-retardant enamel paint / polish for scratch resistance and durability on hard wooden surface (@3.5 sq. mtr. per ltr. per coat) including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. The paint shall be of approved brand and quality as per list of approved makes, including supply and Filling the gap between wall & Door frame by using silicone sealant and Wool insulaion on both side of the door (For payment purpose the area of opening including door frame shall only be measured) (Cost of Hinges is included in above item. However, items like glass vision panels, pull handles, door closer, panic bars, locks shall be paid separately)
Providing & fixing Fire rated Lock with cylinder with both sides key and key hole cover of approved make certified for 2Hrs fire rating, all complete as per direction of Engineer in Charge.
Supply & fixing of Stainless Flush Bolt of approved make with necessary screws as required. 300mm long
Providing and fixing Round edge beading thickenss 1.2mm with depth and profile as approved made of co-extrusion fixed by placing the beading on edge of tile surface with side without punched holes butting the surface and lay the tiles on other surface by allowing mortar filling and ensure that mortar penetrates the adhesive holes complete as per manufactureres specifications.
Providing and fixing Inner Corner bead of PVCU and PVC thickenss 1.2mm with depth and profile as approved made of co-extrusion fixed by placing the beading on edge of tile surface with side without punched holes butting the surface and lay the tiles on other surface by allowing mortar filling and ensure that mortar penetrates the adhesive holes complete as per manufactureres specifications.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 140 mm
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Extra for providing and fixing 12 mm thick toughened glass of approved make and shade in SS railing including providing and fixing all necessary accessories, fittings, studs , etc of SS 304 grade all, complete as per drawing and direction of Engineer in charge
Providing and fixing atrium floating staircase (ground to first floor) with vibration gold finish steel as per drawing, design and dorection of engineer in-charge.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing of min.50 mm thick at all levels & locations, 120 minutes fire rated steel Fire door and frame of Galvanized steel conforming to IS:277 of approved make, overall door assembly conforming to IS 3614: 2021 and NBC 2016 as required . Fire doors should be tested at CBRI, Roorkee rating of 120 minutes of stability & intigrity and 30 minutes of insulation criteria. Frames should be of minimum 16 gauge thickness of section 150mmX57mm with groved 10mmX4mm thick fire and smoke seal provided in the rebate of the door frame with back plate bracket for hinges, anchor fasteners for installation on a finished plastered masonry wall opening. Frame should be filled with mineral wool panels necessary for fire doors on the clear masonry opening. Door shutter shall be made with minimum 18 gauge thick steel pressed formed to provide 50 mm thick fully flush double skin door shell with lock seam joints at stiled edges. The internal construction or in fill material of the door shall be to meet desired fire rating and insulation criteria with reinforcement/rails at top, bottom, middle and vertical stile. The infill material shall be 96kg/ m3 mineral wool/rockwool.The door shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers etc complete. The edges should be interlocked with a bending radius of 1.4mm. and shall have door astragals of required profile and size provided on the meeting stile for both active and inactive leaf. The shutter is to be fixed with frame with SS ball bearing butt hinges of size 102 x 76mm x 3 mm thick from approved brand. Frame shall be fixed with approved dash fasteners of size 10 mm dia x 100 mm long (Hilti / Wuerth) and shall not be kept hollow (filled with mineral wool panels). Vision panel shall be provided in all doors of maximum size 200 x 300mm as per the requirements of IS codes and manufacturers recommendation with clip on beading and no screws from inside or outside on the surface shall be visible. The glass for vision panel should be minimum 6mm clear fire rated glass of approved make & of 120 minutes fire rating. Door frames and shutters to be finished with power coating (minimum 60 micron), all complete as per the specifications and directions of Engineer-In-Charge and as per the approved RAL shade of the architects. (Rates of Fasteners, Rock wool Insulation Panel & Fire Seal are inclusive of the item and all Hardware i.e. locks, door closer, Panic bar and vision panels etc shall be paid for separately).
VISION PANEL: Providing and fixing vision panel of maximum size of 300 x 300mm as per NBC 2016 and IS 3614: 2021 in metal fire rated single/double leaf doors with minimum 6 mm thick clear ceramic glass of approved make for 120 minutes fire rating. The glass shall be fixed in the opening left in the door shutter for vision panel by GI beading, ceramic fiber tape and fire rated acrylic sealant/seal etc all complete as per the directions of Engineer-in-charge.
DOOR CLOSER: Providing and fixing Aluminium extruded body Standard arm door closer with necessary accessories and screws etc all complete as per the specifications of the approved vendor and as per the directions of the Engineer-incharge. It should be of size 3-4, nonhanded having back check and delayed action and shall complying with EN: 1154 and shall be tested from CBRI roorkee as per IS Part II & BS 476 Part-20 & 22 , The door closer shall have 10 years mechanical warranty from the manufacturer and complete with EN 1154- for 100000 cycles. (For leaf with maximum width of 1200mm and height of 2100mm)- The manufacturer shall extend a 10 year replacement warranty.
HINGE: Providing & Fixing of Stainless Steel Ball bearing Hinges of size 102 x 76 x 3mm along with stainless steel screws suitable for Metal/ Wooden and Stainless Steel glazed doors. The manufacturer shall extend a 10 year replacement warranty.
D- HANDLE: Providing and fixing of 2 hours fire rated 304 grade stainless steel fire rated D- Type back to back pull handle of size 300mm long and 22mm dia with complete roses for insulated & non insulated Metal / Wooden Fire Doors.
Cement concrete flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete 40mm thick with 20mm nominal size stone aggregate.
Cement plaster skirting up to 30 cm height with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 18 mm thick.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and Laying Engineered Wooden Flooring conforming to EN 13489 of approved make & approved sample, comprising of 3 layers as specified below, the 3 layers of wood placed with direction of each layer oriented at right angle to the adjacent layer of natural strain, including laying of wooden flooring with approved locking system in a glue less floating manner, including transition profile/end profile as per manufacturer recommendation etc as required, including foam layer, all accessories as required, all complete as per manufacturer specifications, & direction of engineer in charge. Overall Thickness of Plank : 13.5mm. Thickness tolerance ± 0.5mm Top Layer : Oak Natural veneer of minimum 2.5mm thick conforming to EN 13489, pre finished with several layer of UV hardened Acrylic lacquer free from Formaldehyde and solvents. Thickness tolerance ± 0.2mm Core : Minimum 9mm thick wood (Pine wood / Hevea/Spruce).Thickness tolerance ± 0.1mm Base layer : Minimum 2mm thick wood veneer (Pine wood / Hevea/Spruce).Thickness tolerance ± 0.2mm Glue less Locking System : Plank Locking System / Uniclic/ as approved by Engineer In charge, Plank width : 135mm to 210mm, Plank Length : 1800mm to 2420 mm
Providing and fixing solid wood (Oak) skirting of size 15mm thick & 70mm height, using nails / glue of approved make, including the polishing to match the flooring shade, all complete as per direction of enigneer in charge.
Making antiskid grooves of 'V' or 'U' shape size 5mm x 5mm two numbers 50mm centre to centre on treads of steps, landings and similar locations as per the drawings & details.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x1600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x1200 mm (Basic cost of tile is Rs. 860/- per Sqm)
MIRROR Providing and fixing of Mira Gold / Rosa gold / Grey 5mm mirror manufactured industrially by curtain coating process with PU lacquer (50 micron thick), opaque (if viewed against a support wall) conforming to EN 16477 standards for back painted glass , of approved color by Architect/ Client fixed with compatible Neutral Alkoxy based Silicone having Shear Bond Strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 mins compatible for installation of mirror and lacquered glass / Mirror mounting tape MIRROR MOUNTING TAPE - Foam based double sided adhesive tape for instantaneous adhesion, compatible with mirror and lacquered glass having Shear bond strength (Dry, 15 mins) of 250 to 350 kpa) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. The contractor should submit test reports for backpainted glass from manufacturer - High humidity Resistance (conforms to BS EN 1036 1999); Color fastness ISO 105B02 standard & Mechanical Resistance ISO 7784 ( Taber Abrasion test ) ISO 2409 ( Cross Hatch Test ) standard The manufactured backpainted glass should be environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass
Non-PVC Based Graphic Film for Walls, Partitions or Other Solid Non-Porous Substrate Providing and fixing of high quality graphic non-PVC film of thickness not more than 60 Microns. The Adhesive of the film should be a Grey colored pigmented adhesive and it shall stick, without the use of an activator such as solvents or heat. The adhesive of the film should be a pressure activated adhesive providing repositionability and has non-visible air release channels to provide a bubble free application The film should be certified as Green Guard Gold by the Underwriters laboratory. The liner of the Film should be a high-quality paper liner which has a polyethylene coating on both sides to provide excellent lay flatness while converting. The Graphic film should not contain any Heavy metals in its construction and should be compliant with the limits of RoHS Directive 2002/95/EC and its Subsequent amendments. The Film should not contain at greater than 0.1% by weight a Substance of Very High Concern (SVHC) substance identified according to Article 59 of REACH. The film should have fire retardant properties and should have a category of 1 A when tested as per ASTM E 84 standard of flammability testing. The Film should be compliant with EN 13501 for Flame retardancy and should have a minimum Category of “B” under Fire behavior, “ S” under smoke and “D0” for burning. The name of the manufacturer / brand should be clearly displayed on the liner. The film should be printed using a recommended printing platform, applied with a suitable overlaminate film for protection and then installed. The surface preparation and the application should be done using manufacturers recommended procedures and the warranty should be provided by manufacturer directly. Printing on face material must be done with Latex Wide Format Digital Printer with GREENGUARD/ GREENGUARD GOLD Certified Inks or UV Wide Format Digital Printer with GREENGUARD / GREENGUARD GOLD Certified Inks only. Ink Layer should not peel, crack from base substrate used in the intended print application. The entire print construction must be protected with compatible high-quality non-PVC matte overlaminate which is also phthalate and halogen free for use in indoor and outdoor applications. Use of over-laminate is mandatory to protect the print from fading with high conformability to take shape of textured surface of wall. The thickness of the over lamination film should be min 0.05 mm without adhesive. The over lamination film should also comply with the ASTM E 84 standard and meet requirement of Class I (A) and smoke developed rating of less than or equal to 450. Overlaminate should have good chemical resistance property and should resists mild alkalis, mild acids, and salt. It should show excellent resistance to water (does not include immersion) and should resists occasional fuel spills. The edge sealing material should be clear acrylic / alkyd / PU resin or an approved clear tape that will be applied on all the overlap joints of the film and the ends / edges of the film with at least 4 mm footprint covering 2 mm on both the exposed edges.
CARPET FLOORING Providing & Fixing of Flocked textile floor of Nylon 6.6 face fiber or equivalent of approved make with 100% Nylon and completely water proof resilient backing. The flooring should be thickness of 4.3 mm and approximate weight of 1.8 k.g./sqm of roll form. It should achievethe Eurofins Comfort Gold Certifications. The carpet should be completely stain resistant and of a density approx. 80 million fibers/sq.mtr (70 million fiber/sq.yd) in the width of 2 mtr .The floor covering should have Fire Test EN-13501, Appearance Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, with resilient waterproof backing, anti allergic which is certified by British allergy foundation. The carpet should have permanent static contro. The work should be carried out by the authorized installer of the Company in India. Carpet should be laid on zero leveled surface. Carpet should be stick with SR 998 on the floor.
Providing, supply and laying NOX Prime Tile + LVT flooring - 3 mm thickness with 0.50 wear layer (Luxury vinyl flooring of approved design & pattern as per architect's approval & instruction). Type of flooring: Vinyl synthetic floor covering, heterogeneous with EPT Shield (Anti-Bacterial & anti-Fungal), SGBP Certified. Overall thickness: - EN ISO 24346: 3.0 mm. Thickness of wear layer: - ISO 24340: 0.50-0.55 mm. Abrasion Group: EN 660-2- class T. Binder content wear layer: EN ISO 10582 type I (HPD certified). Level of use-EN ISO 10874 class 23/33/42. Dimensional stability:- ISO 23999<0.10% & cooling after exposure to heat<1.0 mm. Safety criteria, Fire resistance EN 13501-I Bfl-s1 (class A) slip resistance: EN 13893 (DS), DIN 51130-R 10 light fastness:- ISO 105- B02>6 Performance impact sound reduction:- EN ISO 10140-3(9 dB), Resistance to Chemicals:- ISO 26987 (No Damage) Warm water:- underfloor heating suitable max. 27 C static load limit: ASTM F970<0.005 in@250 psi min Formaldehyde Group:- EN 717-1(Ei0 VOC Emissions:- IAC Gold certified very low VOC).
Providing and fixing of pre-fabricated sports vinyl flooring of approved make & approved color shade, having resistance to stains & scratches, including cutting the rolls to fit the floor size, providing thermal welding for a seamless floor with uniformity, on a moisture free levelled floor surface using water based adhesive recommended by manufacturer, including all tools and tackles, including under layer foam & door profiles etc , at all levels and heights , all complete, fixing /installation shall be done as per manufacturer recommendations and instructions of the engineer in charge. The flooring shall meet the following technical parameters: Overall Thickness : Minimum 6.2mm Top / Wear Layer thickness : Minimum 0.7mm Weight : Minimum 3.95 Kg/Sqm Performance requirements : Complying to EN 14904 Shock Absorption : > 24%
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( Basic Rate.500 / sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 1200 mm ( Basic Rate.550 / sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800 x 1600 mm ( Basic Rate.550 / sqm)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600 x 1200 mm ( Basic Rate.550/ sqm)
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of pproved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge.
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementations core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and, an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 450 mm Finished Floor Height (FFH)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet black , cherry red ,Elite brown, cat eye or equivalent
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Extra for honed finish in granite as per approval of Engineer-in-charge
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum) including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening "for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 10 m to 13 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 13 m to 16 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 16 m to 19 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 19 m to 22 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 22 m to 25 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 25 m to 28 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 28 m to 31 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 31 m to 34 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 34 m to 37 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 37 m to 40 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 40 m to 43 m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. From 43 m to 46 m
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade : New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Melamine polishing on wood work (one or more coat).
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (Note: - Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete New work (Two or more coats
Providing & fixing of the floor expansion joint system (FP 55)-50mm Floor to Floor Fire Tender Expansion Joints having grooved Flexible High Quality Elastomeric Inserts. The Inserts should be resistant to oils, acids, bitumen and high temperature resistant (- 30°C to + 120°C) for hard weather conditions. Expansion Joint covers and Profile should be Antibacterial and physiologically safe. The system should have solid Aluminum frames in mill finish. The System should be able to withstand a wheel Load of 30 kN for cars and 300kN for Lorries, as per DIN 1991 Specifications. The system is designed for 50 mm Joint size, having a total Movement of 16mm (+/- 8mm) of Joint width. The side Profile should have a MULTI HOLE mounting bracket allowing for secure fixing and flexible anchoring and excellent bonding with given slab surface/masonry/epoxy bedding. For Precise Transitions the factory supplied connection pieces should be used during the installation of the cover system. Provision of Migupren Sealing strip in the Joint System to have 100% Watertight Solution is mandatory requirement as per the manufactured design and as approved by Engineer-In- Charge. The Sealing Strip 100% Watertight solution will be consists of elastic material –Elastomer, Excellent resilience against ozon,Very high long-term heat resistance (up to +90° C), Very high flexibility at low temperatures (up to –40° C), Water pressure up to 0.5 bar, Overall resilience against chemicals, Very good against alkali, diluted acids and saline solutions, Excellent against vapour and Very good resilience against polar solvents like alcohol And ketone.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer in- charge complete. 255 X 19 mm
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc. all complete.
Providing & Fixing of 1 Pair of SS 304 D -Type Handle in Doors at all floor levels with necessary SS 304 screws etc, making neessary rebate in frame/shutter as required , all complete as per direction fo Enigneer in Charge Minimum 22mm dia and 300mm Long of approved make
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 Upto 5 mm depth and 5 mm width
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0 126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (with five years service guarantee).
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and Laying cement concrete using broken AAC blocks 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with approved water proofing compound as per manufacturer's specification, in sunken portions of toilet, kitchen etc. at all levels as per direction of Engineer in Charge.
Supplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane ( bare HDPE film thickness 0.9 mm) conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures.The embrane should be comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weatherproof protective layer. End laps and side laps should be a minimum of 100 mm with Self adhesive tape system .The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. This membrane shall be continued over the vertical surface but terminated minimum 100mm below the top edge of the raft slab/footings and fixed as per recommendation. The HDPE membrane should have the below mentioned techncial properties- 1) Lap Joint(side and end lap) Strength at overlaps 1000N/mm to 15000 N/mm ASTM D 1876 2) Resist hydrostatic pressure of 70 m head of water as per ASTM D5385 3) Puncture Resistance of 900 N to 1000 N as per ASTM E154 4) Peel Adhesion to concrete of 1500 N/m as per ASTM D 903 5) Tensile strength (Bare HDPE membrane) of 25 N/mm2 as per ASTM D412 6) Elongation (Bare HDPE Membrane) 300% to 400% ASTM D 412 7) Low temperature Flexibility -25deg C - Pass as per ASTM D 1970 8) UV Resistance: 45 days) All complete as directed by Engineer-in-charge.
Retaining Wall Water Proofing Providing & applying 2 components, solvent free, liquid applied elastomeric seamless hybrid Polyurea Polyurethane Membrane, using plural component airless spray equipment, to form a minimum system thickness of 1.5 mm in two alternative coats with a total consumption of 1.5-1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Static Crack bridging up to 2mm as per ASTM C 836, Shore A Hardness > 85 ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The coating should pass Dynamic Crack Bridging as per EN 1062-7, Method B for 20,000 cycles at -20-degree temperature. Apply primer coat of epoxy primer by roller/ airless spray guideline and coverage @ 5-6 m2/ltr depends on porosity of concrete. Allow to cure for max 5-6 hours. Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 0.8-1 kg/m2 and allow to come to touch dry condition before application of Hybrid Polyurea Coating. Quotation to include surface preparation, Tie Rod fixing, Fillet making etc. Termination of Membrane at 300mm above G.L.-The waterproofing membrane shall be terminated on the vertical surface. All complete as directed by Engineer-in-charge.
Providing and fixing HDPE protection having dimple height of 6 to 8 mm, as a protection board, over the waterproofing membrane for vertical surface stuck to the membrane by spot bonding method, using synthetic adhesive with butt joints etc. complete. Note-Necessary back filling to be done by the main civil contractor within 2-3 days time progressively after installation of the membrane and protection board , taking care not to cause damage to the waterproofing treatment .
Water Swellable Bar:-All Starter & Construction Joints of raft slab, retaining walls and water retaining structures : Providing and applying water swellable bar at starter & all construction joints, of c/s size of minimum 20mm X 10mm, it shall have resistance to detoriation from salt water, volumetric expansion > 200%, Shore A Hardness > 35, Tensile strength > 1 Mpa, Temperature resistance : (-) 20 to +60 deg C, Water head resistance > 50 m. It shall be fixed to the concrete using a gun grade hydrophilic adhesive / or mechanically fixed by binding wire with steel reinforcement, as recommended by manufacturer. Later post construction, groove cutting of the construction joints 25mm X 25mm size internally / externally, cleaning with compressed air and thereafter filling with Polymer modified cementitious mortar, all as per manufacturers recommendations, etc, complete.
Providing & applying 2 components, solvent free, liquid applied elastomeric seamless hybrid Polyurea Polyurethane Membrane, using plural component airless spray equipment, to form a minimum system thickness of 1.5 mm in two alternative coats with a total consumption of 1.5- 1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Static Crack bridging up to 2mm as per ASTM C 836, Shore A Hardness > 85 ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The coating should pass Dynamic Crack Bridging as per EN 1062-7, Method B for 20,000 cycles at -20-degree temperature. Apply primer coat of epoxy primer by roller/ airless spray guideline and coverage @ 5-6 m2/ltr depends on porosity of concrete. Allow to cure for max 5-6 hours. Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 0.8-1 kg/m2 and allow to come to touch dry condition before application of Hybrid Polyurea Coating. Item to include surface preparation, Fillet making etc.Termination of Membrane at 300mm above Finished Floor Level Separation Layer ( Before Screed) Supplying & laying 200 gsm Geotextile (non woven polyester) over the entire membrane on horizontal area maintaining proper overlaps. All complete as directed by Engineer-in-charge.
Providing and applying 2 coats of acrylic polymer modified cementitious coating having elongation at break 120% as per ASTM D 412 ,Tensile strength 1.0 N/mm2 as per ASTM D 412, 5 Bar resistance to positive water pressure as per EN 12390-8, Adhesion Strength of 1 N/mm2 as per ASTM D 7234, Water Vapor Transmission as per ASTM E96 of 0.7 Perms and Crack bridging ability as per EN 1062-7 up to 2mm. Apply two coats of acrylic cementitious coating @2 Kg per sqm. prepare the mix by adding pre packed powed content to liquid component in the mix ratio (1 part polymer & 1.4 part powder). Provide and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet. Extend coating over the walls up to 300 mm above the Finished Floor Level.the complete height of tank & sprinkle the quartz sand / fine sand over the second and final coat when it is still wet on the vertical wall surface for creating a firm key for plastering to ensure complete waterproofing. Allow the coating to air cure for 5 days before conducting water ponding test for 24 Hrs. Rates to include Surface preparation, Gola Making etc.All complete as directed by Engineer-in-charge.
Food Grade Epoxy( POTABLE) : Providing & applying two coats of approved make Damp gaurd antibacterial antifungal food grade epoxy coating at a consumption of @250/Gms/sq.mtr as per CFTRI 21 CFR 175 - 300 of US - FDA , Water absorption nil as per ASTMC 870:90, adhesion strength of 2.5 N/mm2 as per ASTM D4541:02 applied with an interval of 6-8 hrs between each coat over the cured plastered surface as per manufacturer’s instruction. All complete as directed by Engineer-in-charge.
COAL TAR EPOXY COATING (STP TANKS) Providing & applying 2 coats of approved make Coal Tar Epoxy at a consumption of @500/Gms/sq.mtr with Bonding / adhesion of 1.2 to 1.4 N/mm2 as per ASTM D 4541 ,Water resistance, immersion – 7 days passes as per ASTM D 870-09,Chemical resistance, immersion in dilute acid alkali & salt solutions – 7 days -Passes as per ASTM 868 as per anufacturer's instruction. All complete as directed by Engineer-in-charge.
Providing & applying 2 components, solvent free, liquid applied elastomeric seamless hybrid Polyurea polyurethane Membrane, SS 4500 PUH using plural component airless spray equipment, to form a minimum system thickness of 1.5mm in two alternative coats with a total consumption of 1.5-1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Bond strength > 2 Mpa as per ASTM D 7234, Crack bridging up to 2mm as per ASTM C 836, Shore A Hardness > 85 as per ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The membrane shall be applied on horizontal surfaces and on verticals up to 300mm height above the FFL / Soil fill level, self-curing for 2 days, there after ponding with water for 2 days to test the water tightness. Apply primer coat of Cipoxy 16D by roller/ airless spray @ coverage of 250 -400 gram/m2 depends on porosity of concrete. Allow to cure for max 5-6 hours. Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 1.5-2.5 kg/m2 and allow to come to touch dry condition.
Termination of Membrane at 300 mm on vertical The waterproofing membrane shall be terminated on the vertical surface. The membrane shall be terminated either by creating a "U" shaped groove of approx. 10 mm x 10 mm size within the RCC retaining wall, tucking the membrane within the groove, followed by sealing the groove with polyurethane sealant/ epoxy mortar or alternatively the membrane shall be terminated by fixing a metal termination bar on the vertical surface, with butyl sealant between the metal plate and wall surface and sealed on top with P.U. sealant etc. complete
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:, Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: , Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers., Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight., Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. , The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places., Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accredited by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories, "Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04, testing method for a range of testing limit 1 to 200 mVhr" , Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml, Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 10f the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm / sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.“For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
SKY LIGHT SHEET Supply & Installation of roof with co-extruded, UV protected, multi-layered / multi-cell connectible modular polycarbonate panel system. The system is consisting of 18 mm thick standing seam panel with X-cell truss bracing design structure for better strength and flexibility in seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be fixed on Purlins of MS structure (to be paid Separately) with wide trapezoidal SS fastener/cleat ( in SS-304 in 1mm thick) with top holding of 80mm on standing seam, fixed with purlins with 3 numbers of self-drilling screws to ensure a pull-out load of min. 7000 N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. The entire fixing mechanism shall be covered with a continuous U/2, interlocking connectible connectors with grip lock anti pop double tooth locking mechanism running lengthwise at both sides of the panel. Each panel shall be flux solo opaque type with opaque and clear combination of louvers inside the single panel i.e. with transparent body and opaque layers in between the layers creating 'Light Duct' for better ambience & increased shading. Panels with more layers will be preferred for better insulation and improved shading coefficient. U value of such panel shall not be more than 1.9 Watt/m2K as per EN ISO 10077-2:2018 and respective third-Party test certificate shall be produced before procurement. The width of the panels shall not be less than 1000 mm. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D2244 (standard D65 illuminant, CIELAB) not more than 1 unit when tested on a sample exposed to UV/weathering test for 2500 Hours as per ASTM D4329. The panel shall be with additional sealing / breathing tape, Aluminum U profile for ends, screws etc. as per standard accessories as required. Panel shall be fixed conforming to the detailed methodology & guideline as per the manufacturer. Trained and factory authorized labor shall be used with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge.
OUTER FAÇADE LOUVERS AeroScreen 600 – AS 600 Fixed Louvers System:Supply and fixing of Aeroscreen 600 mm Plain/Perforated fixed type louver system consisting of single skin high corrosion resistant aluminium alloy of Al-Mn05-Mg05 (ENAW 3105) of 0.90 mm thick, plain and customized perforation. The Aeroscreen louver is fixed on aluminium extruded tube with aluminium extruded wing shaped brackets of Alloy Al-Mg-Si 0.5 (ENAW 6063-T6) with fixing system accessories which shall be manufactured on high speed, high precision roll forming machine with ARKU SIX Hi configuration roller levelling process. The customized perforation pattern dully approved shall be done on CAD/ CAM auto index to achieve flatness of the panel without any undulation.The maximum unsupported length of louver fin shall be 5700mm and required length shall be determined based on structural design requirement by considering the relevant wind load, dead load and deflection criteria. The module and angle of fin for the fixed system shall be as per the approved drawing.The Aeroscreen full louver fins shall be fixed at the both ends on the concrete slab. MS steel sub-structure and anchor fasteners required to fix the fins. Visible area of the fin can be covered using back skin of 0.7mm thick aluminium if required as per client’s requirement.The Aeroscreen fin shall be coated on visible side with The Aeroscreen fin shall be coated on visible side (front and back skin) with exterior architectural super durable polyester based coil coating with minimum dry film thickness of 20 micron Aluminium panels shall be chromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer finish, the other side (Inner side) with a primer coat and skin coat on a Continuous paint line. The coils to go through 4 stages of pre-treatment, three times oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability. The coils to be painted on both sides after degreasing. Inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and topcoat of approved colour of 15 microns. Central assembly and wing shaped brackets and customised brackets for half fins are anodised with minimum 10mircon. Manufacturer should have in house testing lab and powder coating line with Nano technology and Catalytic Converter Oven.The panels shall be manufactured on high precision & high-speed roll forming machine to control product dimensional tolerance within limits and achieve consistent quality product.Quality Management System: The Company should have own Manufacturing Plant with QC Laboratory.ISO Certification - ISO 9001: 2015 Quality Management System Certification shall be mandatory.Sustainability: The product shall meet the Seismic Standard IS 1893: 2016 Part 1, Zone 5 (Five) tested by a specialized and reputed Indian testing Institution.The complete cost is including of MS substructure and anchor fasteners.
Design, supply & installation of curved fin shape bamboo panels of width 600 mm & lenghth 4200 mm installed as per manufacturer system deisgn including substructure/secondary MS frame structure. The element should be made up of engineered bamboo layer with reinforced aluminium elements in order to achive the bespoke design intent of the architect. The element should be installed as per the design intent with cutmoized postions and centre to center spacing 750 mm as per design scheme. The element should withstand the desired windload requirements, external environment conditions. The company should have an experience of doing a large scale bespoke bamboo project.
Design, supply & installation of module consist of 75 mm diameter round tubes at 175 mm center to center with box frame, the module dimension of 4200 mm height & 2100 mm width as per manufacturer system deisgn. The element should be made up of engineered bamboo layer with reinforced aluminium elements in order to achive the bespoke design intent of the architect. The element should be installed as per the design intent with cutmoized postions as per design scheme. The element should withstand the desired windload requirements, external environment conditions.
Metal baffle- Providing and fixing customised perforation torsion spring Plank Ceiling System of approved finish comprising of Plank of 600mm wide and 1200mm long manufactured out of 1.2 mm thick Aluminium Alloy 3105 perforated 1.5mm dia With 22% open area. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing process. Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Planks will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank shall be Polyester powder coated in wood finish colour. All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification. The Metal ceiling is Tested for Seismic Zone V compliance as per IS 1893 part 1-2016”Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length.Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on centre maximum. Suspension System: As per manufacturer standard considering type of plenum and its height.Paint finish – The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system and cured with gas catalytic technology.Acoustic Felt (Optional): Non-woven felt made of glass-reinforced fibre glued over the perforationfor sound absorption. NRC- 0.7.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Acoustical false ceiling Supply and installation of Strand pinewood fiber Spots MP3,Square edge,factory made composite panels with finish panels of with 3mm circular perforations @ 16mm c/c, melamine finish, 1-test FR grade, of size 595x595x5mm with backing of Strand fiber board as backer of density 400 kg /m3, square edge magnesite bonded pinewood 2mm wide fibre core tiles of size 595x595x10mm, which is suspended using 0.3mm thick Skelet Trelis T24 metal grid system. " Skelet Trelis T24 ceiling grid system, of 600x600mm module includes Skelet WA24W30 sectional thickness 0.4mm, with equal flanges of 24mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centres. Then suspend the Skelet MT24W36, sectional thickness 0.3mm with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of Anchor Bolt, Soffit Cleat and Suspension Rod with Levelling Clip at 1200mm centres.Extra support to be added near jointing of two MT24 so that end cantilever should not be more than 150mm. Skelet CT24W12, sectional thickness 0.3mm with flange width 24mm, height 32mm and length 1200mm is interlocked into the pre-cut slots in the Main T24 at 600mm centres in the perpendicular direction to the Main T24. Finally Skelet CT24W06, sectional thickness 0.3mm, with flange width 24mm, height 32mm and length 600mm are interlocked into the precut slots in the CT24W12 in direction parallel to the Main T24 to result in 600x600mm module. Strand Spots MP3 of size 595x595x15mm shall be placed into the grid size of 600x600mm." The system is backlined with acoustical infill SynthPF 10x25. Technical Parameters of finish product "• Fire (Class) – 1 & P, • Acoustics – NRC upto 0.85 (For system,For E300*Mounting), • Climate (°C, RH) – 50, 70 • Light (%) – Colour Dependant, • Green (VoC, RC %) – E1, 25", Including material and installation cost all complete
Providing and fixing in true horizontal level Open cell Aluminium false ceiling system of approved make and shade, comprising of main and secondary blades of width 15 mm and height 37-38mm made of 0.35-0.40mm thick aluminium sheet, cross connected to form 100x100mm square cells to make percentage open are of 72-83%, and laid on the 600mm x 600mm grid system with web height of 38mm per manufacturer's specifications and approved by engineer in charge and shall have sufficient loaded carrying capacity including any additional support members wherever required for light fixtures, AC diffusers, etc. The false ceiling system shall be a noncombustible system. Rate quoted to include all cut outs required for light fixtures, smoke detectors and other services cut outs, all complete as per drawings, manufacturer's specifications and direction of Engineer in Charge. Finished area of false ceiling in horizontal plane and excluding the openings made for 600mm x 600mm size or higher light fittings, diffusers etc shall only be measured for payment.
VENNERED WOODEN CEILING Providing and laying custom made wooden melamine polish veneer false ceiling made of 4 mm thick teak veneer ply of in approved of approved shade pasted over 12 mm marine plywood of using chemical adhesive including forming grooves as shown with system supported in painted structural steel frame work of planum and vertical hangers angles 25x50x5 mm duly fixed to ceiling using expansion bolts. Lockable cut outs/trap doors and frames shall be provided in false ceilings as per approved design of services.
Drilling or Core cutting, horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to the designated location at ground floor / basement of the building, all complete at all heights & depths as specified and directed up to 32 mm diameter for a depth / length upto 250 mm
Drilling or Core cutting, horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to the designated location at ground floor / basement of the building, all complete at all heights & depths as specified and directed Diameters above 32 mm but up to 100 mm for a depth / length upto 250 mm
Drilling or Core cutting, horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to the designated location at ground floor / basement of the building, all complete at all heights & depths as specified and directed Diameters above 100 mm for a depth / length upto 250 mm
Providing and making Control Joint, cutting groove 4x40mm, filling groove with sand upto 20mm depth, filling groove 4x20mm with epoxy, making tap etc all complete as directed by engineer-in-charge.
Supplying and installing roller blinds of approved make & approved shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of 32mm -38mmO.D or 47mm O.D for motorized blinds, a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch of minimum 6.5mm, plastic Ball Chain, and powder coated atomized steel installation brackets. The clutch mechanism comprises of a plastic beaded chain and carbon steel spring wrapped by means of a high strength fiber glass reinforced polyester assembly to transmit motion from driving to driven members. The installation brackets shall facilitate overhead, side or face mounting with clutch assembly on either end of the roller. Idler shall consist of a centre shaft and outside sleeve which provide bearing surface for roller tube and rotate freely on centre shaft for smooth and quiet operation ( Chain to be provided for Manual blinds only ) Blackout fabric having following specifications: Composition : Fiberglass with PVC coated or equivalent. washable Openness factor : opaque Weight : min 400 g/sqm Thickness : min 0.36mm Fire Classification : NFPA-701 or equivalent Fastness to light : 5-6 or higher Indoor Air Quality : GreenGuard / Eco-Codice Certified.
Supplying and installing roller blinds of approved make & approved shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of 32mm -38mmO.D or 47mm O.D for motorized blinds, a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch of minimum 6.5mm, plastic Ball Chain, and powder coated atomized steel installation brackets. The clutch mechanism comprises of a plastic beaded chain and carbon steel spring wrapped by means of a high strength fiber glass reinforced polyester assembly to transmit motion from driving to driven members. The installation brackets shall facilitate overhead, side or face mounting with clutch assembly on either end of the roller. Idler shall consist of a centre shaft and outside sleeve which provide bearing surface for roller tube and rotate freely on centre shaft for smooth and quiet operation ( Chain to be provided for Manual blinds only ) Screen fabric having following specifications: Composition : 25% (Max) Polyester + 75% (Min) PVC Openness factor : Approx 5% Thickness : 0.56 ± 5% mm Weight : 445 ± 5% g/m2 Fire resistance : Class A NFPA 701 or equivalent Color fastness : 6-7/8 or higher or equivalent Health/Safety certificate : Oekotex /GreenGuard
Supplying and installing roller blinds of approved make & approved shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of 32mm -38mmO.D or 47mm O.D for motorized blinds, a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch of minimum 6.5mm, plastic Ball Chain, and powder coated atomized steel installation brackets. The clutch mechanism comprises of a plastic beaded chain and carbon steel spring wrapped by means of a high strength fiber glass reinforced polyester assembly to transmit motion from driving to driven members. The installation brackets shall facilitate overhead, side or face mounting with clutch assembly on either end of the roller. Idler shall consist of a centre shaft and outside sleeve which provide bearing surface for roller tube and rotate freely on centre shaft for smooth and quiet operation ( Chain to be provided for Manual blinds only ) Extra For Supply, Installation, Testing & Commissioning of remote operated Motor of approved make as operating system to lift blinds to up & down with multi channel remote operate motor, compatible to be placed in roller tube. The item includes all fittings, accessories, brackets, screws, tube of appropriate size, anchor fasteners, making electrical connections, all complete as per drawings, tender specifications, relevant standards and direction of Engineer in charge , having following specifications : Nominal Torque(Nm) : 3 to 6 Nominal Speed(rpm) : 20 to 30 Rated Voltage(V) : 230, 50Hz Rated Power Consumption(W) : 90/120 Running Time Before Thermal Cut Off(min) : 4 Average Running Noise(dbA) : < 42dB IP Protection : Minimum IP 31
Supplying and installing roller blinds of approved make & approved shade at all heights and location and required width and comprising of approved shade and quality fabric, 1 mm thick anodized extruded Aluminium alloy roller tube of 32mm -38mmO.D or 47mm O.D for motorized blinds, a bidirectional operating Clutch mechanism designed for adjustment-free, slippage-free, crash proof smooth operation for all heights, high strength fiber glass reinforced polyester idler, powder coated steel Insert type brackets fitted with roller tube, round bottom rail, control unit engrooved with a Ball Pitch of minimum 6.5mm, plastic Ball Chain, and powder coated atomized steel installation brackets. The clutch mechanism comprises of a plastic beaded chain and carbon steel spring wrapped by means of a high strength fiber glass reinforced polyester assembly to transmit motion from driving to driven members. The installation brackets shall facilitate overhead, side or face mounting with clutch assembly on either end of the roller. Idler shall consist of a centre shaft and outside sleeve which provide bearing surface for roller tube and rotate freely on centre shaft for smooth and quiet operation ( Chain to be provided for Manual blinds only ) Supplying remote control of approved make and model (for each room with motorized blinds) capable of providing individual as well as group Control (upto 16 channels) for the motors of the roller blind mentioned in above item, including batteries all complete, as per direction of engineer in charge.
Lift Number Signage Providing & Fixing of Signage to be made up of 1.2mm thick SS Pvd Sheet in approved color & finish duly pasted upon 010 3mm thick acrylic sheet, including fixing of Signage on the existing surface ( wall / glass / paritition) with the help of industrial glue/double sided tape at all floor levels and heights , all complete as per drawings and direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge.
Lift Lobby Announcer Sign conference room, cafe, play & plug area Providing & Fixing of Signage to be made in two layers, layer 1 is a 8mm thick acrylic sheet base duly PU painted in approved color & finish; layer 2 is a 5mm acrylic sheet in approved color & finish pasted upon layer 1, the content to be directly UV printed on it, inlcuding fixing of signage on existing surface ( wall / glass / parition etc) with the help of industrial glue/double sided tape at all floor levels and heights, all complete, as per drawings & direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge.
Floor Number sign Opp. Lift opening Providing and Fixing of signage to be made in two layers - layer 1 is a base made up of 25mm thick WPC sheet duly PU painted (as per approved color & finish); layer 2 is a 5mm acrylic sheet (as per approved color & finish) pasted upon layer 1 , the signage base to be fixed on existing surface with the help of pvc plug & self threaded screws (to be fixed beneath the letter), at all floor levels & all all heights, all complete as per drawings and direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge.
Floor Directory Sign Providing and fixing of Signage to be made with 10mm Aluminium Profile 6060 & 3mm acrylic sheet (as per approved color & finish ), acrylic sheet to be fixed within the frame; Content to be UV printed directly on the acrylic sheet, including fixing of sigange on the existing wall with the help of pvc plugs & screws, at all floor levels & all all heights, all complete as per drawings and direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge.
Service Rooms Signage Providing & Fixing of signage to be made up with 5mm thick Acrylic Sheet in approved color & finish, the content to be directly UV printed on it, including fixing of Signage on the existing surface ( wall / glass / partition/ door shutter ) with the help of industrial glue/double sided tape, at all floor levels & all all heights, all complete as per drawings and direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge.
External Signage on Facade with IT TECHNOPARK BUILDING Providing & Fixing of Signage to be made in GSB detail with 3M P2 Flex (white) in base & 3M Vinyl 3630 series CNC cut (as per approved color), and to be pasted upon the white flex and content to be pinned out, including the signage supporting structure with M.S double frame made up with 25mmx25mm 14 SWG with depth of 150mm, G.I sheet to be fixed on the back side of Aluminium sheet (as per approved color & finish), base frame shall be fixed using approved make anchor fasteners, inlcuding fixing of signage at the roof level on existing externla wall with the help of M.S angles clamps & chemical fasteners in such a way that no fixing detail is visible, including illumination/lit with the help of OSRAM/ GE/ CREE/ NICHIA/ OSRAM approved equivalent led modules of IP 66 & power adapters. all complete as per drawings and direction of engineer in charge. All the materials shall be approved of make. Contractor to submit the shop drawings, samples and get the same approved from Engineer In Charge. . The scaffolding shall be paid under respective item. Approx size : 32000mmx1750mm
Providing and application of PU concrete from approved vender an environmental friendly low VOC (Based on USEPA Method 24 Section 11.2.2 & ASTM D2369-98),chemical resistant, antimicrobial, polyurethane resin floor system with smooth matt colored finish. PU Self leveling incorporates Polygiene® - a performance based antimicrobial additive which inhibits the growth of bacteria, fungi,moulds and mildew of specified thickeness of PU Concrete having operations of grinding/Scarifying & cleaning the surface thoroughly & removing laitance completely, cutting grooves in 4x4 panel in order to lock the PU flooring to mother slab,refurbishing the floor by filling the pitting and hole on the floor by doing scratch coat of 1 mm and applying PU Self leveling in 2 mm thickness in approved color complete in accordance with the manufacturer's instructions and recommendations.
Providing, fixing, testing and commissioning of white vitreous china wall-hung European water closet (EWC) with dual flush concealed cistern (4/2 Litre flush) conforming to GRIHA 5-star water efficiency standards (≤6 L full flush, ≤3 L half flush). The W.C. shall be fixed on concealed carrier frame with minimum 400 kg load-bearing capacity, powder-coated or stainless steel frame, and include all CP brass nuts, bolts, washers, fixing arrangements. Soft-close seat and cover in UF or polypropylene with C.P. hinges and buffers. The installation shall include cutting/making good walls/floors as required. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Plumbing works Providing, fixing, testing and commissioning of white vitreous china wall-hung European W.C. with dual flush concealed cistern (4/2 litres), conforming to GRIHA 5-star rating (≤6 L full flush, ≤3 L half flush). The W.C. shall be installed on a heavy-duty concealed wall carrier frame of minimum 400 kg load-bearing capacity with integrated cistern and flush actuator plate, including CP bolts, nuts, brass screws, rubber buffers, and all fixing hardware. Soft-close seat cover in UF or polypropylene with C.P. hinges and buffers. Installation to include cutting/making good walls, floors, and tiles wherever necessary. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing premium Health Faucet set with brass body, 1.2 m long SS 304 double-lock flexible hose, wall hook, and CP flange, complete with mounting accessories. The product shall be GRIHA 5-star compliant (≤6 LPM @ 3 bar), conforming to CPHEEO and IS standards. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing, fixing, testing & commissioning of chrome-plated brass pillar taps with optional sensor, pressmatic, or manual operation, conforming to GRIHA 5-star water efficiency rating (≤6 LPM @ 3 bar), suitable for washbasin applications with premium finishes.
Sensor-Operated Pillar Taps (Touch-Free AC/DC Type) Providing, fixing, testing & commissioning of sensor-based pillar taps made of chrome-plated brass, suitable for automatic hands-free operation using infrared detection. Tap shall operate on AC and/or battery power, with built-in solenoid valve, control box, and aerator limiting flow to ≤6 LPM at 3 bar pressure, conforming to GRIHA 5-star water efficiency rating. Finish: Chrome-plated or premium finish. Make : Jaguar/Kohler/Grohe/Roca/Queo
Manual Quarter-Turn Pillar Taps with Aerator Providing, fixing, testing & commissioning of manually operated pillar taps made of chrome-plated brass with quarter-turn ceramic cartridge and integrated foam flow aerator. Tap shall be suitable for low-demand hand wash areas, ensuring flow ≤6 LPM at 3 bar as per GRIHA 5-star rating. Finish: Chrome-plated, brushed gold, or matte black. Make : Jaguar/Kohler/Grohe/Roca/Queo
Pressmatic Self-Closing Pillar Taps Providing, fixing, testing & commissioning of pressmatic (push-type) pillar taps made of chrome-plated brass with internal timed shut-off mechanism, suitable for high-usage areas such as public washbasins or pantry counters. The tap shall self-close after a pre-set duration, and flow shall be restricted to ≤6 LPM at 3 bar pressure (GRIHA 5-star compliant). Finish: Chrome-plated or equivalent anti-corrosive premium finish. Make : Jaguar/Kohler/Grohe/Roca/Queo
Providing, supplying, installation, testing & commissioning of semi-recessed (semi-countertop) white vitreous china wash basin of approved quality and design, suitable for countertop integration. The basin shall be complete with 32 mm C.P. brass waste coupling (full-threaded), C.P. brass cast bottle trap with wall pipe, C.P. brass flange, and rubber adaptor. The installation shall include sealing the joint between the basin and counter using approved polysulphide sealant, and cutting/making good walls and surfaces as required, all as per manufacturer’s recommendations. The basin shall be compatible with low-flow tap fixtures conforming to GRIHA 5-star compliance (≤6 LPM @ 3 bar). Approved Makes: Jaquar, Kohler, Roca, Grohe, Queo
Providing, supplying, installation, testing & commissioning of premium quality white vitreous china under-counter and over-counter wash basins, complete with CP brass waste, bottle trap, and installation accessories, compatible with low-flow tap fixtures conforming to GRIHA 5-star rating (≤6 LPM @ 3 bar). The basins shall be installed as per manufacturer’s recommendation using approved quality C.P. brass fittings and sealed with polysulphide sealant. Premium models with glossy, matte, or textured finishes are acceptable if offered by approved makes. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo recommendation.
Over-Counter Wash Basins (Designer Feature Basins) Providing, supplying, installation, testing & commissioning of over-counter white vitreous china designer wash basin with 32 mm C.P. brass waste coupling, C.P. brass cast bottle trap with wall pipe, rubber adaptor, and CP flange. Shall be fixed on counter with polysulphide sealant and suitable for use with low-flow tap fixtures (≤6 LPM @ 3 bar, GRIHA 5-star compliant). Finish: Glossy white or approved premium finish from approved brands
Under-Counter Wash Basins (Flush-Mounted for Seamless Countertops) Providing, supplying, installation, testing & commissioning of under-counter white vitreous china wash basin with 32 mm C.P. brass waste coupling (full-threaded), C.P. brass cast bottle trap with wall pipe, rubber adaptor, and C.P. flange. Basin shall be installed flush to counter using polysulphide sealant and be compatible with low-flow tap fixtures (≤6 LPM @ 3 bar, GRIHA 5-star compliant). Finish: Glossy or matte finish from approved makes
Providing and fixing CP brass soap dish holder of approved design, minimum overall dimensions approx. 135 mm x 100 mm x 75 mm, with concealed wall-mounting arrangement. The soap dish shall be of corrosion-resistant chrome-plated brass or equivalent premium finish (e.g., matte black, brushed gold) as per approved bathroom interior design scheme. The item shall be installed as per manufacturer’s recommendations with all accessories required for firm installation. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing white vitreous china sensor-operated urinal: Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing white vitreous china sensor-operated urinal with rear water inlet and battery-powered infrared sensor with dual flushing (pre-flush 250 ml, post-flush 500 ml), total consumption ≤ 1 litre per use, conforming to GRIHA 5-star water efficiency standards. Urinal shall be wall-mounted using concealed brackets as per manufacturer’s specifications, and include all necessary fixing hardware. Sensor system shall have minimum 3-year battery life, factory-set sensing range (adjustable if required), and IP65-rated housing for moisture protection.
Providing and fixing wall-mounted coat hook made of chrome-plated brass or stainless steel with concealed fixing system, suitable for installation in toilet cubicles and behind doors. The hook shall be of minimalist design, anti-corrosive, and matching the approved design intent of other CP accessories. Premium finishes such as matte black or brushed gold may be used in designer washrooms, subject to approval. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing high-speed, wall-mounted, touch-free hand dryer with vandal-resistant ABS or stainless steel outer body, suitable for premium hygienic restrooms. The unit shall operate via infrared sensor, include a HEPA filter capable of removing ≥99.97% of airborne particles (PM 0.3 and above), and ensure a drying time not exceeding 12 seconds. The hand dryer shall be equipped with heater ON/OFF functionality for summer/winter control, time-delay auto cut-off, overheat protection, and shall operate at a noise level not exceeding 65 dB(A). Each hand dryer shall be supplied with two additional spare HEPA filters, neatly packed and clearly labelled with model compatibility, for future maintenance use. The unit shall be installed with concealed mounting brackets, tamper-proof locking covers, plug top with wiring cable, and all other accessories required for complete functional installation. Approved Makes: Dyson (Airblade V), Mitsubishi (Jet Towel), Toto (Clean Dry), Kohler (Premium Sensor Dryer), Euronics (Jet Sensor Series) Finish: White, matte grey, brushed stainless steel, or as approved by Technopark
Providing and fixing single-lever sink mixer made of CP brass with swivel spout, suitable for deck-mounted installation on kitchen or pantry sinks. The mixer shall include dual hot and cold inlets, operate through a ceramic disc cartridge, and incorporate a foam flow aerator limiting discharge to ≤6 LPM at 3 bar pressure to comply with GRIHA 5-star rating. The item shall be complete with all fixing hardware and shall be available in chrome-plated finish or equivalent premium finishes (matte black, brushed nickel, etc.) as per architectural design intent. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing 32 mm size bottle trap made of chrome-plated brass with adjustable telescopic wall pipe, C.P. brass wall flange, and rubber adaptor for waste connection to concealed drain point. The bottle trap shall have a minimum wall clearance of 75 mm and be compatible with under-counter, over-counter, and wall-hung washbasins. The trap shall include an anti-splash design and comply with IS: 14775 / international equivalent. Designer finishes (chrome, matte black, brushed gold) may be accepted as per interior design scheme. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing toilet paper holder made of chrome-plated brass or stainless steel, with concealed wall-mounting arrangement and anti-corrosive finish. The item shall be installed firmly as per manufacturer’s guidelines and matched with the approved CP accessory series in finish and design. Premium finishes (e.g., brushed gold, matte black, gunmetal grey) shall be accepted as per interior design intent. Approved Makes: Jaquar, Kohler, Grohe, Roca, Queo
Providing and fixing 6 mm thick machine-polished edge mirror made from high-quality silvered float glass, shaped and cut to approved design intent. The mirror shall be mounted over 12 mm BWR grade marine plywood with water-resistant back painting and anti-fungal coating. Mirror shall be fixed using high-strength adhesive and secured with stainless steel concealed mirror clips, including edge sealing as per manufacturer’s recommendation. Safety film (shatter-resistant) shall be laminated on the rear surface where required. All exposed edges to be machine-polished. Installation to be completed as per Technopark's drawing and interior design specifications. Finish/Shape: Rectangular, round, or custom per approved detail
Providing and fixing CP brass angle valve (15mm nominal bore) with ½" BSP threaded inlet/outlet, heavy-duty construction suitable for pressure up to 10 bar, with wall flange, suitable for basin mixer and geyser points. Valve shall be of approved make as per approved list and installed as per manufacturer's instructions and direction of Engineer-in-Charge. Make: Jaquar / Kohler / Roca / Queo / Euronics
Providing and fixing height-adjustable Lift-up Arm Support, 730 mm length with 240 mm height adjustment, in white or anthracite finish (Product Code: PRPR37047 or equivalent), made of epoxy-coated aluminum/stainless steel with support load capacity not less than 150 kg, suitable for persons with reduced mobility. To be installed on a structurally sound rear wall at designated toilet locations, in compliance with ISO 21542:2011 and NBC 2016 accessibility standards, using corrosion-resistant fixing hardware as per manufacturer’s instructions and as directed by Engineer-in-Charge. Make: Prosafe / Pressalit / Profilo Smart (subject to prior approval).
Providing and fixing Stainless Steel Grab Bar, 900 mm in length and 32 mm diameter, made from SS 304 grade with matt/brushed finish, installed on rear wall of accessible WCs as per NBC 2016 and ISO 21542:2011 standards. The grab bar shall be capable of withstanding a minimum load of 150 kg, fixed using stainless steel anchor bolts or corrosion-resistant fasteners (minimum 3-point fixing) on a structurally sound wall. Installation shall be done as per manufacturer's instructions and as directed by the Engineer-in-Charge. Make: Jaquar / Prosafe Living (subject to approval).
Providing and fixing Stainless Steel Grab Bar, 600 mm long and 32 mm in diameter, made from SS 304 grade with matt/brushed finish, installed as per NBC 2016 and ISO 21542:2011 accessibility standards. The grab bar shall be capable of withstanding a minimum load of 150 kg and shall be fixed using corrosion-resistant stainless steel anchor bolts (minimum 2-point fixing) on a structurally sound wall. Installation shall follow manufacturer’s instructions and direction of Engineer-in-Charge. Make: Jaquar / Prosafe Living
Providing and fixing of manually height-adjustable wash basin bracket, 240 mm vertical adjustment range (Product Code: PRPR4580 or equivalent), suitable for accessible washroom applications. The bracket shall be made of powder-coated aluminum or stainless steel, capable of safely supporting a wall-hung ceramic basin with a minimum load of 150 kg. Installation shall comply with NBC 2016 and ISO 21542:2011 accessibility guidelines, and be carried out on a load-bearing RCC/masonry wall using corrosion-resistant fasteners as per manufacturer’s instructions and as directed by the Engineer-in-Charge. Make: Prosafe / Pressalit / Profilo Smart
Providing and fixing of flexible feed and waste plumbing system with 700 mm long flexible waste pipe (PRPR 2065 or equivalent), suitable for use with height-adjustable wash basins. The pipe shall be made of high-quality non-corrosive, chemical-resistant material (such as EPDM or PP), with a smooth bore and minimum 32 mm inner diameter, and capable of accommodating vertical adjustments without disconnection. Installation shall comply with EN 274/IS standards for sanitary drainage and as per manufacturer’s instructions and direction of Engineer-in-Charge. Make: Prosafe / Pressalit / Profilo Smart
Providing and fixing Stainless Steel L-Type Grab Bar, 600 mm (horizontal) x 600 mm (vertical) with 32 mm diameter, made of SS 304 grade, with matt/brushed finish, fixed adjacent to WC (on rear and side wall or side wall alone as per layout) to support persons with reduced mobility. The grab bar shall comply with NBC 2016 and ISO 21542:2011 standards, and shall be capable of withstanding a load of at least 150 kg. It shall be installed using corrosion-resistant anchor bolts on structurally sound RCC/masonry surfaces as per manufacturer's installation instructions and as directed by the Engineer-in-Charge. Make: Jaquar / Prosafe Living
Providing and fixing 45 cm long flexible connection pipe (unplasticized or EPDM inner core) with brass union fittings on both ends, 15 mm nominal bore (½” BSP thread), suitable for hot and cold water supply connections to basin mixers and flushing systems. The pipe shall be pressure tested for 10 bar and temperature-rated up to 80°C, and installed with proper gaskets and tools as per manufacturer's guidelines and as directed by Engineer-in-Charge. Make: To be approved by Engineer-in-Charge; must comply with relevant IS/ISO standards.
Providing and fixing 15 mm nominal bore C.P. brass bib cock conforming to IS:8931, pressure tested for 10 bar, with male threaded BSP outlet and integral wall flange, suitable for wall mounting. Bib cock shall be of approved make listed under CP fittings, with ISI marking and chrome-plated finish. Installation shall be as per manufacturer’s instructions and as directed by Engineer-in-Charge. Make: Jaquar / Kohler / Roca / Queo / Euronics
Providing and fixing 18 mm thick machine-cut, mirror-polished granite stone slab of size 750 mm x 500 mm for urinal partitions, made from hard, sound, and uniform-coloured granite of approved shade and quality. Slab shall have all edges rounded to 5 mm radius, corners smoothened, and surface polished to mirror finish. The slab shall be fixed vertically by cutting a chase in the wall using chase cutter and embedded with epoxy-based grout or 1:2:4 cement concrete mix using 6 mm nominal graded aggregate. All joints shall be finished smooth and sealed with non-staining, anti-fungal silicone sealant. Work shall be carried out as per manufacturer’s guidelines and as directed by the Engineer-in-Charge.
Providing and fixing 100 mm x 100 mm floor trap of uPVC SWR type, self-cleansing design with a minimum 50 mm water seal, conforming to IS 13592 for pipe and IS 14735 for fittings. The trap shall be of heavy-duty uPVC construction, fitted with a screwed-down stainless steel or chrome-plated brass grating (hinged type optional). The floor trap shall be solvent-welded to a short length of uPVC pipe and then connected leak-proof to the PPR triple-layer soil/waste pipe using a suitable transition coupling (such as mechanical sleeve coupling or a rubber-sealed adaptor). The item includes: All necessary cutting/chasing in floor or wall and reinstatement using 1:3 cement mortar, Ensuring proper slope towards the trap, Leak-proof and mechanically stable transition between SWR and PPR systems. All fittings shall be from approved makes conforming to IS standards.
Providing and fixing Stainless Steel kitchen sink of ISI 304 grade (18/8), conforming to IS:13983, including C.I. brackets for wall mounting, stainless steel waste plug of 40 mm dia, painting of brackets and fittings with anti-corrosive paint, and including all necessary cutting and making good the wall and floor wherever required, complete in all respects as per manufacturer’s specifications and direction of the Engineer-in-Charge. Make: Jayna / Nirali / Anupam / Neelkanth
Kitchen sink with drain board, size 510 x 1040 mm, bowl depth 250 mm
Providing, fixing, testing, and commissioning of NSF-certified 3-layer PPR (Polypropylene Random Copolymer, Type 3) pipes conforming to IS 15801:2008, IS 17484, and DIN 8077/8078 standards, with UV-stabilized, anti-microbial outer layer and carbon-black-infused middle layer for external application durability. Pipes shall have a minimum PN 10 pressure rating, with socket fusion welding for all joints to ensure a monolithic, leak-proof system suitable for rainwater down-take applications in high-rise buildings (up to 12 levels, including basement). The scope includes supply and installation of factory-moulded, manufacturer-matched triple-layer PPR fittings such as 45°/90° bends, equal/reducing tees, reducers, cleanouts, end caps, and roof connection adaptors. All accessories shall conform to the same performance class and pressure rating. No field-fabricated fittings shall be allowed. Pipes shall be supported using UV-resistant, rubber-lined GI clamps at a maximum spacing of 1.0 m (vertical) and 0.75 m (horizontal), mounted to structural members with appropriate fasteners and inserts. For thermal expansion management, compensators or expansion loops shall be provided as per the manufacturer's guidelines. Connections from roof gutter outlets to the PPR down-take pipe shall be completed using certified adaptors, with joints sealed as per the manufacturer's recommendations to ensure zero ingress at interface points. All installed pipe sections shall be subjected to hydrostatic pressure testing at 1.5 times the working pressure for 2 hours, with joints exposed for inspection. Post-installation cleaning, tagging, and commissioning shall be executed per project quality procedures. A compliance certificate for NSF 61/14, IS 15801, and DIN 8077/8078 shall be submitted for the supplied batch. All installation shall comply with NBC and IS plumbing codes, ensuring rainwater discharge is effective for the entire building height.
Providing, fixing, testing, and commissioning of triple-layer polypropylene random copolymer (PPR) pipes for soil, waste, and vent (SWV) applications, conforming to IS 15801:2008, IS 17484, and DIN 8077/8078 and ISO 15874 for pipes and DIN 16962 for fittings. Pipes shall be manufactured using Type-3 PPR (PP-R 80) resin with a minimum pressure rating of PN 10, intended exclusively for non-pressure, gravity-based drainage systems in multi-storey commercial or IT buildings. Although pressure-rated, the pipes shall be used only for SWV purposes and not for pressure lines. The PPR pipe shall be of triple-layer construction comprising: Inner layer: smooth bore, corrosion-resistant for optimal flow; Middle layer: mineral-filled for mechanical strength and acoustic dampening; Outer layer: UV-stabilized or abrasion-resistant for durability during handling and installation. Pipes and fittings shall be NSF-certified or equivalent and clearly marked with pressure class, batch number, and standard references. All joints shall be made using socket fusion welding with calibrated welding equipment set to 260 ± 10°C, as per the manufacturer’s guidelines. The resulting system shall be monolithic, gasket-free and leak-proof, without the use of solvent cement, rubber couplings, thread sealants, or mechanical clamps. The system shall include all matching PPR fittings such as long-radius bends, swept tees, reducers, Y-junctions, access fittings, and cowls as per DIN 16962. However, where such fittings are not available in PPR (e.g., floor traps, door tees, cleaning junctions), uPVC SWR fittings conforming to IS 13592 and IS 14735 shall be used. These shall be connected to the PPR lines using leak-proof flange-based transition assemblies, comprising PN 10 PPR flange adaptors, uPVC flange adaptors, and EPDM gaskets (IS 5382), fastened with SS 304 bolts, torqued as per manufacturer’s recommendation. Pipes shall be installed with appropriate slopes for gravity flow (minimum 1% unless otherwise specified). Horizontal lines shall be supported with rubber-lined GI clamps at maximum 0.75 m spacing, and vertical stacks at every floor slab with anchor clamps not exceeding 1.2 m spacing. Where horizontal runs exceed 6 meters, expansion loops or sliding clamps shall be provided. For vertical stacks, telescopic joints or thermal play zones shall be used to accommodate expansion. All wall, slab, or floor penetrations shall be carried out with proper core cutting. Fire-rated walls/slabs shall be provided with intumescent fire collars or sleeves with minimum 2-hour rating, as per NBC 2016 and IS 12458. The pipe shall be restored using 1:3 cement mortar or 1:2:4 concrete after installation. Post-installation, the complete SWV system shall be hydrostatically tested by sealing all open ends and applying a 1.0 m high water column for at least 30 minutes. For vertical shafts, testing shall be carried out up to 1.5 m water head wherever feasible, as per IS 1742 and site conditions. No leakage, sweating, or seepage shall be permitted, and special attention shall be given to flanged transition joints during inspection. All components shall be ISI-marked or certified, and relevant Material Test Certificates (MTCs) shall be submitted for approval. Installation shall be done by manufacturer-certified personnel, and all work shall strictly adhere to CPHEEO Manual, NBC 2016, and other applicable IS codes, ensuring a high-performance, corrosion-free, and long-lasting drainage system suitable for high-rise building applications.
Providing and fixing uPVC SWR inlet assembly with a maximum of three inlets (32 mm, 40 mm, or 50 mm dia as per layout), using IS 13592 (Type B)-compliant factory-moulded door tees or equal tees, joined with approved solvent cement conforming to IS 14587. The inlet assembly shall connect to a self-cleansing uPVC floor trap with minimum 50 mm water seal, fitted with SS 304 or chrome-plated brass grating (hinged type if specified). Trap outlet shall be integrated to a 100 mm dia PPR triple-layer vertical stack (PN 10, conforming to IS 15801:2008, IS 17484, and DIN 8077/8078) using a solvent-weld saddle with reinforcement ring or a flanged adaptor with EPDM gasket conforming to IS 5382, as approved. The assembly shall be embedded in 1:2:4 cement concrete with minimum 75 mm cover and supported using SS 304 clamps at 1.5 m spacing for vertical stacks and slope-adjustable brackets for horizontal branches (minimum slope 1%). The joint shall be tested for leak-proofness using 0.5 m water column head for 30 minutes or as per IS 5329 where applicable. Each inlet assembly shall include one door tee for inspection/cleaning access. All installation shall comply with IS codes, CPHEEO Manual, and NBC 2016. Work shall be executed by manufacturer-trained or certified plumbing technicians, and all materials shall be supported with manufacturer’s test certificates (MTCs).
Providing and fixing uPVC floor drain assembly with 100 mm dia. top inlet and 50 mm dia. outlet, with factory-moulded self-cleansing trap (minimum 50 mm water seal) conforming to IS 13592 and IS 14735. The drain shall include a uPVC frame with integrated stainless steel 304 (Grade 06Cr19Ni10) or CP brass (C83600) grating, securely seated and hinged where specified for routine maintenance. The 50 mm outlet shall connect to a uPVC branch line which transitions to the PPR main stack (100 mm dia., PN 10, conforming to IS 15801:2008, IS 17484, and DIN 8077/8078) through a mechanical saddle adapter with internal EPDM gasket and clamping ring, or through an electrofusion saddle as per manufacturer recommendation. The trap assembly shall be embedded in 1:2:4 cement concrete bedding with 75 mm minimum cover, laid over leveling mortar (1:3), and finished flush with tile level. Slope towards the outlet shall be maintained at minimum 1%. All joints shall be solvent welded (uPVC) or fusion joined (PPR), and transition joints shall be tested for leak-proofness using a 0.5 m water column for 30 minutes, prior to tile work. Work shall comply with NBC 2016, CPHEEO Manual, and relevant IS codes, and shall be executed by trained plumbing technicians using ISI-marked materials supported by MTCs.
Providing and fixing uPVC floor cleanout access assembly for 100 mm and 150 mm SWV lines, comprising factory-moulded uPVC long-radius access bend or inspection tee with CP brass (C83600) threaded cleanout plug, conforming to IS 13592 and IS 14735. The plug shall include an integral O-ring seal and square/hexagonal head suitable for rodding operations. The uPVC fitting shall be solvent welded to the branch line and transitioned to the PPR main stack (PN 10, confirming to IS 15801:2008, IS 17484, and DIN 8077/8078) using a mechanical saddle adapter with EPDM sealing and SS clamping ring, or via approved electrofusion saddle. For 150 mm lines, cleanout assemblies shall be fabricated using factory-moulded 150 mm uPVC inspection tees with reducers and 100 mm CP brass plugs. The cleanout shall be embedded in 1:2:4 cement concrete bedding (min. 75 mm cover), finished flush with the floor, and aligned for direct rodding access. All joints shall be tested for leak-proofness using 0.5 m water column for 30 minutes. The work shall conform to NBC 2016, CPHEEO Manual, IS 13592, IS 14735, IS 17484, and be executed using ISI-marked materials and manufacturer test certificates (MTCs) by qualified plumbing technicians.
100 mm dia
150 mm dia
Providing and fixing 100% stainless steel grating made of SS 304 grade, size 125 mm x 125 mm (square) or 125 mm dia (round), 1 mm thick (±0.2 mm), with circular/slot perforations, suitable for floor trap/floor drain top cover. Grating shall be of satin/matt finish, removable or lockable type as per site requirement, and capable of withstanding foot traffic loads. Item includes cost of all necessary materials and fixing accessories for proper fitting on the drain top. Installation to be carried out as per manufacturer’s guidelines and direction of the Engineer-in-Charge.
Providing and fixing heavy-duty cast iron square grating of size 100x100 mm / 200x200 mm, with minimum thickness of 10 mm, suitable for terrace rainwater pipe (RWP) inlets. Grating shall be of approved quality, cast as a single piece or with integral frame, coated with black bituminous or epoxy paint to prevent corrosion. Grating shall have anti-clog perforation pattern, and be embedded/fixed in cement mortar 1:3 at terrace level or in CI sump box, as required. Item includes all material, labour, and finishing works, and shall be as per direction of Engineer-in-Charge.
100x100 mm size
200x200 mm size
Providing and fixing of closed cell elastomeric nitrile rubber insulation (Class 1 fire-rated as per BS 476 Part 7) on hot water pipes of specified diameters. Insulation shall have thermal conductivity not exceeding 0.0313 Kcal/m·hr·°C at 30°C (equivalent to 0.0364 W/m·K), with temperature range from -40°C to +105°C. Minimum insulation thickness shall be 13mm up to 25mm pipe dia and 19mm for 32mm and above, as per standard practice. All joints shall be sealed with manufacturer-approved adhesive and installed without air gaps. UV-protective coating shall be applied where exposed.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
50 mm dia
Providing and fixing in position storage-type electric water heaters (vertical/horizontal) of ISI-marked approved make with glass-lined or stainless steel tank, PUF insulation (minimum 20 mm), and ABS or powder-coated outer body, complete with thermostatically controlled immersion heater, pilot lamp, safety valve, 15/20 mm inlet with non-return valve, and 15/20 mm outlet. Water heater shall be suitable for wall mounting with necessary MS bolts and supports, and rated for IPX4 or higher protection. Approved Makes: A.O. Smith / Racold / Havells / Venus / Hindware / Jaquar.
6 litres capacity
25 litres capacity
80 litres capacity
Providing and fixing Medium Class (Class B) G.I. Pipes (IS:1239 Part 1) complete with hot-dip galvanized GI fittings (IS:1239 Part 2) and clamps, for concealed drainage piping, including painting with anti-corrosive bituminous paint, cutting chases in walls, placing pipe, applying pipe thread sealant (LOCTITE 55 / equivalent) at joints, and restoring wall surfaces with proper plastering, all as per the direction of Engineer-in-Charge. Pipes shall be tested for leakages before covering.
32 mm dia. nominal bore
40 mm dia. nominal bore
50 mm dia. nominal bore
Supply, installation, testing & commissioning of ISI-marked stainless steel (SS-304 grade) water cooler of storage capacity 300 litres and cooling capacity not less than 80 litres/hour, complete with bubbler tap, drain tap, food-grade SS internal tank, 15 mm inlet with NRV and strainer, and outlet connection with piping to nearby floor drain. Unit shall include drain piping, tested for cooling performance and leakage, and installed complete in all respects as per directions of Engineer-in-Charge.
Providing and fixing of duplex booster pump set at terrace level consisting of 2 nos (1 working + 1 standby) monoblock/vertical multistage centrifugal pumps, each rated for 0.5 LPS flow at 15 m head, suitable for potable water with SS impeller and wetted parts, motor with IP55 protection, Class F insulation, 415V, 3Ph, 50Hz, mounted on common base frame with anti-vibration pads. The scope includes isolation valves, non-return valves, pressure gauge, pressure switch, bends, fittings, and necessary automatic control panel with auto-changeover and motor protection. The entire system shall be supplied, installed, tested (including performance test), and commissioned as per direction of Engineer-in-Charge. Approved Makes: Grundfos / KSB / Kirloskar / Xylem / Ebara
Design, supply, installation, testing, and commissioning of a complete siphonic rainwater drainage system (primary & emergency) from terrace to ground-floor catch basin, using HDPE (PE100, SDR 26 or better) pipes and electro-fusion/butt-welded fittings, including tees, bends, flanges, cleaning doors, clamps, supports, and anti-vortex roof outlets with debris filter. System shall be of Geberit / Hydromax / Valsir make, and design shall be carried out by OEM including hydraulic calculations, layout, and pipe sizing, supported by shop drawings. The scope shall also include loading/unloading, sealing joints to terrace gutters, restoring floors/walls, and final connection to ground-level stormwater line/catch basin. All piping shall be pressure tested as per manufacturer's guidelines prior to commissioning. Quantity: Complete Job
Providing and fixing in position pre-cast R.C.C. manhole cover and frame, circular shape, 560 mm clear opening, HD-20 load class (20 tonnes) conforming to IS:12592 (Part 1 & 2), with adequate reinforcement and proper curing. The cover shall be provided with cast load class marking and IS code, and the frame shall be firmly seated and grouted in cement mortar (1:4). The item includes all labour, loading/unloading, and making good the surroundings after installation. Approved Makes: KGM / KK / Nutek
Providing and fixing gun metal gate valve (screwed end) conforming to IS:778, with C.I. handwheel, suitable for PN 16 working pressure, including threading, use of approved thread sealant (LOCTITE 55 / equivalent), and all accessories as required for complete installation. The valve shall be factory tested for pressure and installed as per good plumbing practice to avoid pipe strain.
25 mm nominal bore
20 mm nominal bore
32 mm nominal bore
40mm nominal bore
50 mm nominal bore
65mm nominal bore
80 mm nominal bore
Providing and fixing 3-layer PP-R (Polypropylene Random Copolymer Type 3) pipes conforming to IS 15801:2008, IS 17484, and DIN 8077/8078, manufactured using NSF-certified raw materials, UV stabilized and anti-microbial, suitable for hot and cold water supply applications. Pipes shall be of PN 16 pressure rating (SDR 7.4) and jointed using socket fusion welding technique. The scope includes supply and installation of all required PP-R fittings and accessories such as 90° and 45° elbows, equal and reducing tees, reducer couplers, end caps, male and female threaded adaptors, metal inserts, flange cores, slip-on flanges, nuts, bolts, washers, custom-fabricated fittings as required by layout, and rubber-lined pipe clamps fixed at a maximum spacing of 1.00 metre. The work shall include cutting of wall chases, embedding the pipework, and making good the wall surface after installation. All joints shall be pressure tested hydrostatically at 1.5 times the working pressure. PPR unions shall be measured and paid for separately under relevant BOQ items. The work shall be carried out complete in all respects as per specifications and the direction of the Engineer-in-Charge.
PN - 16 Pipe, 20mm OD (SDR-7.4)
PN - 16 Pipe, 25mm OD (SDR-7.4)
PN - 16 Pipe, 32mm OD (SDR-7.4)
Providing and fixing 3-layer PP-R (Polypropylene Random Copolymer Type 3) pipes conforming to IS 15801:2008, IS 17484, and DIN 8077/8078, manufactured from NSF-certified raw materials, UV stabilized and anti-microbial, suitable for hot and cold water supply. Pipes shall have a pressure rating of PN 16 (SDR 7.4) unless otherwise specified and shall be joined by socket fusion welding using manufacturer-recommended tools. The scope includes supply and installation of all required PP-R fittings and accessories such as 90° and 45° elbows, equal and reducing tees, reducer couplers, end caps, male and female threaded adaptors, metal inserts, and custom-fabricated fittings as required by the layout. Pipes shall be fixed exposed on internal walls using rubber-lined anchor clamps with appropriate fasteners at a maximum spacing of 1.00 metre. The installation shall include proper alignment, securing, and hydrostatic testing at 1.5 times the working pressure. PPR unions shall be measured and paid for separately under relevant BOQ items. The work shall be carried out complete in all respects as per specifications and the direction of the Engineer-in-Charge.
PN - 16 Pipe, 20mm OD (SDR-7.4)
PN - 16 Pipe, 25mm OD (SDR-7.4)
PN - 16 Pipe, 32mm OD (SDR-7.4)
PN - 16 Pipe, 40mm OD (SDR-7.4)
PN - 10 Pipe, 50mm OD (SDR-11)
Providing and fixing PP-R unions made from Polypropylene Random Copolymer Type 3, conforming to IS 15801:2008, IS 17484, and DIN 8077/8078 and manufactured using NSF-certified raw materials, UV stabilized and anti-microbial, suitable for hot and cold water supply systems. The unions shall be suitable for PN 16 pressure rating and joined to PP-R pipelines using socket fusion welding as per manufacturer's instructions. Where required, unions shall be provided with integrated brass inserts for threaded connections to valves, taps, or equipment. These fittings shall be used strategically at maintenance-prone or terminal points such as near valves, geysers, pumps, or sanitary fixtures to allow disassembly without pipe cutting. All installed unions shall be hydrostatically tested as part of the overall line pressure test.
PPR Union 20mm
PPR Union 25mm
PPR Union 32mm
PPR Union 40mm
PPR Union 50mm
PPR Union 63/65mm
PPR Union 75mm
Providing and fixing 3-layer PP-R (Polypropylene Random Copolymer Type 3) pipes PN 10 conforming to IS 15801:2008, IS 17484, and DIN 8077/8078, manufactured from NSF-certified raw materials, UV stabilized and anti-microbial, suitable for hot and cold water supply in exposed, shaft, and terrace areas. Pipes shall have PN 16 pressure rating (SDR 7.4) and shall be joined using butt fusion welding with electro-fusion fittings or as per manufacturer's recommendation for sizes above 63 mm. The scope includes supply and installation of all required PP-R fittings and accessories such as elbows, tees, reducers, end caps, threaded adaptors, and custom-fabricated bends. Pipes shall be supported using galvanized MS clamps or structural hangers, anchored at proper intervals (as per load and layout) to ensure alignment and allow for thermal expansion control through offsets or flexible joints where required. All joints shall be hydrostatically tested at 1.5 times the working pressure. The work shall be carried out complete in all respects as per specifications and direction of the Engineer-in-Charge. PPR unions, if any, shall be measured and paid separately.( Sump riser, Rain water harvesting risers, Ceiling of basement etc)
PN - 16 Pipe, 143.8 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 208.6 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 250mm OD (SDR-7.4) outer dia as per IS 15801
Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing. Up to 300 mm dia
Providing and fixing M.S. foot rests inside water tanks or manholes using 20 mm x 20 mm square bar, conforming to standard design and fabricated from mild steel of grade Fe410. Each foot rest shall be embedded in 20x20x10 cm cement concrete blocks of mix 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate, 20 mm nominal size) and spaced at 300 mm vertically. Foot rests shall be hot-dip galvanized or coated with two coats of anti-corrosive epoxy paint over a zinc chromate primer to ensure corrosion protection in moist conditions. The fixing shall ensure stability, alignment, and safety during use. Installation shall be completed as per CPHEEO standards and the direction of the Engineer-in-Charge.
Providing and fixing 3-layer PP-R (Polypropylene Random Copolymer Type 3) pipes conforming to IS:15801, manufactured from NSF-certified raw materials, UV stabilized and anti-microbial, suitable for hot and cold water supply in exposed, shaft, and terrace areas. Pipes shall have PN 16 pressure rating (SDR 7.4) and shall be joined using butt fusion welding with electro-fusion fittings or as per manufacturer's recommendation for sizes above 63 mm. The scope includes supply and installation of all required PP-R fittings and accessories such as elbows, tees, reducers, end caps, threaded adaptors, and custom-fabricated bends. Pipes shall be supported using galvanized MS clamps or structural hangers, anchored at proper intervals (as per load and layout) to ensure alignment and allow for thermal expansion control through offsets or flexible joints where required. All joints shall be hydrostatically tested at 1.5 times the working pressure. The work shall be carried out complete in all respects as per specifications and direction of the Engineer-in-Charge. PPR unions, if any, shall be measured and paid separately.
PN - 16 Pipe, 65.50 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 82.4 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 98.20 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 117.6 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 143.8 mm OD (SDR-7.4) outer dia as per IS 15801
PN - 16 Pipe, 208.6 mm OD (SDR-7.4) outer dia as per IS 15801
Providing, installing, testing, and commissioning of motorized valve system with integrated control unit for automatic overhead tank filling. Valve shall be electrically operated ball or butterfly type, suitable for PN 10/PN 16 pressure, fabricated from brass (for sizes up to 50 mm) or cast iron with epoxy coating (for sizes ≥ 65 mm), and equipped with ON/OFF-type electric actuator rated for 230 V AC operation. The actuator shall be weatherproof to IP65 protection. The system shall include a control unit housed in a weatherproof IP65-rated FRP/polycarbonate enclosure, suitable for outdoor installation, and comprising control transformer, contactors, MCBs, indicating lamps, terminal blocks, BMS-compatible potential-free contacts, and necessary cabling with IP65-rated cable glands. The control panel shall operate in conjunction with a float switch or level sensor for maintaining tank levels between 70% (low) and 100% (full), with provision for automatic ON/OFF of the motorized valve. System shall be complete with all control wiring, internal interconnections, cable terminations, earthing, testing, and commissioning as per approved drawings and engineer’s instructions.
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
100 mm nominal bore
Providing and fixing mild steel puddle flanges fabricated from M.S. plate of minimum 8 mm thickness (grade Fe410), suitable for pipe diameters ranging from 40 mm to 200 mm, for use at locations where pipes pass through concrete walls, sumps, wet wells, or underground tanks. Each puddle flange shall consist of a circular collar welded concentrically around the pipe sleeve or embedded pipe section and shall be provided with anchoring lugs to ensure rigid placement within concrete. The puddle flange shall be hot-dip galvanized or coated with two coats of anti-corrosive epoxy paint over a zinc chromate primer to ensure durability against corrosion. Installation shall include proper alignment, positioning, and embedding during concreting or grouting as per structural engineer's direction. The item shall be completed in all respects as per approved drawings and instructions of the Engineer-in-Charge.
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200mm dia
Supply, installation, testing, and commissioning of a factory-assembled solar water heating system (closed loop type) of 100 litres per day capacity per set, consisting of two flat plate solar collector panels (minimum 2.0 m x 1.0 m each) with diamond-shaped fluid channels, nickel electroplated and polyester powder-coated black absorber plates, designed for normal stagnation temperatures up to 120°C in accordance with MNRE guidelines. Each system shall be supplied with a 100 litre factory-tested mild steel hot water storage tank, internally coated with double ceramic lining, externally insulated with 360° factory-applied thermal jacket, and rated for a minimum hydrostatic test pressure of 300 psi (2100 kPa). The tank shall be complete with electrical booster heater, sacrificial magnesium anode rod, safety valve, cold expansion valve, and in-line strainer. The scope shall include: Interconnecting copper piping (Type L or equivalent), insulated with 19 mm UV-resistant nitrile rubber. Structural mounting supports suitable for rooftop installation (wind load resistance ≥150 km/h). Sensors, wiring, control cabling, BMS-compatible signal outputs, and accessories. The entire solar water heating system shall comply with IS:12933, IS:3024, IS:13287, and MNRE standards, and carry a 5-year comprehensive replacement warranty. Approved Makes: V-Guard / Emmvee / Racold / Tata Power Solar.
Providing, fixing, testing, and commissioning of adjustable Pressure Reducing Valves (PRVs) suitable for potable water applications, with inlet pressure rating of minimum 15 kg/cm² (1.5 MPa). PRV shall be constructed from corrosion-resistant material such as forged brass or stainless steel with EPDM rubber internal diaphragm and O-rings, suitable for working temperature up to 80°C. The valves shall be factory preset and field adjustable within a range of 1.5–6.0 bar. Each valve shall be supplied with an integrated or inline strainer upstream (where applicable) to protect the valve from scale or debris. PRVs shall conform to EN 1567 / ASSE 1003 or equivalent standard. Installation shall include proper alignment, threading or flanged connections, testing of outlet pressure, and compliance with manufacturer's guidelines. Approved Makes: Zurn / Caleffi / Honeywell / Watts / Reliance / HNB / Sant
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing, installing, testing, and commissioning of 2000 litres capacity insulated hot water storage tank, fabricated from SS 304 grade stainless steel, minimum 14 SWG thickness (cylindrical shell with dished ends), non-pressurized type, suitable for domestic hot water storage up to 90°C. The tank shall be complete with: 18” dia manhole cover, thermometer (0–120°C), air vent, drain valve, overflow, inlet and outlet nozzles (minimum 2” dia) made of SS 304 Sch. 40 pipes with flanged ends. External insulation with 100 mm thick resin bonded glass wool (density 48–64 kg/m³), covered with chicken mesh and finished with 22 SWG aluminium cladding. MS fabricated pedestal/base support structure, duly painted with one coat of red oxide primer and two coats of enamel paint of approved shade. The tank shall be suitable for rooftop or plant room installation, and fabricated in line with IS:2825 (where applicable) and good industry practice. Approved Makes: Beekay / Indo Tech / Venus / V-Guard
Excavation of trenches of specified width (minimum width = external diameter of pipe + 300 mm) for laying pipes, cables, or similar underground services including excavation for sockets, dressing of sides, ramming of bottoms to proper level, disposal of surplus earth within a 50 m lead, and returning the excavated soil in layers not exceeding 200 mm depth with watering and ramming each layer for proper compaction. The work shall include the supply and laying of a 100 mm thick sand/murram bed below the pipe/cable, and compaction shall be done using hand rammers or mechanical means as appropriate. The depth of trench shall not exceed 1.5 m. If the trench passes through unstable soil or waterlogged areas, dewatering and trench safety measures such as timbering/shoring shall be done as per site conditions and shall be paid separately if not included. All work shall be executed in line with IS:1200 Part I & Part XVII and as per the direction of Engineer-in-Charge.
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Extra over basic trench excavation rates for additional excavation for trenches in all types of soil (excluding rock) for depths exceeding 1.5 m and up to 3.0 m, required for laying pipes, cables, or other underground utilities. The work includes extending the width and depth of excavation as per design, dressing of sides, ramming of bottoms, lifting and disposing of surplus earth within a lead of 50 m, and returning the excavated earth in layers of not more than 200 mm thickness with proper watering and compaction. Trench width shall match the specification in the base item (pipe OD + 300 mm minimum). The item excludes dewatering, hard rock excavation, and trench protection, which shall be paid separately if required. All work shall be in accordance with IS:1200 and direction of Engineer-in-Charge.
Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete ( In road crossing ) 450 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches for pipes including bed concrete as per standard design.
150 mm dia.
200 mm dia
250 mm dia.
300 mm dia.
400 mm dia
500 mm dia.
600 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
150 mm dia.
200 mm dia.
250 mm dia.
300 mm dia.
400 mm dia
500 mm dia.
600 mm dia.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Constructing RCC road gully chamber 50x45x60 cm with mixture m 25 including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : Gully chambers
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : Gully chambers
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With Sewer bricks conforming to IS : 4885
Providing and laying non-pressure NP2 class (light duty) R.C.C pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) including testing of joints etc. complete: 1000 mm dia. R.C.C pipe
"Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With Sewer bricks conforming to IS : 4885
Extra for depth for manholes :
Size 90x80 cm With Sewer bricks conforming to IS : 4885
Size 120x90 cm With Sewer bricks conforming to IS : 4885
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter con forming to I.S. 12592, total weight of cover and frame to be ot less than 182 kg., fixed in cement concrete 1:2:4 (1 : cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) With Sewer bricks conforming to IS : 4885
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With Sewer bricks conforming IS : 4885
"Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design" "1.68 m deep with SFRC Cover and frame (heavy duty HD 20 grade designation) 560 mm internal diameter conform ing to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :" With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With Sewer bricks conforming IS : 4885
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design .30 m deep with SFRC Cover and frame (heavy duty HD 20 grade designation) 560 mm internal diameter conform ing to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : With Sewer bricks conforming IS : 4885
Sewer & Storm -Providing, laying and jointing , testing , in position Double coiled wall HDPE, SN 8 pipe as per IS:16098 Part-2 and suitable for the respecting working pressure with all fittings complete. The jointing shall be butt fusion welding as per manufacturer specification and IS code and specification.(C C all round and upto haunching shall be paid separately)
150 mm diameter
200 mm diameter
250 mm diameter
300 mm diameter
400 mm diameter
500 mm diameter
600 mm diameter
Providing, testing, commissioning of modular harvesting pit CGWB/GRIHA approved Filter etc all complete. All structures should be suitable to cater the load of fire tender movement (With 2 bores each 160 mm dia, depth up to 100 m / as per hydrological report). Earth work excavation with JCB/ excavators in all type of soil and with a lift up to 5 meters. Sand of 100 mm thick bed at the base of tank for proper compaction. Aggregate (40-60mm) of 100 mm thick bed at the base of tank for proper compaction. Soil disposal- disposal of extracted soil from the site to inside the boundary walls of the building up to a maximum distance of 0.5 KM. Permission will be provided by client. Supply & laying of 400 GSM non woven Geo Textile To avoid invasion of soil, provide stability to the tank, and improve quality of water within the tank as required. Rate shall inclusive of 3 HP submersible drainage/dewatering pump to use the storage rainwater irrigation, all complete with valves, adequate size CPVC sump riser, fittings, Electrical panel and all related accessories. Pumping set shall be 1 working + 1 stand by. Supply, installation, testing & commissioning of modules made up of 100% recycled polypropylene capable of taking atleast 30 tonnes per sqm. These modules are made from combination of large (683*410mm) and small (369*410mm) plates along with external locks. Each large plate should have atleast fourteen external locking slots inorder to give stability to tank. These tank should have optimum connection & block stability using double lock stability. Each single tank is made of four large and four small plates in case of single tank and 10 large & 12 small plates for triple tank. Capacity of single tank is (.683*.410*.450) equals to 0.126 CUM. Weight of each large plate should be atleast 1050 gms and each small plate should be atleast 550 gms. Backfilling of the area constructed in and around after compacting them properly. Desilting Chamber as per GFC drawings and as required as per flow and volume of storm water. Brick work around micro filter Installation of modular tank Supply, installation, testing & commissioning of FRP Filter having SS 304 mesh bracket with dia 750mm and height 1000mm having flow rate of atleast 82.5 CUM /Hr capable of removing particles from infllow water. FRP filter should be Griha certified under criterions 21& 18 and SVAGRIHA criterion 9. Certificate should be valid on date of installation. Make: Rehau, Frankische, Graf, Retas Enviro Solutions, Atlantis lifting at any height, loading, unloading all taxes charges, all I & M, T & P as complete job Nothing extra will be paid whatsoever the case may be. All structures should be suitable to cater the load of fire tender movement. Capacity - 100 cum
Providing and Fixing Modular Grease Separator plant certified recessed under floor or floor mounted spoxy coated steel/HDPE grease interceptor with gasketted solid steel cover, hex head centre bolts, removable baffle assembly, deep seal trap with clean out, no hub connections & external cast iron flow control fittings, with manhole cover, 1 set of operating keys, nominal connection size 75mm, odour proof sealed, with direct suction pipe, along with all necessary accessories and equipment complete including necessary foundations, civil works and finishing as per site requirements and as per instructions of the engineer in charge.This shall be provided with sediment bucket epoxy coated steel located inside the interceptor on inlet side, collects large food or other particles, to the extent possible, sediment should be strained or collected at the fixture prior to the grease interceptor, sediment entering the waste line is likely to clog the interceptor flow restrictor, slowing drainage, and causing backup difficulties, Heavy duty traffic cover rated 10,000 lbs. , flange and clamp device complete as required or approved by EIC/ manufacturer recommendations. Grease trap design shall be based on 5000 to 7000 meals per day. Size as per manufacturer design/standards
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with surface box with lockable arrangement, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per approved drawing and specification : With common burnt clay F.P.S.(non modular) bricks of class designation
Providing, laying and jointing in position PPR PN 16 pipe conforming to IS 15801:2008, IS 17484, and DIN 8077/8078 and certified by NSF for water supply applications, suitable for the respective working pressure with all fittings complete. The jointing shall be by socket fusion welding as per approved drawing and specification, including excavation in all kinds of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. Hydrostatic testing shall be carried out at 1.5 times the working pressure. (For Irrigation, water supply line).
Providing & fixing in position 25 mm dia lawn hydrants consisting of 25 mm dia Ball valve, GI nipple (1.5 metre length), and threaded hose receiver complete as required.
Supply, installation , testing & commissioning of male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass ball & teflon seat tested to a pressure 24 Kg / sqcm with threaded joints complete as required.
25mm diameter
40mm diameter
50 mm diameter
Supply, Installation, Testing and commissioning of slim seal type PN 25 C.I. Butterfly valve confirming to IS 13592 (Body : Grey Cast Iron, shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) of approved make with PN 25 rating flange dimensions shall be confirming to IS 6392, washer, nuts & bolts. Rated to temperature of 85 Deg C and tested to a pressure not less than 24 Kg/Sq.cm.
40mm diameter
50 mm diameter
65 mm diameter
80 mm diameter
100 mm diameter
150 mm diameter
Supply, Installation, Testing and commissioning of galvanised pipes conforming to IS:1239 (heavy grade) and fittings conforming to IS:1239/ASTM A 105 (GALVANISED) and as per piping materials specification Class including supply of teflon tapes, white lead, etc. cutting the pipes to required lengths, making threads, including laying of pipes on sleeper, walls, including erecting piping on columns, etc. for pump station, etc.including joining the pipes and fittings with threaded connections, hydrostatic testing of the piping including supply of necessary fittings etc & pipe supports. complete as per specifications, drawings and instructions of Engineer-in-Charge. For following Nom. Size in mm and piping class..( Pump room)
80 mm diameter
150 mm diameter
200 mm diameter
250 mm diameter
300mm diameter
Domestic water transfer pump: Location - Domestic WTP Pumps Capacity 5 LPS Each (3W+1S) Head 90 m
Flushing water transfer pump: Location - STP Pumps Capacity 5 LPS Each (2W+1S) Head 90 m
Soft water transfer pump to OHT for HVAC : Location - Location - STP Pumps Capacity 6 LPS Each (2W+1S) Head 90 m
Filter Feed pump: Location - Domestic WTP Pumps Capacity 5 LPS Each (3W+1S) Head 40 m
Filter Transfer pump to Treated water tank STP to full fill the replenish water of STP: Location - Domestic WTP Pumps Capacity 5 LPS Each (2W+1S) Head 45 m
R.O transfer pump : Domestic WTP Pumps Capacity 2 LPS Each (1W+1S) Head 90 m
Irrigation Water transfer pumps - 3 LPS each (1W + 1 S) - Head - 70 meter
Supply, Installation, Testing and commissioning of Fully submersible with a fully submersible motor as per IP68 with F-Class insulation. The pumps shall be provided with an automatic level controller and all interconnecting power and control cabling which shall cause the pumps to operate when the water level in the sump rises to a preset level and stop when the preset low level is reached. Impeller: Cast Iron Delivery Casing: Cast Iron Motor Body: Cast Iron Pump Shaft: Carbon Steel Pumps for drainage shall be single stage, single entry. Impeller clearance (i) Drainage sump pumps 20 mm solid handling, (ii) Sewer pumps min. 40 mm soild handling. Pump shall be C.I. casing and C.I. two vane open type with a dynamically balanced impeller connected to a common shaft of the motor. The vane for sewage pump will be open type, while for drainage pump, etc. it will be of semi open type. The MOC of the sump shall be in accordance to schedule of quantity. Stuffing box shall be provided with mechanical seals. Each pump shall be provided with in built liquid level controller for operating the pump between predetermined levels. The pumping set shall be for stationary application and shall be provided with pump connector unit. The delivery pipe shall be joined to the pump through a rubber diaphragm, and bend and guide pipe for easy installation. Pump shall be provided with all accessories and devices. Level control shall be such that one pump starts on required level, 2nd pump cuts in at high level and alarms is given at extra high level. All level controllers shall be provided with remote level indications. Power and control wiring 10 m between the motor and the panel , excpet 30m for pumps at sl. Tandem, rubber bellow seals in oil between stator housing and pump. Control panel for set up adequate nos. submersible pumps complete with MCBs, Ammeter, voltmeter, LED indication switch. Continuous rating, Squirrel cage Induction motor, housed in air filled water tide enclosure, 415 V, 3 phase, 50 Hz AC, motor winding Class H insulation, dry run protection for motors
Drainage sump pumps - 5 LPS each (1 W + 1 S) - Head - 25 meter - For Domestic Pump Room
Drainage sump pumps - 5 LPS each (1 W + 1 S) - Head - 25 meter - For STP Pump Room
Drainage / Sewage sump pumps - 5 LPS each (1 W + 1 S) - Head - 25 meter - For Lower floor /Basement drainage
De - watering pumps Pumps Capacity 10 LPS Each (3W+1S) Head 35 m
Supply, installation , testing & commissioning of digital electronic water meter with direct reading dial in KL with all internal parts in gunmetal or brass, flanged distance piece for easy removal in future, strainer, 100mm dia Bourden type pressure gauge and isolation cock complete in all respects.
80 mm dia nominal bore for water Supply
100 mm dia nominal bore for water Supply
150 mm dia nominal bore for water Supply
Supply, installation , testing & commissioning of 600 mm long MS hot dip galvanized Puddle Flange fabricated out of 6 mm thick MS plates of suitable size and IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more). 25mm to 400 mm dia
Supply, installation , testing & commissioning of mosquito proof brass overflow grating for underground/overhead water tanks. 150 mm dia
Supply, installation , testing & commissioning of insect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete. 150 mm dia
Providing, fixing, testing and commissioning online water meter confirming IS 779 & IS 2373 with direct reading dia.l in KL with all integral parts of gun metal or brass with necessary fitting such as threaded pieces, unions, strainer, flanges etc. complete in all respect.
50 mm dia (Threaded ends)
250 mm dia (Flanged ends)
Providing & fixing, testing & commissioning CI body Y Strainer (screwed / flanged) with stainless steel fin wire mesh perforated sheet (AISI-304) basket with necessary flanges as per PN:10, Table F / unions nuts, bolts and wahsers complete in all respect and as per the directions of Engineer.
150 mm dia
100 mm dia
250 mm dia
Providing, fixing, testing & commissioning CI body Bucket Strainer (flanged) with stainless steel fin wire mesh perforated sheet (AISI-304) basket with necessary flanges as per PN:10, Table F nuts, bolts and wahsers complete in all respect and as per the directions of Engineer.
200 mm dia
250 mm dia
350 mm dia
Providing, fixing, testing & commissioning Flexible SS bellows confirming to EGMA suitable for PN 16 (flanged) including nuts, bolts and wahsers complete in all respect and as per the directions of Engineer.
100 mm dia
150 mm dia
200 mm dia
250 mm dia
350 mm dia
Providing, fixing, testing & commissioning pressure transmitter, control valve with strainer for each compartment of water tank, control & power wiring compatible for BMS system, complete in all respect and as per the directions of engineer in Charge.
Providing, fixing, testing & commissioning suitable size common screen (Liquid crystal display panel) for tanks for displaying the water level in each compartment compatible for BMS system for automation of pumps, complete in all respect and as per the directions of Enginner in Charge.
Providing, fixing, C.I. Manhole covers 600x600 mm (Medium)including frame , complete all respects
Providing, fixing, C.I. Manhole covers 550 x550 mm DIA (Medium) including frame , complete all respects
Providing, fixing, testing & commissioning CI body Bucket Strainer (flanged) with stainless steel fin wire mesh perforated sheet (AISI-304) basket with necessary flanges as per BS:10, Table F nuts, bolts and wahsers complete in all respect and as per the directions of Engineer in-Charge.
200 mm dia
250 mm dia
350 mm dia
Supply, Installation, Testing and commissioning of slim seal type PN 25 C.I. Butterfly valve confirming to IS 13592 (Body : Grey Cast Iron, shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) of approved make with PN 25 rating flange dimensions shall be confirming to IS 6392, washer, nuts & bolts. Rated to temperature of 85 Deg C and tested to a pressure not less than 24 Kg/Sq.cm.
40mm diameter
50 mm diameter
65 mm diameter
80 mm diameter
100 mm diameter
150 mm diameter
200 mm diameter
Supplying installing, testing & commissioning of Water Softener Plant of capacity 240 KLD (excluding excavation, back filling & disposal of surplus earth /Civil construction work) (Contractor to submit TDS documents for approval before execution of work) Location : STP
Supply & Installation, testing and commissioning of vertical self supporting Dual filter vessel fabricated from MS sheet as per IS : 2825 pressure gauges at inlet & outlet with isolation cock, sampler cock, air vent with isolation valve, MS 'C' Class face piping/distribution pipe with diffuser, CI butterfly valves and all accessories, with initial charge of filter media, painting inside with food grade epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint complete with bypass arrangement. Dual Media Pressure Sand Filter Flow rate - 30 KLPH Diameter : 2000 mm or as per manufacturer specification Shell thickness : 6 mm. Dish thickness : 8 mm Height : 2100 mm Filter Media : Multigrade River Pebble and Anthracite Filtration rate : 30000 L / h / sqm. MOC : M.S. Manhole size : 450/550mm "Working Pressure : 3.5 Kg/Sq.cm. Dia of face piping 50mm dia. M.S.Pipe ""C"" class." Internal Finish: Two coats of anti- corrosive, food grade epoxy paint External Paint : Two coat of Primer and two or more coats of enamel paint of approved shade. Item as Described above
Supply & installation, testing and commissioning of vertical self supporting Softner Filter vessel fabricated from MS sheet as per IS : 2825 pressure gauges at inlet & outlet with isolation cock, sampler cock, air vent with isolation valve, MS 'C' Class face piping/distribution pipe with diffuser, CI butterfly valves and all accessories, with initial charge of filter media, painting inside with food grade epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint complete with bypass arrangement. Water Softner Flow rate - 30 KLPH Diameter : 2100 mm or as per manufacturer specification Shell thickness : 6 mm. Dish thickness : 8 mm Height : 1800 mm Filter Media : ION EXCHANGE RESIN Incoming Hardness: 350PPM Output Hardness : <5PPM OBR: 420 KL Filtration rate : 30000 L / h / sqm. MOC : M.S. Manhole size : 450/550mm "Working Pressure : 3.5 Kg/Sq.cm. Dia of face piping 50mm dia. M.S.Pipe ""C"" class." Internal Finish: Two coats of anti- corrosive, food grade epoxy paint External Paint : Two coat of Primer and two or more coats of enamel paint of approved shade. Item as Described above
Supply & installation, testing and commissioning of MS body internally rubber lined/FRP brine tank complete with salt mixing agitator,painting, testing kit, testing & commissioning complete.
Supply & installation, testing and commissioning of chlorine dosing system (for domestic water treatment plant) consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-10 lph @4kg/sqcm. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke control (for domestic water transfer pump).
Supply & installation, testing and commissioning in position the following heavy class (Class C) GI pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 - part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc. Fixing at wall/ceiling level supported by galvanized clamps, hangers etc as per specification or chasing in wall / floor and making good the same by using 1:1 cement mortar over the wire mesh. Threading, jointing, and making proper connections. Cutting hole in wall / floor / slab and making good the same and complete as required.Cost shall be inclusive of providing two coats of synthetic enamel paint of approved shade on exposed pipes, over a coat of zinc, primer, including painting of legends with direction arounds.(Pipe qty for inside pump room only)
25 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Supply & installation, testing and commissioning cast iron butter fly valves of PN 1.6 rating with SS 304 grade disc (Conforming to I.S.13095 ) complete with bolts, nuts, 3 mm thick compressed asbestos gasket, companion flanges in all respects.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Supply & installation, testing and commissioning of CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh/ perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required suitable for 16Kg/cm2 pressure (on pump suction).
100 mm dia
150 mm dia
200 mm dia
Supply & installation, Testing and commissioning of Resilient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table E complete suitable for working pressure of 20 Kg/sqcm. And temperature of 50°c.at all level and position as directed by Engineer-in-charge.
80 mm dia
100 mm dia
150 mm dia
Supply & installation, testing & commissioning of Vertical/Horizontal Dual Plate non return valve conforming to IS: 778 and tested to a pressure not less than 15 Kg/Sqcm, Including rubber gasket, flanges, union, nuts, bolts & washers complete as required.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supply & installation, testing and commissioning full bore brass ball valve suitable for 15kg/sqcm working pressure full bore type with lever and female screwed ends, of approved quality.
25 mm dia
40 mm dia
Supply & installation, setting, testing and commissioning of pressure gauge with isolation cock, all complete.
Supply, installation testing and commissioning of Electro-Magnetic flow meter suitable for 200 KLD Plant with preamplifier and microprocessor including necessary cabling, conduit, etc complete suitable for raw sewage application. Szie : 150"
Supply and fixing 25 mm dia gunmetal fitting for water level indicator gauge with isolation cock at top and bottom heavy gauge transparent polythelyne tube of upto 3.0 M length, 100 mm wide x 20 mm thick teak wood /Metal indicating board painted with level indications in cms and litres.(For Under Ground Water Tanks)
SOFTENING PLANT ELECTRICAL PANEL
Design, fabrication, assembling, wiring, Supply Installation & Commissioning , installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 1 No. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz Supply system. Lifting hooks shall also be provided in case of large panels. Motor Control Centre Incoming and outgoing as per manufacturer and as required.
Supply Installation & Commissioning ing, installing, testing & commissioning of Cables , Conector, Cable Trays, to make Electrical Installation Complete. a) Cable Type - 2-4 Core Capacity - As per the control panel and machines to connected. Size of cable - 1sqmm-4sqmm b) Cable Tray Qty - As required Type - Slotted GI Size - 2" x 4" X6" or as required. c) Cable Tray Support Quantity - As per site requirment of approved quality.
Detail Engineering, procurement, fabrication, inspection, Supply, manufacture, transportation of all equipments/materials to work site, assembly, erection & installation, painting, Testing & Commissioning of RO station of following capacity, Cost shall be inclusive of MGF filter, ACF filter, RO membrane, Antiscalent Dosing and pH dosing and pH correction, Ozone disinfection, High pressure pump (1W+1S), complete as required. System shall be having capacity to treat the raw water having TDS 500 ppm. The treated water should have TDS less than 100 ppm or as per IS 10500 and WHO standards. The operating voltage to 230 volt AC +/- 10% alongwith required capacity high pressure pump and solenoid valves, dry run protection of pump, automatic tank level control, inbuilt auto flush timer for periodic flushing of membranes, over voltage and over current protection with switch mode power supply system complete in all respects including installation, The quoted price shall include the RO chilled water supply pump with standby arrangement , to supply the water to RO water storage tank. SS - 316L piping fittings. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. with pre and post dosing complete as per manufacturer' specifications, Raw water Feed Pump (1W+1S), All instrumentation, Interconnecting SS 316 pipeline from tank to RO, RO to tank, tank to chilling machine and pump inlet etc. complete in all respects., SS water tank for drinking water 3000 capacity with all required accessories and valves. RO Water Transfer Booster Pump along With Pressure Vessel and Pressure Switch Pump Single Phase Operated. All type of pumps shall have with equal capacity standby provisions. The contractor have to submit shop drawings, TDS of all pumps and equipments for consultant. SS Tank Specification:- SS water tank for drinking water and kitchen storage, tank shall be provided with Inner layer SS316 + Outer Layer SS 304 of specified thickness, tank should be provided with inlet, outlet and vent/overflow connection, 100mm Puf Insulation , manhole cover 450mm dia, Inlet connection of water tank shall be of 25mm nominal bore, overflow/vent - 25mm nominal bore and outlet connection at bottom of tank of 40mm nominal bore. Cost of tank shall be inclusive of Angle stiffeners, stand leg, SS flanges connecting from water treatment facility and distribution system complete as per approved specifications. (contractor shall provide drawing to civil contractor for tank foundation) (Thickness of inner layer 0.8mm & outer layer .6mm) Contractor shall require to submit test report post installation of RO plant and cost shall be inclusive of 15 days training to engineer in charge RO plant capacity - 2000 LPH( 10 hr working) Complete Job
RO WATER COOLING PLANT
Design, Supply, installation , testing & commissioning of RO water cooling plant of 2000 LPH with ( Suitable chilling machine of reuired TR ) with scroll/reciprocating compressor, complete in all respects. The chilling machine shall include condensor, electrical panel, interconnecting piping, refrigerant piping with controls, PHE (One side refrigerant and one side RO water). The system shall be insulated and complete with necessory accessories. The machine shall be associated with control panel, motors 3 phase. The complete system shall be skid mounted. The refrigerent shall be HFC free, ECO friendly, ZERO ODP & GWP. The contractor have to submit shop drawings, TDS of all pumps and equipments to consultant for approval.
Fire fighting works Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Split casing Horizontal type, multistage, multi outlet, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM air cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. b. Radisator cooled diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required. 2850 lpm at 90/110 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Split casing, Horizontal type, multistage,multioutlet, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Hydrant & Sprinkler System 180 lpm at 90/110 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Split casing, Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
Supplying, fixing, testing and commissioning of CI butterfly valve with temper switch of PN 24 rating with SS seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing , installation , testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304 , sheet with 3 mm dia holes with stainless steel flange .
250 mm dia
Supplying , fixing , testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle , bronze/gun metal seat , ISI marked complete with nuts , bolts , washers , gaskets and conforming to IS 780 of following sizes as required :
65 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 25 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 32 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 40 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 50 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 65 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 80 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 100 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 150 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 200 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 250 mm dia
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe (For Suction & delivery Headers) 300 mm dia
Providing, fixing, testing & commissioning of Installation Control Valve of cast iron body , brass /bronze working parts comprising of water motor alarm , bronze seat clapper , clapper, arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser / sprinkler system activates, pressure gauges, emergency releases , strainer , pressure switch, cock valve complete with drain valve and bypass , test control box, ball valves, MS pipe of requried size, flanges, orifice plate , gasket etc of follwing sizes as required: 150 mm dia
Supplying, installation, testing and commissioning of Flow meter with differential pressure meter and associated fittings.Meter faces with direct readout in both GPM (gallons per minute) and LPM (liters per minute) complete in all respects. 150 mm dia
Providing & fixing Mild Steel Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of 100mm dia for the engine. The pipe shall be insulated with 100 mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet.
Providing, fixing, testing and commissioning of air vessel conforming to IS 2825 (size 450 mm dia & 2000 mm height cylinderical shell thickness not less than 6 mm and dish thickness not less than 8 mm) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required.
Providing, fixing, testing & commissioning of Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS: 12992 (Part 1).
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge (glycerin filled) with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. (Range 0-20 kg/cm2)
Supply, installation , testing & commissioning of male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with brass ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required. 25 mm dia
Providing, fixing, testing and commissioning of spring loaded relief valve suitable for pressure of 16 Kg / sq.cm with Body, cover of cast steel, stem-stainless steel 304, seat and seal -EPDM, Body seat ring , nuts and bolts of stainless steel and including gasket, gland packing, flanges conforming to IS 6392(PN 16) etc all as required to complete the system. 25 mm dia
Providing, fixing, testing and commissioning of Vortex inhibitors at suction line from fire tank to prevent Air entrapment and its resultant choking effect on full flow discharge and eliminating potential damage to booster pump equipment by preventing initiation of vortices within a tank when the contained liquid is being extracted and assists in maximizing effective tank capacity. The vortex plate shall be constructed of SS 316 coupled on MS pipe of thickness not less than 6 mm. the item includes painting, bends, etc all as required.
Providing & fixing of CI /forged brass body gate valves confirming to IS:778 class II with high tensile brass rising stem suitable for the system pressure 16 kg/ cm2 including & fitting etc complete as required.
65 mm dia
150 mm dia
Providing & fixing heavy duty double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required.
65 mm dia
80 mm dia
150 mm dia
200 mm dia
250 mm dia
a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Split casing, Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 55 m Head (FIRE WATER CURTAIN PUMP)
Providing and fixing of pressure switch of required range for suitable operation, Complete as required
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Split casing horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads b. Radisator cooled diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required. 2280 lpm at 55 m Head (FIRE WATER CURTAIN )
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects.All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing.
25 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of CI butterfly valve with temper switch of PN 24 rating with SS seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80mm dia
100 mm dia
150 mm dia
Providing , installation , testing and commissioning of non - return valve of following sizes confirming to IS:5312 complete with rubber gasket , GI bolts , nuts , washers etc. as required : 150 mm dia
Providing , installation , testing and commisssioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304 , sheet with 3 mm dia holes with stainless steel flange . 150 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia stainless steel valve (Grade-304) & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop stainless steel valve (Grade-304)& M.S. Pipe and socket. 30 meter
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with SS wire, rivets etc. conforming to IS 636 (type-A) as required Stainless steel (Grade 304)
Supplying & fixing 63 mm dia Stainless Steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia
Providing, fixing, testing & commissioning of standard firemans axe with heavy rubber handle.
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge with isolation ball valve suitable for rating 0 to 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
Providing, fixing, testing & commissioning of Fire Cabinet fabricated from 40 x 40 x 5 angle iron sections and 14 gauge CRCA sheet with full front glass door, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle, fire extingui & fire mans’ axe. The shutter shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 1.2 m (wide)x 0.6 m (deep). (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer).
Providing, fixing, testing & commissioning of GI air cushion tank on top of each riser fabricated from 6mm thick GI plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 6 mm thick GI plate with Air release valve & stop cock, flanged inlet connection with all accessories as required and conforming to IS 4736-1968. (The cushion tank should be suitable for rated working pressure.
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects.All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. GI `C' Heavy class pipe
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of CI butterfly valve with damper switch of PN 24 rating with SS seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
100 mm dia
150 mm dia
Supply, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) fo stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (inlet) 25mm NPT male thread to sprinkler head (Outlet ) 15mm NPT female thread with reducer nipple , 2 side brackets, center bracket , stockbar of following sizes complete as required. 1.5 M length
Providing & fixing flow switch in following size GI C Class pipe including connection etc as required . 150mm dia
Providing, fixing, testing & commissioning of Brass quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendant Sprinkler (68 degree) - K80 (15 mm) concealed type
Upright Sprinkler (68 degree) - K80 (15 mm)
Horizontal side wall sprinkler (68 degree) - K80 (15 mm)
Extended side wall sprinkler - K115 (20 mm)
High Temp. Sprinkler (141 degree) for Kitchen
Providing, installation, testing & commissioning of water curtain nozzle nickel chrome plated brass, BSPT, K-factor - 58, complete as required.
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia
Providing, fixing, testing & commissioning of inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly as per drawing. 50 mm dia
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge gyclerin filled with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS: 12992 (Part 1).
Supplying, installation, testing and commissioning of Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. if required as per Engineer in charge. Fire pipe brackets clamps,support and similar works.
Supply, testing commissioning of flow switch panel having 30 zone suitable for flow switch, complete as required
Supplying, installation, testing and commissioning of PVC insulated 2 core, 1.5 sq mm wire for flow switch to flow switch panel and temper switch of butterfly valve. Including GI cable tray and conduit. Complete in all respect.
Supplying, installation, testing and commissioning of panel suitable for damper switch of Butterfly valve , complete as required
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on SMPS 24 volts DC supply and connection pipe complete as required.
Supply, installation, testing commissioning of Deluge valve (to be used for water curtain) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong. complete as required 150 mm dia
Providing of UL listed pressure reducing valve on inlet & outlet, 1 No. UL listed pressure reducing valve with flanged connection, 2 Nos Pressure gauge on inlet & outlet. The complete system is tested to a pressure suitable to reduce the pressure upto 3.5 Kg/Sq.cm) Including flanges/ unions, nuts, bolts and washers complete as required. 150 mm dia
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). Providing & fixing ISI 15683:2018 marked portable CO2 type fire extinguisher type 4.5 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas & filled to a filling rate of not more than 0.667 and wall suspension bracket.
Providing & fixing of ABC Type MAP 90, Potable Fire Extinguisher, dry powder type (Stored pressure type) with cylinder initially fully charged with dry powder, ISI 15863:2018 marked complete with standard discharge valve with tube, CI bracket for wall mounting. 6Kg
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted.
9 Litres
50 Litres (trolley mounted)
Supply, installation, testing, and commissioning of automatic clean agent fire extinguisher of 5 kg capacity, ceiling-mounted type, with a mild steel body and pressure gauge, suitable for B and C classes of fire. The extinguisher must be refillable and include a gas release panel, safety release device, brass valve, and be fully charged with an HFC Blend. The system must include a pressure gauge to indicate the internal pressure, equipped with a squeeze grip lever and a tamper-proof seal to ensure functionality and safety.
Supplying and installing at approved location approved make fire buckets (6 No.) of 24 gauge galvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
Providing, laying, jointing (All pipes should be considered without welding. Pipes up to 2 inches shall have threaded joints & 65 mm dia. & above, grooved fittings & couplings for jointing shall be provided - - UL listed & FM approved and underground piping shall be DI pipe), testing and commissioning of following sizes of pipes 'C' class heavy duty GI pipe conforming to IS: 1239 with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, Structural Steel, hangers (using anchor fastners) as per specification (Modular Support). Providing two coats of synthetic enamel paint of approved shade over two coats of primer. GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects.All hangers, clamps, brackets, pipe Supports etc. shall be of modular type as per tender specification and the supply of the same shall also be included in rates under this head. Welding shall not be permitted. Grooved fittings shall be used for pipe jointing. Rates shall be inclusive of RCC pedestals at every 3 meters for above ground external fire piping..
80 mm dia nominal bore
100 mm dia nominal bore
150 mm dia nominal bore
Providing, laying, jointing, testing and commissioning of following sizes of pipes CENTRIFUGALLY DUCTILE IRON K-12 heavy duty with flanged joints with PN 40 flange as per IS: 8329, latest as on date with all accessories like all fittings, specials. Providing two coats of synthetic enamel paint of approved shade over two coats of primer. DI pipes running below ground shall not be less than 1.0 m below ground level at any point. Pipes shall embedded all round 150 mm thick compacted silver sand and protection to pipes and fitting by applying pypkote primer @ 100 gm/sqm). Thereafter wrapping 4 mm thick pypkote (AW4mm) protection coating by thermo fusion process. Overlap shall be maintained at 20 mm. The application shall be strictly as per specifications, complete in all respects. MS pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & two hours fire rated sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. 150 mm dia nominal diameter
Supplying and fixing of fire brigade connection of cast iron body with stainless streel male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia . CS pipe connection conforming to IS 904 as required :
2 way -100 mm dia GI Pipe
4 way -100 mm dia GI Pipe
Supplying, fixing, testing and commissioning of CI butterfly valve with damper switch of PN 2.4 rating with SS seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
80 mm dia
100 mm dia
150 mm dia
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Stainless Steel cap and chain as required :required: Single headed Stainless steel
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male female couplungs duly bound with SS wire , rivets etc.conforming to IS 636 (Type -A) as required: Stainless Steel (Grade 304 )
Supplying & fixing 63 mm dia SS short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304 )
Providing and laying Non Pressure NP-2 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cementmortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes.
Providing & fixing FRP cabinet with full front glass door and locking arrangement shade and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.75m x 0.25m)
Providing and fixing of SS fire brigade inlet hose coupling (draw-out connection) with nut for female coupling complete with 100 mm dia MS suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of MS drop pipe and foot valve shall be made in all the fire water static storage tanks (4 No) (MS pipe to be paid separately through appropriate item while cost of foot valve to be included).
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia
Providing and fixing of dial type (100 mm) pressure gauge glycerin filled with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
Providing and fixing weather proof lockable cabinet of size not less than 0.9 x 0.6 x 0.45 mtr made out of CARA sheet of 14 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of stove enamel paint of approved shade. (The aesthetics and design of the cabinet shall be as per the architect / Client).
Supplying, installation, testing and commissioning of pre-engineerec Automatic Clean Agent FM200 (UL & FM Listed/, Direct Low Pressure (DLP) System complete With DOT & PESO approved cylinder fitted with Automatic Valve. Complete System shall be Tested and Certified to LPCB/VDS.
Supply, installation, testing and commissioning of 5 LBS. FM200 DLP Assembly with automatic valve mounted on DOT & PESO approved cylinder, push in connector for tube, Mounting bracket etc.
Supply, installation, testing and commissioning of UL listed Linear Pneumatic Heat Detection Tube (operating temp at 120 Degree Centigrade, Colour-Red) For Automatic Fire Detection & Suppression. (Fittings not included)
Supply, installation, testing and commissioning of TEE connection (4/6mm) with double sealant. Tee shall be of brass with nickel Coating (Temp:- 50 to 80 degree)
Supply, installation, testing and commissioning of pressure switch (UL approved)
Supply, installation, testing and commissioning of Pressure Gauge (UL approved) at the end of line
Supply, installation, testing and commissioning of End line adapter (double sealant)
Supply, installation, testing and commissioning of End plug for the tube
Supply, installation, testing and commissioning of Master control Unit with LED Flasher, Electronic Hooter, LED Indicator with provision for Integration with Fire Alarm
Gas Suppression System UL/FM Approved:- CCOE approved High pressure seamless BIS 7285 pt2 approved Cylinders , UL/FM approved based Inert gas clean agent having zero ODP & GWP < 1, stored pressurized system with PESO approved valve assembly . The system also to be fitted with digital pressure guage having real time algorithm of temperature and pressure , pressure supervisory switch, mounting bracket, container straps, NRV. Electrical control head for all master cylinder, Pressure operated control head for all slave cylinder which shall allow for pressure actuation , manually operated actuator on top of electric control head to actuate the gas flooding of respective room bank with the help of a lever, flexible rubber hose with wire bralded enforcment to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold to route the gas from the storage cyinder to the discharge piping, , Nozzle complete as required. On any displacement of solenoid valve, Solenoid of electrical control head shall be able to notify the fault by audio/visual mean. The real time system report with respect to its condition of Healthy, fault or any leakage can be directly ( without any medium of fire alarm or BMS ) and icloud based remotely monitored. Designated to provide proper flow rate & distribution Inert gas gas to flood the hazard area as per latest NFPA 2001. 'Extinguishing Agent shall be: The agent shall not contain any Hydro fluorocarbons (HFC). The ozone depletion potential should be zero. The Global warming potential should be equal to or less than 1 The supplier should be at least 10 years old manufacturer of this clean agent. The Extinguishing Agent should be UL Listed/ FM approved. The extinguishing agent should be filled in an UL Listed and PESO approved filling station. The extinguishing agent must come with warrantee of 20 years against regulatory bans. 'The system shall sustain upto 65oC operating temperature. filling facility shall be in India and shall be UL approved.The complete gas suppression system shall be UL/FM approved. As system is UL/FM approved , the software for calculation used to be UL/FM approved. The documentary evidence to be provided for all approval during the time of bidding. 'Fire Alarm System with respect to Room size automatic addressable fire alarm system should consist of addressable fire panel , addressable multicrieteria detector, Manual release switch, Manual abort switch, sounder cum strobe, response indicator and ow Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire Armouring, solid copper conducter cable approved by LPCB. UL Listed / FM approved/IS 2189
Kitchen Suppression System Cylinder with Valve:- Supply, installation, testing and commissioning of pre-engineered wet chemical restaurant fire suppression system as defined by NFPA-17A standard for Wet Chemical Extinguishing Systems. The system shall be designed to protect commercial restaurant cooking appliances, hoods and ducts. The Kitchen Mister fire suppression system shall be UL listed. Based on class K fire looking into grease laden fires the Extinguishing agent shall be potassium carbonate. The system capacity shall be self suffcient to extinguish the fire. The cylinder shall be in DOT 4BW240. The system stored pressure shall be of 195psi@70 Farenheit. The valve shall consist of detect pin so that on discharge, it would lock the valve assuring full discharge. System Actuation Mechanism:- Supply, installation, testing and commissioning of System Releasing Module type control head. The construction of release module shall be fully mechanical and would be connected directly or remotely to the system valve for system actuation. It shall consisit of at least 2 NO/NC contact for interfacing of system with Fire alarm Panel /Damper /Electrical shut down of appliances. The System release module shall be equipped with auctuation pin reset tool. Manual Pull station :- Supply, installation, testing and commissioning of Remote Pull station with junction box. The remote pull station shall be installed near kitchen exit. The construction of Remote Pull station shall be fully mechanical and would be used for remote actuation of system .The cable for connecting Remote pull station shall be shielded. In any condition Bare cable with conduit shall not be used. Detection System :- Supply, installation, testing and commissioning of special alloy Fusible link along with its holder & bracket with fittings such as corner pulley . The fusible link on detection shall release tension to actuate/signal single release module for system dicharge. The fusible link holder shall be used to maintain continuity of detection line with the help of sheilded cable. Corner pulley adaptor shall be used for detection line at entry of each hood. Discharge Nozzles: Supply, installation, testing and commissioning of Nozzle. The nozzle shall be with blow off cap . The nozzle shall be mist type and shall be specifically developed for appliances, duct and plenum application. In order to distinguish nozzle visually , it shall have unique colour band .The Nozzle prior to installation to pipe shall be install with swivel adaptor to facilitate the aimming of Nozzle with respect to cooking appliances. Inorder to install the Nozzle the at every SS pipe entry to hood shall be with hood Quickseals.With reference to NFPA 96 Standard for Ventilation Control and fire protection of commercial cooking operations all hood penetrations shall be sealed by a liquid-tight, continuous external weld or a Listed mechanical device providing a liquid-tight seal. System Interconnecting Cable: Supply, installation, testing and commissioning of Shielded Cable with necessary interface and wire crimps. In order to connect detection unit , Gas shut off valve, remote pull station to control release module shielded cable of stainless steel cable dia 1/16" shall be used. Gas Shutoff Valve :- Supply, installation, testing and commissioning of Mechanical Gas Shutoff Valve. Inorder to cut the fuel source of fire gas shut off valve of 1" shall be used in gas pipe line. The construction of Gas shut off valve shall be fully Mechanical . In no manner it shall require any electric power sourse of energy to operate. Piping :- Supply, installation, testing and commissioning of Stainless steel 3/8'' seamless pipe of schedule 40 along with fittings for transportation of extinguishing agent from cylider to hood on actuation of system. Hood Name/dimension (L X W)
1200mm X 900mm
1000mm X 900mm
750mm X 900mm
1050mm X 1050mm
1650mm X 1050mm
6000mm X 2200mm
2700mm X 900mm
1500mm X 900mm
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying, installation, testing & commissioning of digital audio amplifier 200 Watt, 25V rms operating at 240 Volt AC Supply complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supplying, installation, testing & commissioning of intelligent multisensor detector with rate of rise cum fixed tempreature thermistor complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing & Commissioning of addressable monitor module complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . . (For monitoring of AHU's, VRV,sprinkler flow switch, Developer's fire panel, WLD Panel)
Supply, installation, testing & Commissioning of Relay module (For integartion with PA and other security system) complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supplying following 1.1kV grade, suitably insulated, Fire survival circuit integrity, heavy duty copper armoured cables, confirming to IS : 17505 & suitable for 415V, 50Hz, AC system, galvanised steel armouring (round (W) or flat (F) as mentioned) and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
2C X 1.5 Sqmm
ELECTRICAL WORKS (Refer to 'Electrical BOQ Annexure' for the detailed item specifications, before quoting the rates) HT PANELS MAIN HT PANEL WITH (2# I/C + 5# O/G + 1#B/C) Supplying, installation, testing and commissioning of HT Panel with following components and accessories including those mentioned in tender specifications,SLD and complete as required., GENERAL , Voltage Rating-11 kV, SCADA compatibility-Yes, DC Supply-Existing Battery Charger, Internal arc tested for-1s, HT Capacitors tied -No-, Control Voltage-110V dc, Fabrication Material-High grade CRCA/Alu Zinc(Body shall be corrosion proof), Thickness-2mm or as per corrosion proof design, MFM provided in the HT Panel should require TOD functionality (If not available, TOD meters shall be provided to I/C's and O/Gs's., INCOMER, Switching Device-2Each Voltage Rating :11 kV, Breaking Medium :VCB, 3P, Type :Drawout- Roll on floor, Min Ampere Rating :630A, Min S.C Rating : 18.3 kA, for 3 sec, Breaker Trolley: Yes, Earthing with : Earth Truck, Operation :Motorised, Relay and Protections-2Each, Note : Numeric relay modules with multiple protection fuctions are also acceptable. However for special protections like 63T & 64R etc separate numeric relay modules shall be provided. Relay : Numeric-Feeder Undervoltage (27)----- / Relay : NumericFeeder Overvoltage (59)----- / Relay : NumericFeeder Instantaneous Overcurrent (50) CT required :400/1A, 15VA, 5P20 / Relay : NumericFeeder Instantaneous Earth Fault (50N) CT required :400/1A, 15VA, 5P20 / Relay : NumericFeeder IDMT Overcurrent (51) CT required :400/1A, 15VA, 5P20 / Relay : NumericFeeder IDMT Earth Fault (51N) CT required :400/1A, 15VA, 5P20 / Relay : NumericFeeder Phase sequence (47N) CT required :400/1A, 15VA, 5P20 / Relay : NumericFeeder Frequency (81) CT required :400/1A, 15VA, 5P20 / Relay : Electromechanical , Feeder Lockout (86) (with electrical reset) CT required :400/1A, 15VA, 5P20 Relay : Numeric , Feeder Trip Circuit Supervision (95) CT required :400/1A, 15VA, 5P20 / Indication Lamp / Phase Indication :2Set / On, Off, Trip :2Set / Spring Charge :2Set,/ Test / Service :2Set / Trip Circuit Healthy :2Set DC Fail :2Set / Earthing Device In :2Set / Metering / Multifunction meter (Class 0.5s) with RS485 communication port with CTs (resin cast) (3nos) with ratio 400/1A of 15 VA burden and accuracy class –0.2s : 2 set (for Incomer-01 & 02) Others / ANN(16 Window) :2Set / Hooter(90db) :2Set / Emergency Push :2Set / Mimic Diagram with indicaions :2Set Surge Arrester -2Each / 9kV,5kA-Metal oxide varistor type surge arrestor suitable for both lightning and switching surges,complete with its bushings and earthing terminations etc. as required. Line PT-2Each / Burden : 50VA / PT Ratio :11 kV/ √3:110V/ √3, PT type : Withdrawable, Secondary Protection :Fusealong with fuse failure relay Connection : Y-Y (NG) Core-1:Metering Class : CL-0.2S Core-2 :Protection Class : CL-3P Primary Side FuseInbuilt :11 kV, 3Nos. BUSBAR "Note : Each Bus section shall be provided with a Bus PT. Bus PT shall have same configuration as incoming line PT. Analogue voltmeter shall be provided with Bus PT alongwith phase indication lam5P20. Buscoupler shall have same configuration as Incoming switchgear. However it shall not be provided with meters." Material-Cu with tinned plating Contineous current carrying capacity (after all derations)-630A S.C current carrying capacity (after all derations)-18.3 kA Bus PT-Yes Bus Coupler-Yes OUTGOINGS Switching Device-5Each Voltage Rating :11 kV Breaking Medium :VCB, 3P Type :Drawout- Roll on floor Min Ampere Rating :630A Min S.C Rating :18.3 kA for 3 sec Breaker Trolley: Yes Earthing :Earth Truck Operation :Motorised Relay and Protections-5Each Note : Numeric relay modules with multiple protection fuctions are also acceptable Relay : Numeric , -Feeder Undervoltage (27)----- Relay : NumericFeeder Overvoltage (59)----- Relay : NumericFeeder Instantaneous Overcurrent (150) CT required :150/1A, 10VA, 5P20 Relay : NumericFeeder Instantaneous Earth Fault (150N) CT required :150/1A, 10VA, 5P20 Relay : NumericFeeder IDMT Overcurrent (51) CT required :150/1A, 10VA, 5P20 Relay : NumericFeeder IDMT Earth Fault (51N) CT required :150/1A, 10VA, 5P20 Relay : Numeric , Feeder Phase sequence (47) CT required :150/1A, 10VA, 5P20 Relay : Numeric , Feeder Frequency (81) CT required :150/1A, 10VA, 5P20 Relay : Electromechanical , Feeder Lockout (86)(with electrical reset) CT required :150/1A, 10VA, 5P20 Relay : NumericFeeder Trip Circuit Supervision (95) CT required :150/1A, 10VA, 5P20 Relay : NumericTransformer Sudden Pressure CT required :150/1A, 10VA, 5P20 Relay : NumericSpecial Restricted Earth Fault (64R) CT required :150/1A, 10VA, PS Indication Lamp Phase Indication :5Set On, Off, Trip :5Set Spring Charge :5Set Test / Service :5Set Trip Circuit Healthy :5Set DC Fail :5Set Earthing Device In :5Set Metering HT TOD meter with RS485 communication port with CTs (resin cast) with ratio 150/1A of 10 VA burden and accuracy class –0.2s : 5 nos Others ANN(8 Window) -5Set Hooter(90db)-5Set Emergency Push-5Set Mimic Diagram with indicaions-5Set "The following operations of the HT Panel shall be performed through SCADA: 1. I/C- ON, OFF & RESET 2.O/G's (F-01 to F-05) ON, OFF & RESET The following status parameters of the HT Panel shall be monitored through SCADA: 1. I/C- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 2.O/G-01- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE 3.O/G-02- ON, OFF, TRIP, LOC/REMOTE, SPRING CHARGE " "The following parameters from the numerical relays shall be monitored through SCADA: 1. I/C- Num relay operated on Earth Fault, Ovr crt, Short Ckt 2. O/G's (F-01 to F-05) - Num relay operated on Earth Fault, Ovr crt, Short Ckt The following parameters from all TOD meters & kWH meteres shall be monitored through SCADA: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All equipment (FRTU, N/W switches etc), Optic Fibre Cables, control wiring and other accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost"
TRANSFORMERS Supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50HZ, AC supply, Dyn 11 vector group, core made of good quality CRGO, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned in BOQ, specifications and SLD and complete as required. Power Rating-2500 kVA Percentage Impedance-6.25% Tolerance-As per IS Duty-Contineous Indoor Type-Dry-CRT Level 2 Cooling Type-AN Turn Ratio-11/0.433 kV Losses as per- latest ECBC Insulation - Class-F Tap Changing Arrangement-On Load - "+5% to -15% in the steps of 2.5" having manual/ motorized controls with Digital AVR and communicative interface for SCADARTCC Required-Yes Termination box with disconnecting facility on HV side suitable for-11 kV(E) 3C x 300 sqmm XLPE Cable Termination box with disconnecting facility on LV side suitable for-4000A, FP, 65kA Sandwich busduct Neutral CT-800/1A, CL-PS, 15VA Bi directional rollers Earthing terminals. Winding temperature indicator. (WTI) Rating and diagram plate. Marshalling box with watertight lockable cover lid and all associated accessories as per schedules and specifications. SCADA Operations: The operations of the RTCC panel shall be performed through SCADA. The following status parameters of the Transformer & RTCC shall be monitored through SCADA: 1. Winding Temperature 2. Alarm and Trip Status for Winding Temperature, Bucholz Relay etc. 3. Tap Position
1500kVA DG Set
500kVA DG Set
HT CABLE
Laying of one number XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ CABLE TRAY/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonary open duct as required. Above 120 sq. mm and upto 400 sq. mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm
Supplying 11KV (Earthed) grade, XLPE insulated, heavy duty, aluminium, FRLS type, armoured cables suitable for 11kV, 50Hz, AC system with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel flat armouring and with all components as mentioned in BOQ, specifications and SLD, complete as required. 3 core x 300 sq. mm
LT CABLE, LAYING & TERMINATIONS Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95sq.mm and upto 185sq.mm (clamped with 25/40x3mm MS flat clamp)
Above 185sq.mm and upto 400sq.mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC insulated and PVC sheathed / XLPE cable of 1.1 KV grade complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Note : For copper cables cu lugs shall be used and Al lugs shall be used for Al cables.
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
Supply of following XLPE insulated, sheathed HFFR aluminium conductor(A2XFY), 1.1 kV grade, armoured cable confirming to IS:7098, HFFR insulation confirming to IS:17048 and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
3.5C X 300 Sqmm
3.5C X 240 Sqmm
3.5C X 185 Sqmm
3.5C X 120 Sqmm
3.5C X 95 Sqmm
3.5C X 70 Sqmm
3.5C X 50 Sqmm
3.5C X 35 Sqmm
4C X 25 Sqmm
3C X 300 Sqmm
3C X 35 Sqmm
Supply of following XLPE insulated,sheathed HFFR copper conductor(2XWY), 1.1 kV grade armoured cable confirming to IS:7098, HFFR insulation confirming to IS:17048 and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
4C X 16 Sqmm
4C X 10 Sqmm
4C X 6 Sqmm
3C X 10 Sqmm
3C X 6 Sqmm
Supplying of following sizes PVC Insulated & extruded PVC sheathed copper conductor armoured (GS wire armoured)control cable of 1.1 KV grade ISI marked complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
2C x 2.5 sqmm
4C x 2.5 sqmm
6C x 2.5 sqmm
19C x 2.5 sqmm
21C x 2.5 sqmm
Laying of following sizes PVC Insulated & extruded PVC sheathed copper conductor armoured (GS wire armoured)control cable of 1.1 KV grade ISI marked complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
2C x 2.5 sqmm
4C x 2.5 sqmm
6C x 2.5 sqmm
19C x 2.5 sqmm
21C x 2.5 sqmm
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC Insulated & extruded PVC sheathed copper conductor armoured (GS wire armoured)control cable of 1.1 KV grade ISI marked complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Note : For copper cables cu lugs shall be used and Al lugs shall be used for Al cables.
2C x 2.5 sqmm
4C x 2.5 sqmm
6C x 2.5 sqmm
19C x 2.5 sqmm
21C x 2.5 sqmm
Supplying of following sizes PVC Insulated & extruded PVC shielded copper conductor armoured (GS wire armoured)control cable of 1.1 KV grade ISI marked complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
2C x 2.5 sqmm
4C x 2.5 sqmm
Laying of following sizes PVC Insulated & extruded PVC shielded copper conductor armoured (GS wire armoured)control cable of 1.1 KV grade ISI marked complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
2C x 2.5 sqmm
4C x 2.5 sqmm
Supplying following 1.1kV grade, suitably insulated, Fire survival circuit integrity, heavy duty Aluminium/copper armoured cables, confirming to IS : 17505 & suitable for 415V, 50Hz, AC system, galvanised steel armouring (round (W) or flat (F) as mentioned) and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
3.5C X 300 Sqmm Al.
3.5C X 185 Sqmm Al.
3.5C X 95 Sqmm Al.
3.5C X 70 Sqmm Al.
3.5C X 50 Sqmm Al.
3.5C X 35 Sqmm Al.
4C X 25 Sqmm Al.
4C X 16 Sqmm Cu.
4C X 10 Sqmm Cu.
4C X 4 Sqmm Cu.
3C X 10 Sqmm Cu.
3C X 6 Sqmm Cu.
3C X 4 Sqmm Cu.
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC insulated and PVC sheathed / XLPE cable of 1.1 KV grade complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Note : For copper cables cu lugs shall be used and Al lugs shall be used for Al cables.
4C X 6 Sqmm.
3C X 6 Sqmm.
Supplying and making end termination with brass compression Flameproof gland and Aluminium/Copper Flameproof lugs for following size of PVC insulated and PVC sheathed / Fire Survival cable of 1.1 KV grade complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
3.5C X 300 Sqmm Al.
3.5C X 185 Sqmm Al.
3.5C X 95 Sqmm Al.
3.5C X 70 Sqmm Al.
3.5C X 50 Sqmm Al.
3.5C X 35 Sqmm Al.
4C X 25 Sqmm Al.
4C X 16 Sqmm Cu.
4C X 10 Sqmm Cu.
4C X 4 Sqmm Cu.
3C X 10 Sqmm Cu.
3C X 6 Sqmm Cu.
3C X 4 Sqmm Cu.
2C X 1.5 Sqmm Cu.
Supply, installation, testing & commissioning of 4 Core 1 Sqmm Signal/Sensing cable for Dual source Meter and DG complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC insulated and PVC sheathed / XLPE cable of 1.1 KV grade complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Note : For copper cables cu lugs shall be used and Al lugs shall be used for Al cables.
4C X 1 Sqmm
CABLE TRAYS & RACEWAYS Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, installation, testing and commissioning of G.I. floor raceway of mention below sizes including all necessary civil works.complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of G.I. junction box for duct along with SS cover plate finsihing for junction box (frame & trap) including all necessary civil works.complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with 2 hours Fire rating Capacity.
600 mm width X 62.5 mm depth X 2.0 mm thickness
BUSDUCT & RISING MAIN Supplying, installing by suspension on ceiling, testing, commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. Clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc.complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
630 A 50kA SC for 1 sec
800 A 50kA SC for 1 sec
1600A, 50kA SC for 1 sec
2000 A 50kA SC for 1 sec
2500A 50kA SC for 1 sec
4000A 50kA SC for 1 sec
Supply, installation, testing & commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. Clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . 4000A 65kA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Compact Sandwich Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with MCCB / ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required:
630A, FP ACB, 50kA SC for 1 sec
2000A, FP ACB, 50kA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity PlugIn / tapoff box on the existing Compact Sandwich Type bus trunking / rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB / ACB complete etc. as required
100A, 36kA SC for 1 sec
160A, 36kA SC for 1 sec
200A, 36kA SC for 1 sec
250A, 36kA SC for 1 sec
400A, 36kA SC for 1 sec
EARTHING Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm Cu strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply, installation, testing and commissioning of 75 mm X 10 mm GI strip on surface or in recess for connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of 75 mm X 5 mm CU. strip on surface or in recess for connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of 75 mm X 5 mm GI strip on surface or in recess for connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of 50 mm X 5 mm GI. strip on surface or in recess for connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . .
Supply, installation, testing and commissioning of earth bus of 40 mm X 5 mm GI strip on surface for connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of 2mm thick MS painted sheet metal enclosed 300 x 200 x 150 (D) mm insulated earth box with 1 nos. 50 x 6 mm copper tinned earth bars on SMC insulator with perforation suitable for 12-15 nos connections complete with all fixing accessories etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of Maintenance Free Earthing System consisting of : a. UL Listed 25 mm dia. Copper bonded carbon steel core Electrode tested according to IEC 62561-2. b. SS Universal Clamp of Size 175X50X3 mm for Connection Terminal. c. Earth enhancing compound(OEC) tested as per IEC 62561-7 d. Heavy duty RCC Pit cover electrode shall be CPRI tested 'UL' Listed copper bonded carbon steel core electrode of 25 mm dia each With a minimum coating thickness of 250 microns and length of 3 meters. Required amount of earth enhancing compound needs to be considered to fill the 100mm augered hole surrounding to the electrode. The rate shall include excavation of earth, filling with back fill compound, and earth pit marking in all kind of soils complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
UPS Supplying,Installation, testing and commissioning of online double conversion fully microprocessor based ,indoor type, compact UPS system of following rating with IGBT based PWM technology to achieve THD < 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz , inbuilt isolation transformer(K13 copper wound), necessary VRLA (SMF) batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for UPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP computability for operation and monitoring etc. with all components as mentioned in BOQ, specifications,complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing.
60 kVA - (With batteries) (Parallel Operations)
LIGHTNING PROTECTION SYSTEM Note : Structural Earthing Shall Be Done Air Terminal Parallel Connectors for (700MM Air Terminal)connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard EN 62561-1.
Air Terminal Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2.,
Air-termination rod having length- 2500 mm, of Material- AlMgSi, of Diameter Ø 16 / 10 mm, chamfered on both ends, & Complied as per Standard EN 62561-2.
FS clamp for air-termination rods, 16 mm, Al, FS clamps for connecting air-termination rods to conductors with truss head screw, plate, nut and double clamp, Material of clamp: Al, Clamping range of air-termination rod: 16 mm, Clamping range Rd: 2x 8-10 mm & Material of plate: StSt.
For protecting the roofing sheets under the concrete base(17 kg.). The Diameter Ø outside 370 mm, Diameter Ø inside 360 mm and Material EVA with wedge clamp with wedge clamp
Concrete base for air-termination rods, for self-supporting air-termination rods in the tripod. Support Wedge- Ø16 mm, Diameter- Ø 337 mm, Material- concrete, Material of wedge- StSt & Weight 17kg.
Universal connector of Material- StSt, with clamping range- 8-10mm, with truss head screw M10x35 mm & Complied as per Standard EN 62561-1.,
Roof Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2.
Roof conductor holder FB2 for flat roofs with concrete block C35/45 with double conductor holder Rd 8 mm fixed.
Conductor holder for Parapet wall/Side wall of Material- StSt, for Rd 8-10 mm Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories Screw and Gitty, Material SS (M5 x 50mm)
Fixed earth-termination system for protective equipotential bonding and functional equipotential bonding of the down. Connection thread M10 / M12, material of plate-StSt,material of axis- Stst, having connection plate Ø 80 mm & Complied as per Standard EN 62561-1.
Clamps to connect reinforcing steel mesh or reinforcement with round and flat conductors. of material- St/bare, having clamping range- Rd / Rd 6-22 / 6-10 mm, Clamping range- Rd / Fl 6-22 / 40 mm & Complied as per Standard EN 62561-1.
Connection clamps with threaded bolt for connecting round and flat conductors to fixed earthing terminals with M10 / 12 thread. Also suitable for installation on the rear side of the fixed earthing terminal without connecting shaft, e.g. for use with flat strip. Light design, with M10 connection thread.
Down Conductor Fixed earth-termination system for protective equipotential bonding and functional equipotential bonding of the down. Connection thread M10 / M12, material of plate-StSt,material of axis- Stst, having connection plate Ø 80 mm & Complied as per Standard EN 62561-1.
Clamps to connect reinforcing steel mesh or reinforcement with round and flat conductors. of material- St/bare, having clamping range- Rd / Rd 6-22 / 6-10 mm, Clamping range- Rd / Fl 6-22 / 40 mm & Complied as per Standard EN 62561-1.
Connection clamps with threaded bolt for connecting round and flat conductors to fixed earthing terminals with M10 / 12 thread. Also suitable for installation on the rear side of the fixed earthing terminal without connecting shaft, e.g. for use with flat strip. Light design, with M10 connection thread.
Down Conductor of Diameter Ø- 10 mm, Material- Stainless Steel round conductor
Maxi multipurpose connecting clamp according to EN 62561-1, for universal use as a cross clamp, T clamp, and parallel clamp for connecting reinforcing bars or earth rods. Three-piece with hexagon screw and thread in the base part.
Universal connector of Material- StSt, with clamping range- 8-10mm, with truss head screw M10x35 mm & Complied as per Standard EN 62561-1. (Cross & Straight joints)
Earthing Down Conductor of Diameter Ø- 10 mm, Material- Stainless Steel round conductor
Universal connector of Material- StSt, with clamping range- 8-10mm, with truss head screw M10x35 mm & Complied as per Standard EN 62561-1.,
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 100mm. Made of petrolatum- coated chemical fibre fabric.
WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of pvc conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of Steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but exclusing modular plate etc as required
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying,installation,testing amd commissioning of Passive infrared(PIR) technology based occupancy sensor having high preformance,non regulating programmable type,suitable for connected load upto 10Amp,for mounting height up to 2.8 mtr.and for 5m diameter coverage area along with necesaary fixing arrangements i/c programming at site etc.complete as required.
Supplying,installation,testing amd commissioning of Passive infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.)having high preformance,regulating programmable type,suitable for connected load upto 10Amp,for mounting height up to 2.8 mtr.and for 5m diameter coverage area along with necesaary fixing arrangements i/c programming at site etc.complete as required.
Supplying installation testing & commissioning of Black painted Extruded aluminium housing. Green / Red LED’s mounted inside the housing. Laser engraved Signage matter on Single / Double Acrylic sheet fixed on one side Suitable for wall / ceiling / suspension type single / double sided display. In double sided version black paper is inserted. Ni-Cd Battery back up to 2 hrs. (Charged up to 8 - 10 Hrs).Mounting strings provided for pendent mounting Operating Voltage 150-280V AC Ambient operating temperature. – 0 to 450C Ingress protection – IP42.Including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. Up to suitable point complete as required. 220208 BESL 03 LED SSD WBB GREEN 240 3 8W OR 220209 BESL 03 LED SSD WBB RED 240 3 8W OR 220210 BESL 03 LED DSD WBB GREEN 240 3 8W OR 220211 BESL 03 LED DSD WBB RED 240 3 8W
Supply, Installation, Testing & Commissioning of medium intensity LED aviation light confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supplying and fixing of following industrial type, IP-42, 240V single phase, 50Hz, (2P+E) power point with plug cover suitable for industrial type plug tops complete with all accessories as requied.
32A Industrial power point
63A Industrial power point
Supplying and fixing of following industrial type, IP-42, 415V three phase, 50Hz, (3P+2E) power point with plug cover suitable for industrial type plug tops complete with all accessories as requied.
32A Industrial power point
63A Industrial power point
Supply, Installation, testing & Commissioning of Modular switch and socket with finish and color as per architect and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
DISTRIBUTIONS BOARD Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, triple pole, TPN, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Supplying and fixing of following rating, ,415/ 240 V, earth leakage circuit breaker (ELCB) having a sensitivity current 100mA/300mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A, TPN ELCB, 100mA
63A, TPN ELCB, 300mA
40A, DP ELCB, 100mA
40A, DP ELCB, 300mA
Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of Final Distribution boards made out of pre-treated and powder coated 1.2mm sheet steel and glazed steel door in double door enclosure with MCB's / ELCB's mounted on din channel, insulated prong bus bars rated for 100A and with separate neutral and earth terminals and in 1,2,3 & 4 pole versions as asked for or as required along with the cable end boxes on all sides of the DB's as per the requirement or Cup-board layout suggested by Architect/ Consultant.complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
8WAY VTPN DB Incomer: 1 No. 125A 4P MCCB, 25KA Outgoing: 8 Nos. TP MCB's or 24 Nos. SP MCB's or combination of both upto total 24 modules of rating 10A/16A/20A/25A/32A/40A/63A
12WAY VTPN DB Incomer: 1 No. 160A 4P MCCB, 25KA Outgoing: 12 Nos. TP MCB's or 24 Nos. SP MCB's or combination of both upto total 24 modules of rating 10A/16A/20A/25A/32A/40A/63A
CIVIL & MISC. WORKS Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100 mm dia
150 mm dia
250 mm dia
300 mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Filling available excavated earth(excluding rock) in trenches,sides of foundations etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 meters.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width,and lift upto 1.5 metres,including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. Cable & Pipe Sealing arrangement to stop water penetration/Fire penetration
Supply and installation of Cable sleeves for sealing of Cable & pipe openings through retaining & partition wall ( such as core cut, sleeves and Trench) to stop water and fire penetration . The Seal must be circular type and shall be tested for rat bite with (Protective rate 0.7), termite proof (Decay Level 1) & age tested at 200° for 24Hrs, Sound insulation up to 54dB from recognized testing institutes. The seal must have Fire protection of 60min from recognized testing institutes as per National & international standards. The seal must have been tested for RADON gas tightness with 95% Efficiency, Salt Spray test certification/report of 28days for all metal parts of the seal.The seal made of SS 304 grade pressure plate, nut, bolts & EPDM rubber (halogen free) & low-smoke index rubber & must have rubber Shore hardness A 55±5°.Tightness according to FHRK test regulations OR equivalent National & international standards from recognized testing institutes.
Technical Details: Sleeve: FUFZ -Fibre reinforced concrete -Asbestos free. Dimensions: Seal width: 40 mm Wall Thickness : 200mm -300mm Load case:Pressing Water Tightness: Gastight and watertight Approval/Test report by LGA: Water tight pressure test for upto 5 bar Material: EPDM (55+-5 Shore A) V2A (EN 1.4301/AISI 304)
Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
Supplying, installation, testing and commissioning of Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Cable tray,support and similar works. Clamps,support and similar works.
Cutting of RCC/PCC of any grade using cutting machine/core cutting machine complete in all respect at locations as directed .(Prior approval required for execution of this item) (after cutting breaking and disposal of concrete to be paid under seperate item).
upto 100 mm depth
upto 200 mm depth
upto 300 mm depth
Providing & fixing in position 1000 mm wide , Electrical Insulating Polymer Mats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV, fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)
Providing & fixing in position 1000 mm wide , Electrical Insulating Polymer Mats as per IS 15652:2006, 2.5 mm thick, suitable up to 11 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip, marking on top)
Supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 Sq Metre )
Supply of Red cross, approved first aid kit complete as required.
Supplying and installing at approved location approved make fire buckets (6 No.) of 24 gauge galvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
Surface preparation: The concrete substrate must be sound and of sufficient compressive strength (minimum 20 N/mm2) with a minimum pull off strength of 1.5 N/mm2 for durable and lasting flooring. The substrate must be level, clean, dry and free of all contaminants such as dirt, oil, grease etc. Moisture content in the concrete must be below 4%. Concrete substrates must be prepared mechanically using abrasive blast cleaning, scarifying or grinding equipment to remove cement laitance and achieve an open textured surface. Weak concrete must be removed and surface defects such as blowholes and voids must be fully exposed.Repairs to the substrate, filling of blowholes/voids and surface leveling must be carried out using appropriate repair product. The concrete or screed substrate has to be primed or leveled in order to achieve an even surface. High spots must be removed by grinding.
Providing and installing 2mm thick Di-Electric flooring (ERDA Certified) for high build, High Breakdown Voltage using FloArm SL Di-Electric - 4 component material with outstanding wearing properties, self levelling, high electric & insulation properties. Applying FloArm Primer 1290 @ 200 - 300 g/sqm over prepared surface and allowing to dry. Mixing 4 components of Di-electric flooring by mechanical means @ 2mm thickness, spreading and finishing the mixed FloArm SL Di-Electric over completely dried screed, etc and complete as per manufacturer's specification. Incase of undulation in concrete surface additional self levelling epoxy screed is to be applied to maintain the level & top coat thickbess @ 2mm which will be a separate item. The parameters for Di-Electric flooring are as follows: 1) Shore D hardness After 7 Days at 30DegC(ASTM D 2240)- 70 - 80, 2) Compressive strength After 7 days (IS 9162)- > 60N/mm2 @ 30DegC, 3) Flexural Strength After 7 days (IS 9162) ->40 N/mm2 @ 30DegC, 4) Tensile Strength After 7 days (IS 9162) ->20N/mm2 @ 30DegC, 5) Bond strength @ 7 days at +27°C (ASTM D4541-95) >1.5 N/mm2 (concrete failure) 6) Insulation resistance @ 500 V, coating thickness: 5 mm (ASTM D 257-14) Average 2x10^6 M Ω 7) Breakdown voltage, KV @ coating thickness: 2 mm (IS 2584) 33.5 KV 8) AC proof Voltage @ 22 KVA for 3 minutes (IS 2584) : Withstood 9) Leakage Current @ 22 KV (IS 2584) < 0.09mA 10) Taber abrasion resistance (1000 g, 1000cycles) (ASTMD4060) 80 mg, weight loss
SCADA SYSTEM (Supervisory Control and Data Acquisition System) Design, engineering, supply, installation, testing, and commissioning of a complete SCADA system for monitoring and control of the entire Electrical system, including associated 11kV, 0.415kV Panels, RMU, DG sets,Transformer and associated distribution systems. The SCADA system shall include all necessary hardware and software for seamless operation and future scalability. Functional Requirements: Real-time data acquisition and control of electrical panels (HT & LT), transformers, DG sets, etc. (The parameters to be monitored and controlled are separately detailed in the respective BOQ descriptions for HT panels, LT panels, RMUs, etc.) Associated Cabling and Network components (including Supply and laying of Network/ OFC cables, Network Swithces & Active devices, FRTU, modifications required in the Panels etc shal be under the scope of this job without any additional cost/ extra items. Direct communication with: Numerical relays for protection and control status. Digital power analyzers for energy and power quality data. Time synchronization using a GPS-based Real-Time Clock (RTC) system. Fully compatible with IEC 61850/IEC 60870-5-104 communication protocols and supporting Modbus/RS-485/RS-232 conversions. System Configuration: Hot-standby SCADA workstations (2 Nos.) with dual-monitor setup and licensed SCADA software. Industrial-grade managed Ethernet switches with fiber optic uplink ports for redundancy and network reliability. Required RS-485/RS-232 to Ethernet converters and intelligent protocol multiplexers. High-speed data connectors and shielded communication cables for interconnection between all relevant control and monitoring devices Accessories and Peripheral Devices: Online UPS (1 No.) – 1 kVA capacity with a minimum 1-hour backup for SCADA servers and communication equipment Color Laser Printer (1 No.) – for report generation and SCADA system printouts Color Inkjet Printer (1 No.) – for general-purpose and backup printing Compliance: The SCADA system shall implement all required interlocking logic and safety control schemes in compliance with the regulations of the Electrical Inspectorate of Kerala The SCADA software shall support: Real-time monitoring, Event logging, Alarm management,Historical trend analysis,Report generation Secure, role-based user access control
LIGHT FIXTURES & FANS Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required .
Supply, installation, testing and commissioning of following lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including all labour and materials, as per approved drawings, data sheet for lighting fixture.
Supply,Installation,testing & commisioning of IP20 Recessed LED Downlighter made of pressure die cast aluminum housing, Fixture should have minimum efficacy at System level (Not Chip Level) >=110 lumens/watt with Minimum system Lumens 2000 with maximum system wattage of 18W. Life of fixture (Including dimmable Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, working temp range - 0°C < Ta < 45°C, and operating Voltage Range of 240 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.
Supply,Installation,testing & commisioning of IP20 Recessed LED Downlighter made of pressure die cast aluminum housing, Fixture should have minimum efficacy at System level (Not Chip Level) >=110 lumens/watt with Minimum system Lumens 1200 with maximum system wattage of 11W. Life of fixture (Including dimmable Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, working temp range - 0°C < Ta < 45°C, and operating Voltage Range of 240 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer.
Supply,Installation,testing & commisioning of LED based suspended continuous 4ft. Luminaire with a nominal system lumen output of 2200 lumens with Downward light ratio and a minimum system efficacy of 110 lm/W. The luminaire shall have a color temperature of 6500K and CRI≥80.The LED driver shall be accessible without opening the LED compartment. The luminaire shall have roll od diffuser option. The driver acess shall be from the backside of the luminiare The luminaire shall be made up of extruded aluminium and meet IP20 Rating with THD≤10% and PF≥0.9. The total Power Consumption should not exceed 21 W (Including dimmable Driver). Dimensions :- 1120mm x 53mm x 70mm. The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificates along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material, LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer along with technical bid. The bidder shall submit the Type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material.
Supply,Installation,testing & commisioning of LED based recessed continuous 4ft. Luminaire with a nominal system lumen output of 2200 lumens with Downward light ratio and a minimum system efficacy of 110 lm/W. The luminaire shall have a color temperature of 6500K and CRI≥80.The LED driver shall be accessible without opening the LED compartment. The luminaire shall have roll od diffuser option. The driver acess shall be from the backside of the luminiare The luminaire shall be made up of extruded aluminium and meet IP20 Rating with THD≤10% and PF≥0.9. The total Power Consumption should not exceed 21 W (Including dimmable Driver). Dimensions :- 1120mm x 53mm x 70mm. The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificates along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material, LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer along with technical bid. The bidder shall submit the Type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material.
Supply,Installation,testing & commisioning of LED based suspended continuous 2ft. Luminaire with a nominal system lumen output of 1200 lumens with Downward light ratio and a minimum system efficacy of 110 lm/W. The luminaire shall have a color temperature of 6500K and CRI≥80.The LED driver shall be accessible without opening the LED compartment. The luminaire shall have roll od diffuser option. The driver acess shall be from the backside of the luminiare The luminaire shall be made up of extruded aluminium and meet IP20 Rating with THD≤10% and PF≥0.9. The total Power Consumption should not exceed 11 W (Including dimmable Driver). Dimensions :- 1120mm x 53mm x 70mm. The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificates along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material, LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer along with technical bid. The bidder shall submit the Type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material.
Supply Installation, testing & comissioning of LED Surface mounted Downlighter having dia of 153mm(± 3mm) & height of 60mm(± 3mm) delivering minimum system lumen output of 2000 lumens (±5%) and system wattage of 18W (±5%) (Including dimmable Driver) & with a minimum system efficacy of 110 lm/W. The luminaire should have a color temperature of 6500°K, CRI≥80 and SDCM≤5. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Similar to above specs in Signify (Philips)/Wipro/LT.
Supply,Installation,testing & commisioning of LED Batten in 35W(Including dimmable Driver) 4000 lm, 4ft Extruded aluminum housing fitted with engg. Plastic end plates. Easy fit profiles acrylic diffuser provides smooth light distribution. LED populated on PCB comprising of cool White LEDs connected in series parallel. CCT-6500K, THD<10%, driver efficacy>85%, surge protection 3KV, CRI>80, SDCM<5, power factor>0.95, efficacy 110lm/w. Driver: constant current output driver, operating range 140 – 270V AC supply voltages. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Approved Make: Signify, cat. ref, no. BN170 LED40S
Supply,Installation,testing & commisioning of Integral LED 4ft IP65 batten having housing made of polycarbonate extrusion & diffuser made of polycarbonate (Diffuser-Non yellowing type). The luminaire should have a color consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K.The luminaire shall be compliant with IP65 classification. Luminaire shall be designed to emit at least 4340 nominal lumens at a system efficacy of minimum 124 lumen/watt. Power consumption should not be more than 35W. The lumianire shall have CRI≥80. The Life of fixture(Including dimmable Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor ≥0.95 @ full load and THD ≤10% @ full load and suitable for an operationg voltage range of 140-270V AC. Ripple ≤20 % and surge protection should be minimum 4KV (CM/DM), electrical insulation class should be Class I & driver should be of Class B serviceability. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, CISPR 15/ EN 55015 (9 KHz to 30MHz) for RFI, EMI/EMC, IEC 62384 for driver performance test. The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire driver shall have efficiency of ≥85%.The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificates along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material, LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer along with technical bid. The bidder shall submit the Type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material.
Supply,Installation,testing & commisioning of continuous suspended broad linear LED luminaire made of extruded aluminimum with anodized finish, polycarbonate/polystyrene front diffuser & Non-Integrated driver. The luminaire shall deliver minimum system lumen output of 2200Lumens(downwards only) with system wattage of maximum 20W,(Including dimmable Driver) shall have UGR<19. The luminaire shall have following dimensions L:1200mm, W:120mm & H:33mm (Tolerance in dimensions ±2%). The luminaire shall come with Separate Box for the Driver for mounting on or above the Ceiling. The life shall be L70B50@ 50K Hrs. The luminaire operating temperature shall be -10°C to +45°C. The luminaire driver shall have THD≤ 10%, PF ≥0.95, internal surge protection of 4KV, Ripple ≤5%, operating voltage range of 140V - 270V. The luminaire shall have Class - I protection & serviceability of Class B. The luminaire shall be IP20 & IK02 compliance. The luminare driver shall be of the same make/manufacturer as that of LED luminaires. The luminare shall have CCT of 6500°K, CRI≥80, & SDCM≤5. The luminaire brand name shall be embossed/engraved on the luminaire & not screen printed. The luminaire shall be EMI/EMC compliant & sucessfull bidder shall submit the report prior to supply of material. Luminaire manufacturer must have an in-house NABL accrediated lab to conduct LM79 & Type test as per IS10322 & the sucessfull bidder must submit the NABL accredation certificate for the same before the supply of material. The LED Luminaire & it's driver both should be BIS registered. The luminaire shall be supplied with adjustable suspension wires.
Supply,Installation,testing & commisioning of LED Highbay luminaire with a housing of High Pressure Die casted Aluminium and polycarbonate front cover. The luminaire should have a color consistency SDCM < 5, CRI > 70 and CCT of 5700K. The luminaire shall be compliant with IP65 classification and impact protection of IK08 to ensure durablility. Luminaire shall be designed to emit at least 20000 nominal lumens at a system efficacy of atleast 149 lumen/watt and maximum system wattage of 135W(Including dimmable Driver). The lumainaire shall have both Narrow beam and Wide beam options available to provide flexbility in applications.The luminaire shall be designed so as to ensure lumen depreciation of up to 70% over 50k burning hours @ design ambient temp 45 deg C. The luminaire shall be designed for operations under diverse environment from -10 deg C to 55 deg C.The electronic driver used shall have a power factor >0.95 and THD <10% with a minimum inbuilt surge protection of 4kV and suitable for an operationg voltage range of 220-240V AC. The fixture should be BIS certified. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be BY515P LED200S
Supply,Installation,testing & commisioning of recessed type LED 2x2 luminaire with CRCA housing suitable with fully diffused PS diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI 80 and CCT of 4000K/ 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding backlit solution efficacy of atleast 124 lumen/watt and maximum system wattage of 28W(Including dimmable Driver). The luminaire shall be designed so as to ensure L70B50 @ 50K Hrs.@ 45 Degree Ambient. The electronic driver used shall have a power factor >0.95 and THD <10% The fixture should comply with the parameters as per IS10322.
Supply,Installation,testing & commisioning of suspended/Surface mounted Cylinderical Downlight, 18w(Including dimmable Driver), 2000 lm, CCT 5700K, CRI>80, Efficacy ≥120lm/W, Surge 4Kv internal, THD ≤10% (At Full Load), Extruded aluminum housing,white/Black finish, Product Dia 100mm, Height 205mm, Life L70B50 @ 50K Hrs.@ 45 Degree Ambient temp. The product should be EMI/EMC compliant and ripple <5%. The product should have option of 24°, 36° and 60° beam angles to choose from as per the application. operating temperature should be -10° to +45°; operating volateg range 140-270. The LED driver should comply to IEC61347 -2 -13, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Product complying to above specs in Signify, LT or Endo
Supply,Installation,testing & commisioning of Decorative Pendant LED Luminaire delivering minimum system lumen of 4800 lm & the luminaire shall be with system efficacy ≥70 lm / W(Including dimmable Driver). Housing Extruded Aluminium Powder Coated, having dimensions of 900m dia and H75mm, IP20 , Opal milky white diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 140 to 270V , THD ≤ 10% & PF ≥ 0.95, 30K hrs@ L70B50 @ 45 degree ambient.. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type.
Supply,Installation,testing & commisioning of Decorative Pendant LED Luminaire delivering minimum system lumen of 6400 lm & the luminaire shall be with system efficacy ≥70 lm / W(Including dimmable Driver). Housing Extruded Aluminium Powder Coated, having dimensions of 1200m dia and H75mm, IP20 , Opal milky white diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 140 to 270V , THD ≤ 10% & PF ≥ 0.95, 30K hrs@ L70B50 @ 45 degree ambient.. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type.
Supply,Installation,testing & commisioning of Decorative Pendant LED Luminaire delivering minimum system lumen of 2100 lm & the luminaire shall be with system efficacy ≥70 lm / W(Including dimmable Driver). Housing Extruded Aluminium Powder Coated, having dimensions of 600m dia and H75mm, IP20 , Opal milky white diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be BIS Registered with electronic driver with input voltage range of 140 to 270V , THD ≤ 10% & PF ≥ 0.95, 30K hrs@ L70B50 @ 45 degree ambient.. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type.
Supply of Heavy duty bulkhead surface type lighting fixture 10W - 1100lm made up of pressure die-cast aluminium housing and Polyster Powder coated die cast aluminium with High quality polycarbonate diffuser in opal finish for glare free light distribution.High efficiency long life LED module with SMD LED package mounted on MCPCB with lumen efficacy of >100 lm/W. Powered by integral electronic LED driver with CCT 6500, CRI>80,THD<10%, PF>0.9, IP66, IK 09, Life class of 50,000 hrs @ L70, Operating Temperature: 0 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ. Driver Safety requirement standards:IS 15885, Test Report to be submitted, Photobiological Safety Norms: IS 16108, test Certificate to be submitted, Certification: LM79 for Luminaire, Lm80 for LED Source. Both the fixture and Driver should have separate BIS approval.Philips Endura Bulkhead WT202
Supply, installation, testing and commissioning of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . 300mm sweep.
Supply, installation, testing and commissioning of Wall fan 400mm sweep, 65W, Aluminium blades, 3 Speed, pull cord for speed and oscillation, Air delivery minimum 72 m3 / min, speed minimum 1350 revolution per minute, suitable for 230V, 50Hz, single phase AC supply earthing etc complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
LT PANELS (Must refer annexure BOQ Electrical for detailed specification) Supply, installation, testing and commissioning of indoor floor mounted panel complying IEC-61439 and other relevant IEC standards, IP42 (Indoor) and IP55 (Outdoor) rated, factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor Single core cable for voltage & current respectively, including providing and fixing following switch gears and as per schedules ,technical specifications etc.complete as required:
UPS Output Panel - Indoor Type Incoming: "MCCB: 415V, 50Hz, 125A, 4P, 25kA for 1 sec rated microprocessor based MCCB, with motor mechanism (capable of remote operation), LSIG protection,shunt trip coil, spreaders and breaker operating handle - 02 Set " "Indication lamps: LED type phase indication lamps suitable for 230V,50Hz AC with suitable control MCB (red, yellow, blue) - 2 set. LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) -2 set." "Metering: 3-phase TOD meter,class 0.5s with RS 485 communication port -02 set (The contractor should arrange for testing of CT & meters in electrical inspectorate laboratory/ TMR meter testing division of KSEBL. Technopark shall reimburse the necessary testing fees as submission of the receipts and test reports.)" "CTs: 3 Nos. 125/1A, 10VA, CL-0.5s current transformer for metering at MCCB incomer - 2 Set " Busbar: "Busbar (1 Set - 4P + E): Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable to carry 415V, 50 Hz, 125 A, 25 kA for 1 sec of required length and cross sectional area. Note: Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approval and busbar size has to be as per the approved GA drawing." "Indication lamps: LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip,) - 2set." Outgoings : "MCB; 32A, 4P, 10kA - 25 Sets " "MCB; 32A, DP, 10kA - 12 Sets " 4P CONTACTOR: 32A- 25 Set, 2P CONTACTOR: 32A- 12 Set SCADA Operations: "The following operations of the Panel shall be performed through SCADA: 1. I/C- 01- ON, OFF & RESET 2. I/C- 02- ON, OFF & RESET 2. All OUTGOINGS (37 Nos)- ON, OFF & RESET The following status parameters of the Panel shall be monitored through SCADA: 1. I/C-01- ON, OFF, TRIP, LOC/REMOTE 2. I/C-02- ON, OFF, TRIP, LOC/REMOTE 2. All OUTGOINGS (37 Nos)- ON, OFF" "The following parameters from all TOD meters & kWH meters shall be monitored through SCADA: 1. Power- (kW, kVA, kVAR) 2. Energy- (kWh, kVAh, kVARh) 3. Maximum Demand (MD) Note: All equipment (FRTU, N/W switches etc), Optic Fibre Cables, control wiring and other accessories required inlcuidng necessary modifications shall be under the scope of work and without additional cost"
BATTERY CHARGER Supplying, installation, testing and commissioning of totally enclosed, indoor type, IP-42 rated, fully wired, 2X60 Amp, battery charger cum DCDB (for DCDB refer single line diagram for substation auxillary) suitable for 110V bipolar DC, complete with 2X200 AH VRLA batteries (external), battery rack, interconnecting cables, battery charger, DC bus, DC MCBs, controller and complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge.
EXTERNAL LIGHTING Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 4.5 metre and upto 6.5 metre
Above 8.0 metre and upto 10.0 metre
Supply, installation, testing and commissioning of following outdoor lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including all labour and materials, as per approved drawings, data sheet for lighting fixture.
Supply, installation, testing and commissioning of LED based post top, housing made up of Die Cast aluminum Housing anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 6000 lumens and maximum system wattage of 60 Watts (±5%).The fixture shall have a weight of 10.7 to11.5 Kg and CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP65 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08, SDCM<=5.The fixture shall dimensions of 488mm (dia) x 620mm (ht). The fixture driver should have an operating voltage range of 110-277 V, surge protection of >=20KV SPD, PF >0.9 , THD<10% and SDCM<5. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Ref Model: BDP461 LED65 WW 110-277V TS or approved Equivalent.
Supply, installation, testing and commissioning of 3 MTR height conical decorative pole with marine grade coating, suitable for above post top complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of LED based spike light with Aluminium housing and Grey powder coating . The luminaire should have minimum light output of 520 lumen and shouldn't exceed max power consumption of 8W. Product shoul have THD ≤33% & It should have minimum IP 65 protection. The Operating Voltage Range should be in range of 160-270 V, Power factor should not be less than 0.8 & surge protection of Min 1KV. The electronic driver shall be in-built.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, , BIS certificate for LED Luminairecomplete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge .
Supply, installation, testing and commissioning of ground mounted 18W 3000K luminaire made up of die-casting with aluminum housing stainless steel trim frame with high quality tempered glass cover (8-14mm), Dimension Ø180mm H175mm with recess mounting box. The luminous flux of the luminaire is in the range of 1800lm±10%, Beam angle 20°. The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with LED of CRI70. The integral potted driver comes with the power factor greater than or equal to 0.9 and a surge protection up to 2KV . The driver input voltage 110~240Vac at 50-60Hz and operating temperature of -40 ~ +50°C with CE/CB/EMC approbation. Life of the fixture should be 50K hours L70B50 @ ta 35°C. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Ref Model:BBP343 or approved Equivalent.
Supply, installation, testing and commissioning of LED Ground Mounted Bollard (0.8 m height) with a system lumen output of 400 lumens and a minimum system efficacy of 50 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. Input Voltage 220-240V/ 50-60Hz. The luminaire housing should made of Extrusion aluminium with polycarbonate diffuser. The total power consumption should not exceed 8W (including driver) complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Ref Model: BCP151 LED150/NW PSU 220-240V 7043 or approved Equivalent.
Supply, installation, testing and commissioning of underwater recessed light fixture wiht outer casing, Input power : 15-18W, lumen output should not be less than 1260-1350lm and medium beam 25 degree light distribution. Luminaire made of Supreme corrosion proof Under Water grade Stainless Steel. Injected GFR Engineering Polymer body component. Wall recessed housing made of GFR polymer. Impact resistant safety tempered glass cover. Marine grade 316 stainless steel screw. Cable entry protected by M12 cable gland. To be used with H05RN-F/ H07RN-F cable with 4-7mm. diameter. Pre-wired with 2x1.0 sqmm. H05RN-F neoprene cable. IMQ approved. Protection class IP68. Mechanical resistance IK05 on body and IK07 optical part. SS finish.Ccolour temperature 3000K , Colour rendering index (CRI)>80. SDCM-3 MacAdam. Service life of LEds should be at least 66,000 operating hours L70B10. Remote LED driver 24Vdc and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension should not be less than Dia 235mm, Depth 93mm. To be supplied with necessary accessories like drivers, IP connectors etc complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge
Supply, Installation, Testing & Commissioning of IP66, sealed with anti-UV polyurethane having lumen output from 650 lm per meter and CCT 3000K SDCM≤ 3 and wattage as 10.5W/m, better color consistency for visual comfort. The led strip shall operate on voltage 24VDC. It shall have long lifespan of 30K hrs. L70B50@35℃. Led strip silicon material seals without color shifting and anti-UV aging. It shall have CRI90 for better vivid color rendering and shall operate on DC low voltage driven for safetyshall be suitable for side view and top view for bend option to fit for installation, complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge Ref Model :BGC401 650LM 3000K L5000 or approved Equivalent.
Supply, installation, testing and commissioning of LED surface mounted circular metal downlighter made of PDC aluminium having IP rating as IP40 (from front). Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI ≥ 80 and CCT of 3000K. The fixture should have a minimum system efficacy of 110 lumen/Watt (±10%) and a minimum system lumen output of 1500 lumens and system wattage of 13.5 Watts. The luminaire shall be designed so as to ensure 30K burning hrs. @ L70 @ ambient temp 45 deg C. The electronic driver used shall have a power factor ≥0.90 @ full load , THD ≤10% @ full load . The driver shall have in-built surge protection of 2.5KV. The luminare driver shall be of the same make/manufacturer/brand as that of LED luminaires. The luminaire driver shall have efficiency of ≥85%. The luminaire shall have BIS registration & the bidder shall submit the BIS certificates along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material, LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer along with technical bid. The bidder shall submit the Type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material. Product complying to above specs complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge . Ref Model: SM296C LED15S-3000 PSU WH or approved Equivalent.
Supply, installation, testing and commissioning of wall surface up / down light, Input power : 10W LED, lumen output should not be less than 950lm . Luminaire made of aluminum body and components. It shall be resistant to corrosive environment. Luminiare primarily coated with epoxy resin and top coated with UV stabilized polyester. Impact resistant safety tempered glass cover. High performance metallized reflector. Protection class IP65 complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge
Supply, installation, testing and commissioning of following decorative poles complete as required confirming to tender specifications, relevant standards and codes and as per directions of Engineer in charge
4.0 Metre Pole
6.0 Metre Pole
9.0 Metre Pole
LAISONING WORKS Laisoning with all Govt offices, depositing necessary fee for sanction of Load, preparation of all services lines as per KSEI requirement with all service charges and infrastucture complete as required.
ENERGY STORAGE SYSTEM Supplying, installation, testing and commissioning of 250kW / 0.5 MWhr Battery Energy Storage System (BESS) comprising advanced Lithium Iron Phosphate (LiFePO₄) or approved equivalent battery modules arranged in modular rack configuration, housed within weatherproof, containerized enclosures (IP54 or better) complete with: 1.Integrated Battery Management System (BMS) 2.Bidirectional Power Conversion System (PCS) rated for 500 kW continuous output at 415 V, 3-phase, 50 Hz 3.Energy Management System (EMS) with configurable charging/discharging schedules, SCADA integration via Modbus TCP/IP 4.Fire detection and suppression system using clean agent (e.g. NOVEC 1230) 5.Air conditioning/forced ventilation system for thermal management 6.Complete AC and DC cabling, terminations, earthing, cable trays, interconnects, and structural supports as required 7.Battery bank usable capacity ≥ 90% DoD, with minimum 7000 cycles life, and round trip efficiency ≥ 85% 8.Provision of interface with building internal grid via transformer if required 9.Full compliance with IEC 62619, IEC 62933, IS 7098, IS 3043, IEEE 1547, and Electrical Inspectorate rules All works shall be carried out as per approved drawings, tender technical specifications, and to the satisfaction of the Engineer-in-Charge.
IT Data & Voice Networking Systtem SITC of 1 Meter High Speed Gigabit 24AWG UTP Patch Cord, LSZH, UL Listed, RoHS Certified etc all complete
SITC of 2 Meter High Speed Gigabit 24AWG UTP Patch Cord, LSZH, UL Listed, RoHS Certified etc all complete
SITC 19” Cat 6 UTP RJ-45 Patch Panel with 24 ports on 1U, Strain relief and cable management with inbuilt wire manager, Universal wiring – T568 A or B wiring pattern, Snap in type, provided with mini cable ties, cage nuts & rare cable management etc. all complete
SITC of Dual Port Faceplates including labels and mounting screws, Provision for accepting any Keystone Style RJ45 Jacks, Provision for Both RJ45 type, Built-in Dust Covers etc all complete
SITC of Single Port Faceplates including labels and mounting screws, Provision for accepting any Keystone Style RJ45 Jacks, Provision for Both RJ45 type, Built-in Dust Covers etc all complete
SITC of Cat 6 UTP RJ45 Keystone Jacks / Outlets, Press-Fit technology, Compatible with EN 50173 / ISO IEC 11801, Qualified Screened Class 6 Component, Permanent Link & Channel ANSI/TIA-568-2.D etc all complete
SITC of Category 6 UTP Cable - LSZH, High-Speed Gigabit Ethernet UTP 250 MHz Class E Cables for Cat 6 Consists of 23AWG Solid Bare Electrolytic Grade Copper Conductors, HDPE Insulated Twisted 4 Pair, RipCord, and LSZH Outer Jacket, Gigabit Ethernet (1000 Base-T), UL Listed, RoHS Certified in existing concealed/surface conduits/Raceways as per specification etc. all complete
SITC of 42U Close Floor Mounted Rack - (800mm x 1000mm - W X D), with Perforated doors (Front & rear), 2 Nos. of 1U power distribution box, with 10 x IEC - C13 sockets & with 32Amp MCB- terminating on a IP56 power sockets - VERTICAL - in each rack, 2 No. Horizontal PDU with 5/15Amp Universal Sockets with 32Amp MCB - in each rack, Front mounting PVC Cable managers/ guide x 10 in each rack (1U Horizontal), Integral Cable management ducts/ arms (on either side) with covers, Fan housing unit 4 Fan POSN - 90 CFM 230VAC, Bar, Earthing 42U with Mounting Hardware (Pack of 10) as per given Specification etc. all complete
SITC of 24U (W 600mm/ D 600mm) Floor mount with front glass door and side panels with lock & key (load bearing capacity of 40Kgs), AC main Channel 06 points 5 Amp (PDU) with Mounting Hardware (Pack of 10) as per given Specification etc. all complete
SITC of 12U (W 600mm/ D 600mm) wall mount with front glass door and side panels with lock & key (load bearing capacity of 60Kgs), AC main Channel 06 points 5 Amp (PDU) with Mounting Hardware (Pack of 10) as per given Specification etc. all complete
SITC of 1 U PVC Cable Manager as per given Specification etc. all complete
SITC of Layer-3 Stackable 10G Managed Core Switch having minimum 20 SFP+ ports and 4 Combo (SFP+/10GBASE-T) ports, switching capacity ≥ 480 Gbps, forwarding rate ≥ 350 Mpps. Shall support static and dynamic routing (OSPF), VRRP, IGMP/MLD/PIM multicast protocols, VLAN, QoS, ACL, VRRP, IPv6 tunneling, BFD, and sFlow. The switch shall include redundant hot-swappable power supplies, hot-swappable fans, and enhanced software image with support for Layer 3 advanced features. Should support CLI, SNMP v1/v2/v3, Web GUI, USB config, and dual-image. Shall comply with IEEE 802.1Q, 802.1p, 802.3ad, 802.3x, 802.1s/w/d, and be certified for CE, FCC, RoHS with the following accessories: a. 10GBASE-SR SFP+ Transceiver Module compatible with the core switch and access switches, for use over OM3/OM4 multimode fiber, LC duplex connector, wavelength 850nm, range up to 300 meters. Module shall be hot-swappable and fully compliant with IEEE 802.3ae, RoHS, and MSA standards with quantities sufficient for connecting the Layer-02 switches. b. 10G SFP+ to SFP+ Passive Direct Attach Copper Cable, 1 meter length, suitable for switch-to-switch connectivity within rack. Shall be compatible with all approved switches, hot-pluggable, low power, RoHS compliant, and support data rates up to 10.3 Gbps with quantities sufficient for connecting the Layer-02 switches
SITC of 6 Core Outdoor LSZH Multi Mode Optical Fibre Cable, 50/125µm, Conformance to ANSI/TIA-568.3-D, Telcordia GR-20, IEC 60794-2, ISO/IEC 11801, ISO/IEC 24702, Water proof layer & excellent moisture resistance provided etc all complete
SITC of 6 Port Fiber LIU Loaded with LC MM Coupler, Splice tray with layered structure, Conformance to Multi Mode (ANSI/TIA-568.3-D, IEC 61300-3-4, IEC 61300-3-6, IEC 60874-1, ISO/IEC 11801 complete in all respect etc all complete
SITC of 24 Port Fiber LIU Loaded with LC MM Coupler, Splice tray with layered structure, Conformance to Multi Mode (ANSI/TIA-568.3-D, IEC 61300-3-4, IEC 61300-3-6, IEC 60874-1, ISO/IEC 11801) complete in all respect etc. all complete
SITC of SC MM Pigtail (1.0 Meter), LSZH jacket, meets IEC-60332 (LSZH) flame rating for standard safety compliant as per given Specification etc. all complete
SITC of SC-LC MM Fiber Patch Cords ( 3 Mtr), LSZH jacket, meets IEC-60332-1 (LSZH) flame rating for standard safety compliant as per given Specification etc. all complete
SITC of 24-Port Managed Network Switch (Layer 2), Rack Mountable, PoE, with SFP Uplink Ports Supply, installation, testing and commissioning of 24-Port Layer 2 Managed Network Switch with the following minimum specifications: Ports: 24 x 10/100/1000 Mbps RJ-45 Ethernet ports,Uplink Ports: Minimum 2 x 1G SFP uplink ports, Switching Capacity: Minimum 56 Gbps,Forwarding Rate: Minimum 41.6 Mpps, Management: Fully managed with Web GUI, CLI, SNMP v1/v2/v3, VLAN Support: 802.1Q VLAN tagging, support for at least 256 VLANs Security Features: Port Security, DHCP Snooping, Storm Control QoS: Layer 2/3 QoS, prioritization based on 802.1p/DSCP Spanning Tree: STP, RSTP, MSTP Other Features: IGMP Snooping, Link Aggregation (LACP), Loop Detection, Broadcast Storm Control Mounting: 19” Rack Mountable with mounting accessories Power Supply: Internal Warranty: Minimum 5 years OEM warranty
SITC of 30 Pair TAG Blocks (with Module, back mount frame & Enclosure (Krone) (wall mountable), with label holders etc. all complete
SITC of 25 Pair Riser cable (Category 5 Riser cable consisting of multiple core or solid copper conductors of 24 AWG size insulated with expanded polyethylene covered by a PVC skin and inner shielding for grounding. The core shall be covered by a layer of plastic tape and overlaid with a corrugated PVC plastic. etc. all complete
SITC of IP PBX Communication Manager - Duplex (Redundant mode), Should be able to populate 2 PRI (Upgradable to 4), 08 CO Lines in distributed gateways (for redundancy), 04 port analog trunk card (2 no's), 01 port ISDN PRI card (2 no's), 16 Port Analog Extension cards (18 no's), Voice Mail: 08 Ports (with 24-30 Hrs recording), Licenses: 250 Analog Extensions, 16 IP Extensions, 2 Operator consoles, 10 nos of IP telephones , 30nos of Analogue Telephones, Attendant Console: One soft (BCT) & One hard with all required accessories etc all complete including necessary cable connections, connectors & other required accessories.
SITC of Call Billling & Voice Mail Software (FCS Winsuite for integration with the Exchange for full suite features – viz. Voice Mail, Call Accounting, Wake up call etc.) with all required accessories etc all complete along with SITC of Desktop PC's (Latest Intel Corei5 Processor based PC's, with 4GB Memory/ 500GB HDD/ DVD/ Kbrd & Mouse/ 19" TFT LED Monitor) & licensed OS with all required accessories etc all complete
SITC of 300 Pair TAG Blocks (with Module, back mount frame & Enclosure (Krone) (wall mountable), with label holders etc. all complete
LIFT & ESCALATOR WORKS Design, fabrication, supply, installation, testing, and commissioning of a 24-passenger, machine-room-less elevator with a minimum speed of 2.5 m/s, serving 12 stops. The elevator shall be equipped with a VVVF gearless regenerative drive, microprocessor-based control system, and advanced Destination Control System (DCS) for intelligent traffic handling and enhanced passenger efficiency. The system shall include all associated fixtures, controls, communication interfaces, and accessories as required, and shall comply with the attached technical specifications, applicable statutory regulations, and relevant codes and standards. The elevator control system shall be IoT-enabled, offering secure cloud connectivity, remote diagnostics, and condition-based monitoring features. It shall support integration with third-party smart building systems via RESTful APIs, BACnet/IP, or equivalent open protocols. The lifts should be capable of communicating with automatic robotic cleaning machines deployed by Technopark to automatically call the lift and access the required floor. The cost shall include cloud service licensing, hosting, and data storage for a minimum period of two years from commissioning. The system shall also be provisioned for future integration with Technopark’s Digital Twin platform and other enterprise asset management solutions, enabling lifecycle data exchange, operational analytics, and system-level visibility. All installation and commissioning activities shall be undertaken under the supervision of certified personnel and in accordance with the directions of the Engineer-in-Charge.
Design, fabrication, supply, installation, testing, and commissioning of a 15-passenger, machine-room-less elevator with a minimum speed of 2.5 m/s, serving 12 stops. The elevator shall be equipped with a VVVF gearless regenerative drive, microprocessor-based control system, and advanced Destination Control System (DCS) for intelligent traffic handling and enhanced passenger efficiency. The system shall include all associated fixtures, controls, communication interfaces, and accessories as required, and shall comply with the attached technical specifications, applicable statutory regulations, and relevant codes and standards. The elevator control system shall be IoT-enabled, offering secure cloud connectivity, remote diagnostics, and condition-based monitoring features. It shall support integration with third-party smart building systems via RESTful APIs, BACnet/IP, or equivalent open protocols. The lifts should be capable of communicating with automatic robotic cleaning machines deployed by Technopark to automatically call the lift and access the required floor. The cost shall include cloud service licensing, hosting, and data storage for a minimum period of two years from commissioning. The system shall also be provisioned for future integration with Technopark’s Digital Twin platform and other enterprise asset management solutions, enabling lifecycle data exchange, operational analytics, and system-level visibility. All installation and commissioning activities shall be undertaken under the supervision of certified personnel and in accordance with the directions of the Engineer-in-Charge.
Design, fabrication, supply, installation, testing, and commissioning of a 15-passenger, machine-room-less elevator with a minimum speed of 2.5 m/s, serving 11 stops. The elevator shall be equipped with a VVVF gearless regenerative drive, microprocessor-based control system, and advanced Destination Control System (DCS) for intelligent traffic handling and enhanced passenger efficiency. The system shall include all associated fixtures, controls, communication interfaces, and accessories as required, and shall comply with the attached technical specifications, applicable statutory regulations, and relevant codes and standards. The elevator control system shall be IoT-enabled, offering secure cloud connectivity, remote diagnostics, and condition-based monitoring features. It shall support integration with third-party smart building systems via RESTful APIs, BACnet/IP, or equivalent open protocols. The lifts should be capable of communicating with automatic robotic cleaning machines deployed by Technopark to automatically call the lift and access the required floor. The cost shall include cloud service licensing, hosting, and data storage for a minimum period of two years from commissioning. The system shall also be provisioned for future integration with Technopark’s Digital Twin platform and other enterprise asset management solutions, enabling lifecycle data exchange, operational analytics, and system-level visibility. All installation and commissioning activities shall be undertaken under the supervision of certified personnel and in accordance with the directions of the Engineer-in-Charge.
CHILLER PLANT OPTIMIZER
Supply, installation, testing & commissioning of programmable controller having processors of 32 Bit 50 MHZ, BACNET compatible, controller for Pumps, Cooling Tower . The controller shall support easy Graphical Programming and shall be able to store the programmed in the controller rather than store in the PC. It should include Lockable Mounting Cabinets duly powder coated, connector strip, internal wiring etc.
FIELD DEVICES
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF IMMERSION TEMP. SENSOR & THERMOWEL
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF CURRENT RELAY
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF DIFF. WATER PRESSURE SWITCH
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF AMBIENT COMBINED TEMP & RH SENSOR
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF WATER LEVEL SWITCH.
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF BTU METER (200 MM DIA)
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF DIFF. WATER PRESSURE SENSOR
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF TEMPERATURE SENSOR
3RD PARTY INTEGRATIONS Supply & Installation of Integrator for Chiller, FLOW Meter, Energy meter and VFD's Note: Overall plant room efficiency shall be ≤ 0.7 KW/TR
Water flow rate of each Pump - 3634 LPM Pump Head (Suggested) - Approx 35-40 Mtrs. Suggested Pump Motor - 50 HP
COMBINED AIR & DIRT SEPERATORS Supply, Installation, testing and commissioning of a combined Air and Dirt Separators in accordance with Section VIII, Division I of the ASME/IS Standard Boiler and Pressure Vessel Code designed, constructed, inspected and stamped per ASME Section VIII, Division 1. As per Specifications on the return water line located at the pump suction or a suitable location in AC Plant Room as suggested. Separator should be capable of removing all micro bubbles and should have a steel tube & copper wire media to carry out its operation. It should be able to remove upto 10 microns of dirt particles. The separator should be complete with high capacity automatic air vent, blow down valve, skim valve, non return valve, butterfly valve connection for makeup water inlet, flanges, drain valve etc.
ONLINE SCALE PREVENTER (Online non chemical water treatment) Supply, installation, testing and commissioning of Online non chemical water treatment Scale Preventer system for preventing scale formation in condensor tubes by converting hardness salts into colloidal particles through a process of Adsorbption and turbulance without using any chemicals and any other source of energy. Suitable for water flow rate of 5677 LPM as per specification.
CLOSED EXPANSION TANK Supply, Installation, Testing & Commissioning of The Closed expansion tank will be of MS construction of 6 mm thick with interchangeable EPDM. Butyl rubber membrane.The Expansion tank shall be complete with safety relief valve,Pressure reducing valve and pressure gauge.The tank will be of pressure rating to suit the system pressure and will be sized adequately to compensate for water expansion due to operating temparature variations.The tank shall be fabricated as per IS 2825-1969 for non-fired pressure vessels and the flanges shall be as per IS 6392-1971.For Chilled water application,it will be insulated with 50mm thick insulation to the specifications and cladded with 26G aluminium cladding.The expansion tank shall be suppled along with pressurisation unit.The pressurisation unit shall consists of two nos(1 Working+1 Stand by) high pressure pumps of suitable pressure rating mounted on MS frame,complete with inter connect piping,isolation valves,NRN,Y Strainer,Pressure Gauge,Pressure Transmitter,auto logic panel(IP 54) with dry run protection,electrical MCB and inter connecting wiring. 2200 ltrs
Supply, Installation, testing and commissioning of Electro-Chemical Treatment System for Cooling Tower (Non-Chemical) for Cooling Tower Tratment. The system should be equipped with Automatic Self Cleaning Mechanism & Automatic Blowdown Control. The proposed system should be manufactured and complied with ISO 14001:2015, ISO 9001:2015. The system must be CE + RoHS compliant. The proposed system should minimize blow down water consumption up to 50%. No/Zero Chemicals uses for cooling tower circuit, technology must fall under green technology initiatives, the system must avoids algae and micro-bacterial formation in water or surface of Pipe/ CT/ fills. The system must have components like - Electrolytic Reactor, Automated Scrapper mechanism for reactor cleaning, Automatic Blowdown control, Automatic Back wash Feature, Control Panel, Skid with Pumps & Valves. Testing: The Manufacturer shall have Hydrostatic Test Bed Facility to Witness Factory Acceptance Test for Hydrostatic Testing of machine at 10 Bar Pressure. Note : Electro-Chemical Treatment System aligns more closely with ESG principles over Solid Chemistry due to its chemical-free operation, redused enviromental impact, and improved worker safety.
THERMAL ENERGY STORAGE TANK
Waterproofing of all internal RCC surfaces shall be done using Polyurea-based spray-on membrane, manufactured in ISO 9002 certified plants. The waterproofing system shall be factory-tested and guaranteed leak-proof for a minimum of 5 years. Watertight pipe penetrations shall be provided using steel sleeves with puddle flanges.
Internal thermal insulation shall be done using PUF spray foam, minimum 50 mm thick, with density ≥ 40 kg/m³, thermal conductivity ≤ 0.025 W/m·K, and compressive strength ≥ 12.0 kgf/cm². The short-term anti-water pressure strength shall be ≥ 3.0 kgf/cm² and long-term strength ≥ 2.2 kgf/cm². Roof insulation shall be increased as per the hydraulic design requirements.
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200mm dia
250mm dia
300mm dia
350mm dia
450mm dia
Providing and fixing in position the industrial type pressure gauge complete with valves etc. as required
Providing & fixing in position the mercury in glass industrial type thermometer complete as required
INSULATED VALVES Supplying, fixing, testing, and commissioning of the following valves, strainers, and gauges in the chilled water piping, duly insulated as per the Technical specification mentioned in the tender document (published vide technical corrigendum) and adequately supported as per specifications. (AS AN ALTERNATE, PRE-INSULATED BUTTERFLY VALVES, BALANCING VALVES, Y STRAINERS & NON-RETURN VALVES, AS PER SPECIFICATIONS, CAN BE USED). BUTTERFLY VALVE/ BALL VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation as specified. .
450mm dia (Butterfly Valve)
200mm dia (Butterfly Valve)
100mm dia (Butterfly Valve)
80mm dia (Butterfly Valve)
65mm dia (Butterfly Valve)
50mm dia (Butterfly Valve)
40mm dia (Butterfly Valve)
32mm dia (Butterfly Valve)
25mm dia (Butterfly Valve)
MOTORISED BUTTERFLY VALVE with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation as specified 200mm dia (M.Butterfly Valve)
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF BTU METER (450 MM DIA)
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water circulation as specified. 200mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation including insulation as specified.
200mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Non-Return valve with dual plate of CI body SS plates vulcanized NB seal flanged end & PN16 pressure rating of Chilled Water circulation including insulation as specified. 200 mm dia
SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF BTU METER (for TES) 250 mm dia
Flexible coupling with anti vaccum rings complete with control units, flanges, nuts, bolts, seal etc. 200 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Air Vent (GM globe valve) 25 mm dia.
Auto Air Vent- 25 mm dia.
Water Flow Switch for following : 200 mm dia.
Supply and fix Valve, stop, screwed,25 mm (1”) dia pipe
Supply, Installation, Testing, and Commissioning of PN10-rated PPR (Polypropylene Random Copolymer) drain piping, conforming to IS 15801:2008, for discharging condensate, equipment drains, and blowdown lines within the HVAC system. The scope includes all necessary elbows, tees, couplers, reducers, end caps, and supports required to complete the system as per layout and site conditions. All pipes shall be joined using heat fusion welding or mechanical fittings, ensuring leak-proof joints. The piping shall be supported using powder-coated or epoxy-painted MS clamps or saddles at standard intervals, with neoprene/rubber lining to avoid abrasion and vibration. No insulation is required. The entire system shall be installed with proper slope, alignment, and venting to ensure smooth gravity drainage and avoid air locks. The system shall be tested for leakage and performance prior to handover, in accordance with IS code practices and project specifications.
50 mm dia
40 mm dia
32 mm dia
25 mm dia
500 mm dia
250 mm dia
Supply and fix Valve, ball valve, 40 mm dia
Supply and fix Valve, butterfly conforming to IS 13095,50 mm dia
Supply and fix Valve, butterfly conforming to IS 13095,250 mm dia
Supply and fix Valve, butterfly conforming to IS 13095,500 mm dia
Supply and fix Valve, motorised butterfly conforming to IS 13095,250 mm dia
Auto Air Vent - 25mm dia
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. BALANCING VALVE 250m dia
Non-Return Valve with dual plate of CI Body SS plater, vulcanized NB seal flanged end & PN 16 pressure rating of chilled water circulation including insulation as specified.
NRV 250 mm dia
Y - STRAINER - 250 mm Dia
Pot Strainer 500 mm dia
Water Flow Switch for following pipes :-250 mm dia
Supply and fix Valve, stop, screwed,25 mm dia pipe
Flexible coupling with anti vaccum rings complete with control units, flanges, nuts, bolts, seal etc. 250 mm dia
TFA with ERW Fresh Air Quantity : 1200 CFM Supply Air Quantity : 12000 CFM (45 TR) Exhaust Air Quantity : 2000 CFM Supply & Exhaust air 50 mm of WG
TFA with ERW Fresh Air Quantity : 1000 CFM Supply Air Quantity : 10000 CFM (15 TR) Exhaust Air Quantity : 1500 CFM Supply & Exhaust air 50 mm of WG
TFA with ERW Fresh Air Quantity : 900 CFM Supply Air Quantity : 9000 CFM (34 TR) Exhaust Air Quantity : 1400 CFM Supply & Exhaust air 50 mm of WG
TFA with ERW Fresh Air Quantity : 860 CFM Supply Air Quantity : 8600 CFM (34 TR) Exhaust Air Quantity : 1300 CFM Supply & Exhaust air 50 mm of WG
Smart Air Handling Unit (AHU) with integrated EC (Electronically Commutated) Fans Supply, installation, testing and commissioning of factory fabricated Ceiling suspended/Floor mounted Double Skinned Chilled Water Air-handling units (to be supplied by AHU manufacturer), fabricated out of extruded aluminium section with 0.8mm precoated Galvanised steel sheet outside and 0.8 mm plain Galvanised steel sheet inside with 40mm thick, minimum 32 Kg/Cu.M density PU foam insulation complete with backward / aerofoil curved blower/ blower section and EC blower motor TEFC type suitable for operation on 415 volts + 10%, 50 Hz + 5% AC supply, 6 Row coil for floor mounted unit & 4 row coil for ceiling suspended unit, made of Aluminium finned Copper tube with coil section, , Micro electrostatic jet ion needle filter equivalent to MERV 13 fine filter with an efficiency of 99% down to 3 microns & 95% gaseous contamination removal(CSIR, NPL& GREEN Certified), pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% polished stainless steel drain pan made out of 18G SS sheet duly insulated complete with motor and drive package etc. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to the specifications with static pressureas mentioned. The unit shall be BMS compatible and shall be equipped with UVGI system (UL listed to 2043 & 1995) as per specifications. The smart AHU should also include RS-485 port compatible with BMS, on-board protocol with touch screen to display EC fan operation status, chilled water valve operation status, AHU air flow (CFM) and AHU power consumption, chilled water in-out temperature, common alarm, trip fire alarm to shutdown AHU in case of signal from fire panel. The cost should include electrical starter panel with auto/manual switch and incomer power terminal. The noise level of AHU shall be 68 dB at 1.5 mtrs in free field conditions. CEILING SUSPENDED UNIT Approved Makes: EC Fans: EBM, Nicotra, Kruger, Ziehl Abegg AHU Units: Systemair, Stulz, Fläktwood, Johnson Controls (JCI), Trane, Carrier
4200 CFM / 7.5 TR 30 mmwg
4200 CFM / 6.5 TR 30 mmwg
4000 CFM / 5.5 TR 30 mmwg
3200 CFM / 5.5 TR 30 mmwg
3000 CFM / 4.5 TR 30 mmwg
2800 CFM / 4.5 TR 30 mmwg
2600 CFM / 4.0 TR 30 mmwg
2200 CFM / 3.5 TR 30 mmwg
1800 CFM / 3.0 TR 30 mmwg
1500 CFM / 2.5 TR 30 mmwg
1400 CFM / 3.0 TR 30 mmwg
TREATED FRESH AIR UNITS Supply, installation, testing and commissioning of factory fabricated Floor mounted Double Skinned Chilled Water Treated Fresh Air Units (to be supplied , fabricated out of extruded aluminium section with 0.8mm precoated Galvanised steel sheet outside and 0.8 mm plain Galvanised steel sheet inside with 40mm thick, minimum 32 Kg/Cu.M density PU foam insulation complete with backward / aerofoil curved blower/ blower section and EC blower motor TEFC type suitable for operation on 415 volts + 10%, 50 Hz + 5% AC supply, 8 Row coil for floor mounted unit & 8 row coil for ceiling suspended unit, made of Aluminium finned Copper tube with coil section, , Micro electrostatic jet ion needle filter equivalent to MERV 13 fine filter with an efficiency of 99% down to 3 microns & 95% gaseous contamination removal(CSIR, NPL& GREEN Certified), pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% polished stainless steel drain pan made out of 18G SS sheet duly insulated complete with motor and drive package etc. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to the specifications with static pressureas mentioned. The unit shall be BMS compatible and shall be equipped with UVGI system (UL listed to 2043 & 1995) as per specifications
14500 CFM / 96 TR 65 mmwg
9600 CFM / 64 TR 65 mmwg
8700 CFM / 58 TR 65 mmwg
8500 CFM / 56 TR 65 mmwg
4500 CFM / 30 TR 65 mmwg
3350 CFM / 22 TR 65 mmwg
2750 CFM / 18 TR 65 mmwg
FAN COIL UNIT Supply, Installation, Testing and Commissioning of Ceiling Concealed type Chilled Water Fan Coil Units, with EUROVENT/ AHRI CERTIFIED performance, with energy efficient BLDC / EC motor. The unit shall comprise of a 3/4 row chilled water coil. The BLDC/ EC motor shall be driven by its own in-built Inverter Drive/ Controller, suitable to connect and communicate with third party automation system or thermostat. The unit shall come with a pre-assembled valve station kit comprising of a Pressure Independent balancing cum control valve PN25 rating, ball valve with strainer & ball valve w/o strainer. the shadow of entire valve station to fall within the auxiliary drain tray provided. The unit shall be suitable for control using a Digital Controller/ Thermostat system with Digital Display and/ or automation systems, electrical terminal with protective covering for power incoming shall be provided. Fire retardant canvass connections with GI powdercoated finish angle flanges on both sides. The unit shall be designed for low noise low vibration operation, below NC45 at 3m distance under test conditions.
AHU Controls Set of controls comprising of thermostat and electronic proportioning thermostat with digital display having sensors with probe, cabling, interlocking etc. alongwith on off features.
SPLIT TYPE AIR-CONDITIONERS Supplying, Installing, testing and commissioning of air-cooled High Wall type split AC unit for Facility Block & Cassette unit for residence for heating & cooling , inverter type along with indoor/ outdoor units, controls, copper piping, uPVC condensate drain piping, valves and closed cell nitrile rubber insulation suitable to operate on 230 Volts 50 Hz AC supply etc. Quoted price shall include cost of wireless remote controller, wiring, control cable ,MS stand for placing outdoor unit with rubber pad isolator & earthing. Unit shall be provided with auto timer setting, complete as per technical specifications and tender drawings.The length of refrigerant pipe and drain pipe shall be considered as per drawings.The quoted price shall include cost of refrigerant.
UPTO - 6500 CFM
Supply Installation Testing & Commissioning Air quality monitoring system shall have ability to detect PM 2.5, Co2, HCHO, TVOC, temperature & humidity. It can transmit data by Wi-Fi, GPRS, GSM Sim card, RS485, and support online firmware upgrades and checking data on android and IOS. It can rapidly access to real time data value and easy to operate.
AIR DISTRIBUTION SYSTEM Flat Oval Ducting : Supply, fabrication, Installation, testing and commissioning of factory fabricated single walled elliptical ducts using G.I Sheets (120GSM coating) as per IS 655 or SMACNA standard with internal insulation.The price shall include factory fabricated turning vanes, splitter dampers, supports, access door etc.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
The scope includes the supply, installation, testing, and commissioning of a CO₂-based Demand Controlled Ventilation (DCV) system comprising wall-mounted CO₂ sensors on all the cabins, Variable Air Volume (VAV) terminal units rated for 250 CFM airflow, and compatible VAV actuators, along with all associated wiring, control logic, and integration to the Building Management System (BMS). Each CO₂ sensor shall monitor indoor carbon dioxide levels and dynamically regulate the fresh air VAV damper based on real-time occupancy load. When CO₂ concentration exceeds the preset threshold (typically 1000 ppm), the corresponding VAV damper shall modulate to open, allowing increased fresh air intake. Once the CO₂ levels return to acceptable limits, the damper shall modulate to a reduced position or close as required, maintaining optimal indoor air quality (IAQ) while conserving energy. The complete system shall be fully compatible with the building’s BMS and Digital Twin platform. The CO₂ sensors shall be factory-calibrated, non-dispersive infrared (NDIR) type with automatic baseline correction, and feature Modbus/BACnet output for real-time IAQ feedback. Acceptable makes include: Vaisala – GMW90 Series, Belimo – 22RTM Series, Siemens – QPA2000 Series, Honeywell – C7232/TR40-HLCD Series. The VAV terminals shall be low-leakage, pressure-independent type, suitable for ceiling or duct mounting, with an airflow capacity of 250 CFM. Acceptable makes for VAV terminals include: Trane, Johnson Controls (JCI), Trox, Ruskin. All VAVs shall be fitted with compatible, modulating-type actuators capable of operating in response to the CO₂ sensor signal. The actuators shall support analog 0–10V or BACnet communication and include feedback signals for position monitoring. Acceptable actuator makes include: Belimo – LMV/NMV Series, Siemens – GDB/GMA Series, JCI – M9100/M9200 Series, Honeywell – ML7420/ML6435 Series. The cost shall include all materials, labor, sensors, actuators, dampers, controls, signal cabling, mounting accessories, and necessary programming. The entire system must be factory-supported for integration with the project’s smart building environment and be covered under a comprehensive warranty and OEM support. All work shall be executed as per OEM guidelines, project specifications, and good HVAC engineering practice. Installation shall ensure no air leakage or vibration transmission, and the system shall be commissioned in the presence of the Engineer-in-Charge . 50-250 CFM
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, supports etc. duly hanged/ suspended by steel wire ropes as per approved drawings and specifications of following sheet thickness complete as required.
24 Gauge
22 Gauge
20 Gauge
18 Gauge
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with volume control damper as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supply, fixing, testing and commissioning of Multicone Jet Diffuser. 400mm
Supply, fixing testing and commissioning of Jet Nozzle. 315mm
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specification.
Fire Damper
Actuator with smoke sensor and its controller.
Supply, installation, testing and commissioning of GI volume control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc. as per specifications.
Supply & fixing of Fresh/Exhaust Air Intake Aluminium louver with Bird screen & Aluminium VCD.
Supply & fixing,testing and commissioning of powder coated MS exhaust Valve.
Temperature-Based Pressure Independent VAV System for Cabins The scope includes the supply, installation, testing, and commissioning of factory-assembled, pressure-independent Variable Air Volume (VAV) terminal units for temperature control in individual office cabins. Each VAV unit shall be complete with a motorized damper, precision-mounted damper actuator, silencer section for acoustic control, digital thermostat, controller, and all necessary electrical and control accessories. The system shall be suitable for integration into a modern HVAC control architecture and compatible with the project’s BMS and Digital Twin platforms. The VAV boxes shall be pressure-independent type, equipped with an airflow sensor, and capable of maintaining consistent airflow irrespective of duct pressure fluctuations. The VAV damper shall be low-leakage, electronically controlled, and factory-calibrated for the specific airflow range indicated in the construction drawings. Each VAV unit shall include: Motorized damper with actuator (accepting 0–10V or digital input and providing position feedback), On-off cooling digital thermostat for occupant-based temperature control, Controller capable of processing the thermostat signal and modulating the damper actuator accordingly, Internal sound attenuator/silencer for noise reduction and acoustic comfort, Power supply unit (230V, 50Hz) prewired for seamless operation, All required control wiring, cabling, and interconnections between thermostat, actuator, and controller. The thermostat shall be a user-accessible, wall-mounted digital device with intuitive interface and temperature setpoint control. It shall operate in on-off cooling mode and be capable of maintaining space temperature within ±1°C accuracy. VAVs shall be capable of responding promptly to load variations while maintaining thermal comfort, energy efficiency, and quiet operation. Acceptable makes for the VAV terminal units and components include: VAV Boxes: Trane / Johnson Controls (JCI) / Trox / Ruskin. Actuators: Belimo / Siemens / JCI / Honeywell. Thermostats: Honeywell / Siemens / Schneider / JCI. All components must be factory-calibrated and assembled, with documented performance test data. Installation shall ensure correct damper orientation, proper airflow direction, and secure vibration-free mounting. The VAV terminals shall be installed in accordance with manufacturer recommendations, with accessible provisions for maintenance and calibration. Commissioning shall include full system verification: thermostat response testing, damper modulation, airflow measurement, and communication integrity with the BMS. The contractor shall submit datasheets, wiring diagrams, and calibration certificates for all units prior to commissioning approval. The entire system shall be designed to ensure thermal comfort, acoustic performance, energy efficiency, and seamless occupant control within the cabin zones. The VAV CFMs can be refered from HVAC drawing
INSULATION WORK Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Nitrile rubber with anti microbial product protection as per technical specifications
Supplying and fixing of following thickness duly laminated aluminum foil EPDM insulation on existing duct after applying two coats of cold setting adhesive . The joints shall sealed with 50 mm wide and 3 mm thick self adhesive Aero tape insulation complete as per specifications and as required. 9mm thick
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms & AC plant rooms with 50mm thick, density 32kg/cu.m resin boned glass fiber insulation friction fixed in 610mm x 610mm frame work made of 25x50x50x50x25mm made of of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. .
VENTILATION INLINE AND PROPELLER FANS Supply, installation, testing and commissioning of propeller fans and inline fans for exhaust complete with motor suitable for 220 volts 50 Hz, single phase AC supply with supporting arrangement etc. as required at site and as per specifications
PROPELLER FANS WITH GRAVITY LOUVERS,CONECTION PIECE ETC.
Supply, Installation, Testing & Commissioning of AXIAL FANS as per specifications. Fan shall be direct driven VANE AXIAL/TUBE AXIAL FLOW FAN AMCA Certified (For Air and Sound Performance).Fan motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply of class 'F'/'H' insulation. The fan shall be equipped with mounting bracket for the installation of the fans. Fan static pressure shall be as indicated. All vane axial fans motors shall be of minimum IE3 efficiency. Fan total efficiency should not be less than 70 % & noise level should not be more than 75 dbA @ 3 m distance for fans when measured in hemispherical reverberant room conditions. Sound attenuators of appropriate length shall be included in the cost to achieve the desired result if required. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. 'H' Class Insulation 'Emergency Mode Smoke Exhaust Fan
44000 CFM , 40 mm SP
42000 CFM , 40 mm SP
39000 CFM , 40 mm SP
34000 CFM , 40 mm SP
31000 CFM , 40 mm SP
30000 CFM , 40 mm SP
29000 CFM , 40 mm SP
22000 CFM , 40 mm SP
21000 CFM , 40 mm SP
19000 CFM , 40 mm SP
17500 CFM , 40 mm SP
14000 CFM , 40 mm SP
13000 CFM , 40 mm SP
12500 CFM , 40 mm SP
12000 CFM , 40 mm SP
11500 CFM , 40 mm SP
11000 CFM , 40 mm SP
9000 CFM , 40 mm SP
Emergency Mode Supply Air Fan
44000 CFM , 40 mm SP
42000 CFM , 40 mm SP
39000 CFM , 40 mm SP
34000 CFM , 40 mm SP
31000 CFM , 40 mm SP
30000 CFM , 40 mm SP
29000 CFM , 40 mm SP
22000 CFM , 40 mm SP
21000 CFM , 40 mm SP
19000 CFM , 40 mm SP
17500 CFM , 40 mm SP
14000 CFM , 40 mm SP
13000 CFM , 40 mm SP
12500 CFM , 40 mm SP
12000 CFM , 40 mm SP
11500 CFM , 40 mm SP
11000 CFM , 40 mm SP
9000 CFM , 40 mm SP
19500 CFM , 40 mm SP (Staircase Pressurization)
10000 CFM , 40 mm SP (Lift Lobby Pressurization)
8500 CFM , 40 mm SP (Lift Lobby Pressurization)
9500 CFM , 40 mm SP (Lift well Pressurization)
8500 CFM , 40 mm SP (Lift well Pressurization)
Normal Mode Exhaust Air
44000 CFM , 25 mm SP
44000 CFM , 25 mm SP (DG Room)
42000 CFM , 25 mm SP
31000 CFM , 25 mm SP
31000 CFM , 25 mm SP (Plant Room)
30000 CFM , 25 mm SP
29000 CFM , 25 mm SP
34000 CFM , 25 mm SP (STP)
25000 CFM , 25 mm SP (Electrical sub Station))
8000 CFM , 25 mm SP (Domestic Pump Room)
7000 CFM , 25 mm SP (Fire Pump Room)
Normal Mode Fresh Air Fan
44000 CFM , 25 mm SP
44000 CFM , 25 mm SP (DG Room)
42000 CFM , 25 mm SP
31000 CFM , 25 mm SP
31000 CFM , 25 mm SP (Plant Room)
30000 CFM , 25 mm SP
29000 CFM , 25 mm SP
34000 CFM , 25 mm SP (STP)
25000 CFM , 25 mm SP (Electrical sub Station))
8000 CFM , 25 mm SP (Domestic Pump Room)
7000 CFM , 25 mm SP (Fire Pump Room)
Dry Scrubber Units Supply, Installation, Testing and Commissioning of Dry Scrubber each comprising of electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications and as follows: Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh filters, stainless steel spiked ionizers to create high voltage DC field, aluminum collector plates which should be alternatively charged positive and negative with large collecting area with 14" deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% in single pass as per ASHRAE test method. Electrostatic Precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. Collector cell should be of permanent type and incorporate slide out facility for easy removal for cleaning. Power supplies shall be 100% solid state UL/CE Listed, Module of capacity above 3000 CFM shall be equipped with Pulse width modulating (PWM)The system should be fitted with interlock switch for safety. The system should allow connection to a fan section to achieve 500 FPM velocity across the air cleaner. Providing and fixing activated carbon panel filters in the existing filter frame work for removal of Gaseous Pollutants, Odours and particles in exhaust air system for Kitchen as per specifications for following capacity. The unit shall be BMS compatible.The unit shall have direcet driven AXIAL FAN fan (AMCA Certified) including all necessary accessories to complete the installation. 45000 CFM,Static Pressure 65 mm WG
FAN SECTION (FOR TOILET EXHAUST AIR) Supply, installation, testing and commissioning of Double Skin Fan Section Unit fabricated out of extruded aluminium section with 0.6mm precoated galvanized steel sheet outside and 0.6mm plain sheet inside with 23mm thick PUF insulation complete with Backward Curved aerofoil blade Centrifugal DIDW fan complete with Class-F insulation IP 55 TEFC Sq. Cage Induction Motor of 1440 RPM suitable for 415 volts +10%, 50Hz +3%. Motor foot mounted type with access panel,Starter panel , drain plug, inlet screen, flexible connections, drive package, base frame accessories etc. suitable to operate in location exposed to atmosphere as required at site and as per specifications of following capacity :-
12000 CFM,Static Pressure 45 mm WG
16000 CFM,Static Pressure 45 mm WG
Design, development, and turnkey implementation of a Digital Twin platform integrated with field-verified As-Built BIM models. The system shall support up to 16,000 BACnet/IP points and shall be fully compliant with the technical specifications outlined in the tender. Scope includes real-time integration of BMS data, BIM-based asset visualization, performance analytics, fault diagnostics, and AI-driven facility insights. The platform shall be cloud-hosted with secure remote access and mobile compatibility. All associated costs for platform licensing, cloud hosting, support, and software updates shall be included for a period of two (2) years from the date of commissioning.
Providing, fixing, testing, and commissioning of a Electro-magnetic type - Integration with BMS for DM water lines, including a bypass line arrangement and all required accessories, complete in all respects. Capacity to measure the flow
IBMS (INTEGRATED BUILDING MANAGEMENT SYSTEM) Server for BMS software & Networking Components
Supply, installation, testing and commissioning of BMS server and Billing Server i) Intel Dual core generation i7 processor,4MB Cache memory or higher Grade server machine with requried OS as Recommended by OEM ii) 64GB of RAM,(Internal memory) iii) 4GB Graphics card capable of 128X1024 pixel resolution. iv) 1 TB Hard disck drive v) Multimedia keyboard vi) Windows 7 OS Professional Enterprise or latest or OS as recommended by OEM of BMS vii) 50 inch.LED Monitor -Print copy & scan feature -Print Speed-30PPM -Print Memory-1GB -Connectivity-10/100 Base T Ethernet,USB 3.0 Laserjet A4 Black and White printer
Supply, installation, testing and commissioning of Layer 2 managed Gigabit switch, with SFP port if required fiber connectivity. The switch shall have 2 RSTP enabled ports to communicate with other switches to built a star topology network with redundancy on CAT6 armourded UTP cable within the building complete as per specifications with all necessary accessories such as Network rack, LIUs, Patch panel, patch cords etc complete in all respect, and as required for BMS DDC Panel Networking.
Supply, installation, testing and commissioning of hand held portable operator terminals (POT) minimum 7 inch. TFT display with capacitive touch screen type, shall be able to alarms , parameters etc. POT shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. POT With all required connectors etc as per technical specification etc.
BUILDING MANAGEMENT SYSTEM and POWER MANAGEMENT SOFTWARE
Supply, installation, testing and commissioning of the following window based graphical software for IBMS system with 5 No. concurrent Client for Operator workstation. .The Software shall have 3D & HD vector dynamic graphics with Autocad import of plan with Zoom In & Zoom Out facility, Native 64 Bit System Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc.The Software shall be considered with 16000 nos of points and 5 concurrent Client License. The EMAIL/SMS Feature should be avalible for transmititng critical alarms. GSM Module shall be in scope of Vendor.Should have latest software security features
Supply, installation, testing and commissioning of the following window based Energy Billing Software for 300 BTU Meter, 300 Energy Meter , 300 Water Meter
PROGRAMMABLE & APPLICATION SPECIFIC CONTROLLER (DDC) Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, real time clock, peer to peer communication, interoperable DDC as per the specification. The controller shall have inbuilt Ethernet Port, WLAN interface and Cloud Connectivity. Each controller shall have the capability to expand IOs by adding Input/Output Modules. The controller shall have inbuilt port catering integrations Modbus RTU , Modbus TCP. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Each controllers shall have spare capacity of 15% for future expansion. The above shall be housed in vandal proof, lockable & secure Enclosures (IP65 for Outdoor and IP54 for Internal spaces) strictly as per Make List to be supplied along with all necessary switchgear, SMPS, Step down Transformer, protection relays as required.
Controller for Chillers , Primary Chilled Water Pumps & Variable Speed Pumping system, Condenser and Cooling Tower
Controller for CS Air Handling Unit with VFD (Max 2 DDC per AHU)
Controller For FM Air Handling Unit with ERW ( 1 DDC per AHU)
Controller for TFA with VFD (Max 1 DDC per TFA)
Controller for Ventilation Fans (Max 4 Fans per DDC)
Controller for Dry Scrubber (Max 2 per DDC)
Controller for Transformer & DG Set
Controller for Fire Fighting
Controller for Plumbing ( 4 Pumps per DDC )
Controller for Sump Pumps ( 4 Pumps per DDC )
Controller for Tanks
SYSTEM INTEGRATION UNITS FOR 3RD PARTY SYSTEM SOFTWARE INTEGRATION
Supply, installation, testing and commissioning of True IP Based for third party integration. The controller shall have atleast 1 port Ethernet switch, WLAN interface and Cloud Connectivity. It should Support of the major communication protocols: BACnet/IP, BACnet MS/TP, Modbus IP and Modbus RTU . Integration of Chiller System and VFD as per IO summary Integration of Variable Speed Pumping system as per IO summary Integration of AHU & TFA VFD as per IO summary Integration of Energy Meters as per IO summary Integration of Solar Invertors as per IO summary Integration of DG Sets as per IO summary Integration of Lifts as per IO summary Integration of UPS as per IO summary Integartion of Fire Alarm System as per IO summary Integration of Electrical System Scada Integration of STP PLC on Modbus over RS485 as per IO summary Integration of Hydropenumatic Pumps on Modbus over RS485 as per IO summary Integration of BTU Meter vendor to consider Maximum 25 BTU meters in one intergrator Integration of water Meter vendor to consider Maximum 25 Water meters in one intergrator
SENSORS AND FIELD DEVICES Supplying, installing, testing and commissioning of the following sensors / transducers / transmitters.
Immersion Temperature Sensor along with Thermowell Measurement accuracy At -30...130 °C: ±0.95 K
Ambient Temp & Humidity sensor
Electromagnetic type Flow meter - 300 MM
Differential Pressure Switch Water
Level Switch for Cooling Tower
Current relay
Differential Pressure Switch for Air
Duct temprature Sensor
Duct temprature & RH Sensor
Duct Static pressure Sensor
Duct CO2 Sensor
Water Pressure Sensor
Bi-Level switch
Voltage Transducer
Flame proof Level Switch
WIRING & CONDUITING
Supplying, laying, termination, testing and commissioning of 2 Core x 1 sq mm PVC insulated, Annealed Tinned Copper, twisted, shielded, armoured FRLS cable.
Supplying, laying, termination, testing and commissioning of 4 Core x 1 sq mm PVC insulated, Annealed Tinned Copper, twisted, shielded, armoured FRLS cable.
Supplying, laying, termination, testing and commissioning of 8 Core x 1 sq mm PVC insulated, Annealed Tinned Copper, twisted, shielded, armoured FRLS cable.
Supplying, laying, termination, testing and commissioning of 2 Core x 1.5 sq mm PVC insulated, Annealed Tinned Copper, twisted, shielded, armoured FRLS cable.
Supplying, laying, termination, testing & commissioning of CAT 6 armoured Cables with required accessories like RJ45 connector etc.
GI Flexible conduit for termination in the DDC Panels
Supplying, installing, testing and commissioning of GI perforatedHot Dipped cable trays of the following sizes complete with angle iron supports/hanging arrangement etc
300 mm x 50 mm x 2 mm
200 mm x 50 mm x 2 mm
150 mm x 50 mm x 2 mm
CCTV System SITC of 5MP IR Vandal Proof Dome Network Camera Lens Size: 3.0mm – 13.5mm motorized vari-focal lens, Aperture F1.4 – F3.2, NDAA Compliance approved, Security: SSL Encryption, Multi-User Authority, IEEE802.1x, IP Filtering, HTTPS , IR Distance : 30M IR, Memory Support : Micro SD 512 GB, Two-way Audio Communication supported, Audio Compression Algorithm: ADPCM 16K, G.726, G.711 u-Law, G.711 a-Law DC12V/PoE, IP67 and K10 rating, Image Sensor: 1/2.8” CMOS Maximum Resolution: 2592 x 1944, 11, Video Resolution: 4:3 : 2592x1944, 1920x1440, 1280x960x 640x480, 16:9 : 2592x1456, 1920x1080, 1280x720, 640x360, Video Compression : H.265, H.264, Dynamic Range: 120dB, True Day & Night: Yes (ICR) MJPEG Scanning Mode: Progressive Scan COLOR : 0.15 lux @ F2.0 B/W : 0 lux (IR LED ON), Shutter Speed (Auto) 1/10000s~1s, True day/night, WDR 120db, 3D DNR, HLC & BLC, Quadruple streams, Camera shall confirm ONVIF Profile S, Smart codec by ROI, MTBF time 1,25,000 Hours @40 degree (Report to be submitted), Inbuilt Analytics Motion Detection, Alarm in, Tampering and Trip Zone, Shall provide Quadruple streams, Object , SSL Encryption, Multi-User Authority, IEEE 802.1x, IP Filtering, HTTPS , Operating Temperature: -40°C ~ +55°C (-40°F ~ +131°F) , Operating Humidity: 0% to 90% non-condensing, Certification: BIS/UL, FCC, CE approval. MAC Address: The MAC address of the proposed IP cameras must be registered in the same name of the OEM. The IP Camera OEM must confirm that the MAC address of the surveillance cameras; OUI must be in the name of the OEM. etc complete Approved Make: Axis / IDIS / Mobotix / Sony
5MP IR Vandal Proof Bullet Network Camera Lens Size: 3.0mm – 13.5mm motorized vari-focal lens,Aperture F1.4 – F3.2, NDAA Compliance approved, IR Distance : 30M IR, Memory Support : Micro SD 512 GB, Security: SSL Encryption, Multi-User Authority, IEEE802.1x, IP Filtering, HTTPS , Two-way Audio Communication supported, Audio Compression Algorithm: ADPCM 16K, G.726, G.711 u-Law, G.711 a-Law DC12V/PoE, IP67 and K10 rating, Image Sensor: 1/2.8” CMOS Maximum Resolution: 2592 x 1944, 11, Video Resolution: 4:3 : 2592x1944, 1920x1440, 1280x960x 640x480, 16:9 : 2592x1456, 1920x1080, 1280x720, 640x360, Video Compression : H.265, H.264, Dynamic Range: 120dB, True Day & Night: Yes (ICR) MJPEG Scanning Mode: Progressive Scan COLOR : 0.15 lux @ F2.0 B/W : 0 lux (IR LED ON), Shutter Speed (Auto) 1/10000s~1s, True day/night, WDR 120db, 3D DNR, HLC & BLC, Quadruple streams, Camera shall confirm ONVIF Profile S, Smart codec by ROI, MTBF time 1,25,000 Hours @40 degree (Report to be submitted), Inbuilt Analytics Motion Detection, Alarm in, Tampering and Trip Zone, Shall provide Quadruple streams, Object , SSL Encryption, Multi-User Authority, IEEE 802.1x, IP Filtering, HTTPS , Operating Temperature: -40°C ~ +55°C (-40°F ~ +131°F) , Operating Humidity: 0% to 90% non-condensing, Certification: BIS/UL, FCC, CE approval. MAC Address: The MAC address of the proposed IP cameras must be registered in the same name of the OEM. The IP Camera OEM must confirm that the MAC address of the surveillance cameras; OUI must be in the name of the OEM. etc complete Approved Make: Axis / IDIS / Mobotix / Sony
5/8 MP Fish Eye Camera Image Sensor 1/2.3" CMOS Pixel Resolution 8MP resolution,Video Compression Licensed HEVC H.265, H.264 (MP) M-JPEG, Lens 1.6mm , Streaming Capability Quadruple streaming ( All stream should Support H.265 Compression) Supported resolutions 2944x2944, 2208x2208, 2944x1472, 1472x1472, 768x768, 736x736, 768x384, Resolution and Frame Rate 30ips : 2944 X 2944 (WDR), 15ips: 2944 x 2944 (WDR), Bit Rate H.265 VBR / CBR, Activity/Motion Controlled Video Recording During negligible to no motion, Minimum, Illumination Colour Mode 0.3Lux, Black & White Mode 0 Lux IR LED On Day/Night Camera Auto, IR Distance 15 mtr Mirroring / Pivot, Horizontal/Vertical, AI Trigger Video Motion Detection, Active Tampering, Alarm, Trip Zone, Heatmap, Meta Filtering (Combination Search Human/Vehicle & Color), Privacy masking 8 Zones Alarm Inputs / outputs 1 input & 1 output, Input Voltage Power should be drawn on PoE, 220V AC Voltage (Nominal) / 24V AC or DC/12V DC POE - IEEE 802.3af/at compliant Operating Temperature -20°C ~ +50°C Operating Humidity 0% ~ 90% RH non-condensing Outdoor Ready To be supplied with IP67 & IK10 Housing, Edge Storage Should support 512GB SDXC,Security SSL Encryption, Multi-User Authority, IEEE802.1x, IP Filtering, HTTPS, MTBF: 1,25,000 Hours MTBF Report to be submitted @40Deg C, Certification: BIS/UL, FCC, CE Approval, MAC Address: The MAC address of the proposed IP cameras must be registered in the same name of the OEM. The IP Camera OEM must confirm that the MAC address of the surveillance cameras; OUI (must be in the name of the OEM. etc complete Approved Make: Axis / IDIS / Mobotix / Sony
SITC of 8 MP PTZ Camera Image Sensor 1/1.8" or larger, Progressive scan, CMOS sensor Pixel Resolution 8MP resolution, Video Compression Licensed HEVC H.265, H.264 (MP) M-JPEG Lens 6 ~ 202mm MVF Angular Field of View Wide : 63.0⁰(H), 36.0⁰ (V), 66.1⁰ (D), Tele : 2.4⁰ (H), 1.3⁰ (V), 2.6⁰ (D) Image Stabilizer Auto, Pan Range 360° (Endless) Pan Speed Pan: 0.02~240º/sec (preset 360º/sec), Tilt Range 200º (-10~190º) Tilt Speed Tilt: 0.02~240º/sec (preset 360º/sec), Preset 256 Streaming Capability Quadruple streaming ( All stream should Support H.265 Compression) Supported resolutions 3840 x 2160, 1920x1080, 1280x720, 640x360, Resolution and Frame Rate :30ips / 25fps : 3840 x 2160 (WDR), Bit Rate H.265 VBR / CBRr, Activity/Motion Controlled Video Recording : During negligible to no motion, Minimum Illumination Colour Mode 0.001 Lux Black & White Mode 0 Lux, Video Streaming Unicast and Multicast streams: IR Distance 300 mtr, Shutter speed 1/30 ~ 1/10000 sec or higher, WDR True WDR (120dB), Storage: 512 GB Memory Card , Camera Tampering Active Tampering Alarm Recording Session Buffer Yes (Up to 60MB), Security SSL Encryption, Multi-User Authority, IEEE802.1x, IP Filtering, HTTPS, MTBF time 1,25,000 Hours @40 degree (Report to be submitted), Web Server Internal Web server required with embedded operating system, Privacy masking 8 Zones Edge Analytics Video Motion Detection, Active Tampering Alarm, Trip Zone Alarm Inputs / outputs Input 8ea / Output 2ea, Input Voltage Power should be drawn on PoE, 220V AC Voltage (Nominal) / 24V AC or DC/12V DC , POE - IEEE 802.3af/at compliant, Operating Temperature -40°C ~ +50°C, Operating Humidity 0% ~ 90% RH non-condensing. Certifications: BIS / UL, FCC, CE approval, MAC Address: The MAC address of the proposed IP cameras must be registered in the same name of the OEM. The IP Camera OEM must confirm that the MAC address of the surveillance cameras OUI must be in the name of the OEM. etc complete Approved Make: Axis / IDIS / Mobotix / Sony
SITC of 64 Channel IP network video recording capability Rack mount NVR with Redundant Power Supply and minimum 8 Slots, should support H.264/H.265 compression, network incoming throughput of 850 Mbps and 12MP recording resolution, time division multiplexing, real time recording of multiple cameras, storing digitized and compressed images on internal hard disk drives for fast search and retrieval either locally at the unit, or from a remote workstation using a Graphical User Interface (GUI), should allow all connected cameras to be discovered and configured automatically, simultaneous live view, record, play back, data transmission in real time, maximum throughput of 400 Mbps, UHD 1920 ips, support H.264/H.265 compression, 2X – 12X digital zoom in live view mode, 2X – 12X digital zoom in playback mode, time lapse, event, time lapse + event, pre / post-event, panic recording schedule, recording bitrate control mode: CBR and VBR, alarm, audio, motion, trip zone, video loss, text-in, system event triggering, fan error, record failure, storage related alerts and alarm in error, email, remote notification (call back) to remote work stations, mobile device push notification, Time-lapse, Event log, Motion, Thumbnail, Text-in search options, SSL, Password encryption options, network keyboardfor controlling the NVR and PTZ, 1 Gigabit Remote Client port, 4 Gigabit ports, ONVIF compliant , output interface 1 HDMI (up to 4K), 8 internal SATA ports (10TB per SATA) with recording capacity up to 80 TB or more , RAID support as 1,5,10 - user may choose & configure as per security needs on internal SATA , redundant dual power supply as failover,2 x USB for backup /upgrade etc., complete as required. The NVR should have internal Admin service, monitoring servics, Left object detection. In addition the NVR should be compatible to AI cameras, ANPR cameras for future. The NVR should also support Failover services in 10:1mode. Certification: BIS/UL, FCC, CE etc complete Approved Make: Axis / IDIS / Mobotix / Sony
SITC of surveillance drives are tuned for 24×7 workloads in capacities up to 10 TB equipped with enhanced image perfect firmware etc all complete Approved Make:Seagate / WD / Toshiba
SITC of Server PC Intel I7 Xeon Quad Processor with 2 x 8GB RAM , 1 Tb HDD, TFT Display , Keyboard, Mouse complete all accessories etc all complete Approved Make: Dell / HP / lenovo
SITC of 55" Professional Ultra HD Display Panel, 4K UHD (3840x2160) Resolution, Brightness 400 Nits, Dynamic Contrast Ratio: 500000:1, Viewing angle (horizontal / vertical): 178 / 178 degree, Display Colours: 1.07 Billion, Panel technology: IPS / Direct LED, Contrast ratio (typical) 1200:1, Connectivity: Video Input: 2 HDMI 2.0, 2 USB 2.0, DVI-I, Audio In, Audio Out, COntrol: RS232, Ethernet, 2x10W Built-in speakers, with Android Internal Player with 32 GB Storage and 2GB DDR RAM, CE, FCC, Class A, BIS Certified etc all complete Approved Make: Philips / Samsung / LG / Christie
Access Control System SITC of Web Based Enterprise level Application including Time Attendance-Access Control, GUI, Antipass back, Reports in Inbox, with Unlimited Users, Door Scheduling, Unlimited Client logins, Event Notification, POP ups, Mustur Points, Area Control, Time base access and alerts. Software should be VAPT approved and should provide per reader license, Sofware should expandable and scalable and have capability in future integration of Elevator management, Template management and card priting ,Integrated credential issuance application inclusive of card template designing, card printing, finger print enrollment, key management, contactless card reader/writer & contact card reader/writer, Software shall support Access IP and Interface Controllers & Card Readers, Biometric Readers & Enrolment Devices, Card Printers, Card Encoding Devices, Smart Cards, Mobile/Digital Credentials, BLE/NFC based access readers, as per site etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Integrated Visitor Managment System a.Mandatory fields for visitor pass issue b. Whether appointment is must for every visitor c. Whether Access Card issue to visitor is compulsory d. Whether visitor request to be approved by the group administrator e. Whether Email based approval f. Sending of Email/SMS to the approved visitor g. Sending Email/SMS to the employee on visitor arrival h. Pop up on Employee’s system on visitor arrival i. Banned visitor notification j. Lapse Time (Time after which appointment will get expired) k. Default Departure Hours (if some other time is not set) l. Pre Appointment hours ( Time before the scheduled appointment during which pass can be generated) etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Access IP Controller with Enclosure and Power Supply: 2 Door 4 Reader with RS485 OSDP, Security Features: Authorized IP address filtering, IP Client Proxy Host communications protected by TLS 1.2/1.1 or AES 256/128; Crypto memory chip, IO Expansion connection protected by AES Capacity: Cards/Users : 240000 Offline Event Log: 5,0000 & Communications Built in TCP/IP, IPV4, IPV6, RS-485, Inputs: Eight unsupervised/supervised, Two unsupervised dedicated for cabinet tamper and UPS fault monitoring, Outputs: Four relays, Power : 12 to 24 Vdc 10 %, 500 mA maximum , Supports up to 520 inputs and 516 outputs, 16 card formats per active reader, 8 per offline reader, Open Supervised Device Protocol (OSDP) and OSDP SC compliant, Anti-passback support, Area-based, reader-based, or time based Nested area, hard, soft, or timed forgiveness, Encrypted database, Supports up to nineteen (19) digit card numbers, Intrusion Alarm Functions: Area monitoring, Standard alarm masking , Fire Integration; open all doors from hardware itself, Temperature: -55 to +85 °C, storage, 0 to +70 °C, operating, Humidity: 5 to 95 % RHNC, Micro USB Port, SD card upto 8 GB. Certifications:UL294 Recognized, FCC Part 15 Class A, CE Compliant, RoHS, NIST Certified Encryption etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Interface Controller of 2 Door 4 Reader with onboard OSDP SC, connects to the Master/Network Controller. (OSDP SC) and 2 Doors. Fire Integration; open all doors from hardware itself Power : PoE (12.95 W), compliant to IEEE 802.3af or PoE+ (25 W), compliant to IEEE 802.3at or 12 VDC ± 10 %, 1.7 A maximum. UL 294 Recognized, FCC Part 15 Class A, CE Compliant, RoHS (2011/65/EU & 2015/863), EU REACH (1907/2006), California Proposition 65 etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Bluetooth Enabled Smart Card Redaer, OSDP Compliant Technology: Contactless Smart Card, Frequency : 13.56 MHz Operating temperature -35 to 65Deg C. IP55 Rating. Current Draw 60 @ 16V, Certifications:FCC, CE Audio Tone Built-in piezo sounder Visual annunciation Bi-color LED etc. all complete.Certifications UL294/cUL (US), FCC, IC, CE,C-Tick, MIC, NCC Hosuing Material UL94 Polycarbonate etcas per specifications etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Biometric Machine, user identification in 1 secondminimum 500/1000 users and Expandanbe up to 10,000 users (30,000 templates) in 1:N identification mode, 2.8” QVGA color touchscreen and buzzer 250,000 IDs in authorized user list, 1 Million logs. CPU: ARM® Cortex-A9 core 1GHz, Linux Operating System, Fake finger detection, Duress finger, FBI PIV IQS certified optical fingerprint senso, Network/Communication: - Ethernet, RS485, USB, Wiegand and OSDP support ,Integrated Smart Card Reader, Internal storage capacity: 512MB Flash, 512MB RAM, Operating conditions: - Temperature: -20°C to 55°C (-4°F to 131°F) - Humidity: 10% to 80% (non condensing), Ingress protection: IP65, EMC/Safety standards: - CE, CB, FCC, BIS - UL294 , RoHS, REACh and WEEE etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Smart card Frequency Excitation (13.56 MHz) Mifare smart Card , distance upto 2.5" Memory Type EEPROM, 2K bit memory Complies with ISO/IEC standards for thickness. Lifetime Warranty .etc. as per specifications etc all complete Approved Make:ID Cube / Maxxess / IDEMIA - Morpho / HID / Apollo
SITC of Touchless IR Based Exit Push Button Stainless Steel etc. as per specifications etc all complete Approved Make:TRIMAC / KRITECH / ASSA ABLOY / NEDAP
SITC of Emergency Glass Break Unit Single Pole as per specifications etc all complete etc all complete Approved Make:TRIMAC / KRITECH / ASSA ABLOY / NEDAP
SITC of Electro Magnetic Lock Single Leaf as per door design, Fail safe type, Holding force: 272kg(600lbs), Inbuilt Door contact , Current Drain:320mA/12VDC, Built-in voltage spiker suppressor to protect the lock body and equipments, lock body and armature with chemical plating anticorrosion finished, With LED light & brackets UL Listed etc.as per specifications etc all complete Approved Make:TRIMAC / KRITECH / ASSA ABLOY / NEDAP
SITC of Electro Magnetic Lock Double Leaf as per door design, Fail safe type, Holding force: 272kg(600lbs), Inbuilt Door contact , Current Drain:320mA/12VDC, Built-in voltage spiker suppressor to protect the lock body and equipments, lock body and armature with chemical plating anticorrosion finished, With LED light & brackets UL Listed etc. as per specifications etc all complete Approved Make:TRIMAC / KRITECH / ASSA ABLOY / NEDAP
SITC of Recording / Admin Server : Intel® Xeon® Processor silver, 1.6Gz, 8C/16T Processor OR similar, OS- Windows 2016 Server or latest, Redundant Power Supply, Memory - 8GB RAM (1 x 8GB DDR4-2666MT/s RDIMM), Network Connection - 4 GbE RJ-45 Ports (1000Base-T) with 24" 4K Screen etc. all complete Approved Make:Dell, HP, Lenovo
SITC of 4 core .75 Sqmm shielded RS485 OSDP communication multi-stand Data Cable (Quantity in running Meter) etc all complete Approved Make:Finolex, Delton, Excel, Polycab
SITC of 4 core .75 Sqmm shielded communication multi-stand Data Cable (Quantity in running Meter) etc. as per specifications etc all complete Approved Make:Alcatel Lucent, Cisco, NEC
Audio Visual system SITC of Indoor LED Video Wall Screen, Size: 6 Meter x 3.38 Meter or more, 4K UHD (3840x2160) Resolution or more, 1.56 MM or less Pixel Pitch, COB LED type, Aspect Ratio 16:9, Pixel Density 409600 pixels / m² or more, Brightness 600 - 1000 nits Adjustable, Color Temperature 3200 ~ 9300K Adjustable, Viewing Angle (H/V): 160 / 160 degree, Brightness uniformity ≥ 97%, Contract ratio 13000:1 or more, Constant current drive, Video Rate 30 - 120 Hz, Refresh Rate ≥ 3840 Hz, Color Depth 16 bits or more, IP65 Rating, Front Service Access, with LED Controlller with HDMI input, Operating Temp - 10° ~+ 40° Celsius degree, Operating Humidity 10%-80% RH mounting arrangement with all reuired accessories etc all compete
SITC of 55" Stage feedback display, 350 nits Brightness, Smart Android OS, 4K UHD Resolution, 16*7, Screen Mirroring through Airplay / Chromecast, Direct LED, 16 Gb storage, Wi-Fi, 178 Degree Viewing Angle, Landscape / Portrait / Tilt Installation, IP / RS232C Control, 10W+10W Speakers, HDMI 2.1 (3), USB (2), Power Scheduling, 1200:1 Contrast Ratio, HDR / HLG with all reuired accessories etc all compete
SITC of Mobile TV Mount Stand, Low Height Monitor Cart with Wheels for 32-75 inch Flat Curved Screen TV, LED LCD, Height Adjustable, 90°Adjustable Viewing Angle with all reuired accessories etc all compete
SITC of Wall plate 2x1 switcher and HDBaseT transmitter with HDMI and USB-C input, Compliant with HDMI 2.0b, HDCP 2.2 and Display Port 1.2a, HDMI input supports 18Gbps video bandwidth; USB-C input supports 5.4Gbps video bandwidth, HDBaseT output can extend video transmission distance up to 230ft / 70m for 1080P@60 or 131ft / 40m for 4K@60 via a single CAT6/6a/7 cable, Support POH function with plate and related accessories etc all complete
SITC of HDBaseT Receiver with HDMI Output and HDMI Input, HDMI input supports 18Gbps video bandwidth, Compliant with HDMI 2.0b, HDCP 2.2 and Display Port 1.2a, Supports 3D, HDR10, HDBaseT output can extend video transmission distance up to 230ft / 70m for 1080P@60 or 131ft / 40m for 4K@60 via a single CAT6/6a/7 cable etc all complete
SITC of 18 Gbps 4×4 HDBaseT Matrix Switcher, 4 HDMI inputs, 4 HDMI & HDBaseT mirrored outputs, HDMI 2.0b, HDCP 2.2 and HDCP 1.x compliant Video resolution up to 4K2K@60Hz (YUV 4:4:4) on all HDMI & HDBaseT ports, HDR, HDR10, HDR10+, HLG are supported, HDBaseT output can extend video transmission distance up to 492ft / 150m for 1080P or 328ft / 100m for 4K2K via a single Cat 6/7 cable, Control via front panel buttons, IR remote, RS-232, LAN, and Web GUI with 4 number of HDBaseT Receiver etc all complete
SITC of Wooden lectern with Dual wired microphone connectivity, 25" table top, with reading lamps, Cable management, Large reading surface as required with cables & connectors as required etc. all complete
SITC of Multi-format Professional Blu-ray player offering DVD/CD, SD card and USB flash memory playback, Supports playback of various video, still image, and audio formats from SD cards (SD/SDHC) and USB memory, HDMI output port equipped, XLR balanced output terminals equipped etc. all complete
SITC of Left, Center and Right FOH Two-way Loudspeaker, Drivers: LF: 15 inch driver with 3.5 in voice coil, HF: 1.5 inch exit, 2.8 inch voice coil, compression driver , Power Capacity (continuous / peak): 500 W / 2000 W, Frequency Response (-6 dB) 55 Hz – 20 kHz, Sensitivity 97 dB (1 W @ 1 m), Max / Peak SPL @ 1 m 130 dB, Frequency Range (-10 dB) 43 Hz – 20 kHz, Coverage Angle 75° conical DMT, Nominal Impedance 8Ω, Trapezoidal, plywood Enclosure etc all complete
SITC of Ceiling supension arrangement for FOH Speaker with all required accessories etc all complete
SITC of High-performance Direct Radiation Subwoofer, 18" LF driver with 4 inch voice coil, Power capacity (continuous/peak): 800 W / 3200 W, Sensitivity 98 dB (1 W @ 1 m), Peak SPL @ 1 m: 133 dB, Frequency Response (-6 dB) 37 Hz to 230 Hz, Frequency Range (-10 dB) 32 Hz to 230 Hz , Nominal Impedance 4Ω, plywood enclousre etc all complete
SITC of Surround / Back Fill Two-way Loudspeaker, Drivers:- LF: 10 inch driver with 2.5 inch voice coil; HF: 1 inch exit, 1.75 inch voice coil, compression driver, Power capacity (continuous / peak) : 300 W / 1200 W, Sensitivity: 95 dB (1 W @ 1 m), Peak SPL @ 1m: 126 dB, Frequency Response (-6 dB): 68Hz – 20kHz, Frequency Range (-10 dB): 50Hz - 20kHz, Coverage Angle: 85° conical DMT, Nominal Impedance: 8Ω, Multi-angle plywood Enclosure with mounting etc all complete
SITC of Front Fill Speaker, 8-inch weather treated woofer; 1.4-inch compression driver, Rated noise power 200 watts, Broadband sensitivity 90 dB SPL, Maximum peak SPL 119 dB, Rated impedance 8 ohms, Transformer taps 70 V: 60, 30, 15, 7.5 W and 8Ω bypass, 100V: 60, 30, 15 W and 8Ω bypass, with X-Mount mounting system etc all complete
SITC of Green Room / VIP Lounge Speaker, 8-inch weather treated woofer; 1.4-inch compression driver, Rated noise power 200 watts, Broadband sensitivity 90 dB SPL, Maximum peak SPL 119 dB, Rated impedance 8 ohms, Transformer taps 70 V: 60, 30, 15, 7.5 W and 8Ω bypass, 100V: 60, 30, 15 W and 8Ω bypass, with X-Mount mounting system etc all complete
SITC of 12-inch Compact Powered Stage Monitor Loudspeaker, 1000 Watt peak power Class-D amplifier module, Maximum Rated SPL: 126 dB, Frequency Response (-6 dB): 49 - 20 kHz, Nominal Coverage Angle: 75° Axisymetric, Frequency Range (-10 dB) 47 - 20 kHz, etc all complete
SITC of Professional Dual Channel Class D Power Amplifier, Output power per channel: 800 W at 8Ω continuous, 1200 W at 4Ω continuous, Signal to Noise (A weighted, 20 Hz–20 kHz): 100 dB, Frequency Response (20 Hz–20 kHz): +0.7 dB, -0.8 dB, Damping Factor (8Ω) 100, Extensive and powerful loudspeaker processing built in. Includes high and low-pass filters, 4-band parameteric EQ, limiting, and delay, Amplifier and Load Protection: hort circuit, open circuit, thermal, RF protection, Load protected against DC faults, UL, CE, RoHS/WEEE compliant etc all complete
SITC of Professional Dual Channel Class D Power Amplifier, Output power per channel: 400 W at 8Ω continuous, 600 W at 4Ω continuous, Signal to Noise (A weighted, 20 Hz–20 kHz): 100 dB, Frequency Response (20 Hz–20 kHz): +0.7 dB, -0.8 dB, Damping Factor (8Ω) 100, Extensive and powerful loudspeaker processing built in. Includes high and low-pass filters, 4-band parameteric EQ, limiting, and delay, Amplifier and Load Protection: hort circuit, open circuit, thermal, RF protection, Load protected against DC faults, UL, CE, RoHS/WEEE compliant etc all complete
SITC of Dual Channel Receiver for Wireless Microphone, Transparent 24-bit digital audio, Extended 20 Hz to 20 kHz frequency range, 118 dB dynamic range, Digital predictive switching diversity, 32 available channels per frequency band, RF Carrier Frequency Range: 470–937.5 MHz, Up to 10 compatible systems per 6MHz TV band; 12 systems per 8 MHz band, Easy pairing of transmitters and receivers over scan and IR sync, Rugged metal construction etc all complete
SITC of Digital Wireless Handheld Microphone, Cardoid Dynamic Vocal Microphone, Transparent 24-bit digital audio, Antenna Type Integrated Single-Band Helica, Working Range 100 m (328 ft), Occupied Bandwidth <200 kHz, Easy pairing of transmitters and receivers over scan and IR sync, Interchangeable microphone capsules, Rugged metal construction with Rechargeable Li-Ion battery etc all complete
SITC of Digital Wireless Body pack with Subminiature Lavalier Microphone, Transparent 24-bit digital audio, Antenna Type Integrated Single-Band Helica, Working Range 100 m (328 ft), Occupied Bandwidth <200 kHz, Easy pairing of transmitters and receivers over scan and IR sync, Interchangeable microphone capsules, Rugged metal construction with Rechargeable Li-Ion battery etc all complete
SITC of Digital Wireless Body pack with Earset Headworn Microphone, Transparent 24-bit digital audio, Antenna Type Integrated Single-Band Helica, Working Range 100 m (328 ft), Occupied Bandwidth <200 kHz, Easy pairing of transmitters and receivers over scan and IR sync, Interchangeable microphone capsules, Rugged metal construction with Rechargeable Li-Ion battery etc all complete
SITC of Dual docking recharging station for lithium-ion batteries in or out of their transmitters. Built to charge two batteries, two body pack transmitters, two handheld transmitters etc all complete
SITC of Antenna distribution system offers 4-way active antenna splitting and cascade port with different frequency versions available, etc all complete
SITC of Omnidirectional Antenna with in line Antenna amplifier with mounting arrangemnts as per site with 100 feet Coaxial Antenna Cable etc all complete
SITC of Wired Dynamic Vocal Microphone, Cardioid, Frequency response: 50 to 15,000 Hz, Rated impedance is 150 Ω (300 Ω actual), Includes integrated on/off switch, swivel adapter and a zippered pouch etc al complete
SITC of Wired Dynamic Instrument Microphone, Cardioid, Frequency response: 40 to 15,000 Hz, Rated impedance is 150 Ω (310 Ω actual), Includes swivel adapter and a zippered pouch etc al complete
SITC of 18 Inch Gooseneck Microphone, With Mute Switch, Frequency Response 50 to 17,000 Hz, Cardioid, Maximum SPL (1kHz at 1% THD, 1 kΩ load) 123 dB, with a desktop base and attached 3 m (approximate)/10 ft cable, Phantom Powered etc all complete
SITC of 16 Pair Junction Box balanced audio snake with 15 Meters Cable & XLR-M, XLR-F, or 1/4″ TRS termination available, Mounting Options etc all complete
SITC of Fully integrated audio, video and control solution, 128 networked audio channels (AES67), 24 channels of analog I/O, including 8 configurable Flex channels, 16x AEC processors, Supports up to 4x Q-SYS NM-T1 network microphones, Up to 32 x 32 Dante audio channels (8 x 8 included), USB AV bridging (16 x 16 audio + Camera support), Full-featured Control engine (with feature license if any), External USB audio device host, Up to 4x VoIP instances etc all complete
SITC of Network I/O Expander for Four RS232 ports (one port also includes RS-485 and RS-422 compatibility), Gigabit LAN connection for Q-LAN, PoE, Ethernet daisy-chaining etc all complete
SITC of Network I/O Expander for Eight general purpose inputs & eight general purpose outputs, Gigabit LAN connection for Q-LAN, PoE, Ethernet daisy-chaining etc all complete
SITC of 10.9-inch iPad Air Wi-Fi 64GB - Space Grey with required software, GUI and Programming required as per site etc all complete
SITC of 16-Port Gigabit Ethernet High-Power Unmanaged PoE+ Switch with FlexPoE (183W), Mount on rack, desktop, or wall etc all complete
SITC of Dual Band Wall/Ceiling Mount, PoE Powered, Local Management etc all complete
SITC of 1 Meter High Speed True 4K HDMI Cable with Ethernet, HDMI (3D, Deep Color, 4K); HDCP 2.2 compliant, HDMI Ethernet Channel functionality etc all complete
SITC of 3 Meter High Speed True 4K HDMI Cable with Ethernet, HDMI (3D, Deep Color, 4K); HDCP 2.2 compliant, HDMI Ethernet Channel functionality etc all complete
SITC of 5 Meter High Speed True 4K HDMI Cable with Ethernet, HDMI (3D, Deep Color, 4K); HDCP 2.2 compliant, HDMI Ethernet Channel functionality etc all complete
SITC of 4.0 sqmm x 2 core Speaker Cable, ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath (as per actaul) etc all complete
SITC of 2.5 sqmm x 2 core Speaker Cable, ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath (as per actaul) etc all complete
SITC of 24 AWG 2 core ATC copper conductor Microphone Cable, core twisted in a circular form, polyester mylar taped, aluminium foil + spiral shielded (97%) with ATC copper (as per actual) etc all complete
SITC of Cat 6 STP Cable with required connector (as per actual) etc all complete
SITC of Floor Box with made of steel and PVC, Configurable with removable modules with all required accesseries etc all complete
SITC of Connector such as XLR Male, Female, Speak-On, XLR Jack for floor box and any other required for above configuration
SITC of 32U, Equipment Rack, with Front & Side doors, 4 No Fan Assembly, on Top of the Rack, 4 Caster wheels, 2 no Shelfs to mount the equipments which are not rack mounted, 8X2, 5/6 Amp. Power Distribution Unit, Cable Manager & Sufficient Rack hardwares etc all complete
SITC of 98" Smart Android 4K UHD Professional Display, Full Array LED, 120HZ Refresh Rate, 780 typical nits/1500 peak nits, Full Array LED, Smart Android, 4K UHD, 24*7, Local Dimming, Airplay/Chromecast, 5000:1 Contrast Ratio, 120HZ Refresh Rate, 32 GB Storage, XR Triluminos Pro, Cognitive Processor XR, 40 W Speakers, 95% color gamut etc all complete Approved Make: Sony, Samsung, LG, Panasonic
SITC of 55" Smart Android 4K UHD Professional Display, 350 nits Brightness, Smart Android OS, 4K UHD Resolution, 16*7, Screen Mirroring through Airplay/Chromecast, Direct LED, 16 Gb storage, Wi-Fi, 178 Degree Viewing Angle, Landscape / Portrait / Tilt Installation, IP / RS232C Control, 10W+10W Speakers, 3 HDMI 2.1 inputs & 2 USB, Power Scheduling, 1200:1 Contrast Ratio. 4K HDR Visual Experience through 4K Processor X1, 4K X-Reality PRO, Motionflow XR, HDR10 / HLG etc all complete Approved Make: Sony, Samsung, LG, Panasonic
SITC of Swivel Mount for Display Panel, with full motion with an angle of 5 degrees (+ or -) and it holds up to 60 kg to fit 55″ to 98″ displays etc all complete Approved Make: Logic, CPMG, Lumi, Btech
SITC of Cable Cubby with slow motion flip- open cover, 2 Universal Power, 2 USB-A Mobile Charger, 2 RJ-45 Network, Pass Through for 1 HDMI, 1 USB-A and 1 USB-C, made of steel and aluminium etc all complete Approved Make: Logic, CPMG, Altenix
SITC of Video Conferencing PTZ Camera with IP-control, 1/2.8”high-quality CMOS sensor (2.07 Megapixel) , 12x optical zoom and 54° or more horizontal angle view, resolution of 1920 x 1080p at 60 fps, Output: 3G-SDI, HDMI, and IP (H.264/H.265) up to 1080p60. USB 2.0 up to 1080p30, VISCA, Pelco-D/P via RS232, RS485, Visca over IP, or IR, remote control included, Up to 255 presets with 0.1° accuracy, Dual H265, H264 and MJPEG compression at a bitrate of 64Kbit to 40Mbps, enabling Full HD video stream by ultra-low bandwidth over RTSP, RTMP, UDP and Multicast etc all complete Approved Make: QSC, Avonic, Vaddio, Sony
SITC of 4x1 4K 18Gbps HDMI Switcher with KVM, 4 HDMI Inputs, 1 HDMI outputs, Stereo audio de-embedding, 1 USB-B (v3.2) input for each HDMI input, 3 USB-A (v3.2) inputs for peripherals, Supports HDMI 2.0 with 18Gbps for resolutions up to 4K UltraHD 60Hz, TMDS and 5V auto switching function, Control via front panel and RS232, All standards of the HDMI v2.0 specification are supported, including HDCP 2.2, HDR10 and Dolby Vision etc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 8x8 4K 18Gbps HDMI Matrix with Scaler and Audio Matrix, 8 HDMI inputs, 8 HDMI outputs, Analog and digital audio de-embedding, integrated audio matrix, Supports 18Gbps for resolutions up to 4K UltraHD 60Hz, Supports resolutions up to UltraHD 4K 60Hz (4:4:4) incl. HDR, Downscaling (4K - 1080p) on 4 outputs, 2.5W power via HDMI for AOC, HDCP2.3 compliant, HDMI output supports up to 5V / 500mA for AOC cables, Controllable via front panel, IR, RS232 and TCP/IP etc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of Wireless AV platform allows simultaneous content sharing for up to four 1080p presenters, Wireless screen casting with iOS, Android, Mac, Chromebook, and Windows devices through native AirPlay, Google Cast, or Miracast protocols, utomatically adapts to incoming or disconnected source content, Supports YouTube Live streaming, Supports cloud-based digital signage platforms, Local storage available for playback of images and video etc all complete Approved Make: Atlona, Kramer, Extron, Crestron
SITC of Digital Conference System: Chairman Discussion Unit with 400 mm Gooseneck Microphone, built-in Digital Signal Processing, Unit with Priority and Next-in-Line Configuration, Priority button silences all delegate microphones and allows only the chairperson to speak, Next-in-line button gives the floor to the next speaker in a waiting list of speakers who requested to speak, User Button with feedback, High-quality integrated loudspeaker, minimum 4W or better, Audio quality: 16 bit digital or better, Frequency response: 25 Hz-15,000 Hz or better, 3.5 mm stereo jack socket for headphones output with volume adjustment, Concealed conference bus connections, 2 x RJ 45 ethernet port (IN/OUT - interchangeable), Loop through, daisy-chain cabling (non-proprietary), Unit with Bi color bar indicator, Compatible screw lock microphone connectivity, Gooseneck microphone: Unidirectional, Cardioid Polar Pattern, Back electret (condenser), Pressure gradient, Max SPL @ 1 kHz 110 dB SPL (1% THD+N), Signal to noise ratio > 67 dB(A) Certification: CE; BIS etc all complete Approved Make: Televic / Shure / Marconi Technologies
SITC of Digital Conference System: Delegate Discussion Unit with 400 mm Gooseneck Microphone, built-in Digital Signal Processing, Unit with Microphone On / Off Button, User Button with feedback, High-quality integrated loudspeaker, minimum 4W or better, Audio quality: 16 bit digital or better, Frequency response: 25 Hz-15,000 Hz or better, 3.5 mm stereo jack socket for headphones output with volume adjustment, Concealed conference bus connections, 2 x RJ 45 ethernet port (IN/OUT - interchangeable), Loop through, daisy-chain cabling (non-proprietary), Unit with Bi color bar indicator, Compatible screw lock microphone connectivity, Gooseneck microphone: Unidirectional, Cardioid Polar Pattern, Back electret (condenser), Pressure gradient, Max SPL @ 1 kHz 110 dB SPL (1% THD+N), Signal to noise ratio > 67 dB(A) Certification: CE; BIS etc all complete Approved Make: Televic / Shure / Marconi Technologies
SITC of 20 meter Conference Cable from same OEM etc all complete Approved Make: Televic / Shure / Marconi Technologies
SITC of Audio, Video and control (AV&C) Processor, 64 x 64 Networked Audio Channels (LAN / AES67), 8 On-board Flex channels individually configurable as Mic/Line Input with Phantom Power or Line Output, 8 GPIO, 8 AEC Processors with with 200 ms tail length, up to 32 x 32 Dante audio channels (8 x 8 included), USB AV bridging (8 x 8 audio + Network Camera Support), Full-featured Control Engine (with feature license), External USB audio device host, Up to 2x VoIP instances, Phantom power +48 VDC, 24 bit A/D-D/A converters, Sample rate 48 kHz, 2 RS232 Ports etc all complete Approved Make: QSC, Biamp, Symetrix
SITC of 7" High Definition Touch Screen Controller, Projective capacitive (PCAP) multi-touch, Power over Ethernet, 24-bit color display, Resolution 1280 x 800 Pixels, Brightness 400 Nits or more, Ambient Light Sensor, Proximity Detection, Ambient Light Sensor, PoE (Power over Ethernet) PoE Class 3 with Table mount etc all complete Approved Make: QSC, Biamp, Symetrix
SITC of 8-port Multi-Gigabit (2.5G) Ultra60 PoE++ Ethernet Unmanaged Switch, Provides 8 ports 1G/2.5G with 4 PoE+ ports and 4 Ultra60 PoE++ ports etc all complete Approved Make: Netgear, D Link, Cisco
SITC 6.5" Two Way Ceiling Speaker, 30 Watt Rated noise power, frequency range 65 Hz to 20 kHz, Broad-band sensitivity 89 dB SPL, Coverage angle (-6 dB) 110°, Maximum continuous SPL 104 dB, Maximum peak SPL 110 dB, Rated impedance 8 ohms, Transformer taps 70 V: 30, 15, 7.5, 3.7, 1.9 watts and 8-ohm bypass, 100V: 30, 15, 7.5, 3.8, watts and 8-ohm bypass, Listed UL1480, UL2043 etc all complete Approved Make: QSC, Tannoy, Martin Audio
SITC Energy Star Dual Channel Class D Power Amplifier, 60 watts per channel into 4Ω and 8Ω, bridged to supply 200 watts into 4Ω and 8Ω, and up to 250 watts into 70V or 100V loads, Signal to Noise (A weighted, 20 Hz-20 kHz) >100 dB, Frequency Response 20 Hz - 20 kHz, Input Impedance >10 kΩ (balanced), >10 kΩ (unbalanced), Switchable Highpass Filter 80 Hz when Bridged in 70V & 100V, UL, CE, ENERGY STAR, RoHS/WEEE compliant etc all complete Approved Make: QSC, Labgruppen, Martin Audio
SITC of 1 Meter SuperThin 4K Premium High Speed HDMI Cable, HDMI version 2.0, 18 Gbps for resolutions up to 4K UltraHD 60Hz,Gold plated precision contacts with Ultra-Lock-System tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 5 Meter 4K Premium High Speed HDMI AOC Fiber Optic Cable, HDMI version 2.0, 18 Gbps for resolutions up to 4K UltraHD 60Hz, Gold plated precision contacts, incl. HDR 10, HDR 12 and Dolby Vision, Supports ARC and eARC tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 10 Meter 4K Premium High Speed HDMI AOC Fiber Optic Cable, HDMI version 2.0, 18 Gbps for resolutions up to 4K UltraHD 60Hz, Gold plated precision contacts, incl. HDR 10, HDR 12 and Dolby Vision, Supports ARC and eARC tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 15 Meter 4K Premium High Speed HDMI AOC Fiber Optic Cable, HDMI version 2.0, 18 Gbps for resolutions up to 4K UltraHD 60Hz, Gold plated precision contacts, incl. HDR 10, HDR 12 and Dolby Vision, Supports ARC and eARC tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 5 Meter USB-A / USB-B AOC Fiber Optic Cable, USB 3.2 (Gen 2x1, not backward compatible with USB 2.0) 10Gbps data transmission, Gold plated precision contacts, USB-A male to USB-B male, full-metal housingWith EMI resistance, low attenuation, no external power supply required tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of 10 Meter USB-A / USB-B AOC Fiber Optic Cable, USB 3.2 (Gen 2x1, not backward compatible with USB 2.0) 10Gbps data transmission, Gold plated precision contacts, USB-A male to USB-B male, full-metal housingWith EMI resistance, low attenuation, no external power supply required tc all complete Approved Make: PureLink, Kramer, Extron, Crestron
SITC of Various Cables & Connectors etc all complete
SITC of 20U, Equipment Rack, with Front & Side doors, 4 No Fan Assembly, on Top of the Rack, 4 Caster wheels, 2 no Shelfs to mount the equipments which are not rack mounted, 8X2, 5/6 Amp. Power Distribution Unit, Cable Manager & Sufficient Rack hardwares etc all complete Approved Make: Valrack, Netrack, FSS
SITC of 24 AWG Microphone Cable, 24 AWG (25/0.10mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, polyester mylar taped, aluminium foil + spiral shielded (97%) with ATC copper, outer Jacketed with Matt finish High Flex Special PVC (as per actual) etc all complete Approved Make: Krystal, Belden, Falcon, Sommer
SITC of Speaker Cable: 2.5 Sqmm (80/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath (as per actual) etc all complete Approved Make: Krystal, Belden, Falcon, Sommer
FURNITURES AND WORKSTATIONS (The dimensions given are tentative and shall be finalized by referring the respective locations mentioned in the specifications from the attached tender drawings) Supply of high back chairs of the following dimensions and specifications in Conference rooms (50 seater capacity- 2 Nos) in Ground floor: CASTORS: TWIN CASTORS 50MM DIA COMPLYING TO ANSI / BIFMA X 5.1 - 2002 STANDARDS. THE TWIN WHEEL CASTORS SHALL BE INJECTION MOULDED NYLON BASE: THE BASE SHALL BE MADE OF INJECTION MOULDED NYLON MATERIAL (TESTED PRUDENTLY AND RIGOROUSLY AS PER ANSI/BIFMA X5.1-2011 GENERAL PURPOSE OFFICE CHAIR STANDARDS) AND FITTED WITH 5 NOS OF TWIN WHEEL CASTORS GAS LIFT: STANDARD GAS LIFT (120MM) GAS LIFT - CLASS 4 TESTED -ANSI BIFMA PERFORMANCE STANDARDS. THE PNEUMATIC HEIGHT ADJUSTMENT HAS AN ADJUSTMENT STROKE OF 95-100 CM AS PER THE SEAT HEIGHT CRITERIA. MECHANISAM: 360 DEGREE REVOLVING TYPE, SINGLE LOCKING SYNCHRO MECHANISM WITH ONE LEVER CONTROL FOR LOCKING AND SEAT HEIGHT ADJUSTMENT, WITH TILT TENSION ADJUSTMENT. ARMREST: ONE WAY HEIGHT ADJUSTABLE ARMREST. THE ARM TOP IS MADE OF SOFT MOULDED PU MATERIAL. BACKREST: THE BACK SHALL BE MADE OF TWO PIECE INJECTION MOULDED FRAME. THE INNER FRAME SHALL BE UPHOLSTERED WITH MESH FABRIC AND MOUNTED ON THE MAIN ASSEMBLY. LUMBER SUPPORT MADE UP OF INJECTION MOULDED IN BLACK PP, UPHOLSTERED WITH PU FOAM. SEAT: MADE UP OF 12MM THICK HOT PRESSED PLY WOOD AND PU MOULDED SEAT FOAM UPHOLSTERED WITH MICRO FABRIC FABRIC: 100% POLYSTER-340-350 GSM GRADE. ABRASION->50000 CYCLES FOAM: CUSHION WITH PRE MOULDED FOAM OF 50-55 DENSITY IN THE SHAPE OF PLYWOOD DENSITY: 52 KG/M3, HARDNESS-22-28 KGF HEADREST: Height Adjustable headrest with cushion Make: Featherlite (Astro), Wipro (Thats's it), Bosq-Jazz (101)
Supplying CONFERENCE TABLES of following dimensions and specifications in Conference rooms in Ground floor: CONFERENCE TABLE SIZE (4000 MM (L) X 1200 MM (D) X 750 MM (H) 1) Table top 25 mm thick pre laminated particle board with 2mm edge lipping finish, 2) Under structure made of 50 x 50 MS square leg with powder coated finish. 3) Crossbar made of square ms tube with powder coated finish. 4) Wire manager raceway frame for electrical and network 50 MM X 250 MM HT with powder coated metal facia shall be provided on the main span 5) 2 flip up shall be provided for electrical and network access Make: Featherlite/Wipro/Bosq/Benfit/Metafab
Furnishing Auditorium (192 seater capacity), with suitable chairs, with dimensions matching with that of tender drawings, in Ground floor
Fabrication, supply and installation of LINEAR WORKSTATIONS AND MOBILE PEDESTALS in SBC modules on first floor with the following specifications: Linear Sharing Workstations (Size:- as per tender drawings) • Table Top: 25 mm thick pre-laminated particle board in E1 grade finish with 2 mm thick PVC edge banding of REHAU make and 681Kg/M3 density with 0.68 N/mm2 Tensile strength, 475 rev abrasion resistance (min) with 6.25 mg/100g dry board formaldehyde content, grommet hole with cap should be provided on table top to access plug sockets below the table. • Support Legs: The tabletop shall be supported on 50 X 50 mm, MS Powder coated square legs with 16 gauge metal thickness. Crossbar should be made of 40 X 20 mm MS tube with powder coated finish (60-80 microns). • Privacy Screens: Sandwich glass screens with 8 MM thick laminated glass (300 mm Height) of approved colour supported on brackets duly powder coated. • Wire Management: Wire manager raceway frame for electrical & network of size 50 mm thick X 250 mm Height CRCA sheet with 16 gauge thickness with powder coated finish should be provided on main span below the table with separator for data and power cables. Necessary cutting has to be provided for placing the sockets (electrical/network) as per the directions of Technopark. The Wire entry box should be provided to each cluster of workstations and the size of wire entry should be 200 w x 50 d x 425 ht (mm) made of 16 gauge thick MS sheet.
SUPPLY OF CABIN TABLES WITH FOLLOWING SPECIFICATIONS for SBC modules in first floor SIZE (1200 MM (L) X 600 MM (D) X 750 MM (H) 1). Elegant design wotk desk with 25 mm top panel and legs 2). A lockable drawer with telescopic runners and drawer pull. 3). A shutter with hydraulic soft close hinges and handles. 4). 2 gromets for wire management. 5). Certified MFC fabrication (Engineered wood) 6). Premium grade hardwares and PVC edge lipping Make: Featherlite/Wipro/Bosq/Benfit/Metafab
Supply of medium back chairs of following dimensions and specifications for SBC modules in first floor: CASTORS: TWIN CASTORS 50MM DIA COMPLYING TO ANSI / BIFMA X 5.1 - 2002 STANDARDS. THE TWIN WHEEL CASTORS SHALL BE INJECTION MOULDED NYLON BASE: THE BASE SHALL BE MADE OF INJECTION MOULDED NYLON MATERIAL (TESTED PRUDENTLY AND RIGOROUSLY AS PER ANSI/BIFMA X5.1-2011 GENERAL PURPOSE OFFICE CHAIR STANDARDS) AND FITTED WITH 5 NOS OF TWIN WHEEL CASTORS GAS LIFT: STANDARD GAS LIFT (120MM) GAS LIFT - CLASS 4 TESTED -ANSI BIFMA PERFORMANCE STANDARDS. THE PNEUMATIC HEIGHT ADJUSTMENT HAS AN ADJUSTMENT STROKE OF 95-100 CM AS PER THE SEAT HEIGHT CRITERIA. MECHANISAM: 360 DEGREE REVOLVING TYPE, SINGLE LOCKING SYNCHRO MECHANISM WITH ONE LEVER CONTROL FOR LOCKING AND SEAT HEIGHT ADJUSTMENT, WITH TILT TENSION ADJUSTMENT. ARMREST: ONE WAY HEIGHT ADJUSTABLE ARMREST. THE ARM TOP IS MADE OF SOFT MOULDED PU MATERIAL. BACKREST: THE BACK SHALL BE MADE OF TWO PIECE INJECTION MOULDED FRAME. THE INNER FRAME SHALL BE UPHOLSTERED WITH MESH FABRIC AND MOUNTED ON THE MAIN ASSEMBLY. LUMBER SUPPORT MADE UP OF INJECTION MOULDED IN BLACK PP, UPHOLSTERED WITH PU FOAM. SEAT: MADE UP OF 12MM THICK HOT PRESSED PLY WOOD AND PU MOULDED SEAT FOAM UPHOLSTERED WITH MICRO FABRIC FABRIC: 100% POLYSTER-340-350 GSM GRADE. ABRASION->50000 CYCLES FOAM: CUSHION WITH PRE MOULDED FOAM OF 50-55 DENSITY IN THE SHAPE OF PLYWOOD DENSITY: 52 KG/M3, HARDNESS-22-28 KGF Make: Featherlite (Astro), Wipro (Breathe), Bosq (Jazz 201), Benfit (BJS 002), Metafab (Porus)
Supply of pantry chairs of following specifications for food court area on 9th floor: • SEAT & BACKREST: 16 GAUGE POLYPROPYLENE ALLOY • LEGS: 16 GAUGE METAL FRAME WITH POWDERCOATED (WOODEN) FINISH Model and colour shall be confirmed by Technopark.
Supply of dining tables of following specifications for food court area on 9th floor: • DINING TABLE: (SIZE: 120 CM X 80 CM) • TABLE TOP: 16MM MARINE BWP GRADE PLYWOOD WITH 0.8 MM ARCHID LAM MICA PASTED WITH D3 GUM LAMINATION WITH 2MM THICK EDGE BANDING. • TABLE BASE SIZE: 450MMX700MM, 6 MM POWDER COATED BASE PLATE SHALL BE PROVIDED. • PILLAR HEIGHT: 720MM • FRAME WEIGHT: 16.170 Kg • PILLAR: 75 MM DIA 16 GAUGE MS POWDER COATED PILLAR (2 Nos) SHALL BE PROVIDED TO CONNECT THE TABLE TOP AND BASE. • CONNECTOR SIZE: 250MMX250MM, 16 GAUGE MS POWDER COATED CONNECTOR (2 Nos) SHALL BE PROVIDED BELOW THE TABLE TOP.
Supply of dining tables of following specifications for food court area on 9th floor: • DINING TABLE: (SIZE: 90 CM X 90 CM) • TABLE TOP: 16MM MARINE BWP GRADE PLYWOOD WITH 0.8 MM ARCHID LAM MICA PASTED WITH D3 GUM LAMINATION WITH 2MM THICK EDGE BANDING. • TABLE BASE SIZE: 450MMX450MM, 6 MM POWDER COATED BASE PLATE SHALL BE PROVIDED. • PILLAR HEIGHT: 720MM • FRAME WEIGHT: 13.520 Kg • PILLAR: 75 MM DIA 16 GAUGE MS POWDER COATED PILLARS (1 Nos) SHALL BE PROVIDED TO CONNECT THE TABLE TOP AND BASE. • CONNECTOR SIZE: 250MMX250MM, 16 GAUGE MS POWDER COATED CONNECTOR SHALL BE PROVIDED BELOW THE TABLE TOP.
JATAN CONSTRUCTIONS PVT LTD (BID ID -2354271)
Bridge And Roof Co. (I) Ltd. (BID ID -2381377)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.31 MB
7_BOQ_Annexure_Electrical.pdf
Tender Documents • 1.04 MB
BOQ_1304211.xls
BOQ • 10.56 MB
8_BOQ_Annexure_MEP.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid