| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹28.0 L+₹5.1 L (22.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Nov 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
REPAIR AND MAINTENANCE OF FIRE DETECTION SYSTEM, EOT CRANE AND STABILIZER AT AFS BARODA
2024_MES_675479_2
8919/E8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
270 days
GE (AF) BARODA, DARJIPURA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹40,000
Yes
28 Nov 2024
19 Oct 2024
11 Nov 2024
19 Oct 2024
9 Nov 2024
26 Oct 2024
Amount
Comprehensive Qutarly maintence/servicing checking caliberation testing of existing fire alram panel, connected wiring system, detectors and devices of any type as per existing on site, Programming and configuration check installed in Makarpura and Harni air field/darjipura AF Stn Vadodara. The detail scope of work consists of the following :- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (vii) Testing of entire fire alarm system and rectification of fault complete to the entire satisfaction of engr-in-charge all as specified and directed . (viii) All Spares inclusive in the quoted rate excluding items here-in-after mentioned
Taking down unserviceable DCP type portable fire extinguiser 6 kg ISI marked from the existing locations along with existing arrangements, Supply and fixing new DCP 6 Kg fire extinguisher with clamp,nut and bolt etc for ABC class of fire in and including poper fixing in the installtions complete all as directed by Engineer-in-charge.
Taking down unserviceable DCP type portable fire extinguiser 4 kg ISI marked from the existing locations along with existing arrangements, Supply and fixing new DCP 4 Kg fire extinguisher with clamp,nut and bolt etc for ABC class of fire in and including poper fixing in the installtions complete all as directed by Engineer-in-charge. Make for Sl item No. 2 to 3 - Safety Plus/Ceasefire/Safex
M & L for SMPS for Fire Alarm panel complete checking all as specified and directed. Make : Honey bell or equivalent
M & L for Loop driver card for the morley for Fire Alarm panel complete checking all as specified and directed including taking down of existing. . Make : Honey bell or equivalent
M & L for Addressable smoke Detector for Fire alarm complete all as specified and directed including taking down of existing.
M &L fire alarm control panel Addresstable type including configuration and programming complete. Make honywell /morely
S&F in replacement of Addressable Dual tone electronic sounder / hooter enclosed in MS box with LED indication hooter complete all as specified and directed.
Supply and fixing in replacement of manual call point resettable type complete as directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Comprehensive maintenance (Consisting of normal repairs) preventing maint as follows Once in three months for 9 month of electrically operated travelling (EOT) Flame Proof cranes of capacity 5 Ton make: Rock well & Crane including at site complete all as specified and directed by Engineer -in- Charge Note: - (a). Replacement of the unserviceable spare parts shall be measured and paid sepreatly.
(i) Long Traverse (a). Cleaning of Gear box and oil level checking rectification of leakages if any. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Long Traverse wheel checking for any noise. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake (g). Checking of electric motor connections (h). To check the cut off at extreme end with limit switch. (i). Checking and greasing \ oiling of plumber block. (j). Long traverse. (ii) Cross Traverse (a). Cleaning of Gear box and oil level checking rectification of leakages if any. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Long Traverse wheel checking for any noise. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake (g). Checking of electric motor connections (h). To check the cut off at extreme end with limit switch. (i). Checking and greasing \ oiling of plumber block. (j). Cross traverse.
(iii) Hoist Motion (a). Gear box oil level check & rectification of leakages. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Checking for the main bearing of the rope drum including graesing. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake. (g). Checking of electric motor connections. (h). Checking wire rope & greasing. (i). Adjustment of rotory limit switch. (j). Baering graese \ oiling in bottom block \ hock. (iv). Electrical Network (a). Checking the contactor for overheating and flashing. (b). general checking of contacts and connections. (c). Cleaning of control panels. (d). Checking of connection AC Drive and othher drives for smooth functioning of the same. (v). Down shop lead (DSL) (a). Checking the alingment and rectification. (b). Cleaning of the moving \ slidding objects.
Comprehensive maintenance (Consisting of normal repairs) preventing maint as follws Once in three months of Hand operated travelling (HOT) Flame Proof cranes of capacity 5 Ton make: Rock well & Cranx including at site complete all as specified and directed by Engineer -in- Charge Note: - (a). Replacement of the unserviceable spare parts shall be measured and paid sepreatly.
(i) Long Traverse (a). Cleaning of Gear box and oil level checking rectification of leakages if any. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Long Traverse wheel checking for any noise. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake (h). To check the cut off at extreme end with limit switch. (i). Checking and greasing \ oiling of plumber block. (j). Long traverse. (ii) Cross Traverse (a). Cleaning of Gear box and oil level checking rectification of leakages if any. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Long Traverse wheel checking for any noise. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake (h). To check the cut off at extreme end with limit switch. (i). Checking and greasing \ oiling of plumber block. (j). Cross traverse.
(iii) Hoist Motion (a). Gear box oil level check & rectification of leakages. (b). Checking Assembly vibration. (c). Brake Adjustment. (d). Checking for the main bearing of the rope drum including graesing. (e). Geared couplings - grease checking and nut tightening. (f). Checking of hydraulic oil in thristor brake. (g). Checking of electric motor connections. (h). Checking wire rope & greasing. (i). Adjustment of rotory limit switch. (j). Baering graese \ oiling in bottom block \ hock. (iv). Electrical Network (a). Checking the contactor for overheating and flashing. (b). general checking of contacts and connections. (c). Cleaning of control panels. (d). Checking of connection AC Drive and othher drives for smooth functioning of the same. (v). Down shop lead (DSL) (a). Checking the alingment and rectification. (b). Cleaning of the moving \ slidding objects.
Attending Complaints and rectification of electronic, electrical and mechanical defects by authorized experience technician for flame proof EOT/HOT crane of capacity 5 Ton, Checking of uncerviciable electrical system and find out defect of control wiring in control panel (Hoist, Long Travel, Cross Travel) Control Switch Limit Switch Rectified the seme and make serviciable complete and testing thereafter complete all as specified and directed by engineer - in - charge. Note: - (a). The complaint shall be notified to the contactor by engineer - in - charge / JE E&M telephonically / personnaly / by SMS recorded in the register mentioned for the purpose. (b). Contactor shall make neccessary arrangement to attend the complaint. (c). Cost of any minor nature of repair / replacement of petty item such as nuts, bolts, washers, screws, piece of electrical cable upto 0.5 meter length etc, is deemed included in the unit rate quoted by the contractor. (d). Any other major item / repair required for the rectification shall be measured and paid seperately under respective item of the schedule. (e). Complaint number, date, location, date of rectification shall be entered in MB for payment purpose.
M&L for annual load testing electrically operated travelling(EOT) crane upto 25 mtrs span 0.5 TON and up to 6 TON capacity including requirment of load and transportation of load material and necessary equipments for testing & including preperation of old steel surfaces and appying one coat of synthetic paint complete all as specified and as directed.
- Ditto - all as per item No here in before but of hand operated ( HOT ) up to 10 mtrs span of capacity up to 2.5 Ton
Repair and making true alignment of crane track and track joint by means of welding, heating , cutting, grouting and fixing of new pressure plate of bolts including necessary plastering, repairing and leveling of crane track including grouting in PCC(1:2:4) concrete and required new rolled mild steel angle (Fe-410-W, grade E-250, quality-B)of size 40 x 40 x5 mm at edge of trench including testing for smooth functioning complete all as specified and directed.
Supply only triple spur gear chain pully block ( hand operative) capacity 2 Ton maximum hook 5 mtrs on from ground travel suitable for operation from floor including test certificate
Supply only push button switch for EOT crane with elements 6 Amps 415 volts 50 Hz
Supply only Geared rotary limit switch 3 phase 415 volt 50 Hz, 10 Amps No -22-1210-2 KV for EOT crane of any capacity suitable for any motion
Supply only TP contact, 3 phase, 20 Amps with coil
Supply only Carbon brush for clutch for micro movement of EOT crane
Supply only push button switch for EOT crane with elements 6 Amps 415 volts 50 Hz
Supply only Geared rotary limit switch 3 phase 415 volt 50 Hz, 10 Amps No -22-1210-2 KV for EOT crane of any capacity suitable for any motion
Supply only Electro hydraulic thrust break operated model 140321, drum dia 200mm, shoe width 70mm thurst 18 Kg strock 50mm 3 phase 400 / 400 volt, 50 cycle, 150 watt breaking torque 9 Kg maximam number of operation 360 per hour Make speed 'O' contral/stron/ sterling control or equivalent.
Comprehensive monthly maintence of 30 KVA/10KVA UPS system installed Makarpura. The detail scope of work consists of the following :- (i) Execute diagnostics and physical checks. (ii) Examine, clean, test, all equipment as required and repair parts as and when required. (iii) Measurement of UPS parameters like input/output voltage, frequency, current, frequency, room temperature etc. (iv) Battery Parameters like voltage, current and other relevant parameters. (v) Ensure dust free and controlled temperature conditions. (vi) The corrective maintenance may require multiple visits to site (vii) Check all Equipment LED LCD display board if any fault found to be rectified in the same cost. (viii) Checking of servicibility of MCB/MCCB if found unserviceagle to be replace without any extra cost. (ix) Checking of UPS fuse. if found us to be replace. (x) Keeping of servicibility of UPS is the responsibility of the contractor for the entire contract period. Note : Response time should be not more than 24 hours from the time of receipt of complaint on any working day between 9 AM to 6 PM.
Attending Complaints and rectification of electronic and electrical defects by authorized experience technician for UPS of capacity 10KVA/30KVA, Checking of uncerviciable electrical system and find out defect of control wiring in control panel and Rectified the seme and make serviciable complete and testing thereafter complete all as specified and directed by engineer - in - charge. Note: - (a). The complaint shall be notified to the contactor by engineer - in - charge / JE E&M telephonically / personnaly / by SMS recorded in the register mentioned for the purpose. (b). Contactor shall make neccessary arrangement to attend the complaint. (c). Cost of any minor nature of repair / replacement of petty item such as nuts, bolts, washers, screws, piece of electrical cable upto 0.5 meter length etc, is deemed included in the unit rate quoted by the contractor. (d). Any other major item / repair required for the rectification shall be measured and paid seperately under respective item of the schedule. (e). Complaint number, date, location, date of rectification shall be entered in MB for payment purpose.
M & L for VRLA(Valve regulated lead acid)/Sealed Lead acid maintenace free battery cap 12 V/65 Ah complete all as specified and directed.
Supply and fixng Bypass card suitable for 30 KVA DSP Based 3P -1Ph UPS
Supply and fixng Display card suitable for 15 KVA UPS
Supply and fixngTransformer card suitable for 15 KVA UPS
Supply and fixng Charging Card suitable for 15 KVA UPS
Supply and fixng DC driver Card suitable for 15 KVA UPS
M&L for carrying out following work through manufacturer's authorised service engineer of voltage stabilizer disconnecting of all electrical connections of stabilizer and check the auto/manual function of stabilizer, to be check the oil level, oil seals leakage if any, check all volt meters and amp meter working condition or not, Taking out top cover of stabilizer for replacing defective parts/items clean the dust by air blower, check the neutral and earthing connections properly or not, to be done properly, to be check the all nut bolts tightining. and refixing, the same in existing location, and re connect all the incoming/outgoing cables properly including testing and commissioning complete all as specified and as directed.of following capacities and located at various tech Accn
i) Opening of stabilizer at tech Accn workshop and taking out all defective / serviceable parts fixing of new parts after repair inplace of defective part, rewiring of defective conduit wiring etc and assembling complete all as specified & directed.
ii) Testing of stabilizer after repair on existing load to give desired & rated output
iii) M & L for preparation of old painted surface by hand scrap and applying one coat of primer and two coats of synthetic enamel paint by spray painting.
Note : - All defective parts including cable & oil replaced will be measured & paid separately under relevent item of schedule as supply only. However cost of labour for fixing of new part deemed to be included in unit rate of sl item No.1 above.
(a). 20 KVA to 30 KVA capacity
(b). 50 KVA-60KVA capacity
(c). 75 KVA capacity
(d). 100 KVA capacity
(e). 150 KVA capacity
(f) 250 KVA Capacity
Supply only electronic servo card of suitable size as per ground including all accessories required for fitting complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON).
Supply only under mentioned spares for voltage stabilizer of different capacitites:-
(a). Sychronising motor low speed instant start, stop high torque input voltage 250V single phase 50HZ 60 RPM type 53-102114, 0 to 15 Amp
(b). Control transformer 24 volt DC
(d). Toggle switch 10 Amps
(e). Indication lamp with bulb
(f). Limit switch with aluminium housing
(g). Reset switch 10Amps 230 V AC
(j). Aluminium brush assembly for 3 x 16.6 / 25 KVA stabilizer
(k). Terminal strip for stabilizer
(l). Insulator for dimmer
(n) MCCB TPN 63 Amp 16 KA With magnetic and thermal release
(m) MCCB TPN 100 Amp 25 KA With magnetic and thermal release
(o) MCCB TPN 160 Amp 25 KA With magnetic and thermal release
(p) MCCB TPN 200 Amp 35 KA With magnetic and thermal release
(q) MCCB TPN 250 Amp 35 KA With magnetic and thermal release
(r) MCCB TPN 315 Amp 35 KA With magnetic and thermal release
(r) MCCB TPN 400 Amp 35 KA With magnetic and thermal release
Material & Labour for refilling/topping up/replacement of stabilizer Oil with new dehydrated stabilizer Oil. open lid cover of stabilizer including changing of gasket set if required complete and re-fixing of top lid cover without any damage to stabilizer suitable for working voltage 440 volts grade including necessary dehydration to achieve dielectric strength min 40 KV. including internal/external connection and testing on load of stabilizer complete all as specified and as directed. (Make:- HPCL(SEETAL)/ HP (SEETAL)/ SERVO/GULF/ CASTROL).
Supply and fixing coloured electric shock and its management chart of size 70x100 cm in english and hindi both language and it should be water proof,tear proof, dust proof and double side laminated with 30 micron thick plastic film suitable for fix on wall of machine room including all connected accessories and neccessory arrangement for fixing complete all as specified and as directed.
Supply and fixing coloured fire safety chart of size 70x100 cm in english and hindi both language and it should be water proof,tear proof, dust proof and double side laminated with 30 micron thick plastic film suitable for fix on wall of machine room including all connected accessories and neccessory arrangement for fixing complete all as specified and as directed.
Supply and fixing coloured lift DO and Don't chart of suitable size in english and hindi both language and it should be water proof,tear proof, dust proof and double side laminated with 30 micron thick plastic film suitable for fix on wall including all connected accessories and neccessory arrangement for fixing complete all as specified and as directed.
Supply and fixing in repair of CO2 type fire extinguisher at stored pressure of capacity of 0.50 Kg complete all as specified and as directed
Refilling of CO2 in existing fire extigusher of capacity 2.5 ltr-5 ltr and testing and sealing complete
M & L for chemical Earthing complete in repairs with copper earth plate 60 cm x 60 cm x3.15 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including copper earth strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.
Earthing complete in repairs with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.
Mohshin Refrigeration & Electrical Services (BID ID -3153336)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .