Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.7 L+₹9.3 L (36.6%)Rejected-Finance 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹36.1 L+₹10.7 L (42.1%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | L3 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | Gayatri Associates L2 | City Light L3 | Rasam Engg Co. L1 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for preparation of existing old painted surface of any description such as Panels any height and painted with Ist quality two coat of synthetic enamel paint with one coats of primer (superior quality) and in blue color all around the panels. (Make of Paint : Asian, Berger or equivalent.) | 25 | Each | 2,000 ₹50,000 | 2,500 ₹62,500 | 1,200 ₹30,000 Lowest |
| 2.00 | M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 100A 16 KA 4 pole, outdoor type, double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .
Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed. | 2 | Each | 50,000 ₹1,00,000 | 55,000 ₹1,10,000 | 40,000 ₹80,000 Lowest |
| 3.00 | Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed. | 10 | Each Job | 500 ₹5,000 | 400 ₹4,000 Lowest | 500 ₹5,000 |
| 4.00 | M & L for preparation of existing old painted surface of any description such as LT steel tubular electric pole/struts of any height and painted completed including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint as directed. | 10 | Each | 500 ₹5,000 Lowest | 600 ₹6,000 | 600 ₹6,000 |
| 5.00 | Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMFAPFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only) | 5 | Each Job | 5,000 ₹25,000 | 4,800 ₹24,000 | 4,500 ₹22,500 Lowest |
| 6.00 | Supply only in replacement of APFC microprocessor based relay up 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make-L&T/EPCOS/Siemens | 4 | Each | 36,000 ₹1,44,000 | 30,000 ₹1,20,000 | 8,000 ₹32,000 Lowest |
| 7.00 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge. | 4 | Each | 9,000 ₹36,000 | 12,000 ₹48,000 | 4,500 ₹18,000 Lowest |
| 8.00 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge. | 5 | Each | 12,000 ₹60,000 | 15,000 ₹75,000 | 6,000 ₹30,000 Lowest |
| 9.00 | Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | 5,000 ₹25,000 Lowest | 7,000 ₹35,000 | 7,500 ₹37,500 |
| 10.00 | Supply only of capacitor duty contactor 3 phase suitable upto 5 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | 10,000 ₹50,000 | 12,000 ₹60,000 | 2,500 ₹12,500 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Sept 2025, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2025_MES_725158_1
8880
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE ARMY BARODA
₹70,000
Yes
14 Oct 2025
8 Aug 2025
6 Sept 2025
8 Aug 2025
5 Sept 2025
24 Aug 2025
8 Aug 2025 - 16 Aug 2025
Amount
M&L for preparation of existing old painted surface of any description such as Panels any height and painted with Ist quality two coat of synthetic enamel paint with one coats of primer (superior quality) and in blue color all around the panels. (Make of Paint : Asian, Berger or equivalent.)
M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 100A 16 KA 4 pole, outdoor type, double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge . Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.
Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed.
M & L for preparation of existing old painted surface of any description such as LT steel tubular electric pole/struts of any height and painted completed including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint as directed.
Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMFAPFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
Supply only in replacement of APFC microprocessor based relay up 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make-L&T/EPCOS/Siemens
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T
Supply only of capacitor duty contactor 3 phase suitable upto 5 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 Amps, curve 'c' ,10 KA complete all as specified and directed by Enginner-in-Charge.
Supply & fixing in replacement of MCB SPN 16 to 32 Amps, ,curve 'c' 10 KA complete all as specified and directed by Enginner-in-Charge.
Supply & fixing in replacement of MCB 40 to 100 Amps, TPN curve 'c' 10 KA complete all as specified and directed by Enginner-in-Charge.
Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
S&F following MCCBs thermal and magnetic adjustable of capacities , mentioned against each as suitable to be housed in existing space including link separator of existing including taking down old UNSV or as specified in list of make in PS.
MCCB 63 Amp, 4 Pole 415 Volt ,16 KA, Thermally and Magnetic Adjustable
MCCB 100 Amp, 4 Pole 415 Volt ,25 KA, Thermally and Magnetic Adjustable
MCCB 125 Amp, 4 Pole 415 Volt ,25 KA, Thermally and Magnetic Adjustable
MCCB 160 Amp, 4 Pole 415 Volt ,25KA, Thermally and Magnetic Adjustable
MCCB 200 Amp, 4 Pole 415 Volt ,25KA, Thermally and Magnetic Adjustable
MCCB 250 Amp, 4 Pole 415 Volt ,25 KA, Thermally and Magnetic Adjustable
MCCB 320 Amp, 4 Pole 415 Volt ,36 KA, Thermally and Magnetic Adjustable
MCCB 400 Amp, 4 Pole 415 Volt ,36 KA, Thermally and Magnetic Adjustable
S & F in repair of on load changer switch in sheet steel enclosure four pole, 415volt, front handle operated of capacity 400 Amp complete, change over switch fixed in panels or on walls as per site requirement including taking down old UNSV change over switch any make and type all as specified and directed by EIC Make- Legrand / ABB / Havells or as specified in list of make in PS.
M & L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 5 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete including taking down old U/S earthing. Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included in the quoted rate. (ii )On testing after completion if the desired earth resistance less than 2 ohm is not obtained the earthing will be redone at no extra cost.
S & F in repair new danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down all as specified and directed.
Supply and fix in repairs following Aluminium Lugs , of suitable size all as specified and directed by EIC.
Disconnecting existing LT Panel including aking out cable cable ends from panels and inserting new lugs after cutting opening of fresh cable end complete & raising the height of LT panel supporting angle iron of any size by 3 feet height from ground level by providing angle iron and including civil work (like PCC,excavation and brick work etc) for existing maching size of iron connected complete duly welding work painting of LT panel (inner portion and outer portion) including necessary fabrication should be made and complete all as specified and directed by Engineer-in- Charge. Note:- (i) All items reqd for raising the panel viz angle iron and welding work etc is deemed to be incuded in the rate quoted.
Excavation in trenches not exc 1.5 m wide & not exc 1.5 m in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.
M & L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :-
10 sq mm 2 core
16 sq mm 4 core
25 sq mm 3.5 core
35 Sq mm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core
95 sqmm 3.5 core.
120 Sqmm 3.5 core.
M&Lfor replacementof Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by EIC.
25 to 35 Sqmm
120 to 150 Sqmm
Supply and Laying including jointing and testing electric under ground LT cable PVC/XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches , ducts, pipe on walls, poles of following sizes
10 sq mm 2 core
16 sq mm 4 core
25 sq mm 3.5 core
35 Sq mm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core
95 sqmm 3.5 core.
120 Sqmm 3.5 core.
M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes :-
40 mm dia bore
50 mm dia bore
80 mm dia bore
Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 25 to 120 Sqmm.
Detecting of fault of LT UG cable (any place any length any type /size) including detecting exact location of cable fault and remove of cable for rectification and relaying the cable. Note: If fault not located no payment shall be made to contractor.
Laying of LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor in tranches/ducts/pipe, on wall, poles of following size retrived from item No 30.01 to 30.08
10 Sq mm 2 core
16 Sq mm 4 core
25 Sq mm 3.5 core
35 Sq mm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
Gayatri Associates (BID ID -3408453)
City Light (BID ID -3409533)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .