Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹65.1 Cr
EMD Value
₹1.3 Cr
Closing Date
15 Dec 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Yes (up to 4 members)
Yes (up to 4 members)
Two Packet System
EPC [ Single Stage ]
No
Not Applicable
Lowest to Highest
180 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
Please refer RFP for details
Please refer RFP for details
8 conditions · 3 needing a document upload
Please refer RFP for details
Please refer RFP for details
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Survey, design, supply, installation, testing and commissioning of trackside KAVACH equipment at stations/LC Gates locations including erection of towers and associated works required for KAVACH:(a) Kota - Chittorgarh section and Gurla "N" to Gurla "W" Section (148 Rkm) (b) Ramganjmandi - Biyavra Rajgarh section (165 Rkm) of Kota division of West Central Railway. This also includes supply, trenching, duct laying, blowing, splicing, termination, etc. of 4x48 and 2x24 fiber OFC with route diversity wherever required.
Kota-SnT-GSU-EPC-2026-03~WCR
Kota-SnT-GSU-EPC-2026-03
Open
Works - General
700 Days
Kota, Rajasthan
₹0
₹1.3 Cr
15 Oct 2026
15 Oct 2026
1 Dec 2026
31 items across 1 schedule · ₹50,85,601.2 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Alteration works in KAVACH/ Shifting of KAVACH at new location including all necessary works e.g. design, drawing, installation, wiring, testing (FAT & SAT), refixing/reprograming of tags, commissioning etc. except addition of hardware of new RIU, new RFID tag, new Stn/LC/IBH KAVACH, new relay, relay rack, new tower which will be either provided by Railway or paid to the firm with unit rate. Any alterations beyond 25% bits to be paid as per the following rates.a) Alterations in small station/ IBS/ABS (up to 4 lines) | Station | 3.00 | 5,00,000 | 15,00,000 |
| 2 | Alteration works in KAVACH includes all necessary works for e.g. design, drawing, installation, wiring, tesing (FAT & SAT) , commissioning etc. except addition of hardware of new RIU, new RFID tag, new Stn/LC/IBH KAVACH, new tower which will be either provided by Railway or paird to the firm with unit rate.Any alterations beyond 25% bits to be paid as per the following rates. (b) Alterations in big station/ IBS/ABS ( above 4 lines) | Station | 1.00 | 10,00,000 | 10,00,000 |
| 3 | Supply of 24 Fibre Armoured Optical Fibre Cable as per RDSO specification No.IRS:TC:55/2006 Rev-1 (Amdt. 3) or latest. | Kilometre | 2.00 | 56,103.1 | 1,12,206.2 |
| 4 | Supply of HDPE telecom duct with outer diameter of 40mm and inner diameter of 33mm permanently lubricated as per RDSO Specs: RDSO/SPN/TC/45/2006 revision 1.0 or latest. HDPE pipe shall be supplied along with 4mm dia polypropylene rope of approved quality inside wherever required. The length of HDPE telecom duct shold be 1km. end plugs to be provided along with drum (free of cost) (2 No. per km) | Kilometre | 2.00 | 45,955.1 | 91,910.2 |
| 5 | Supply of PVC insulated Armoured unscreened underground Railway Signalling cable of Size12 Core X 1.5 Sqmm confirming to RDSO Specificatin No.IRS:S-63/2014(Rev.4.0) | Kilometre | 4.00 | 2,47,442.46 | 9,89,769.84 |
| 6 | Supply of Underground railway jelly filled 6 Quad cable with spec no. IRTS 30-2005 Ver 1. with amen. 4 or latest of size dia 0.9mm in drums of 1 km | Kilometre | 2.00 | 2,84,974.72 | 5,69,949.44 |
| 7 | Supply of 4 conductor disconnect terminal block with test & measurement facility, with screw less, spring cage clamp connections suitable for 0.08 to 2.5 Sq.mm conductor with current capacity of 16 Amps as per RDSO Spcn. No. RDSO/SPN/189/2004 Ver. 3.0 or latest. | Numbers | 400.00 | 81.03 | 32,412 |
| 8 | Supply of End plate compatible to above screwless terminals. The end plates shall be of different colour than that of disconnect terminal blocks. | Numbers | 40.00 | 15.59 | 623.6 |
| 9 | Supply of Din rail of dimension 35mm x 7.5mm, 1 mm thickness, 1Mtr length, slotted compatible to above terminals of WAGO or PHOENIX make. | Numbers | 20.00 | 122.06 | 2,441.2 |
| 10 | Supply of End Stop 10mm for above Din 35 Rail of WAGO or PHOENIX make | Kilometre | 40.00 | 12.67 | 506.8 |
| 11 | Fixing of ARA/4 Way Wago/Phoenix/ terminals, and fuse blocks with provision of holes in Hylum Sheet and fixing by galvanised nuts and bolts in location boxes and elsewhere. This includes provision of two adiitional holes on the Hylum Sheet on either side of cable conductor entry. The work shall be done as per the instructions of Railway Engineer at site. | Numbers | 400.00 | 15.9 | 6,360 |
| 12 | Cable termination on ARA/disconnecting terminals, including fixing terminals, fuse blocks, 8 way terminal blocks in the apparatus case. This includes all associated works of pulling out the cable from underground, dressing of cable, making wire tree etc. This includes soldering of armour tree/ring of cables and and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per the location plans and instructions of Railway Engineer at site. | Per Conductor | 400.00 | 16.46 | 6,584 |
| 13 | Excavation of trench to a depth of 1200mm and width of 300m at bottom in all types of soil(Normal soil/soft soil/sandy soil except in h a r d morum / rocky soils /bridges/ level crossings/ track crossings/ coil pits, ) as per RDSO Sketch no SDO/CABLE LAYING /003 including marking of cable alignment, clearing of jungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished Item of work as directed by supervisor in- charge | Kilometre | 0.50 | 81,796.19 | 40,898.1 |
| 14 | Excavation of trench as per cable route plan to a depth of 1 meter and width of 300m at the bottom along main line in hard/morum soil. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahababad stone/ bricks, clearing of routes, bushes etc and refilling of trenches by excavated soil and ramming after laying of the required quantity of cables as per instruction of Railway Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer incharge before commencement of the cable laying process and only then shall be proportionate payment be made to the contractor. | Route Kilo Meter (RKM) | 0.50 | 1,18,910.13 | 59,455.07 |
| 15 | Laying of HDPE/GI/DWC/RCC/Half RCC pipe as per approved cable route plan, in the excavated trench taking due care while transporting and laying th same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done. | Kilometre | 2.00 | 11,249.55 | 22,499.1 |
| 16 | Blowing and drawing of optic fiber cable through laid HDPE/DWC duct in protective works already provided in the excavated trench as per approved cable route Plan, taking due care while transporting and sealing both the ends after laying. | Kilometre | 2.00 | 25,906.63 | 51,813.26 |
| 17 | Supply of 24-fiber armored optic fiber straight joint enclosure (SJC) complete with all accessories as per RDSO/SPN/TC/68/2014 (Rev.1.0) with latest amendments. Inspection Authority: Consignee | Numbers | 12.00 | 2,788.77 | 33,465.24 |
| 18 | Supply and installation of OFC main hole of size 1mtr.dia and 600mm deep ferro cement joint box for OFC Joints.The main hole shall have a thickness of 50mm . and shall be as per Drawing.No. Dy.CSTE/GSU/KOTA/TYPICAL DRG.OFC/02 & 01 | Numbers | 12.00 | 7,254.79 | 87,057.48 |
| 19 | Laying of all types of signalling signal/telecom/power cables of various cores/sizes excavated trenches. The work shall be done by extant practice followed on WCR | Kilometre | 6.00 | 8,795.24 | 52,771.44 |
| 20 | Excavation and Casting of Apparatus Case Foundation with mixture of Cement:Sand:Stone aggregate/Chip in 1:3:6 ratio and plastering with mixture of Cement:Sand in 1:4 ratio, with contractors own Metal Sheet ferma of the size mentioned in the drawing, cement, anchor bolts, with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site. All nuts, bolts and washers etc. should be galvanised iron. (i) Single Case as per Drg. No. Dy.CSTE/C/Kota/2 | Numbers | 6.00 | 11,824.68 | 70,948.08 |
| 21 | Excavation and Casting of Apparatus Case Foundation with mixture of Cement:Sand:Stone aggregate/Chip in 1:3:6 ratio and plastering with mixture of Cement:Sand in 1:4 ratio, with contractors own Metal Sheet ferma of the size mentioned in the drawing, cement, anchor bolts, with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site. All nuts, bolts and washers etc. should be galvanised iron. (i) Half Case as per Drg. No. Dy.CSTE/C/Kota/3 | Numbers | 6.00 | 11,396.98 | 68,381.88 |
| 22 | Erection of Apparatus cases. This includes filling of Location Foundations with the seived sand being used for making the foundation of location boxes and plastering on top of the sand. All nuts, bolts and washers etc. should be galvanised iron. (i) Single Case | Numbers | 6.00 | 1,240.69 | 7,444.14 |
| 23 | Erection of Apparatus cases. This includes filling of Location Foundations with the seived sand being used for making the foundation of location boxes and plastering on top of the sand. All nuts, bolts and washers etc. should be galvanised iron. (i) Half Case | Numbers | 6.00 | 948.76 | 5,692.56 |
| 24 | Supply, fabrication and fixing of Phenolic Laminated Sheet Board in Location Box by providing all fixtures, double ended insulators (06 Nos.), PVC coated string rods at the back side for cable support with contractor's own material. The work shall be done as per Drg. No. SK 783-1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be of 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of the Phenolic Laminated Sheet for Full Case terminal board should be 800mm x 950mm and for half case it should be 800mm x 450mm. In case board size is in variation with the size mentioned as per location details, then proportionate payment on area basis shall be made. This also include, the work to be done in existing Location Boxes (if required) as per instructions of Railway Site Engineer. (i) Single Case | Numbers | 6.00 | 4,877.16 | 29,262.96 |
| 25 | Supply, fabrication and fixing of Phenolic Laminated Sheet Board in Location Box by providing all fixtures, double ended insulators (06 Nos.), PVC coated string rods at the back side for cable support with contractor's own material. The work shall be done as per Drg. No. SK 783-1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be of 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of the Phenolic Laminated Sheet for Full Case terminal board should be 800mm x 950mm and for half case it should be 800mm x 450mm. In case board size is in variation with the size mentioned as per location details, then proportionate payment on area basis shall be made. This also include, the work to be done in existing Location Boxes (if required) as per instructions of Railway Site Engineer. (i) Half Case | Numbers | 6.00 | 2,999.11 | 17,994.66 |
| 26 | Supply, fabrication and fixing of Phenolic Laminated Sheet for Shelf of equipments/batteries with contractor's own fixing material, angle frames, additional in- between supporting angle for the Shelf, etc. The work shall be done as per Drg. No. SK 783- 1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of Shelf for Single Case Apparatus/Location Box shall be 500mm x 950mm and for Half Case Location Box it shall be 500mm x 450mm. In case board size is in variation with the size mentioned as per Location details, then proportionate payment on area basis shall be made. Galvanised nut & bolts to be used for fixing of Phenolic Laminated Sheets. (i) Single Case | Numbers | 6.00 | 3,105.23 | 18,631.38 |
| 27 | Supply, fabrication and fixing of Phenolic Laminated Sheet for Shelf of equipments/batteries with contractor's own fixing material, angle frames, additional in- between supporting angle for the Shelf, etc. The work shall be done as per Drg. No. SK 783- 1/2 with latest alterations & as per instructions of Railway Engineer at site. The Phenolic Laminated Sheets should be 10mm thick, grade P3 as per specification No. IS: 2036 of 1995 or latest. The size of Shelf for Single Case Apparatus/Location Box shall be 500mm x 950mm and for Half Case Location Box it shall be 500mm x 450mm. In case board size is in variation with the size mentioned as per Location details, then proportionate payment on area basis shall be made. Galvanised nut & bolts to be used for fixing of Phenolic Laminated Sheets. (i) Half Case | Numbers | 6.00 | 1,934.94 | 11,609.64 |
| 28 | Installation of Equipments (Relays, Resistance, chargers, Choke, batteries, LV box, KLCR, PPTC fuses & track feed charger alarm unit, etc. as applicable) with contractor's own wiring material, MS frame, copper lugs etc. & wiring of the same in Apparatus Cases as per Location Diagrams, paralleling of spare contacts of Metal to Carbon Relays and wiring of potential free contact of track feed charger and testing of track circuits as per instruction of Railway's Site Incharge and standard practice. This also includes supply of Multi-strand Flexible Single Core Copper Wire 2.5 sq.mm (50/0.25) except for relay wiring which will be done with 16/0.2 mm flexible multi-strand wire conforming to IS: 694:1990 with suitable lugs. All wires to be duly manufactured by RDSO approved firms (16/0.2 mm flexible multi-strand wire inspected by RDSO).Note: PPTC fuses shall be provided as per fixing arrangement of PPTC as advised by HQ's policy guideline issued vide letter no. WCR/N-HQ/110/Signal Policy/Sig-32 Pt-VII, dtd. 07.11.2013 i.e. PPTC fuse are to be connected with crimped ring type lugs and crimped area is also to be filled with solder. PPTC lead to be provided with ferrules for volt & current rating of PPTC. (i)Single Case | Numbers | 6.00 | 2,083.19 | 12,499.14 |
| 29 | Installation of Equipments (Relays, Resistance, chargers, Choke, batteries, LV box, KLCR, PPTC fuses & track feed charger alarm unit, etc. as applicable) with contractor's own wiring material, MS frame, copper lugs etc. & wiring of the same in Apparatus Cases as per Location Diagrams, paralleling of spare contacts of Metal to Carbon Relays and wiring of potential free contact of track feed charger and testing of track circuits as per instruction of Railway's Site Incharge and standard practice. This also includes supply of Multi-strand Flexible Single Core Copper Wire 2.5 sq.mm (50/0.25) except for relay wiring which will be done with 16/0.2 mm flexible multi-strand wire conforming to IS: 694:1990 with suitable lugs. All wires to be duly manufactured by RDSO approved firms (16/0.2 mm flexible multi-strand wire inspected by RDSO).Note: PPTC fuses shall be provided as per fixing arrangement of PPTC as advised by HQ's policy guideline issued vide letter no. WCR/N-HQ/110/Signal Policy/Sig-32 Pt-VII, dtd. 07.11.2013 i.e. PPTC fuse are to be connected with crimped ring type lugs and crimped area is also to be filled with solder. PPTC lead to be provided with ferrules for volt & current rating of PPTC. (i) Half Case | Numbers | 6.00 | 1,449.44 | 8,696.64 |
| 30 | Supply & installation of Thermo shrinkable jointing kit as per Spec. No. IRS TC. 77/2010(Rev 2) for all types joints suitable for 6 Quad Jelly filled UG cable. | Numbers | 25.00 | 4,733.03 | 1,18,325.75 |
| 31 | Splicing/ termination of 12 Fibre OFC (Per 12 fiber) | Numbers | 30.00 | 1,846.38 | 55,391.4 |
| Schedule total | ₹50,85,601.2 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Kota-COROFCCRP_compressed.pdf
ATTACHMENT
CRP1GQLTHEA6QUADCABLE.pdf
ATTACHMENT
CRP2THEABUNDI6QUADCABLE_compressed.pdf
ATTACHMENT
CRP3BUNDISNAR6QUADCABLE_compressed.pdf
ATTACHMENT
CRP4SNARJNRI6QUADCABLE_compressed.pdf
ATTACHMENT
CRP5JNRIURML6QUADCABLE.pdf
ATTACHMENT
CRP6URMLSMPA6QUADCABLE.pdf
ATTACHMENT
CRP7SMPAMLGH6QUADCABLE_compressed.pdf
ATTACHMENT
CRP8MLGHBNDI6QUADCABLE.pdf
ATTACHMENT
CRP9BNDIPSLI6QUADCABLE_compressed.pdf
ATTACHMENT
CRP10PSLIBSSL6QUADCABLE_compressed.pdf
ATTACHMENT
SIPs1BARUNDANI.pdf
ATTACHMENT
SIPs2BASSIBERISAL.pdf
ATTACHMENT
SIPs3BUNDIcompressed_1.pdf
ATTACHMENT
SIPs4JALINDRI.pdf
ATTACHMENT
SIPs5MANDALGARHcompressed.pdf
ATTACHMENT
SIPs6PARSOLI.pdf
ATTACHMENT
SIPs7SHYAMPURA.pdf
ATTACHMENT
SIPs8SRINAGAR.pdf
ATTACHMENT
SIPs9THALERACompressed.pdf
ATTACHMENT
SIPs10UPARMAL.pdf
ATTACHMENT
STLT1BARUNJDANIrotatedcompressed.pdf
ATTACHMENT
STLT2BSSL.pdf
ATTACHMENT
STLT3BUNDIcompressed.pdf
ATTACHMENT
STLT4JALINDRI.pdf
ATTACHMENT
STLT5MANDALGARHcompressed.pdf
ATTACHMENT
STLT6PARSOLIrotated.pdf
ATTACHMENT
STLT7SHYAMPURA.pdf
ATTACHMENT
STLT8SRINAGAR.pdf
ATTACHMENT
STLT9THALERA.pdf
ATTACHMENT
STLT10UPARMAL.pdf
ATTACHMENT
RFPofEPC-KAVACH-Kota_COR_RMA-BRRG15_10_26.pdf
ATTACHMENT
EPCdocumentEPC-KAVACH-15-10-26.pdf
ATTACHMENT
Feasibility Report of EPC document
ATTACHMENT
SIPs11AKLA.pdf
ATTACHMENT
SIPs12ghatoli.pdf
ATTACHMENT
SIPs13JhalaraPatan.pdf
ATTACHMENT
SIPs14JHALAWAR-CTIY-SIPNo-5077F.pdf
ATTACHMENT
SIPs15JULMI_1.pdf
ATTACHMENT
11AKLASTLT.pdf
ATTACHMENT
12GHATOLICOMPLETIONSTLT.pdf
ATTACHMENT
SIPs17_NAYAGAON_compressed_6MB.pdf
ATTACHMENT
SIPs18_RAJGARH_CITY_SIP.pdf
ATTACHMENT
SIPs19JAKA.pdf
ATTACHMENT
1RMA-JLF6QUADOFCCABLE.pdf
ATTACHMENT
2JLF-JLWC6QUADOFCCBLE_compressed.pdf
ATTACHMENT
3JLWC-JAPN6QUADOFCCABLE.pdf
ATTACHMENT
4JAPN-JAKA6QUADOFCCABLE.pdf
ATTACHMENT
5JAKA-AKLERA6QUADOFCCABLE.pdf
ATTACHMENT
6 AKLERA GHATOLI 6 QUAD OFC CABLE
ATTACHMENT
13_JAKA_STLT_0_compressed.pdf
ATTACHMENT
14_JAPN_STLT_0_compressed.pdf
ATTACHMENT
15_JHALAWAR_CITY-STLT_0_compressed.pdf
ATTACHMENT
16_KHILCHIPUR_STLT_COMPLETION_compressed.pdf
ATTACHMENT
17 NAYAGAON UPDATED STLT
ATTACHMENT
18_RAJGARH_CITY-STLT_compressed.pdf
ATTACHMENT
19_ST_of_JLF_compressed.pdf
ATTACHMENT
SIPs16KHILCHIPUR_compressed.pdf
ATTACHMENT
GuidelinesonSignallingCableLayingpart2.pdf
ATTACHMENT
Tower40MLatticeTowerGAD.pdf
ATTACHMENT
Tower40MLatticeTowerdrawing.pdf
ATTACHMENT
WTTowerSPIRE40MFOUNDATIONDRAWINGREPORT.pdf
ATTACHMENT
NWTTowerSPIRE40MFOUNDATIONDRAWINGREPORT.pdf
ATTACHMENT
GuidelinesonSignallingCableLayingpart1.pdf
ATTACHMENT
FeasibilityReportofEPC-KAVACH-Kota_CORRMA_BRRG15-10-2026.pdf
ATTACHMENT
7-GHATOLI-NAYAGAONROUTEPLAN6QUADOFCCABLE.pdf
ATTACHMENT
6_AKLERA-_GHATOLI_6_QUAD_OFC__CABLE_compressed.pdf
ATTACHMENT
17_NAYAGAON_UPDATED_STLT_01-03-2024_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .