Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.7 LAccepted-AOC 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹38.7 L+₹1.7 L (4.69%)Rejected-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹39.5 L+₹2.5 L (6.72%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹47.5 L+₹10.6 L (28.5%)Rejected-Finance 65 6 518 B 1 HIMACHAL NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹48.2 L+₹11.3 L (30.4%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹50.0 L
EMD Value
₹99,940
Closing Date
23 Apr 2025, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE)
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
PROVISION OF BUILDING SECURITY LIGHT AT NAUSENA BAUGH ,PROVISION OF SPLIT ACS AT VARIOUS UINTS AND SPECIAL REPAIR TO AUTOMATIC FIRE DETECTION SYSTEM AT BLO COMPLEX ,VISAKHAPATNAM
2025_MES_702683_1
C/8454/24-25/E8 / Token 103 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹99,940
16 Jul 2025
26 Mar 2025
30 Apr 2025
26 Mar 2025
23 Apr 2025
9 Apr 2025
Amount
M & L for Sub main wiring with 4 runs of Single core 10.0 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10.0 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :-Four runs of 10.0 sqmm and one runs of 10.0 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4.0 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4.0 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :-Two runs of 4.0 sqmm and one runs of 4.0 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including PVC conduit of suitable size with all accesories and fittings along with 1 run of single core 2.50 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :-Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including PVC conduit of suitable size with all accesories and fittings along with 1 run of single core 1.50 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :-Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S&F Socket Residual Current Device (SRCD) With Steel Enclosure two pin and earth plug including 25 Amps MCB SP complete all as specified and as directed (Make : Havells Cat Part No. DHDDCDP025202503 or equivelant model of make mention in PS)
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed.
S & F Distribution Board, TPN 4 Way with 200 amps rated bus bar, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed.
Supply, fixing, commissioning and testing MCB Four pole 63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed
Supply, fixing, commissioning and testing MCB SPN 6 to 32 Amps, 240 Volts,10KA, C curve complete all as specified and as directed
Supply, installation and testing inverter split AC units indoor/outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 star rating,copper condenser,copper cooling coil and EER 3.2 of capacity 2.0 TR including making holes of required dia on walls and necessary masonry work for making good distrubuted surface and match with the existing colour,PVC drain pipe of required length complete all as specified. Note :- Copper pipe including insulation and connecting cable exceeding 3.00 m , angle iron bracket will be measured and paid separately under respective item Make: Bluestar,Carrier,Voltas,LG, Daikin ,Hitachi ,O-General
Supply, installation and testing inverter split AC units indoor /outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 star rating,copper condenser,copper cooling coil and EER 3.2 of capacity 1.5 TR including making holes of required dia on walls and necessary masonry work for making good distrubuted surface and match with the existing colour,PVC drain pipe of required length complete all as specified. Note :- Copper pipe including insulation and connecting cable exceeding 3.00 m , angle iron bracket will be measured and paid separately under respective item Make: Bluestar,Carrier,Voltas,LG, Daikin ,Hitachi ,O-General
S & F voltage stabilizer of capacity 5 KVA, single phase, input working voltage 170-250 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. Make: V-Gaurd model no VG-500 or equivalent model of make mentioned in PS
S & F voltage stabilizer of capacity 4 KVA, single phase, input working voltage 170-270 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. Make: V-Gaurd model no VG-400 or equivalent model of make mentioned in PS
Supply and fixing copper pipe line heavy duty 5/8" dia with flair nuts and insulation as sunction/ discharge pipe of split AC/Tower AC complete all as specified and directed.
All as per item no 15 but 3/8" dia copper pipe for discharge line complete all as specified and directed.
All as per item no 15 but 1/4" dia copper pipe for discharge line complete all as specified and directed.
All as per item no 15 but 1/2" dia copper pipe for discharge line complete all as specified and directed.
S & F MS stand for mounting outdoor unit of Acs complete all as specified and as directed.
S & F Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed.
All as per item no 20 but three core 2.5 sqmm copper cable complete all as specified and as directed.
Supply and fixing LED building security light fittings 35 watt 230 V AC outdoor type with 4 KA surge protection with open and short circuit protection as per IS-10322 ,high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
S & F 32 mm dia light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket arm 1.5 mtr long complete with MS flat iron clamp (clamps shall be 32 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F switch modular single pole one way 16 amp 240 volts,1 Module with and including surface mounting PVC box with white cover plate and frame complete all as specified and as directed.
Taking down old unserviceable control cable of the fire alarm panel from site and making good the disturbed surface complete all as specified and directed
Taking down repeater panel,control panel,manual call point,heatand smoke detectors,loop sound from site and making good the disturbed surface complete all as specified and directed
S & F Fire alarm control panel complying with BSEN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules compactible with fire alarm repeater control panel complete all as specified and directed
S&F microprocessor based addressable fire alarm repeater panel for fire detection and data transmission through RS 485 panel bus complete with all accessories and tested as per NEPF 72 unit confirm to IS 2189 complete all as specified and directed.
S&F addressable type multisensor detector complying and certified to EN - 45 with heat and smoke combination as per IS: 11360 complete all as specified and directed
S&F addressable type explosive proof manual call point resettable type complete all as specified and directed.
Supply and fixing of addressable type loop sounders along with inbuilt isolators complete all as directed
S&F fire alarm cable stranded copper conductor1.5 Sqmm size (nominal area) XLPE insulated,cores laid up and FRLSH PVC outer sheath twin cable1100 Volt [ISI marked ] complete all as specified and as directed.
S&F rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 20 cm girth complete all as specified and directed.
Note for Item no 27 to 36:(i) Repai/replacement of defective components /parts/ accessories/ devices of UL listed /control wiring harness, checking and testing of FIRE DETECTION SYSTEM shall be carried out by the authorised personnel of authorised dealer of the system and quoted rate shall deemed to include all this aspect The contractor shall submit the Memorandum of Understanding (MoU)on stamp paper duly notarized with Original Equipments Manufacturer (OEM) or their accredited/authorized agencies, registered MES contractors or other contractors listed in appropriate category of CPWD/ Railways/ Other Government Agencies as approved by GE as applicable to the effect that repai/replacement of defective components /parts/ accessories shall be carried out under their overall supervision, maintenance and direction/ instructions within ten days after acceptance of tender, failing which the contract will be liable to be cancelled in terms of General condition of contract (IAFW-2249). (ii) Minor spares not included in this schedule but required for smooth functioning of the system shall be provided by the contractor without any extra cost to the Govt. (iii) The contractor shall be responsible for handing over the complete fire detection and fire alrm system alonwith all devices/ accessories / control wiring harness in serviceable condition at the time of completion of works duly inspected by the Engr-in-Charge jointly and inspection report of servicieablilty state of complete Fire alarm and detection system shall be submitted.
MURALI KRISHNA ASSOCIATES (BID ID -3286678)
SUPREET CONSTRUCTIONS (BID ID -3286344)
LALITHA SAI INFRA (BID ID -3282854)
P MURALIDHAR ENGINEERS AND CONTRACTORS (BID ID -3286340)
GAGANSRI INFRA (BID ID -3286381)
SREE VIJAYALAKSHMI ENTERPRISES (BID ID -3286189)
RATNA ENTERPRISES (BID ID -3286315)
HARSHITHA INFRA (BID ID -3286345)
SAI KRISHNA ASSOCIATES (BID ID -3286505)
SREE DURGA INFOTECH (BID ID -3281018)
M B CONSTRUCTIONS (BID ID -3286165)
GVR CONSTRUCTIONS (BID ID -3286560)
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .