Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | ₹11.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹11.1 L+₹2,466 (0.22%)Rejected-Finance | ₹11.1 L+₹2,466 (0.22%) | L2 | Rejected-Finance Second Lowest |
| 3 | L3₹11.3 L+₹13,164 (1.18%)Rejected-Finance | ₹11.3 L+₹13,164 (1.18%) | L3 | Rejected-Finance Third Lowest |
| 4 | L4₹12.3 L+₹1.2 L (10.7%)Rejected-Finance | ₹12.3 L+₹1.2 L (10.7%) | L4 | Rejected-Finance Fourth Lowest |
| 5 | L5₹12.7 L+₹1.6 L (14.5%)Rejected-Finance | ₹12.7 L+₹1.6 L (14.5%) | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹36,420
Closing Date
4 Jan 2022, 9:00 amClosed
Major Sameer Wadekar
Holta Cantt, Palampur
REPAIR/MAINTENANCE OF INTERNAL WIRING, MCBs, DBs, SUB MAIN WIRING AND ELECTRICAL FITTINGS IN OTM ACCN AT ZONE B PALAMPUR MIL STN
2021_MES_493086_1
GEP/ - /2021-22
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹36,420
Yes
25 Jan 2022
7 Dec 2021
6 Jan 2022
7 Dec 2021
4 Jan 2022
21 Dec 2021
Amount
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 6 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed. Notes:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' cappingshall be provided on surface with proper fixing clamps all as directed.
All as per the description of Serial item No 02 here-in-before but one 5 pin socket outlet, 6 amps on the same board complete all as specified and directed.
All as per the description of Serial item No 02 here-in-before but one 5 pin socket outlet, 6 amps, independent complete all as specified and directed.
All as per the description of Serial item No 02 here-in-before but for one 5 pin socket outlet 16 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
All as per the description of Serial item No 02 here-in-before but one light point controlled by 2-way switch complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 6 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed.
All as per the description of Serial item No 7 here-in-before but 6 Amp socket outlet on same board complete all as specified and directed.
All as per the description of Serial item No 7 here-in-before but socket outlet 6 Amps independent board complete all as specified and directed.
All as per the description of Serial item No 7 here-in-before but for one 6 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
All as per the description of Serial item No 07 here-in-before but one light point controlled by 2-way switch complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 6 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note:-(a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed.
All as per the description of Serial item No 12 here-in-before but 6 Amp socket outlet on same board complete all as specified and directed.
All as per the description of Serial item No 12 here-in-before but socket outlet 6 Amps independent board complete all as specified and directed.
All as per the description of Serial item No 12 here-in-before but for one 6 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
S&F 2 way switch, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F switch piano, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 6 A complete all as specified and directed.
S&F switch socket outlet combined 2 in 1, 3 pin 6 amp and 16 amp flush type, 240 volts ISI marked complete all as specified and directed.
S&F socket outlet 3 pin, 16 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
S&F switch piano, flush type single pole, one way 16 Amps, 240 volts ISI marked complete all as specified and directed.
S&F ceiling rose, 3 terminal surface type complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F electric bell ding dong, AC 230 Volts, single pole complete all as specified and directed.
S&F bell push flush type single pole one way 5 amp complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
S&F modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F modular Fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
S&F 18W tube light fitting (batten and LED tube rod), surface and wall mounted LED batten (overall size 1182x23x37 mm) with aluminium housing and integrated electronic driver having THD<20% suitable for 18W LED tube rod 4ft long ultra bright LED polycarbonate tubelight with THD<10% with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed. . Make: Havells Cat Part No. for batten LUMILINEPLUSBS18WLED865SPCSS and Cat Part No. for tube rod PHOTONULTRA2.01213T8SSTL18WLED865SPC or equivalent make and Cart Part as approved by GE.
S&F 2ft length, 10W LED tube light fitting, surface and wall mounted LED batten with aluminium housing & integrated electronic driver having THD<20%, with tube rod complete all as specified and directed. Make: Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent make and Cat Part as approved by GE.
S&F environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head fitting LED luminaire comprising of high brightness LEDs 10 watt, IP66 protection class complete all as specified and directed.
S&F 595x595x70mm size panel, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs 34/42W as light source, suitable for Armstrong/Grid ceiling complete all as specified and directed. Make: Havells Cat Part No. PLUTONEO2X2PLR34WLED857S/PLUTONEO2X2PLR42WLED857S or equivalent make and Cat Part as approved by GE.
S&F Sheet metal enclousers, TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F MCB SP 6 to 32 Amps, 240V, 10 KA 'B' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN 32 Amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN 40 to 63 Amp rating 240V, 10KA 'B' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB TPN 63 Amps, 10 KA 'B' curve, 415V in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 6.00 Sqmm for phase and neutral and one run of 6.00 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS-H, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 4.00 Sqmm for phase and neutral and one run of 4.00 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS-H, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
Taking down old unserviceable earthing and M&L earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
Charges for attending E/M petty complaint in respect repair/rectification of fault in electric fitting MCB DB's, internal wiring LT Panel and fixture and rectify the faults and replacement of unsv any type of fitting/fixture, MCB's, any type, bakalite sheet restore the electric supply and made the item functionable light point, fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical acessories and day to day /door to door maintenance, making the points/accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 mtr) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses all as specified and as directed. The scope also include cutting of existing bakelite sheet to accommodate new wiring acessories all type electric fitting/fixture. (Accessories shall be paid under respective items).
Notes : Any other replacement of major items shall be measured & paid under respective items as supply only. Fixing charge of fitting/fixture and MCB's of any type is deemed to be included in the above item.
(i) Contractor representative/engineer will report to complaint cell for morning and afternoon to collect routine/urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure deployed of sufficient manpower with equipped all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be repaired and got signature of user's and will be deposited to complaint cell within 24 hrs. In case of any delay in attending the complaint more than 12 hrs after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (iii) If the Contractor did not attend complaints, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deem to included in the item for repair i.e. Electrician/Helper, as all the items of CA are to be supply and fixed by the contractor. (v) All the complaint slip, register and connected document will be provided by the contractor without any extra cost. (vi) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano flush button type 6 amps single pole one way. complete all as specified and directed.
Supply only socket outlet multipurpose 2/3 pin 6 amps flush button. complete all as specified and directed.
Supply only bell push flush type 5 amps complete all as specified and directed.
Supply only switch piano flush button type 16 amps single pole one way. complete all as specified and directed.
Supply only Switch socket combination 6/16 A 250V AC universal with box in polycarbonate. complete all as specified and directed.
Supply only socket outlet multipurpose 2 in 1, 6 and 16 Amps. complete all as specified and directed.
Supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections. complete all as specified and directed.
Supply only electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers. complete all as specified and directed.
Supply only single core flexible PVC cable 1.5 sqmm of standrad copper conductor pvc insulated unsheathed cables of 1100 volts complete all as specified and directed.
Supply only lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed.
Supply only double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity,
Supply only Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity. complete all as specified and directed.
Supply only Environmental friendly, ultra modern, energy saving, surface mounted,decorative oval bulk head edgy-fit LED 10 Watt luminaire comprising of high brightness LEDs complete all as specified and directed.
Supply only surface and wall mounting LED 20 watt batten with polycarbonate housing & integrated electronic driver of 4 ft length. complete all as specified and directed.
Supply only surface mounting 9 watt LED mirror light fitting of 2 ft length complete all as specified and directed.
Supply only Decorative walll light fixture made up of Polycarbonate, Spiral B-22 Base suitable for including LED Bulb. complete all as specified and directed.
Supply only surface and wall mounting LED 20 Tube rod of 4 ft length. complete all as specified and directed.
Supply only T5/T8 tube rod 14 watt 2 feet (2700K/6500K as per requirement) complete all as specified.
Supply only electronic chock 14 watt, PF > 0.9 suitable for T5/T8 FTL fitting for easy connections complete all as specified.
Supply only PVC casing caping of size 20mm complete all as specified.
Supply only rigid non-metallic PVC conduit of size 20mm complete all as specified.
Supply only PVC surface box 3 module with 6 amp switch and socket complete all as specified.
Supply PVC surface box 3 module with 16 amp switch and socket complete all as specified.
Supply only PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 2.5 sqmm complete all as specified.
Supply only PVC insulated & unsheathed FRLS-H multistrand wire copper conductor wire 1100 volt grade of size 4.0 sqmm complete all as specified.
S&F switch piano, flush type single pole two way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for credit to contractor and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down old unserviceable sub main wiring of any size & type complete all as specified and directed.
M/s Raj Construction
BHARDWAJ BUILDERS
M/S MALHI CONSTRUCTIONS
M/S R S Kaushal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .