| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹33.8 L+₹2.1 L (6.52%)Rejected-Finance H NO 786 ANAND VIHAR COLONY PILIBHIT BYPASS BAREILLY UP PIN 243005 | BAREILLY | UTTAR PRADESH | 243005 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹35.4 L+₹3.7 L (11.6%)Rejected-Finance 121 BEHARIPUR MEMARAN BAREILLY UP PIN 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance Not being L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
25 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Shilpam Bharali
Garrison Engineer (AF) Military Engineer Services, Bareilly 243002 (UP)
8769 SPECIAL REPAIRS TO TECH FLIGHT HANGAR DOOR OF 111 HU AT AF STATION BAREILLY
2023_MES_630206_1
8769/E8
Open Tender
Civil Works
Item Rate
180 days
Bareilly
Class D
Category a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Bareilly
₹72,000
Yes
9 Jan 2024
28 Nov 2023
27 Dec 2023
28 Nov 2023
25 Dec 2023
13 Dec 2023
Amount
Taking out carefully existing motor operated hangar door leaves with steel structure each of approx size 7.50 m X 8.50 m, top rollers & bottom wheels, bottom rails including CGI sheet coverings (without damaging), disconnecting all electrical parts i.e. motor and cable etc. complete with hydraulic crane or other suitable mechanical tools, and manpower and placing the same on leveled ground carefully for carrying out repair/ replacement of damaged sections as detailed here-in-after complete all as specified and directed. Note-(i) T&P required for taking down the door for repair shall be arranged by the contractor at his own and the unit rate quoted shall include the cost thereof. No claim whatsoever on this account shall be entertained. (ii) Replacement of defective steel members, CGI sheets, items shall be measured and paid against respective items of this schedule.
M&L in repairs for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W(Gde-E-250) Quality A, as in existing main horizontal/ vertical sections, bracings, plate at bottom for wheel fixing of MS framed structure of hangar's doors, other connecting plates and welding wherever required after making them perfectly straight and aligned and complete all as specified and directed.
M&L in repairs for mild steel tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe- 290 Gde-E-165 complete all as specified and directed.
Demolition of cement Concrete in ground floors and pavings, any thickness including taking out embedded steel rails and associated members, (below or above ground level), by diamond cutter and breaking by mechanical tools including removing demolished spoils exc 1.5 Km but n.exc 5 Km and depositing where ever required complete all as specified and directed.
M&L in repairs for rolled mild steel sections for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, drilling holes for anchor bolts etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of standard sleeper of ISMC 150 (channeled sleepers Fe 410-W (Gde-E-250, Quality A) & J- bolt of dia 12mm. 450mm length shall be fixed on sleeper to align it on floor, to support the rails of hangar door wheel on it after making them perfectly straight/ leveled/ aligned and checked with laser leveling instrument, inclusive of J-bolts complete all as specified and directed.
S&F in repairs Standard rails (30/ 50 lb) or equivalent section including stoppers at specified locations to restrict further movement of doors, fixed on sleeper of ISMC 150 @ distance 750mm (channeled sleepers shall be measured and paid for in relevant items) to support the hangar door wheels on it after making them perfectly straight and checked with laser leveling instrument, and J- bolt of dia 12mm. 450mm length shall be fixed on sleeper to align it on floor and complete all as specified and directed
S&F in repair set of two roller wheel assembly (bottom wheels:- one roller wheel shall be fitted with sprocket for motorization arrangement and another without sprocket to each leaf including nut bolts, connecting plates etc) for movement on bottom rail with each effective force of 100 Kgf at 1.6 m height from the floor. The bottom wheel shall be of adequate strength to sustain the load of door leaf, made of high tensile steel machined with high precession, double flanged ( 18mm flange) fitted with heat resistant maintenance free self lubricating sealed bearings. The wheel diameter shall not be less than 300 mm & the shaft diameter shall not be less than 40mm guide channels and 2 Nos. two wheel assembly for bottom support suitable to enable movement of each shutter by application of 100 Kgf of force at 1.6m height from the floor. Bottom wheel shall be designed to take all the load of door leaf in motion/ High wind pressure and to protect the door leaf from de-railing the rail complete all as specified and directed. Note :- Make & quality as approved by GE
S&F in repair set of two roller assembly (one at each support) for top support of each door leaf to move in guide channels at top guide. The top wheel shall be made of high tensile steel, machined with high precision fitted with heat resistant maintenance free self lubricating sealed bearings. the wheel diameter shall not be less than 150 mm & the shaft dia shall not be less than 40mm. Top wheel shall be designed to take all load in motion / high wind pressure and to protect the door leaf from de-railing / falling of guide complete all as specified and directed. Note :- Make & quality as approved by GE.
M&L for plain cement concrete 1:1½:3, Type A1 (using 20mm graded stone aggregates) in pavement/ hard-standing of any thickness and finishing surface of concrete by brooming complete all as specified and directed.
M&L for forming construction joint 30mm deep X 10mm wide by cutting with diamond cutter and filled with Grade 'B' sealing compound complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness as in roof covering, door cladding/ covering etc complete all as specified and directed.
S&F 0.63mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap having zinc coating @ 275 gram per sq.m inclusive of both sides, fixed with L-type or J-type or cranked hook bolts, as in roof, walls, door cladding/ covering etc. complete all as specified and directed.
Fixing only galvanized corrugated iron (CGI) sheeting, any thickness (old serviceable sheets shall be used) with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts, as in roof, walls etc. complete all as specified and directed.
S&F 0.8 mm thick Plain, galvanized, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings, funnels (length and girth as fixed) with grade of zinc coating 275, Joints sealed to make it leak proof by suitable sealing compound and fixed and connect with SWR pipe where ever required and complete all as specified and directed.
Refixing of hangar door leaf in the same opening (each of approx leaf size 7.50m x 8.50m) including straightening of displaced/ distorted steel members and fixing the same by welding in the correct position/ true to alignment as required, replacement of worn out nut and bolts, repair of welded joints wherever required etc. including installation of motorization arrangement, connecting chains, cables complete using hydraulic crane or other suitable mechanical tools & necessary scaffolding; for smooth functioning of door in all respects to the user's satisfaction complete all as specified and directed. Note-(i) Replacing of MS structural members, PGI & CGI sheets covering shall be measured and paid for under relevant items of this schedule. (ii) T&P required for refixing of hangar door leaves shall be arranged by the contractor at his own and the unit rate quoted shall include for the cost thereof and no claim whatsoever on this account shall be entertained.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint of five different colours in camouflage pattern as approved by the GE complete over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of old painted steel surfaces and applying a coat of synthetic enamel paint of five different colours in existing camouflage pattern complete all as specified and as directed.
M&L in repairs sub main wiring concealed complete with two runs of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F die cast aluminium LED Flood light not less than 120W IP 66 with high power LEDs, integral flood light with driver inside a PDC housing including all fittings, clamps, angle frame etc for fixing on wall/ pole etc with all accessories pre-wired including taking down existing unserviceable fitting complete all as specified and directed [Make: Cat Part No. JETAIRISFL120WLED757ARWBLTG of make: Havells/ Cat No. LF20-132-060-57-G2 of make: Wipro or BVP192 LED110 CW HO NB FG GR PSU of make: Philips].
S&F in repairs rigid non metallic PVC conduit ISI marked of size 25mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hook etc. over the surface/recess complete all as specified and directed.
Supply, lay, connect, test and commissioning of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade of size 4 core 16 sq.mm complete including taking down existing cable all as specified and directed. [Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation & earth work will be measured and paid separately].
S&F in repairs sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F in repairs MCB SPN, 240 volts, 6 to 32 Amps, C curve 10 KA all as specified and as directed.
S&F in repairs MCB SP, 6 to 32 Amps, 230 V, C curve, 10 KA all as specified and as directed.
S&F in repairs PVC insulated flexible copper conductor cable of size 4 core, 2.5 sq.mm, sheathed 1100 Volt grade complete all as specified and as directed. [Make: Finolex/ Polycab/ Havells/ Plaza].
S&F in repairs flexible cable carrier as per existing size complete all as specified and as directed.
Supply, Installation, testing and commissioning of Motorization system of existing hangar door with facility of manual operation, Idler braking system, safety hooter cum flasher, auto limit power cut off, weather proof control panel with safety of motor system complete. with a guarantee period of 24 months for smooth jerk free forward and reverse smooth operation of door without any indication of De- railing from track. fully enclosed motor gear idler braking assembly with manual declutching facility chain sprocket assembly with foundation- one for each leaf of size 5m x10m. with weather proof control panel with safety device one for each motor system i.e. for each leaf. and auto power cut limit switches - one pair for each motor system i.e. for each leaf. and Hooter cum flasher - one for each motor system motor system i.e. for each leaf. and fire rated lope coated cable 2.5 mm x4 core -100 m each motor system i.e. for each leaf. and fire rated lope coated cable 0.75 mm x 2 core -150 m each motor system i.e. for each leaf. and Fire rated MS Conduit- 25 mm dia, approx 100m each motor system i.e. for each leaf. and festoon C- channel slider/rope wire cable carrier arrangement - complete for each motor system. Make : M/s Jugapro/ M/s AREEN Entrance Automation Pvt. Ltd/ Avians Innovations Technology Pvt. Ltd.
Horizontal Boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes of 80mm bore and making good the disturbed surface complete all as specified and as directed. [Note: GI pipe will be measured and paid separately]
S&F GI tubes 80mm bore dia light grade with all fittings laid in trenches or inserting in horizontal boring complete all as specified and as directed.
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
Supply and laying well burnt sub class ‘B’ bricks (old size brick) laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil all as specified and as directed.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point all as specified and as directed.
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16(R) of tender document i.e. Rs. 1,14,708.00
ZAIGHAM ENTERPRISES
M/s M Aali construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .