Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC 5TH FLOOR DP 9 P T I BLDG SALT LAKE SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹43.4 L+₹8.4 L (24.1%)Rejected-Finance SCHINDLER HOUSE MAIN STREET HIRANANDANI GARDENS POWAI MUMBAI 400076 MAHARASHTRA INDIA | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | L2 | Rejected-Finance Highest Quoted Rate. |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
16 Sept 2024, 12:00 pmClosed
SE, PWD, Kolkata Electrical Circle
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Vertical extension of the existing Hostel Building from 4th floor to 7th floor at West Bengal Judicial Academy New Town, Kolkata 700160- SITC of 2 nos 10 passenger lifts-2nd Call.
2024_WBPWD_721037_1
PWD/SE/KEC/NIT03(2nd Call)/24-25
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
WBJA, Salt Lake, Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹84,000
Office of the SE, PWD, Kolkata Electrical Circle
8 Apr 2025
24 Jul 2024
18 Sept 2024
24 Jul 2024
16 Sept 2024
2 Aug 2024
31 Jul 2024
Amount
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd. Make : OTIS / KONE/SCHINDLER
Type: Passanger Lift . Load : 10 Passenger / 680 Kg Control: Microprocessor based with serial communication , controller in shaft and user interface in landing. Drive : AC VVVF drive with feedback control (Closed loop) Machine:- Energy efficient machine: Gearless, without Machine Room . Position of Machine Room: MRL Speed: 1.5 Mtrs./ Sec Floor served: G + 7 Landing: 8 lands, all on same side Total Rise : 22.75 Mtr (Approx) Operation: Microprocessor based simplex full collective with or without attendant. Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator. COP and LOP must have stainless steel faceplate silver brushed with surface mounted button with braille. Button : All buttons on car& landing shall be luminious and encoded with braille on / off switc for lift ,fan, light, toggle switch or key switch for autometic / attended mode of operation. Display type : Color LCD / Segmented LCD / LED. Opration push button for lift maintainnence & service should be on top of the car. Travelling accuracy:± 5 mm(Micro levelling arrangement )
CAR Car inside As per OEM Car Entrance: Clear Opening:- 800mm x 2000mm protected with car door Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail. Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan. Car Ventilation: Pressure fan with anodised aluminium grill. Car Flooring : Decorative granite flooring (As per direcion of EIC and according to this Department's Order). Car Door: Stainless Steel centre opening (COPD)/Telescopic opening (TSPD) automatic door provided with AC V3F controlled door drive system with full height infrared curtain of light and mechanical force limiting divice. Landing Door: Stainless steel centre opening (COPD)/ Telescopic opening (TSPD) automatic door provided with AC V3F controlled door drive system with fire rating of 120 min. Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor / infrared detector.
PROTECTIVE DEVICES & OTHER ACESSORIES ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing / others. Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio & display indication. Emergency lighting in car: Battery operated emergency lighting in the lift car. Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room Emergency Alarm: Battery operated alarm bell system in lift car and control room Fireman switch: Fireman switch at main landing terminal. Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator. Car Parking at top floor at idle condition. Main wire rope/ Belt - As per manufacturer's standard conforming to IS. Auto Fan cutoff.
DIMENSION OF SHAFT & POWER SUPPLY Available Shaft Dimension: 1855 mm (W) X 1750 mm (D) Pit Depth :1600 mm (Bidder should visit the site) Overhead : 4500 mm ( (Bidder should visit the site) Electric power supply: AC 415 Volt 3phase, 50 Hz, terminated in BDB at top landing as per IS. N.B. 1) Rates should be quoted with minor civil works, wall cutting and mending good the damages to the original finish. 2) Necessary MS member eg; angle iron, MS channel brackets etc as required to be provided by the manufacturer.
SCHINDLER INDIA PRIVATE LIMITED (BID ID -5385290)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .