Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹7.6 L
EMD Value
₹19,067
Closing Date
23 Oct 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Assistant Executive Engineer Electrical HEED
O/o The chief Engineer, Harbour Engineering Electrical Sub Division, Kamaleswaram, TVPM
Electrical works-2025-26-Annual Maintenance of various harbours in kozhikode division-General Electrical Work
2025_HED_806355_1
HED/CEHED/TR/94/2025_6_11_10/1
Open Tender
Electrical Works
Item Rate
365 days
Kozhikode
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,685
₹19,067
31 Oct 2025
7 Oct 2025
25 Oct 2025
7 Oct 2025
23 Oct 2025
7 Oct 2025
Work Name:GENERAL-Electrical works-2025-26-Annual Maintenance of various harbours in kozhikode division-General Electrical Work
e following sizes in the existing masonry open duct as required.4 core 16 sq mmE90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp"90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest sizeÈ1.42:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.¶1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm¶OD10421/2024-2025:Engaging labourers for checking electrical installations, cable etc. and rectifying the faults if any as per the instruction form the departmental officers at site 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)WOD4850/2025-2026:Supply and installation of 100w Highbay LED, Bay light , System efficacy is 150 lumens/watt,Designed for operations under diverse environments ranging from -10ÚC to 55ÚC, IK08 polycarbonate cover provides strong protection under harsh conditions, Pressure die-cast housing offers excellent corrosion-resistance and robustnessOD4851/2025-2026:Supply and fixing pipe clamping arrangement using 30 cm, 65mm medium GI pipe supported by 50x50x6 mm Angle iron clamped on roof structure using 10 mm anchor bolt 4 nos and additional GI rods for fixing solar street light on builidng including all accessoriessetwOD4852/2025-2026:Supplying and fixing all in one solar street light 40W with high efficiency mono crystalline solar PV module LiFePo4 battery with in built BMS technology MPPT charge controlller Aluminium extruded body IP65 with serviceable battery compartment high efficacy LED greater thatn 150LPW and PIR dimming provided for optimizing battery autonomy on roof structure.æ9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)ü9.3.29:Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mmô14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).cumÚOD4859/2025-2026:Scrapping and cleaning the surface and painting two coats of best quality synthetic enamel paint of approved color over two coat of epoxy based industrial primer on electrical panel including all cost.sqmOD4860/2025-2026:Supplying and making end termination nickel plated single compression brass cable gland for 4 core 4 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.ãOD4861/2025-2026:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm Civil worksà15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.61 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
biddockozhikode.pdf
Tender Documents • 1.66 MB
BOQ_1343125.xls
BOQ • 0.33 MB
dateextensiondraft.pdf
PDF • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .