Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | ₹25.3 L Quoted ₹27.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹33.6 L+₹5.7 L (20.6%)Rejected-Finance BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹33.6 L+₹5.7 L (20.6%) | L2 | Rejected-Finance Being 2nd Lowest |
| 3 | L3₹41.1 L+₹13.3 L (47.7%)Rejected-Finance | ₹41.1 L+₹13.3 L (47.7%) | L3 | Rejected-Finance Being 3rd Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 May 2022, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR TO INTERNAL WIRING AND FITTINGS CEILING FANS,EXHAUST FANS, AIR CIRCULAR PVC EXHAUST FAN SUB MAIN WIRING DB,S AND CONNECTED WORK ALONGWITH BLDG SECURTY LIGHT OF OTM OR MD ACCN UNDER GE (E) BAREILLY
2022_MES_520883_1
8986/E8
Open Tender
Civil Works
Item Rate
183 days
GE EAST BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
BAREILLY
₹90,000
Yes
1 Jul 2022
29 Apr 2022
28 May 2022
29 Apr 2022
26 May 2022
12 May 2022
29 Apr 2022 - 5 May 2022
Amount
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan / sockets/ power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed.
Taking down electric meter and disconnecting, removing to store for keeping in safe custody for refixing etc Complete all as specified & as directed.
Taking down main switch / MCB/ DBS including MC BS etc of any size removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc Complete all as specified & as directed.
Taking dowm submainwiring/service cable including earth wire and making good disturbed surfaces to match with the existing surfaces of walls incuding removing of site complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100 volts, drawn through & including concealed 20 mm rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches, switch sockets, sockets, regulators etc with 3 mm thick hylum laminated sheet cover including cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for:- NOTE: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza (c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
All as per Srl item No 5 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5 Sqmm size, 1100 volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall / ceiling / truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5 Sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of MS boxes / non metallic rigid PVC Terminal boxes with cover plate in any size fixed on wall for fixing the switches, switch sockets, sockets, regulators etc complete all as specified for:- NOTE: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab / Havells / Finolex / Plaza (c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
One light point controlled by two way switch.
All as per Srl item No 7 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through & exisiting rigid non metalic PVC conduit with all accessories fixed on wall/ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switches with 3 mm thick hylum laminated sheet cover plate in any size fixed on wall for fixing the switches, switch sockets, sockets, regulators etc complete all as specified for:- NOTE: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza (c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light point / Fan point / Exhaust point / Bell point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
One light point controlled by two way switch.
All as per Srl item No 9 here in before but One 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for wiring and earth wire
S&F switch piano flush type single pole one way 5 Amps Complete all as specified & as directed.
S&F in repairs Modular switch one way 6 Amp, one module,. Complete all as specified & as directed.
S & F in replacement of switch, piano flush type, single pole, one way, 5/6 Amps complete all as specified and directed.
Supply and fix switch sockets combination 5 pin 5 Amps flush type 240 Volts AC complete all as specified and directed.
S&F in repairs Modular Switch one way 16 Amp, one module Complete all as specified & as directed.
S & F in replacement of Bell push, 5/6 Amps, 240 volts SP complete all as specified and directed.
S&F in repairs Modular Bell push 6 Amp one moduleComplete all as specified & as directed.
S&F switch Socket combination 2 in 1, 3 pin 5 Amp flush type.Complete all as specified & as directed. make- Havells, Anchor.
S&F in repairs Modular Socket 6 Amp, 2 / 3 pin combined 2 module, Complete all as specified & as directed
S&F switch socket combination 2 in 1, 3 pin 6 Amp and 16 Amps Complete all as specified & as directed
S&F in repairs Modular socket 6A/16A, 2/3 pin combined 2 module. Complete all as specified & as directed.
S & F in replacement of Bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as directed.
S&F Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings.Complete all as specified & as directed.
S&F in repairs Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings.Complete all as specified & as directed.
S & F Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
Fixing only old serviceable light fittings any type received from item no-1 above including electric connection & cleaning complete.
Fixing only old serviceable LED Tube light fittings 18/20 Watt, 4' complete received from item Nos.-1 above including cleaning & connecting up with 3 core flexible copper conductor cable of suitable size.
S & F in repairs Lamp LED 7/9 Watt 230 Volt complete all as specified and directed.
S & F in repair LED retrofit tubes18/ 20 Watt, 4' Complete all as specified & as directed
S & F in repairs LED Tube light fittings 20 Watt ( T-8 ), 4' complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size Complete all as specified & as directed.
S & F in repairs LED Tube light fittings 10 Watt ( T-8 ), 2' complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size Complete all as specified & as directed.
S& F in repairs Noble LED strip light 6 watt IP 20 with LED Driver+ power cord cut-table after 3 LED 50000 burning hours(Amber)Smfor POP complete all as specified and directed
S&F in repairs LED bulk head luminaire 10 watt with Engineering plastic housing and oval shaped clear prismatic diffuser, heat sink integrated including one no. 12Watt LED lamp Complete all as specified & as directed. Make: C&S/Havells/Bajaj/Phillips/ Crompton as approved by GE.
S & F in repairs LED Ceiling light 9Watt round surface mounted die cast aluminium housing with frosted diffuser including LED lamp 12 Watt Complete all as specified & as directed. .Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S &F in repairs Recess mounting LED ultra slim Ceiling light 2'X2', 35/36 Watt complete all as specified and directed..Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S &F in repairs surface mounting type LED ultra Ceiling light 2'X2', 28 Watt complete all as specified and directed..Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S &F in repairs surface mounting type LED ultra Ceiling light 1'X1', 18 Watt complete all as specified and directed. Make: C&S/Havells/Bajaj/Phillips /Crompton as approved by GE.
S& F in repairs round shape 6watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as approved by GE.
S & F in repairs LED Wall bracket type CITY-2 fitting 9 Watt complete. Make: C&S/Havells/Bajaj/Phillips / Crompton or equivalent as approved by GE.
S& F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscap luminaire with power LEDs of 20 Watt as light source of 20 Watt suitable for pole dia 76 mm of complete all as specified and directed
S & F in repairs 36 watt PL-L/CFL lamp 4 pins for 60cmx60cm ceiling light fitting complete. (Make : Philips/bajaj /Osram or equivalent as approved by GE.
S&F in repairs Electronic ballast 36 watt for 60cmx60cm ceiling light fitting 36watt Complete all as specified & as directed.
S&F in repairs stepped, (socket/switch type) electronic fan regulator flush type Complete all as specified & as directed. 180 Watt, 240 Volts. Make- Anchor/Bajaj or equivalent as approved by GE.
Fixing only and connecting electric meter upto 25 Amp(Item received form ser No 2 here in before) complete all as specified and as directed.
Fixing only sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor recieved fron item No 4 above alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor drawn in & including PVC conduit/casing capping all as directed.
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in & including PVC conduit all as directed.
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in & including PVC casing & capping complete all as specified and as directed.
M & L in repairs for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in & including PVC conduit complete all as specified and as directed.
M & L in repairs for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in & including PVC casing & capping complete all as specified and as directed.
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in existing conduit all as directed.
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn in existing conduit all as directed.
S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 250 X 200 X 50 mm deep complete. ISI marked.
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 300 x 250 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified
S&F in repairs single pole and neutral enclouser having IP -67 protection with a three pin & earth plug with socket complete and one SP, 20 A , 240 V MCB complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volt, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 12 way, 240 V, double door single pole & neutral with 200 Amps rated bus bar Complete all as specified & as directed.
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 415V, double door tripple pole & neutral with 200 Amps rated bus bar Complete all as specified & as directed.
S&F in repairs MCB 415V, 10KA, TPN , 63Amps to 100Amp complete all as specified and directed.
S&F in repairs MCCB 415V, 16KA, 4 Pole , 63Amps to 100Amp complete all as specified and directed.
S&F in repairs MCB single phase and neutral 16A-63A, 230V 10KA. B' curve type complete all as specified and directed.
Fixing only old serviceable MCBs single phase and neutral 16A-63A, 230V 10KA Complete all as specified & as directed. MCB received from item No-4 here in before.
S&F in repairs MCB SP 6A-32A, 230V. 10KA. B' curve type complete all as specified and directed
Fixing only old serviceable MCB SP 6A-32A, 230V. 10KA Complete all as specified & as directed. ( MCB received from item No-3 here in before).
S & F in repairs Cable weather proof flat twin core with aluminium conductor multi stranded of size 6 sqmm, 1100Volts grade complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts,check nuts, nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-I 2009. GI wire protected by GI pipe light grade 15mm dia connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, earthing pit in PCC (1:3:6) type C1,RCC (1:2:4) type B1 precast cover slab with one handle made out of 8 mm dia round bar,20 mm dia (medium grade) watering pipe and providing layer of charcoal or coke and salt in alternative layers complete as specified or directed & including testng on completion.( NOTE:- Tenderers may note that amount of credit will be deducted from the total amount arrived at the time of Acceptance of contract.)
Taking down Ceilings/Walls/AirCirculator and refixing the same after repairs/painting in original position including fixing of nut, bolt & split pin and provision of new three core flexible PVC insulated multistranded copper conductor cable 1.0 sqmm from ceiling rose to fan complete all as specified and directed by Engr-in-charge.(Note- Repair work/ painting and cable for connection shall be measured and paid separately )
All as per item no. 76 (here in before) but Exhaust fans of any sweep complete as specified or directed
M&L for dismantiling the ceiling fan of any sweep/wall mounted fan/Air circulator fan , cleaning the surfaces throughly and applying a spray coat of synthetic existing enamel paint over one coat of red oxide primer including rewriting MES no. on fan complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 70 here in before but Exhaust fans of any sweep.
M&L for dismentiling the Stator & Rotor of ceiling fan of any sweep,taking out the burnt copper wire, cleaning the Stator & Rotor with CTC, rewinding the fan with existing gauge and same nos of turns with super enameled copper including varnishing, baking, replacement of sleeves etc and reassembling the fan & testing, complete all as specified and directed.
All as per Srl item No 72 here in before but Exhaust fan of 300mm sweep complete all as specified & directed.
All as per Srl item No 72 here in before but Exhaust fan of 375/450mm sweep complete all as specified & directed.
All as per Srl item No 72 here in before but Wall mounted fans complete all as specified & directed.
Dismantiling the ceiling fan of any sweep, examine complete part thoroughly , oiling, greasingall parts and complete overhauling of fan including replacement of spares such as bearings, bushes, split pin, nuts, bollts, clamps, screws and reassembling complete fan and making fully functional coplete all as specified and directed by Engr-in-Charge. [Note:- Spares like Bearings, Bushes, Capacitor & others shall be measured and paid separetely.]
All as per Srl item No 76 here in before but Exhaust fans of any sweep complete all as specified & directed.
All as per Srl item No 76 here in before but Wall mounted fans complete all as specified & directed.
All as per Srl item No 76 here in before but Air Circulator fans complete all as specified & directed.
Supply & Fix in repairs metal bush made out of Gun metal/Brass suitable for ceiling fans/ Exhaust fans of anysweep.
Supply& fix in repairs ball bearings suitable for ceiling fan of any sweep complete all as specified & directed.
Supply & fix in repairs ball bearings suitable for Exhaust fan of any sweep complete all as specified & directed.
Supply & fix in repairs capacitor 2.5 Mfd, 415 , 50Hz. Make- Universal/Tibcon or equivalent as approved by GE.
Supply & fix in repairs capacitor wall mounted fan 2.0 Mfd, 415V, 50Hz Make- Universal/Tibcon or equivalent as approved by GE.
Supply & fix in repairs capacitor 3.15/4.0 Mfd, 415 V,50Hz Make- Universal/Tibocon or equivalent as approved by GE.
Supply & Fix in repairs fan hook clamps steel suitable for ceiling fan hanging complete all as specified & directed
Supply & fix in repairs rubber reel for ceiling fan hanging complete all as specified & directed
Supply & Fix in repairs fan down rod made of 15 mm bore GI pipe, 60 cm long complete all as specified & directed.
Supply & Fix in repairs Canopy PVC suitable for fixing on fan down rod with screws etc complete all as specified & directed
Supply & Fix in repairs Fan blades complete with nuts & washers and complete all as specified & directed.
Supply & Fix fan hook steel with suitable nut bolts for fixing arrangement on GI Pipe for ceiling fan hanging complete all as specified & directed
Supply & Fix nut, bolt,washer and split pins suitable for fixing of fan clamps with down rod& hanging of ceiling fan complete all as specified & directed
Supply & Fix in replacement of burnt rotor assembly complete for 1200mm sweep ceiling fan all as specified and directed.
Supply &Fix in replacement of burnt stator assembly complete for 1200mm sweep ceiling fan all as specified and directed.
Supply & fix in repairs metalic Exhaust fan blade with MS frame for 300mm sweep Exhaust fan complete all as specified and directed.
Supply & fix in replacement of burnt motor kit for PVC Exhaust fan 250mm sweep complete all as specified and directed.
S&F Ceiling fan complete with all accessories including electric connection with three core flexible PVC insulated copper conductor multistranded cable 1.0 sqmm complete all as specified and directed.
S&F in repairs PVC insulated sheathed flexible multistranded copper conductor cable 3core 1.0 sqmm, 1100 Volts grade complete all as specified and directed.
S&F in repairs GI bracket made out from GI pipe 25/32mm dia, 1.20 m long fixed on wall with and including nut, bolts and GI clamps of size 25x4mm as required & including painting etc complete.
S&F in repairs LED building security light fitting 20 Watt 230 Volts AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket and corrision resistant including thermal management in multiple optics complete IP 65/66 protection including electric connections etc complete all as specified & directed.
S&F in repairs LED building security light fitting 30 Watt 230 Volts AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket and corrision resistant including thermal management in multiple optics complete IP 65/66 protection including electric conection complete all as specified & directed.
prabhave traders
LEEJA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .