| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹38.0 L+₹1.8 L (4.90%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹38.6 L+₹2.3 L (6.36%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹38.9 L+₹2.6 L (7.19%)Admitted-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Admitted-Finance | |
| 5 | L5₹39.0 L+₹2.7 L (7.46%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Dwarka Pershad Radhey Ramanlal L1 | M/s RAMA LAKSHMI CONSTRUCTIONS L2 | Vipin Kumar and Brother L6 | GUTHIKONDA BROTHERS No Rank | M/S SRINIVASA CONSTRUCTION L4 | Venkat Ramaiah L5 | Sadrush Enterprises L7 | S J REDDY L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete or surkhi filling of any description and in any position not otherwise specifically provided for Roof treatment treatment etc complete all as specified and as directed. | 32 | Cum | 300 ₹9,600 | 500 ₹16,000 | 30 ₹960 Lowest | - | 900 ₹28,800 | 795 ₹25,440 | 500 ₹16,000 | 405 ₹12,960 |
| 2.00 | M&L Cement concrete type B-1 1:2:4 (20mm graded aggregate) in roof padding concerte of average 50 mm thick with liquid water proofing compound as per manufacturers instructions etc complete all as specified and as directed. Note: WPC will be measured & paid separately under relevant Item | 270 | Sqm | 250 ₹67,500 Lowest | 300 ₹81,000 | 350 ₹94,500 | - | 380 ₹1,02,600 | 410 ₹1,10,700 | 270 ₹72,900 | 270 ₹72,900 |
| 3.00 | M & L Cement concrete type B-0 1:2:4 (12.5mm grades aggregate) in haunching concrete etc complete all as specified and as directed | 2 | Cum | 5,000 ₹10,000 Lowest | 6,500 ₹13,000 | 6,000 ₹12,000 | - | 5,000 ₹10,000 Lowest | 8,250 ₹16,500 | 6,000 ₹12,000 | 8,100 ₹16,200 |
| 4.00 | M&L for Rendering 10mm thick in cm 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surface is still green including finished even and fair etc complete all as directed. Note: WPC will be measured & paid separately under relevant Item | 270 | Sqm | 300 ₹81,000 | 250 ₹67,500 | 250 ₹67,500 | - | 220 ₹59,400 | 195 ₹52,650 Lowest | 200 ₹54,000 | 225 ₹60,750 |
| 5.00 | Cleaning the roof surfaces and applying oil bound bitumen primer @0.20 Kg per Sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4 Kg per Sqm reinforced with non woven polyster mat weight not less 160 gm per Sqm having softening point not less than 140 Degree centgrade, lengitudinal tensile strength not less than 800N per 5 cm teasing strenght of 180N with minimum of 10 cm side laps and 15 cm end laps by application of torch. Applying a coat of blown grade hot bitumen over the membrane @ 1.20 kg/sqm as per manufacturer instructions complete as directed | 410 | Sqm | 600 ₹2,46,000 | 750 ₹3,07,500 | 730 ₹2,99,300 | - | 700 ₹2,87,000 | 550 ₹2,25,500 | 780 ₹3,19,800 | 504 ₹2,06,640 Lowest |
| 6.00 | M&L for applying one coat of solar reflective bituminous Aluminium paint over a surface of APP water proofing membrane @ 0.1 Kg/Sqm etc complete all as specified and as directed. | 190 | Sqm | 30 ₹5,700 Lowest | 80 ₹15,200 | 70 ₹13,300 | - | 70 ₹13,300 | 37.5 ₹7,125 | 55 ₹10,450 | 81 ₹15,390 |
| 7.00 | S&F cement concrete tiles 20-30cm X 20-30 cm X 20mm thick machine pressed set jointed and pointed in neat grey cement slurry in floors over and including 20mm thick screed bed in CM 1:4, etc complete all as specified and as directed. | 220 | Sqm | 650 ₹1,43,000 | 700 ₹1,54,000 | 800 ₹1,76,000 | - | 970 ₹2,13,400 | 625 ₹1,37,500 Lowest | 1,000 ₹2,20,000 | 990 ₹2,17,800 |
| 8.00 | Removal of debris (Aggregates) obatained from demolition including loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed. | 52 | Per Load | 500 ₹26,000 | 800 ₹41,600 | 500 ₹26,000 | - | 350 ₹18,200 | 260 ₹13,520 | 300 ₹15,600 | 180 ₹9,360 Lowest |
| 9.00 | M&L for Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding , any type , any location/height( roof, parapet walls near pipes etc) and spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions after removing roots from wall slabs for preventing the regrowing and making good the disturbed portion using PCC 1:2:4 type B-0 with 12.5mm graded aggregate and plaster in CM 1:3 (Size of the disturbed portion 150X150X150mm) etc complete all as specified and as directed. | 20 | Each | 500 ₹10,000 | 500 ₹10,000 | 600 ₹12,000 | - | 72 ₹1,440 Lowest | 150 ₹3,000 | 120 ₹2,400 | 108 ₹2,160 |
| 10.00 | Cutting out V groove on cracks of walls and cleaning out, wetting, grouting with crack filler (Dr Fixit or equivalent) mixing with cement slurry, making good the surface by using CM 1:3 or PCC 1:2:4 type B-0 as required at site, as per manufactures instuctions, of any description and in any position, with necessary scaffoldings, as approved by Engr in charge | 40 | RM | 75 ₹3,000 Lowest | 120 ₹4,800 | 120 ₹4,800 | - | 111 ₹4,440 | 100 ₹4,000 | 80 ₹3,200 | 144 ₹5,760 |
Tender Value
₹41.4 L
EMD Value
₹82,834
Closing Date
10 Sept 2026, 6:00 pmClosed
GE (AF) Hyderabad
GE (AF) Hyderabad
ADDN/ ALTN TO CERTAIN SMQS (WARRANT RANK STATUS) AT AFA HYDERABAD
2026_MES_784409_1
8732/E8
Open Tender
Civil Works
Item Rate
Hyderabad
As per NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹82,834
Yes
18 Sept 2026
14 Aug 2026
12 Sept 2026
14 Aug 2026
10 Sept 2026
28 Aug 2026
14 Aug 2026 - 27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of cement concrete or surkhi filling of any description and in any position not otherwise specifically provided for Roof treatment treatment etc complete all as specified and as directed. | 32 | Cum | - | - |
| 2 | M&L Cement concrete type B-1 1:2:4 (20mm graded aggregate) in roof padding concerte of average 50 mm thick with liquid water proofing compound as per manufacturers instructions etc complete all as specified and as directed. Note: WPC will be measured & paid separately under relevant Item | 270 | Sqm | - | - |
| 3 | M & L Cement concrete type B-0 1:2:4 (12.5mm grades aggregate) in haunching concrete etc complete all as specified and as directed | 2 | Cum | - | - |
| 4 | M&L for Rendering 10mm thick in cm 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surface is still green including finished even and fair etc complete all as directed. Note: WPC will be measured & paid separately under relevant Item | 270 | Sqm | - | - |
| 5 | Cleaning the roof surfaces and applying oil bound bitumen primer @0.20 Kg per Sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4 Kg per Sqm reinforced with non woven polyster mat weight not less 160 gm per Sqm having softening point not less than 140 Degree centgrade, lengitudinal tensile strength not less than 800N per 5 cm teasing strenght of 180N with minimum of 10 cm side laps and 15 cm end laps by application of torch. Applying a coat of blown grade hot bitumen over the membrane @ 1.20 kg/sqm as per manufacturer instructions complete as directed | 410 | Sqm | - | - |
| 6 | M&L for applying one coat of solar reflective bituminous Aluminium paint over a surface of APP water proofing membrane @ 0.1 Kg/Sqm etc complete all as specified and as directed. | 190 | Sqm | - | - |
| 7 | S&F cement concrete tiles 20-30cm X 20-30 cm X 20mm thick machine pressed set jointed and pointed in neat grey cement slurry in floors over and including 20mm thick screed bed in CM 1:4, etc complete all as specified and as directed. | 220 | Sqm | - | - |
| 8 | Removal of debris (Aggregates) obatained from demolition including loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed. | 52 | Per Load | - | - |
| 9 | M&L for Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding , any type , any location/height( roof, parapet walls near pipes etc) and spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions after removing roots from wall slabs for preventing the regrowing and making good the disturbed portion using PCC 1:2:4 type B-0 with 12.5mm graded aggregate and plaster in CM 1:3 (Size of the disturbed portion 150X150X150mm) etc complete all as specified and as directed. | 20 | Each | - | - |
| 10 | Cutting out V groove on cracks of walls and cleaning out, wetting, grouting with crack filler (Dr Fixit or equivalent) mixing with cement slurry, making good the surface by using CM 1:3 or PCC 1:2:4 type B-0 as required at site, as per manufactures instuctions, of any description and in any position, with necessary scaffoldings, as approved by Engr in charge | 40 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderPages8732.pdf
Tender Documents • 1.61 MB
BOQ_878918.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .