RequiredOEM Authorization Certificate Bid to RA enabled No Emergency Lighting And Accessories (PORTABLE EMERGENCY LIGHTING SYSTEM Tower Type With AC Genset) ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Portable emergency lighting system consisting one Gen set
RequiredTower/Telescopic collapsible mast/Vertical mast
RequiredLED Luminaire
RequiredSupporting kits
RequiredTool Kits
RequiredStorage box for tool kit (Tool kit list to Yes * 1/7 be furnihed by seller at the time of supply) Rating of Generator set (in KVA) (Minimum) 2.0 KVA 2.0 KVA Number of cylinder in the Engine 2 Cylinder 2 Cylinder
Required3 Cylinder Minimum continuous working hours 8 hours 4 hours
Required8 hours Gen set fuel tank capacity (Minimum) - in litres 5 litres 5 litres
Required20 litres Type of fuel Petrol Petrol Minimum System Lumens 50000 20000
Required50000 IP rating of LED Luminaire IP66 * Ruggedised Storage Box for main equipment Yes * TOWER CONSTRUCTION Minimum height of Tower/Telescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) Yes 4
Required5
Required6
Required7
Required8
Required9
Required10
Required12 Material of Tower/Telescopic collapsible mast Vertical Mast Mild steel Mild steel Minimum thickness of Tower/Telescopic collapsible mast/Vertical Mast material (+/-5%) 4 mm * Method of step up and step down of Tower Telescopic collapsible mast/Vertical Mast Manual * Step up and step down time of Tower Telescopic collapsible mast/Vertical Mast </=30 sec * The strength of the Tower/Telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain 80 Km/hr * 2/7 erect at wind speed of GENERATOR SET CONSTRUCTION Generator Set: Recoil start portable AC Generating set comprising AC Generator with declared rating 230 V Single Phase of unit power factor conforming to IS:13364 (Part 1/92) and petrol run air cooled four stroke single cylinder engine with resettable circuit breaker in the AC output Yes * Type of mounting With out trolley With out trolley Engines shall conforming to IS:7347/1974 (Reaffirmed in 2006) latest Yes * Alternator shall conforming to IS: 13364 (Part 1)/1992 (Reaffirmed 2003) latest Yes * System should work on 220/230V
Required50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes * LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * LED Modules as per the IS: 16103(Part-2)/2012 Yes * Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * LED chip Efficacy ≥130 Lm/Watt * 3/7 Colour temperature (+/-500K) 5000K * Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) >/= 50
Required000 burning hours * Colour Rendering Index(CRI) ≥70 * Optic lense materal (UV stabilised) Poly carbonate lense * The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Extruded silicon loop gasket shall be provided to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Operating temperature range -20 deg. C to +50 deg. C * 4/7 "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * Date of manufacture (month-year)
Requiredand lot number as identification mark inside of each unit Yes * REPORTS AND CERTIFICATIONS Availability of type test reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine
RequiredAlternator and Luminaires as per relevant IS specifications as applicable Yes * Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes * Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Yes * 5/7 Consignee) LED Luminaire shall have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as applicable as on date Yes * Total Weight of complete system (Must declare) in Kg </=20 Kg * Warranty for complete system 1 Year * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.