Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC RAMAKRISHNA COLONY PO MAJHIPARA DIST 24 PARGANAS NORTH PIN 743145 STATE WEST BENGAL | 24 PARAGANAS NORTH | WEST BENGAL | 743145 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹36.9 L+₹3.2 L (9.53%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹37.5 L+₹3.8 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹38.0 L+₹4.3 L (12.9%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹38.1 L+₹4.4 L (13.2%)Rejected-Finance ANAND GUJARAT 388001 | ANAND | GUJARAT | 388001 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
3 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIR TO ROOF OF BLDG NO. NP-158 AND REPLACEMENT OF LT FEEDER PILLARS, BUS BAR BOXES, APFC PANELS, PCC POLES AND ALLIED WORKS AT KANCHRAPARA UNDER GE BARRACKPORE
2022_MES_537760_1
8676/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹62,000
Yes
25 Aug 2022
13 Jul 2022
5 Aug 2022
13 Jul 2022
3 Aug 2022
28 Jul 2022
Amount
PART-I Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, fixing hold fast including necessary form work complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
S&F of rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
M&L for rendering 15mm thick on brick works or concrete surfaces of walls and roof with cement mortar (1:4) mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately under relevant item)
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick putty on ceiling surfaces after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of old steel surfaces of any description over 10cm width or girth complete all as specified and directed.
S&F of 4.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
PART-II Disconnecting the electrification and taking down old DBs( any type of vertical load line/TPN/SPN DBs) and making good to the disturbed surfaces to match the existing surfaces complete all as specified and directed. (Note: Temporary power supply shall be provided by the contractor)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch .
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
Ditto-all as per Item No.21.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F of stepped type (0-4/5 step) electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserivceable brackets complete all as specified and directed.
S&F of MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
M&L for earthing with glavanised steel eart plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable earthing complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after and including taking down old unserviceable earthing complete all as specified and directed. (Note: Galvanised iron strip of 25X4mm upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed.
Taking down unserviceable submain wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
S&F of MS cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
S&F of sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 complete all as specified and directed.
S&F of surface and wall mounted LED batten 4 feet with 1X20 watt indoor decorative luminaries with and including electronic driver and 1X20 watt LED lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 sqmm 3 core not more than 1 mtr in length from ceiling rose/connector to light fitting complete all as specified and directed.
M&L for disconnecting electric supply, taking down fan, ceiling cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size and refixing the same after satisfactory testing in existing position complete all as specified and directed.
M&L for dismantling unserviceable/rusted cross arms of MS channel or angle/flat iron sections, nuts bolts etc from LT poles complete all as specified and as directed.
Dismantling old unserviceable insulators any type and size from RCC/PCC poles complete of 9 mtr long from ground level complete all as specified.
Distmantling old unserviceable/rusted stay assembly set somplete demolition of concrete etc all as specified and directed.
Dismantling of concrete poles/struts any size complete and transporting to store yard all as specified
Dismantling and taking down old serviceable LED street light fitting of any wattage, from LT swaged pole 9 mtr long complete making necessary connection complete all as specified and directed.
S&F of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed..
Supply, installing, testing and commissioning LT outdoor feeder pillar box (CPRI approved), powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 1100X1100X500 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54) in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 50 mm x 50 mm x 6 mm thick and 900 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber with RYB indicator LED lamps, digital ammeter and voltmeter including taking down old unserviceable feeder pillar box complete all as specified and directed. The scope of work also comprising of the following:- (A) Aluminium Bus bar chamber rating : 250 Amps TPN, 415V (B) Incoming MCCB rating : 160 Amps, 4P, 25 KA - 01 (C) Outgoing MCCBs rating : 63 Amps, 4P, 18KA - 04, (II) MCB SPN 32 A, SPN, 10 KA - 02 Nos NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in unit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box (CPRI approved), powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 750X600X300 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators . The panel shall be dust and vermin proof, protection class (IP-54) in accordance with IS-2147. b) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5mm thick and 450 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrumen chamber with RYB indicator LED lamps including taking down old unserviceable bus bar box complete all as specified and directed. The scope of work also comprising of the following:- (A) Aluminium Bus bar chamber rating : 200 Amps, TPN, 415V (B) Incoming MCCB rating : 160 Amps, 4P, 25 KA - 01 NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in uit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
Supply and fixing Polycabonate fabricated, outdoor type, cubical, sloping canopy top roof, pole mounted, hinged single door with locking arrangement, front side openable box suitable for three pahse, 415 volts, AC supply with 04 Nos Aluminium bus bar rating 32 amps (R.N) with one No MCB 06 Amps, SP having size 250x200x120 mm complete including making fixing arrangement with LT pole swaged type with flat iron clamp all as specified and directed .
S&F of 1100 Volts grade heavy duty cable PVC insulated copper conductor FR round flexible in street light connection from pole junction box at bottom to street light fixed on LT pole swaged type by making two holes with welding machine for inserting cable of 8.5/9 mtr long swaged pole cable of size 0.50 Sqmm 3 core multistranded including making all necessary connection all as specified.
Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 20 watts rating, LED type, made with high efficiency Mono crystalline solar PV module, lithium ferro phosphate battery with in built BMS technology, high efficacy LED, MPPT solar charge controller and aluminium extruted body, automatically programmed to control the dimming and brightness complete all as specified and directed.
Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 30 watts rating, LED type, made with high efficiency Mono crystalline solar PV module, lithium ferro phosphate battery with in built BMS technology, high efficacy LED, MPPT solar charge controller and aluminium extruted body, automatically programmed to control the dimming and brightness complete all as specified and directed.
M/S D K Singha
INDUSTRIAL CONSTRUCTION
M/S. ARUP KUMAR DEY
M/S RAJESH TRADING CO
ABHISHEK CONSTRUCTION CO
CHATTERJEE ENTERPRISE
M/s S K SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .