Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC L1 Agreement executed | |
| 2 | L2₹6.6 L+₹20,088.85 (3.14%)Rejected-Finance | L2 | Rejected-Finance Higher rate and hence not admitted |
| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L1 | Cool Palace Hoome Appliances L2 |
|---|---|---|---|---|---|
| 1.00SITC of AC | |||||
| 1.00 | OD201570/2025-2026:Supply , Installation, Testing and Commissioning of 1.5TR, Air Cooled Hi Wall Invertor split type Air conditioners of ISEER 5 or above complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP | 2 | each | 51,262.72 ₹1,02,525.44 Lowest | 53,000 ₹1,06,000 |
| 1.00 | OD201364/2025-2026:Supply , Installation, Testing and Commissioning of 2TR, Air Cooled Hi Wall Invertor split type Air conditioners of ISEER 5 or above complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP | 1 | each | 64,192.17 ₹64,192.17 Lowest | 66,000 ₹66,000 |
| 1.00 | OD201515/2025-2026:
Supply , Installation, Testing and Commissioning of 3TR, 3 Star rated Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP | 4 | each | 1,04,078.2 ₹4,16,312.8 Lowest | 1,07,000 ₹4,28,000 |
| 1.00 | OD201423/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 5/8 inch (15.875 mm) 22 gauge | 15 | metre | 908.24 ₹13,623.6 Lowest | 950 ₹14,250 |
| 1.00 | OD201043/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.525 mm) and 5/8 inch (15.875 mm) 22 gauge | 20 | metre | 982.58 ₹19,651.6 Lowest | 1,000 ₹20,000 |
| 1.01 | OD201041/2025-2026:Supply and fixing of 25 mm outer dia. 10kgf cm2 PVC pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required | 30 | metre | 79.23 ₹2,376.9 Lowest | 100 ₹3,000 |
| 1.01 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm | 26 | metre | 140.66 ₹3,657.16 Lowest | 150 ₹3,900 |
| 1.01 | 90.6.5.20:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm | 35 | metre | 189.16 ₹6,620.6 Lowest | 195 ₹6,825 |
| 1.01 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top | 3 | each | 125.15 ₹375.45 Lowest | 130 ₹390 |
Tender Value
Refer Docs
EMD Value
₹15,973
Closing Date
13 Mar 2026, 2:30 pmClosed
Assistant Executive Engineer
PWD Electrical Sub Division, KLCThiruvananthapuram
GENERAL-Kerala Raj Bhavan - Replacement of old and obsolete Air conditioner units in Guest block-Raj Bhavan Kerala - AC replacement -Electrical AC Work
2026_PWD_845143_1
PWD/BLDG/TR/20497/2025
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,410
₹15,973
25 May 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
SITC of AC
OD201570/2025-2026:Supply , Installation, Testing and Commissioning of 1.5TR, Air Cooled Hi Wall Invertor split type Air conditioners of ISEER 5 or above complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP
OD201364/2025-2026:Supply , Installation, Testing and Commissioning of 2TR, Air Cooled Hi Wall Invertor split type Air conditioners of ISEER 5 or above complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP
OD201515/2025-2026: Supply , Installation, Testing and Commissioning of 3TR, 3 Star rated Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evaporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract with in the entire DLP
OD201423/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 5/8 inch (15.875 mm) 22 gauge
OD201043/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.525 mm) and 5/8 inch (15.875 mm) 22 gauge
OD201041/2025-2026:Supply and fixing of 25 mm outer dia. 10kgf cm2 PVC pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.20:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
OD201044/2025-2026:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top
OD201485/2025-2026:Supply and installation for the heavy duty Out door unit stand of 3TR A/C unit.:-Out door unit stand
OD201453/2025-2026:Dismantling the existing indoor and out door unit 1 TR/1.5TR/2TR/2.5TR/3TR and conveyance to store
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1427144.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1427144.xls
BOQ • 0.31 MB
agree.pdf
Other Document • 0.53 MB
form.pdf
Other Document • 0.37 MB
IP.pdf
Other Document • 0.19 MB
viewsbd.pdf
Tender Documents • 1.63 MB
affi.pdf
Other Document • 0.47 MB
epayment.pdf
Other Document • 0.38 MB
make.pdf
Other Document • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .