OFFICE OF ASSISSTANT ENGINEER LID AND EW SECTION V
OFFICE OF ASSISTANT ENGINEER LID AND EW SECTION VATHIKUDY
Annual Plan-VATHIKUDY GP 2026-27 MURICKASSERY BUS STAND BUILDING MAINTENANCE.-PROJECT NO.209/27
2026_LSGD_877260_25
01/AE/TND/LID/EW/VTY/26/27
Open Tender
Civil Works - Roads
Item Rate
Vathikudy G.P
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹27,539
Yes
9 Oct 2026
9 Oct 2026
22 Oct 2026
9 Oct 2026
17 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1MAINTENANCE | |||||
| 1.001 | 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet | 24.79 | sqm | - | - |
| 1.002 | 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar | 1.55 | cum | - | - |
| 1.003 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 0.51 | cum | - | - |
| 1.004 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 2,203.69 | kg | - | - |
| 1.005 | OD104183/2026-2027:Roofing with G.I trafford profile sheet 0.35 mm thick , powder coated with overlaps of 150mm
at ends and SS screws including plain washers and bitumen washers etc. complete | 557.18 | sqm | - | - |
| 1.006 | OD113029/2026-2027:Designing, fabricating,testing and installing Curtain Wall with Aluminium Composite
Panel Cladding, with open grooves for linear as well as curvilinear portions of the
building , for
all heights
and all levels etc. including:
Providing, fabricating and supplying and fixing panels of aluminium composite panel
cladding
INCLUDING
aluminium base frame work in pan shape in metalic colour of approved shades made
out of
3mm thick
aluminium composite panel material. The aluminium composite panel cladding sheet
shall be
coil coated,
with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of
approved colour
and shade on
face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel
screws,
nuts, bolts,
washers, cleats, weather silicone sealant, backer rods etc.with aluminium composite
panel
cladding till the
handing over of the building for occupation. The Contractor shall provide curtain wall
with
aluminium
composite panel cladding, having all the performance characteristics all complete, as
per the
Architectural
drawings, as per item description, as specified, as per theapproved shop drawings and
as
directed by the
Engineer-in-Charge.However, for the purpose of payment, only the actual area on the
external
face of the
curtain wall with Aluminum Composite Panel Cladding (including width of groove)
shall be
measured in sqm.
up to two decimal places.
OD86/21-22 - Modified data 25.7 | 71.92 | sqm | - | - |
| 1.007 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 1.98 | cum | - | - |
| 1.008 | OD104312/2026-2027:Providing and fixing 200 mm wide square uPVC rain water gutter including all
necessary fittings and making all necessary connnections complete as per the direction of engineer in charge at site OD75/21-22 | 25 | metre | - | - |
| 1.009 | 50.18.9.18.2:Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall | 18 | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 0.03 MB
viewsbd.pdf
Tender Documents • 1.91 MB
BOQ_1491801.xls
BOQ • 0.31 MB
viewnit.pdf
Tender Documents • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .